Loading...
HomeMy WebLinkAboutApplication- PermitN o . 5818 GARFIELD COUNTY BUILDING, SANTTA TION and PLANNING DEPARTMENT 109 8th Strout Suitc 303 Glenwood Springs, Colorado 81601 (303) 91S-8212 Job Address 'n3/5- County Road 229, Silt Nature of Work Use or Building ^Ij Owner Building Permit Single_Ear11y Dwelling w/Double Garage T&M Construction, Inc. Contractor Ernst Shopp Amount of Pcrmit $ 2024.96 Paid Permit: 1227.25 Plan : 797.71 $651.46 2-14-96 Date March 20, 1996 S. Archuleta Clerk BUILDING PERMIT APPLICATION GARFIELD COUNTY, COLORADO Applicant to complete numbered spaces on PERMIT NO. 6 gig PARCEUSCHED NO. Joe ADDRESS 0/ ' f A•/e, Qt.? cQQ 5/ L. J 1 LEGAL DESCR. LOT NO. BLOCK SUBDIVISION 5 Tem 2 OWNER 57 5 )..„ ©{� ADDRESS O 3�elei PH. g dl, l WK. PH ,25 -1 33 : 3 CONTRACTORTi. rn c 8 ,A0 1 , ADDRESS )6,7,91-31625 s//TCS PH.R 76'- LICENSE NO. �- - 4 ARCHITECT OR DESGNER %�s, �4f6z. yL �/"? ADDRESS ...1.1.4./9:::)5'"-r.;!' `f' [3 ,,,,,_z----,,; 3/ y� GCS�S3_f /� ICLNSENO. 5 ENGINEER I �S ADDRESS PH. LICENSE NO. 6 Sir OF BUILDING /83,:,?s•9 / S.F OF LOT //.vJc,,t i S' .1- HEIGHT j8 No. or FLOORS / 7 USE OF BUILDING y( ;'y r J6, l V, a .S 1 / fir' /S - .. _/7 .,-)4--.)-,-7/76t, /� J? f 8 CLASS OF WORK XNEW D ADDITION D ALTERATION a REPAIR ❑ MOVE �R//EMOVE 9 DESCRIDE WORK: wJ'/ k 1 41j STi , K -4C.4,.. YL Ji 11 ,1 i iC I 1 .]l) /756-i Li iu1 10 GARAGE SINGLE UBL�LTJ 4 6 ' r CARPORT SINGLE DOUBLE DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN 7 9 7. 7/ 11 VALUATION OF WORK: S /Q 602) ADJUSTED ! VAL.$ l6„' •� .Z t% 1-R-479-94X1 •e CZ 7/40 c a PERMIT FEE / 2 7, �'' PLAN CHECK FE -51, / 1 rVV SPECIAL CONDITIONS', /8.3a p ' �6 3 , l a : // .5/ 599, jf 4/0 a' X /6 •G / -7 . 7 3 il 3 -0 SCHOOL IMP T FEE NO. OF BUILDINGS ON PARCEL USE OF BUILDINGS NOW ON PARCEL g� /� +� y,� / / TOTAL f ,4'e 9 L/ OCC. GR. CONST. TYPE SEPARATE PERMITS VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NOT COMMENCED WITHIN OR ABANDONED FOR COMMENCED. I'HEREBY CERTIFY THAT THE SAME TO BE TRUE GOVERNING THIS TYPE HEREIN OR NOT. THE AUTHORITY TO VIOLATE LOCAL LAW REGULATING TI NOTICE ARE REQUIRED FOR ELECTRICAL. PLUMBING, NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED A PERIOD OF 189 DAYS AT ANY TIME AFTER I HAVE READ AND EXAMINED THIS APPLICATION AND AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED GRANTING OF A PERMIT DOES NOT PRESUME OR CANCEL THE PROVISIONS OF ANY OTHER STATE .'3NST,'y�• TION OR THE PERFOOSRMANCE '.•i=1' (Dal , - WATER SUPPLY _ DATE PERMIT ISSUED .3 702, a l,4, L HEATING, SPFCALAFPaOVALs REYJIRED RECEIVED NOT REQUIRED IS ZONING WORK IS HEALTH DEPT. KNOW FIRE DEPT. TO GIVE SOIL REPORT OR OF SETBACKS L.,41.191/ FLOOD HAZARD Signature of dm r,, contractor or authorized agent ' i re.. a,, tool notice above. MANUF. HOME Building epa ment Approved 8 Planning Department A prove 1..:y� OTHEI SPS Fr! '3 a AGREEMENT PERMISSION 1S HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS !N SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform,003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL OIL 7oJ. 2L¢> �2 ��v'/'�._ [r c <_ eu-.. a °u mI e 7 3041i -q'ylh dt°r F3IlrhenV •1 .'- r 911 C 3. wf iiIp-49 3 5:2'i is " fi W '• -- \ / '• NON V/ / z I t •t I I 20 1 1 1 N nr/ of IJ 110 icor) 1 .P NI 000 1 N .. 1 1 • '^ 311 O =1 I V ;1 1 01 I L. �1 I(II • m 001 1 O - 1 A, a 1 \ V 1\ -0 \ \ R \ nN 1 \ \ a I N 1 m [11/, 1 m^ i...2 1 0100 •1e 0 J �4,4 !n t .j m 1 Prl 1 • nit 1 1 \ : 1 N \ \ in, \ • /iP \ ^o \\\ nP \ \ '0 3 \ \ N `rs ,/\ \ C \ - 1'. 