Loading...
HomeMy WebLinkAbout5759L 5759 (iARI?ELU ('OUN7]' RUII.UING, SANIZATIONnrul PLANNING UGI AR 771f7iN7- 109 91h st cel smlc 303 Glenwood spring..,, Colorado 81(411 (303) 945-8212 ]ub Address 4335 County Road 113, Glenwood Springs Nature of work Building Permit Use of llnildu,g Single Family Dwelling w/Double Garage OwnOr Unda & .Terry Young Contractor Yost Construction Ainonnton>crn,x.R1,745.68_ nate December 26, 1995 Permit: 1057.99 Plan 687.69 Paid $643.18 S. Archuleta (3crk BUILDING PERMIT APPLICATION ' GARFIELD COUNTY, COLORADO Applicant to complete numbered spaces only. PERMIT NO. S75 PARCEUSCHED NO Jae ADDREss N ,St /7V 1 LEGAL�� DESCR. ILOTNO, SUBDIVISION Cid IJ S jL• - u lI S5 F ZJ�Q 1 OWNERL_ Cq)f P l WK PHO 3 CONTRACT ADDRESS9 q• — W!5 p .q LICENSE N C;—OoD 4 ARCHITECT OR DESIGNER ADDRESS PH, LICENSE NO. 5 ENGINEER ADDRESS PH, LICENSE NO. 6 S.FOFBUILDINGd(7051 HEIGHT NO OF FLOORS 7 USEOFBUILDING 8 CLAss OFWORK: NEW oADDITION oALTERATION oREPAIR UMOVE oREMOVE. 9 DESCRIBE WORK; 1 J (• ,^ J '�j ` v\ 1 /, �, y` LO �t C_ IC w /Q�l )3lft' 10 GARAGF��1 GLE DOUBLE CARPORT SINGLE DOUBLE DRIVEWAYPERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN 7A 11 VALUATION aR Ma. ADJUSTED VAL3)./ Jt 7 PLAN CHECKF PERMIT FEE SPECIAL CONDITIONS: SCHOO P CT F E O O �, " NO. OF BUILDINGS ON PARCEL USE OF BUILDINGS NOW ON PARCEL TOTALF D 5 OCC. GR CONST. TYPE NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING, NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS[FIRE COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVEOIL AUTHORITY TO VIOLATE OR CANC L THE PROVISIONS OF ANY OTHER STATE OR CAL EGV TING C STR CTION OR THE PERFORMANCE OF C STR 10 Da �— WATER SUPPLY DATE PERMIT ISSUED SPEeinLAIPno ALS REHIRED RECEIVED Noi REQUIRED ONING EALTH DEPT. ,r DEPT. REPORT SETBACKS HAZgRD 51 re e , nn[racior or uthori d agent h rea d .r noNDe above gDepertmentApprava/tla[e PIa ping Departmen[Appmval [ EANUF . HOMEBuil SDS ! �JOI �' d AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES, THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTERES Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE jl I 1 _ 3. 1 C N 7 COUNTY OF GARFIELD — BUILDING DEPARTMENT 2014 Blake Glenwood Springs, Colorado Phone 945-8241 Job located at A,1 -2 -3 12 �i 3 Permit No. Sr. have this day inspected this structure and these premises and found the following violations: '/a (pro z % /✓/i�5� S�.:OS AN Fi e>� �" U ^�� A4 � — I�rn2"4--i 71'��-!✓ ST- F b E: �i�cc� ..�� You are hereby notified that no more work shall be done upon these premises until the above violations are corrected. When car- rections have been made call for inspection. Date 199 & p o�5�8241 m �` GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: I I 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes _____ Nou, Not necessary for this project _____ , 2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses? Yes _ _ No _____n, Not necessary for this project _____c2, 3. Does the site plan indicate the location and direction of the County or privXr- oad accessing the property? Yes No _____(u Not necessary for this project 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes r'C-_ No _____m Not necessary for this project _____(2) S. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes _y__ No _____cu Not necessary for this project ----- 6. Do the plans indicate the size an location of ventilation openings for theic, roof joist spaces and soffits? Yes __ No _____n, Not necessary for this project _____(2) 7. Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per squar foot in Garfield County) floor loads and wind loads? YesNo _____,,, Not necessary for this project (2) 8. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes _4__ No _____()) Not necessary for this project _____(2) 9. Does the building section drawing include size and spacing of floor joists11 studs, ceiling joists, roof rafters or joists or trusses? Yes _ ___ No----- m Not necessary for this project _____>, 2 10. Does the building section drawing or other detail include the method of p7-7 itive connection of all columns and beams? Yes 7 __ No _____,n Not necessary for this project _____(2) 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes -X-__ No _____(i) Not necessary for this project _____(2) 12. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or pl ase 1I LPA certification? Yes _____ No X___(i) Not necessary for this project _____, , 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Cha er 37? Yes __ No _____u, Not necessary for this project _____(p) 14. