Loading...
HomeMy WebLinkAboutApplicationGarfield County Building & Sanitation Department 108 8th Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 NO. c 71G$ Job Address 4q D �' � [ �_ r-�1 c� Nature of Work Building Permit (r+ j(-;ter-Ro_A-P-----T.cknek......_ Use of Building Owner Contractor Amount of Permit $ Date Clerk The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 4460 6 s2_.lt> 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; S. All ste side or inside over three (3) steps must have handrails, guard rails on balconies or decks ove 30 high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, anchor State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy use and the issuance of a Certificate of Occupancy for the dwelling under building permit # 7 Ir)91 Signature BpcontOct2004 .rc�4---' Date VALUATION/FEE DETERMINATION Applicant L y Subdivision G Pert Par K o c.k_ Address y -`f00 '' - ° .,,� Leone, Lot/Block Aarce Date /01 -R705 ---Contractor 0 03 r\-.✓` Finished (Livable Area): Main Upper Lower Other Liza odo �$ 3. Total Square Feet Z2 40 � -741� — /e7, Z g Valuation Basement: Unfinished P) -Q0 4 4/ Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation Valuation Decks/Patios: Covered Valuation Open Valuation 5z/4-ica 03 /ow 24 ' 740 U Total Valuation 2(4y6632� GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans / to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and .— drawn to scale. 1 Plans must include a floor plana, concrete footing and foundation planelevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. i. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes /y 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent pro ernes), streams or water courses? Yes I 2 vvv- - Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No • 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes Z No kidiCEC 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes // No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes // No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not be accepted without it. Yes_ to -- No 21. Will this be the only residential structure on the parcel? Yes GS Of- _ moi, 7 No If no -Explain: �_- 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. lowi? Y es No 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes ✓l 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes ',:fir =r 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? YesGYM 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes L- 11. Does the building section drawing or other detail include the method ofpositive connection of all columns and beams? Yes 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of _ shed roof or the top of a flat roof? (Building height measurement usua anon -exceed 25 feet) Yes — 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No 3 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes L No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes No 27. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes// No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a S50.00 re -inspection fee? Yes � No 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes t/ No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes I_- No 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes C— No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes No 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes j No (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? 7 Yes 0 I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. SigniCc ature of Owner Phone: Project Name: Project Address: 4400 &Ct�-t Comtet.1 you have ,�� Notes: If answered No on any oft 1e questions\ youtna e tlp information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application (days); Date k_(evenings) 6 may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqFeb2005 7 • Basement wall R -values are R-10 below grade, R-19 above grade. • Slab perimeter R -value and depth is R- 10/36in. • Crawl space wall R -values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST ApplicantG. I Date Building Engineered Foundation gd Driveway Permit Planning/Zoning property Line Setbacks 130ft Stream Setbacks Surveyed Site Plan Flood Plain Septic Permit and SetbacksSIRg fBuildin2 Height mooning Sign -off LRoad Impact Fees 4"-A/DRC Approval 1'(Jra'de/Topography 40% • Fire Department Review IPlanning Issues L/Valuation Determination/Fees Subdivision Plat Notes �Gradefropography 30% Attach Residential Plan Review List Minimum Application Questionnaire I Subdivision Plat Notes �/ Red Line Plans/Stamps/Sticker Attach Conditions z/ A pP li on Signed Plan iewer To Sign Application arcel/Schedule No. 40# Snowload Letter- Manf. Hms. 1 Soils Report GENERAL NOTES: GLEN PARK RANCH HOMEOWNERS ASSOCIATION P.O. BOX 1150 GLENWOOD SPRINGS, CO 81602 September 9, 2005 Leroy Green 703 Silver Oak Drive Glenwood Springs, CO 81601 Re: Home Construction Approval