1•1 .c • : regh.— LL w N t -V JV"o�=C a ,.. .2 o - 90 • in e 6Tct` •P '0 2 V t. P♦ N.w C • O� V [ N V , 3\j`•V -•wr o8` N OV��O- 1 3 •r_ O`•c•- L1 63 •Tr '10 w• C efi< i >�m� 0.9t nce 4 • eem• vS 1 `OEo..oc ✓ LL e T _0 a V l R •• •PV2 V1' e_ d nN••-:. 40 ;t: 6 AO•EmoE-••-< \ \ \ SLBfi ■.IS.ft•.00N \ \,( 9• ZP6 L GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: 1 Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easemnxfts and utility easements? Yes 4 No (i) Not necessary for this project (2) 2.) Does the site plan include the location of the I.S.D.S. (Individual —� Sewage Disposal System) and the distances to property lines, wells (on subject property ancli adjacent properties) , streams or water courses? Yes No v (0 Not necessary for this project (2) 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes JJ No (t) Not necessary for this project (2) 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform buildir g code or per stamped engineered design? Yes VV No (1) Not necessary for this project {2) 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? / Yes No (i) Not necessary for this project i/ (2) 6. Do the plans indicate the size an location of ventilation openings for the atti , roof joist spaces and soffits? Yes No _coNot necessary for this project (2) 7. Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per squareffoot in Garfield County) floor loads and wind loads? Yes ✓✓ No (1) Not necessary for this project 2) 8. Does the plan include a building section drawing indicating found ion, wall, floor and roof construction? Yes ✓✓ No (I) Not necessary for this project (2) 9. Does th building section drawing include size and spacing of floor joists, all studs, ceiling joists, roof rafters or joists or trusses? Yes _ No (L) Not necessary for this project (2) 2 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes V No to Not necessary for this project «> 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span bjtween the ridge and the eave down to existing grade contours? Yes ✓✓ No (1) Not necessary for this project (2) 12. Does the plan include any stove or zero clearance fireplace planned for installation including snake and model and Colorado Phase II certifications or ph e II EPA certification? Yes No _ ___(o Not necessary for this project (2) 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No o) Not necessary for this project (2) 14. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes ✓✓ No 0) Not necessary for this project (2) 13. Does th plan include a window schedule or other verification that windo s provide natural light and ventilation for all habitable rooms? Yes No (i) Not necessary for this project (2) 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes 1/ No (1) Not necessary for this project (2) 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and w' er heaters indicated ori the plan? Yes // No n, Not necessary for this project (2) 18 Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from that association, if required by that association, prior to submitti�t4g an application for a building permit? Yes No _0) Not necessary for this project V (2) 3 19. Have two (2) complete sets of constructions drawings been submitted with t application? Yes _ No (1) Not necessary for this project (2) 20. Is this an application for the placement of a manufactured home? Yes No If yes, have you specified the size of the unit (min. 20ft x 20ft); live roof Load (min.40#); wind design (min. wind speed of 80 mph & 15 lb. wind load); foundation design; method of anchoring? Yes No (() Not necessary for this project (2) 21. Have you designed or; had this plan designed while considering building and other c,$nstruction code requirements? Yes No �/ (3) 22. