HomeMy WebLinkAboutGeotechnical Engineering Report 07.19.2017Air CTLITHOMPSON inarsamminsw July 19, 2017 Phil Vaughan Construction Management, Inc. 1038 County Road 323 Rifle, CO 81650 Attention: Mr, Phil Vaughan Subject: Geotechnical Engineering Consultation Garage Building Vaughan Residence 1038 County Road 323 Garfield County, Colorado Project No. GS05694.000-145 This letter provides our geotechnical recommendations for the planned garage building to be constructed at 1038 County Road 323 in Garfield County, Colorado. Planned building construction, anticipated subsurface conditions, and our foundation recommendations for the building are provided below. Planned Construction The garage will have plan dimensions of 30 feet by 86 feet. Walls will be framed with 2 x 6 wood studs and the roof system will be comprised of wood trusses that span across the shorter dimension. The building will have five overhead doors on the south wall, providing access to four parking bays. The finished floor slab elevation in the building will be 5309 feet. Existing ground surface within the building footprint varies from about 5307 to 5310. The preferred foundation is a concrete slab -on -ground with turned down edges. Subsurface Conditions Subsurface conditions are anticipated to be similar to those observed in exploratory pits excavated as part of our field investigation for a 2004 addition to the Vaughan Residence. Subsurface conditions consisted of 2.5 and 6 feet of silty sandy clay underlain by clayey to silty gravel with basalt cobbles and boulders to the total explored depth of 7.5 feet below existing ground surface. Free ground water was not observed in the exploratory pits. Site Earthwork Stripping depth will likely average about 6 inches to remove topsoil and organics from below the planned building. We believe fill thickness of 2 feet or Tess will be required to achieve subgrade for finished floor. Significant overlot grading cuts and fill are not anticipated for building pad construction. 234 Center Drive { Glenwood Springs, Colorado 81601 Telephone: 970-945-2809 Fax: 970-945-7411 Excavations for utilities and foundation walls can be accomplished using conventional, heavy-duty construction equipment. Excavation sides will need to be stoped or braced to meet local, stat: and federal safety regulations. We believe the clay will classify as a Type B soil and the gravel will classify as a Type C soil based on OSHA standards governing excavations. Temporary slopes deeper than 4 feet (if required) should be no steeper than 1 to 1 (horizontal to vertical) in Type B soils and 1.5 to 1 in Type C soils. Contractors should identify the soils encountered in the excavations and refer to OSHA standards to determine appropriate slopes. Structural Fill The silty sandy clay soil at this site possesses the potential for moderate consolidation when wetted under load. We recommend placement of at least 1 foot of structural fill below the slab -on -ground foundation. We recommend the granular, structural fill consist of an aggregate base course, such as a CDOT Class 6 or similar soil. The subgrade surface that will support structural fill should be scarified to a depth of at least 6 inches, moisture -treated, and compacted. Structural fill should be moisture -treated to within 2 percent of optimum moisture content and compacted to at least 98 percent of maximum standard Proctor (ASTM D 698) dry density. Water required to increase the structural fill soil moisture content to the specified moisture content should be uniformly mixed into the fill soil prior to compaction. We recommend loose fill lifts of 10 inches or less. The actual thickness of fill sifts that can be properly compacted will depend on the type of compaction equipment. Slab -on Ground In our opinion, a slab -on -ground is a reasonable system for the foundation and floor of the proposed garage at this site. We recommend supporting the slab on a 1 -foot thickness of densely -compacted, granular structural fill. Design criteria for a slab -on -ground foundation/floor system are provided below. 1. The slab -on -ground foundation should be constructed on a minimum 1 -foot thickness densely -compacted, granular structural fill. 2. The slab should be heavily reinforced and preferably in a single monolithic configuration to help maintain its integrity in the event of ground movement. The slab turned down edges should be designed for a maximum allowable soil pressure of 1,500 psf. 3. Modulus of subgrade reaction (Ks) is normally used for a slab -on - ground design. The modulus of subgrade reaction is dependent upon the compressibility of the foundation soils and the size (or PHIL VAUGHAN CONSTRUCTION MANAGEMENT VAUGHAN RESIDENCE ADDITION PROJECT NO. GS05694.000-145 C:lllssrslcdowning19ox1Projects1Glenwood Springs - ProJects1GS05694.000114613. Letters1GS05694.000 146 L2.docx 2 effective loaded area) of the foundation. If the entire slab foundation is uniformly loaded, then a KS value of 200 pci. A friction coefficient of 0.45 can be used for lateral resistant between concrete and granular structural fill. 4. Lateral Toads can be resolved by evaluating passive resistance using an equivalent fluid density of 325 pcf for the onsite soils, provided the backfill is compacted and is not removed. 5. Soils beneath the foundation must be protected from freezing. The granular structural fill and natural soils are not significantly susceptible to frost heave. We recommend the perimeter of the slab be turned down to extend at least 24 inches below exterior grade. The Garfield County building department should be contacted for specific frost depth requirements. Surface Drainage Surface drainage is critical to the performance of building foundations and slabs. Proper surface drainage can help control the amount of surface water that penetrates and wets the subgrade soils below the slab. The ground surface surrounding the building should be sloped to drain away from the building in all directions. Roof gutters and downspouts should be provided. Limitations This geotechnical engineering consultation was provided in a manner consistent with that level of care and skill ordinarily exercised by geotechnical engineers currently practicing under similar conditions in the locality of this project. No warranty, express or implied, is made. If we can be of further service in discussing the contents of this report, please call. Very truly yours cc: Via email to phik pvcmi.com Reviewed by: es D. Kellogg, P.E. 'vision Manager PHIL VAUGHAN CONSTRUCTION MANAGEMENT VAUGHAN RESIDENCE ADDITION PROJECT NO. GS05894.000-145 C:1UeerslcdowningiSox112rojccls1Glenwood Springs • Projocts1GS06694.000114613. Letters1GS05694.000 145 L2.docx 3