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements coTI with the requirements of the Uniform Building Code? Ye _ No _____(j) Not necessary for this project _____(2) 1.5. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes,A___ No ,u Not necessary for this project _____(3) 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclopures and specify safety glazing for these areas? Yes No _____eu Not necessary for this project _____(2) 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters i,n . icated on the plan? Yes _____ No_,,, Not necessary for this project _____(2) 18 Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from that association, if required by that association, prior to submitting an applica ion for a building permit? Yes _ _ No _____n, Not necessary for this project _____(2) M 19. Have two (2) complete sets of constructions drawings been submitted with I application? Yes _ _ No -----„) Not necessary for this project-____(2) 20. Is this an applicatigrl for the placement of a manufactured home? Yes ----- No �_ If yes, have you specified the size of the unit (min. 20ft x 20ft); live roof load (min.40#); wind design (min. wind speed of 80 mph & 15 lb. wind load); foundation design; method of anchoring? Yes ----- No -----m Not necessary for this project _____(2) 21. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No----- (3) 22. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield Building Depa tment? Yes__ No ----- 23. Do you understand that approval for design and/or construction chan s are required prior to the application of these changes? 'Yes /V-- No -----(A) 24. Do you understand that the Building Department will collect a "Plan. Review” fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School impact" or "Septic system " fees required, at the time you pickup your building perp ? Yes �-_ No 25. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection_prrior to receiving a Certificate of Occupancy and occupancy of the building? Yes-- No --__-(3) 26. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the project complying with the Uniform Codes'. YesNo (3) (CONTINUED ON NEXT PAGE) 4 I hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. s t Phone: 5-33;13—_(days); S els —9,(0 Project Name: Project Address: (ty ?� )) 3 date evenings) Notes: (1) If you have answered "No'" on any of these questions you may be required to provide this information at the request of lite Building Official prior to beginning the plan review process. Delays in issuing the permit are In be expected. Work may not proceed without the issuance of the permit. (2) 'If you have answered "Not necessary for this project on any of the questions and it is determined by the Building Official that the iuforrnation is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review processand not reviewed until required information has been provided and the application rotates again to first posillon for review. B. Delay in Issuance of the permit. C. Delay in proceeding with construction. (3) If you answered "No" to this question lite circumstances described in lite question could result in a "Stop Work Order' being issued or a'Certificate of Occupancy' not being Issued. PerApp02.95 Effective August 15, 1995 5 Certificate Of Occupancy No. 2803 Building Department Garfield County, Colorado No change in the character of occupancy of a building shall be made without a Certificate of Occupancy - (IIBC Sec. 502) This certificate is issued pursuant to the requirements of Section 307 of the Uniform Building Code certifying that at the time of issuance, this structure was in compliance with the various codes adopted by the County regulating building construction or use for the following: Use Classification Single Family Dwelling w/Double Garage Group R-3, M-1 Type of Construction Owner of Building Jerry & Linda Young Building AddreSS4335 County Road 113, Glenwood Springs, CO Contractor Jeff Yost Building Permit No. V—N Address 0041 Pinon 5759 Zone District New Castle, CO Locality Baby Beans Sub, Lot 4 Address 995 Brush Court, Glenwood Springs, CO Date June 4, 1996 Issuance of a Certificate of Occupancy shall not be construed as an approval of the provision of this code or of other ordinances of the jurisdiction. Certificated presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. (UBC Sec. 307(a)).