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield Building Departinent? Yes No (3) 23. Do you understand that approval for design and/or construction change are required prior to the application of these changes? Yes No (3) 24. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School impact" or "Septic system " fees required, at the time you pick up your building permitY Yes rr// No (3) 25. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupayicy of the building? Yes ✓✓ No (3) 26. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the project'complying with the Uniform Codes". Yes v No (3) (CONTINUED ON NEXT PAGE) 4 I hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. atotbd ems. 0? - 9 - signature - date Phone: 874 -51079 (days); c976 -517? (evenings) Project Name: VC n0 Pp YC c..S ,dzlocc Project Address: n33 s ein,,„4-'u ed, a3? 2,'113 C Notes: C•( (1) If you have answered "No" on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to he expected Work may not proceed without the issuance of the permit. (2) If you have answered "Not necessary for this project' on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in Issuance of the permit. C. Delay in proceeding with construction. (3) If you answered "No" to This question the circumstances described in the question could result in a "Stop Work Order' being Issued or a'Certificate of Occupancy' not being Issued. PerApp02.95 Effective August 15, 1995 5 lio- 23.74,- 4 7117 ° 6( X_Id '= s k rl 3)(3'1(_ -fly ."I 0' .400Ca'z im:c 4. 35(1i y 23IATz 0 . )/_40`11,04- 11JhAk? 10;12-44 [Le-a-faii_444 -210 5 �2( J�S 0 = 3!j Tn, z,472.1(-0 p �✓�2 4 Z 3/ ?r7.zo /47)37/x0 777, 7/.- 267°'0O 1- O D O 14.505 537-1f-, 74-- COUNTY OF GARFIELD — BUILDING DEPARTMENT CORRECTION NOTICE 2014 Blake Glenwood Springs, Colorado Phone 945-8241 Job located at Permit No. I have this day inspected this structure and these premises and found the following violations: You are hereby notified that no more work shall be done upon these premises until the above violations are corrected. When cor- rections have been made call for inspection. Date - 19 Building Inspector __ Phone 945-8241 iPsiedu ecru b o. r o llrilkgSig !drsip WmUrr THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GA FIELD COUNTY, COLORADO Date Issue/ f ti Zoned Area Permit No AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described st ucture, the permit may then be revoked by notice from the County Building Inspecto alM$DIATELYf ' ECOME NULL D VOID. /, „ j �- k an or, / Contractor re r "A` r 4 Use Address Owner Setbacks egal�D+escriptio Iiir Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing ...9-9.5-7b Ears Foundation ,L -i- , ;2, ;PE /4;i4 Underground Plumbing Insulation 5-76 . A,,,,, Rough Plumbing_r f_yj Drywall �� -01i-96 17>" -Ace Chimney & Vent Electric Final (by State Inspectorh Jl%'1 0.4. -- -.Gas Gas Piping j----__ ,,,{;i /4/, Final Electric Rough (By State Inspector)' Septic Final Framing a - '-`i' •-t-i,✓ (To include Roof in place and Windows and Doors installed). Notes: , ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado. APP'OVED DO NOT DESTROY THIS CARD Date" r : i., ar By r #'""')