HomeMy WebLinkAboutInterior Lighting Compliance Certificate 04.28.2017RECEIVED COMcheck Software Version 4.0.6.0 Interior Lighting Compliance APR 2 8 2017 Certificate B&H General Contractors Section 1: Pr ' t~Inty mation Energy Cod 2009 IECC Project Tit] CRMS Bar Project Type: . n Construction Site: Owner/Agent: Designer/Contractor: Colorado Rocky Mountain School Colorado Rocky Mountain School Bighorn Consulting Engineers Carbondale, CO Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (tt2) Watts / ft2 (B x C) Strength/conditioning (Exercise Center) 2237 1 2237 CRMS (School/University) 2041 1.2 2449 Total Allowed Watts = 4686 Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Strength/conditioning ( Exercise Center 2237 sq.ft.) LED 1: L1: LED Linear 10W: LED 2: L2: LED Linear 33W: LED 3: L3: LED Linear 17W: LED 4: L4: LED Linear 33W: LED 5: L5: LED Linear 33W: CRMS ( School/University 2041 sq.ft.) LED 6: L6: LED Linear 20W: LED 7: L7: LED Linear 33W: LED 8: L8: LED Linear 10W: LED 9: L9: LED PAR 20W: LED 10: L10: LED Other Fixture Unit 40W: LED 11: L11: LED Other Fixture Unit 60W: LED 12: L12: LED A Lamp 13W: Section 4: Requirements Checklist B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 1 6 9.8 58.8 1 4 37.2 148.8 1 3 17.2 51.6 1 2 34.4 68 8 1 9 68.8 619.2 1 4 19.6 78.4 1 5 39.2 196 1 1 9.8 9.8 1 3 21 63 1 3 40 120 1 5 63 315 1 6 14.2 852 Total Proposed Watts = 1815 Interior Lighting PASSES Lighting Wattage: p 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 4686 1815 Passes Controls, Switching, and Wiring: 2. Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. Project Title: CRMS Bar Fork Data filename: Z:\2017 Projects\17002 CRMS Bar Fork\energy - com check\17002_comcheck.cck Page 1 of 2 Report date: 04/27/17 ❑ 3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: ❑ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ` ❑ Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. ❑ 4 Independent controls for each space (switch/occupancy sensor). Exceptions: ❑ Areas designated as security or emergency areas that must be continuously illuminated. ❑ Lighting in stairways or corridors that are elements of the means of egress. ❑ 5. Master switch at entry to hotel/motel guest room. ❑ 6. Individual dwelling units separately metered. ❑ 7. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. ❑ 8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle lamp luminaires independently of other lamps, or switching each luminaire or each lamp. Exceptions: ❑ Only one luminaire in space. ❑ An occupant -sensing device controls the area. ❑ The area is a corridor, storeroom, restroom, public lobby or sleeping unit. ❑ Areas that use less than 0.6 Watts/sq.ft. ❑ 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft Exceptions: ❑ Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. ❑ 10. Photocell/astronomical time switch on exterior lights. Exceptions: ❑ Lighting intended for 24 hour use. ❑ 11.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: ❑ Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 5: Compliance Statement Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting alteration project has been designed to meet the 2009 IECC, Chapter 8, requirements in COMcheck Version 4.0.6.0 and to comply with the mandatory requirements in the Requirements Checklist. Shawn Brill - engineer Name - Title Sha w v 3 rab 4-27-17 Signature Date Project Title: CRMS Bar Fork Report date: 04/27/17 Data filename: Z:\2017 Projects\17002 CRMS Bar Fork\energy - com check\17002_comcheck.cck Page 2 of 2