HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-08 -I7-4862
Kevin Everson - New S.F. Residence
159 Blue Heron Vista
lronbridge, Phase ll - Filings L,2 & 3, Block 2, Lot 273
Glenwood Springs, Colorado
1) ALL WORK SHALL COMply W|TH THE 20L5 TNTERNATTONAL RESIDENTIAL CODE (l.R.C.)
AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) REFER TO PLAN ATTACHMENTS FOR GARFTELD COUNTY BUILDTNG REQUTREMENTS.
REDLINED NUMERICAL NOTATIONS ON PLANS REFER TO ANNOTATED ITEMS ON THE
ATTACHED ,,RESIDENTIAL PLAN REVIEW LIST".
3) A LOT TMPROVEMENT CERTTFTCATE SEALED BY A COLORADO LICENSED SURVEYOR
IS REQUIRED AT UNDERGROUND PLUMBING INSPECTION TO VERIFV THAT STRUCTURE
(tNCLUDtNG ROOF OVERHANGS) tS tN COMPLIANCE W|TH ALL APPLICABLE BUILDING
SETBACKS. IN ADDITION, RESIDENCE SHALL BE SITUATED A MINIMUM OF 10 FEET AWAY
FROM ADJACENT HOMES (ROOF EAVE TO ROOF EAVE).
4l GEOTECHNTCAL ENGTNEER SHALL VERIFY PLACEMENT OF 8 FEET OF COMPACTED
STRUCTURAL FILL AND 1.,500 P.S.F. SOILS BEARING CAPACITY PER SOILS REPORT.
PROVIDE ENGINEER,S SEALED APPROVAL REPORT AT UNDERGROUND PLUMBING
INSPECTION.
5) tF AppLtcABLE, CONTACT BUtLDtNG DEPT. PR|OR TO CONCRETE POUR TO SCHEDULE
SPECIAL INSPECTION TO VERIFY PLACEMENT OF RIGID INSULATION THAT WILL BE
SUBSEQUENTLY CONCEALED FROM VIEW.
6) STRUCTURAL ENGTNEER SHALL FrELD VERTFY AND INSPECT THE HEAVTLY REINFORCED
STRUCTURAL SLAB FOUNDATION INCLUDING PLACEMENT OF STEEL REINFORCEMENT
BARS, ANCHOR BOLTS AND FORMWORK PRIOR TO CONCRETE SLAB POUR. PROVIDE
ENGINEER,S SEALED APPROVAL REPORT (WET STAMPED & SIGNED) PRIOR TO UNDER-
GROUND PLUMBING INSPECTION.
7) ELECTRTCAL PERMtTTtNG AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY