HomeMy WebLinkAboutEngineer's Report 08.07.2017Ernest Kollar Engineers, Inc. 320 Main St., Suite 203 Carbondale, CO 81623 Phone (970) 963-3223 erniekollar@gmail.com August 7, 2017 To: Jess Pedersen Archtitects Re: Flood Residence; 4339 Four Mile Road, Garfield County, CO Jess: Regarding the wall enclosure at the existing covered deck, please note the following: 1. The 2x10 ledger attachment with (2) Ledger -Lok screws at 16" o.c. is acceptable to carry the floor loads. 2. The existing cracked joist (7th joist from outside face) shall be replaced with the same size joist. 3. It is my understanding the built-up furring that aligns with the existing 2x10 joists was screwed to the top of the 2x10's with Timber -Lok screws @ 16" o.c.. From the photos, it appears one row of blocking was installed between the joists; the blocking extends from the underside of sheathing and laps the 2x10 approximately 2 inches. This should be sufficient. 4. The perimeter rim of the furring needs to be screwed to the timber beams with Timber - Lok screws at 16" o.c. Please call with any questions, egneci Ernest Kollar, PE