Loading...
HomeMy WebLinkAboutCorrespondence Cont.David Argo From: Sent: To: David Argo Monday, May 0L, 2017 6:42 AM Jason Lapointe (jlapointe@fuseacs.com) Eastbank Auto Repair ShopSubiect: Jason: I happened to come across the steel building drawings for the auto repair shop on Friday and realized that I forgot to return these drawings to you along with your building permit set of architectural + structural drawings. I will leave these drawings up front with Brooke & Lindsay so that you can stop by and pick up at your convenience' please attach these steel building drawings together with your approved plan set, because our building inspectors and your special inspector for high-strength bolting and field welding will need to be able to reference these plans when they are at the job site. Sorry for the inconvenience! DaveArgo Plans Examiner Garfield Coutrty Community Development Department 708 gth Street, Su¡te 407 Glenwood Springs, CO 81607 Tel: 970-945-8212 Ema il : d a rgo@ g o rfield-county.com Web : go rfie ld-cou nty. com CONF\DENT,AL.T( NOTTCE: This emøil communicotion and any fites tronsmitted along with it ore intended only for the person or ent¡ty to wh¡ch it ¡s addressed. lf you have received this emai! in error, pleose immediotely notify the sender by email and delete it from your files. 1 Dave A From: Sent: To: Subject: Attachments: Dave Argo Wednesday, June 28, 20L7 L:48 PM ' bruce.bearcreek@comcast.net' Eastbank Auto Repair Shop - Permit #BLCO-02-l-7 -4594 IBC Table 616.5.pdf Bruce Sorry that it's taken me a couple of days to get back to you on fire ratings at doors into the exit stair at the Eastbank Auto Repair Shop. For your benefit, I have copied a few remarks from the building code report which was run when we originally conducted our plan review for this project: STAIRWAY ENCOSURE -o Openings into the exit enclosure are required to be l-hour fire assemblies - lBC, Table 616.5 ¡ Openings into enclosure are limited to those necessary for exit access to the enclosure from normally occupied spaces and for egress from the enclosure. (Sec. 1023.4) ¡ Doors shall be self-closing or automatic closing. (Sec. 716.5.9) ¡ Exit enclosure must discharge directly to the exterior of the building. (Sec. 1023.3 and L028.1) Please refer to the attached PDF which shows lBC, Table 7L6.5 which indicates that doors located at the 1-hour rated walls enclosing the interior stairway are required to have a 1-hour minimum fire assembly rating. The upstairs exit door into this stairway does not need to be equipped with panic hardware, and it also doesn't need to swing in the direction of egress because occupant load is minimal (7 persons). Hope that this information is helpful to you DaveArgo Plans Examiner {iarfæld County Community Development Department 708 *th Street, Suite 407 Glenwood Springs, CO 81601 Tel: 970-945-8272 Ema il : da rg o @ go rfi eld-county, com Web : go rfield-cou nty.com CONFTDENTIALTTY NOTICE: This emoil communicotion ond ony files transmitted qlong with ¡t are ¡ntended only for the person or ent¡ty to wh¡ch it ¡s oddressed. tf you have received this email in error, pleose ímmediotely notify the sender by email and delete it from your files. TYPE OF ASSEMBLY REQUIRED WALL ASSEMBLY BATING (hours) MINIMUM FIRE DOOF AND FIRE SHUTTER ASSEMBLY RATING (hours) DOOR VISION PANEL SIZEb FIRE-RATED GLAZING MARKING DOOR VISION PANELd MINIMUM SIDELIGHT/ TRANSOM ASSEMBLY FATING (hours) FIRE-RATED GLAZING MAFKING SIDELIGHT/TRANSOM PANEL Fire protection Fire res¡stance F¡re protect¡on Fire resistance Fire walls and fire barriers having a required fire-resis- tance rating greater than t hour 4 3 See Note b D-H-W-240 Not Permitted 4 Not Permitted w-240 3 30 See Note b D-H-W-180 Not Permitted 3 Not Permitted w-180 2 !'/,100 sq. in. <100 sq. in. = D-H-90 >100 sq. in.= D-H-W-90 Not Permitted 2 Not Permitted w-120 lr/,lrl,100 sq. in. <100 sq. in. = D-H-90 >100 sq. in.= D-H-V/-90 Not Permitted 1r l,Not Permitted w-90 Enclosures for shafts, interior exit stairways and inte- rior exit ramps. 2 7r l,100 sq. in. <100 sq. in. = D-H-90 > 100 sq. in.= D-H-T-W-90 Not Permitted 2 Not Permitted w-120 Horizontal exits in fire walls" 4 3 100 sq. in. <100 sq. in. = D-H-l80 > 100 sq. in.= D-H-W-240 Not Permitted 4 Not Permitted w-240 3 30 100 sq. in. <100 sq. in. = D-H-l80 > 100 sq. in.= D-H-W-180 Not Permitted 3 Not Permitted w-180 Fire barriers hav- ing a required fire- resistance rating of t hour: Enclosures for shafts, exit access stairways, exit ac- cess ramps, inte- rior exit stairways and interior exit ramps; and exit passageway walls 100 sq. in." <100 sq. in. = D-H-60 >100 sq. in.= D-H-T-W-60 Not Permitted I Not Pemitted w-60 Fire protection Other fire barriers I ,lo Maximum size tested D-H ,lo D-H Fire partitions: Corridor walls I 0.5 l, bt7 ,lro Maximum size tested Maximum size tested D-20 D-20 Itb ,1, D-H-OH-45 D-H-OH-20 Other fire partitions 1 0.5 t/o llt1 Maximum size tested Maximum size tested D-H-45 D-H-20 tlo ,1, D-H-45 D-H-20 F¡RE AND SMOKE PROTECTION FEATURES TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS 140 (continued) 2O'I 5 INTERNATIONAL BUILDING CODE@