Loading...
HomeMy WebLinkAboutField Maintenance Report Lot # 5 April 14- 15IECCI ENGINEERING Cronk Construction Inc.Cronk Construction inc. 1129 -24- Road, Grand Junction, CO 81505 • Phone (970) 245-0577 • ccigj@msn.com April 16, 2015 Clay Crossland Basalt Management Inc. PO Box 710 Basalt, CO 81621 970-927-4704 crosland@bta.bz Re: Lot 5, Big R Commercial Park, Highway 6, Rifle, CO Dear Mr. Crossland; Enclosed please find the Scheduled Field Maintenance Report for the Onsite Wastewater Treatment System currently serving the above referenced location. The system was inspected on April 14, 2015. The system, as designed, employs advanced treatment technology in the form of a recirculating packed bed textile filter treatment system (AdvanTex AX20 treatment unit). This type of system requires an ongoing operation and maintenance agreement with an authorized service provider. I have included an invoice for the current 2015 maintenance agreement. The next inspection is scheduled for October, 2015. At that time, it is recommended that you have the septic tank pumped. Other recommendations are included on the Report. The current maintenance agreement with CCI Engineering expires on March 13, 2016. Sincerely, Thomas A. Cronk, P.E. TAC/pjsc Enc. Page 1 of 1 Grand Junction (970) 245-0577 • Glenwood Springs/Aspen (970) 640-5029 • Montrose/Delta (970) 640-5029 ccigj@msn.com AdvanTex® O&M nnaNuAu. PART 1: START-UP AND ROUTINE MAINTENANCE Scheduled Field Maintenance Report Field Maintenance Report Property Owner pH (6-9) DO (2-6) Current Co „ TechNotan see Add,ess °, 8 5 G enrvc.\ C 1.-e...\ e. \ , COT\e g \t.. Q Contact Phone Ax Site ID Y County ID a Pod F RTU a/UL M '—Tu. w.,%\0 Sart-up Date Retrieve O&M Into Dally flow Recirc ratio Timer settings: Perform Field Sampling/Observations NTU (15 ± NTUs) pH (6-9) DO (2-6) Odor of Sample Typical X Musty ❑ Earthy ❑ Moldy Non -typical ['Sulfide ❑Cabbage ❑Decay Oily film In PVU ❑Yes gNo Foam In tank ❑ Yes [Ni No Check Control Panel Recirc Amps 2O9.2V Discharge Amps 5.30 2.09.2V Audible and visual alarms Dial tone (telemetry only) Inspect/Clean Pump System P' OK ['Yes El No Inspect Ig C4 Riser/Lid Splice Box Float Cords Floats Pump Biotube. Filter Btotube Pump Vault Recirculating Splitter Valve Clean Measure Sludge/Scum Sludge Scum 1st Compartment Current /at „ Previous 6111.. /0 Current Co „ 3 ., 2nd Compartment Current O"-,_ Previous o - z" Current 0." Previous O" Inspect/Clean AdvanTex Filter Odor: (Normal ❑Pungent Biemat:rr►dd1 'Normal ❑Excessive Bridging/Ponding: LLNone/Minor ❑Excessive Inspect/Clean Discharge Pump System Inspect Riser/Lid Splice Box Float cords Inspect/Service Other System Components Inspect Clean Disinfection Equipment ❑ ❑ InspectLaterals/Orifices L2�I lEl Pod Bottom Intake Vent Floats Pump Clean Inspect Clean X' ❑ X Inspect Clean Dispersal Laterals/Orifices ❑ Observations Additional Services Rendered ❑ Cleaned textile sheets? ❑ Replaced UV items? ❑ Replaced/Used other Items? Final/Safety Inspection �y RSV reinstalled X Lids bolted on gManifold reconnected; flush valves closed [Control panel reactivated Summary/Recommendations IXTreatment system is performing; no further action necessary. ❑ Tank needs pumping IOtheR �0.rk S\+ou.\� �, Q••••.••,"%P atr 0LA-0\5e.r Comments k'Da..+ sor. reab.S Cec.4-4.t1nr&�1e \.%c,5. (1,.\\�_.5 "4 .£5\s.:4-54)\ tea A- aa -s re+r"Su1� ivec��tr-e 1o4V , 30 Q°"-"4- signature owtYSignature Date —' 77 C L Ft comnieted form to 1.866.384-7404 OY/IH /l5 ❑ Call for service c.eec. • AIM -OM -ATX -1, Rev.1.0, 2/08 • Copyright Orenco Systems, Inc. Property of Orenco Systems Inc. 00 not reproduce or distribute without written authorization from Orenco: 800-348-9843.