Dear Mr. Green: Thank you for allowing us to review your house plans. It looks like a very nice house and we are granting your request for construction. If we can be of further assistance, do not hesitate to contact us. Sincerely, GLEN PARK RANCH HOMEOWNERS ASSOCIATION A. Kleager S etary, Treasurer LAK/lxs I:\clients\G\GlenParkRanch.36880\LGreenConstltr.doc 06/21/2005 03:12 6258627 ROAD AND BRIDGE PAGE 01 CGarfield County Garfield County Road and Bridge Department June 21, 2005 Lee Green 703 Silver Oak Drive Fax: 945-2593 Attn: Tanya CC; Garfield County Building and Planning Department Dear Mr. Green; The property you own is beyond the county road system and access is actually from a Glenwood city street; therefore, you do not need a driveway permit from Gatfceld County. If you have any questions or problems, please feel free to contact me. Sincerely, Mail Garfield County !toad and Bridge Department 902 Tawgbcabaa(b Blvd. Suite 305 Bine, CO 816.i' 0 Phone: 970425-3601 PAZ 97042 4627 SOC''06'22"W S00'35'39"W MutS,22.00N 760 E0016'29"E 2751 44 :_ 48 S0129'l0"W 2749.60' 2749.61' CHIMNEYS AND FIREPLACES TABLE R1003.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS LETTERa ITEM Hearth slab thickness Hearth extension (each side of opening) Hearth extension (front of opening) Hearth slab reinforcing A B C D E F G H J Thickness of wall of firebox Distance from top of opening to throat Smoke chamber wall thickness Unlined walls Chimney Vertical reinforcingb 8" fireplace opening < 6 sq. ft. 12" fireplace opening —> 6 sq. ft. 16" fireplace opening < 6 sq. ft. 20" fireplace opening >_ 6 sq. ft. Reinforced to carry its own weight and all imposed loads. 10" solid brick or 8" where a firebrick lining is used. Joints in firebrick 1/4" max. Horizontal reinforcing Four No. 4 full-length bars for chimney up to 40" wide. Add two No. 4 bars for each additional 40" or fraction of width or each additional flue. 1/4" ties at 18" and two ties at each bend in vertical steel. Bond beams Fireplace lintel Chimney walls with flue lining Walls with unlined flue Distances between adjacent flues Effective flue area (based on area of fireplace opening) Clearances: Combustible material Mantel and trim Above roof Anchorageb Strap Number Embedment into chimney Fasten to Bolts M Footing Thickness Width For Si: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 square fool = 0.0929 m2. NOTE: This table provides a summary of major requirements for tate construction of masonry chimneys and fireplaces. Leiter references arc to Figure. R3003-1, which showsexampies oftypical codessee construction. i histabl sectionac cove allrequircments, nor dots itcoverall aspects afthe iindicatedrequirements. For the acn"" mandatory requirements of the a. The letters refer to Figure R1003.1. b. Not required in Seismic Design Category A, B or C. P R S No specified requirement Noncombustible material. Solid masonry units or hollow masonry units grouted solid with at least 4 inch nominal thickness. 8" solid masonry. See Section R1001.10. See Section R1001.12. See Sections R1001.15 and R1003.12. See Section R1001.13. 3' a roofline and 2' at 10'. 3/16 x1" Two 12" hooked around outer bar with 6" extension 4 joists Two 1/2' diameter. 268 2003 INTERNATIONAL RESIDENTIAL C00E- O BOND BEAM MORTAR CAP © EFFECTIVE FLUE AREA 0 BOND BEAM FLUE LINING 0 BOND BEAM d HORIZONTAL REINFORCING TIES O WALL THICKNESS PARGE WITH NV.IV MORTAR 8 IN. MIN. OGSMOKE CHAMBER 1/2 IN. MIN. HOVERTICAL REINFORCING 2 FT. MIN. IIMASONRY CAP 0717-11 DETAIL FOR 1' FULL MASONRY WALL OTIRCKNE WALL ,1 THICKNESS -- � HEARTH 20 IN, VI MIN. FIREBRICK VENEER TIE CLEARANCE ) ANCHORAGE O ANCHORAGE THERMAL DISTANCE 21 IN. MIN. of PURGE \8 Ir \ WI MORTAR LINTEL© HEARTH EXTENSION AOTTHICKN SS B� f DETAIL WITH WOOD MATERIAL MEASURE HEIGHT OF FREE STANDING FIREPLACE FROM . TOP OF FOOTING FIREPLACE OPENING HEIGHT ASH DUMP D PTH SLAB CLEAN OUT OPTIONAL- ti J REINFORCEMENT MENT \\\'/// \\1 OT FOOTING WIDTH et p 'I// al 181N, MIN. GRADE FOOTING WIDTH BRICK FIREBOX AND CHIMNEY— SECTIONAL SIDE VIEW ON WOOD FLOOR For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. C63 INTERNATIONAL RESIDENTIAL CODE® CHIMNEYS AND FIREPLACES WIDTH OF FIREPLACE OPENING 2 FT. MIN. CLEARANCE O 10 FT. MIN. PLAN VIEW ANCHORAGE 21/2 IN. BOLTS EACH STRAP CLEARANCE OR HEARTH EXTENSION 8 IN. MIN. 4 IN. MIN. MORTAR CAP OK BOND BEAM OHORIZONTAL REINFORCING TIES OVERTICAL REINFORCING ANCHOR STRAP 11/2 IN. MIN. GROUT BETWEEN 4 IN. CONCRETE MASONRY AND CLAY FLUE LINING FLUE LINER 6 IN. MIN. OHORIZONTAL REINFORCING TIES 1/2 IN. MIN. 4 IN. THICK MASONRY UNITS LINTEL \Wf// \\\' FOOTING DEPTH VERTICAL REINFORCING 20 IN. LAP IF SPLICED TO FOOTING DOWELS FIREBOX WALL THICKNESS FOOTING WIDTH 6 IN. AROUND FREE STANDING FIREPLACE \\\ NATURAL GRADE BARS IN CONCRETE FOOTING HEARTH 20 IN. MIN. BRICK FIREBOX AND BLOCK CHIMNEY— SECTIONAL SIDE VIEW ON CONCRETE SLAB FIGURE R1003.1 FIREPLACE AND CHIMNEY DETAILS 269 •