HomeMy WebLinkAbout3248GARFIELD COUNTY DEPARTMENT OF DEVELOPMENT
BUILDING DIVISION
3rd Floor, Courthouse
100 8th Street
Glenwood Springs, Colorado 81601
(303)045-8212
Jo6Address 1950 County Road 311 - New Castle
Nature of Work construction
Use of Building 901141H flouble Card e
Owner Andrew Ri nna
Contractor Owner
Amount of Permit:$ 142.70 pate: April 1.8, 1986
Permit Fee $ 86.50
Plan Check Fee 56.20
White - Treas.
Canary - Office
Pink - Applicant
Gold - Duplicate
Patricia Jones McPherson
Clerk
GARFIELD COUNTY
APPLICATION FOR BUILDING PERMIT
a�
a
WROOlalIRIP0,
FILING # LOT #
TAX SCHEDULE #
LEGAL, (SEC/TWN/RNG)
Mwafer lJlui
MAILING ADDRESS
CITY A),o_._,rA,4�
NAME
ADDRESS CITY
c
11y"lln VW
ADDRESS
CITY
v
PHONE LICENSE #
please print or type
BLOCK #
CLASS OF WORK
NEW ALTERATION ADDITION
DEMOLISH REPAIR MOVE
MOBILE HOME (make/model)
S.F. OF BUILDING S.F. OF LOT
# OF FLOORS HEIGHT
#OF FAMILY UNITS # OF BEDROOMS
INTENDED USE OF BUILDING
GARAGE: SINGLE_ DBL CRR PORT: SINGLE_ DBL
FIREPLACE
DOCUMENTS ATTACIIED _
WATER SUPPLY
DRIVEWAY PERMIT
SITE PLAN r•
BUILDING PLANS yl� I/
SANITARY SEWER CLEARANCE
ON SITE SEWAGE DISPOSAL PERMIT
OTHER DOCUMENTS (specify) _.
!!�- 'A AAA so
VALUATION iA9. &,Q,J
PERMIT NUMBER
DATE [�
NOTE: Show easements, property line dimensions
all other structures, specify north, and street
name. For odd shaped lots, or if space is
too small, provide separate plot plan.
# OF BUILDINGS NOW ON PARCEL
USE OF BUILDINGS NOW ON PARCEL
FRONT PROPERTY LINE
STREET NAME/ROAD NUMBER
CHECK IF CORNER LOT _
DESCRIPTION OF WORK PLANNED
I hereby acknowledge that I have read this
applicati and the hove is correct and 2
agree to mp1 wi 11 co ty ordinances
st law 're ilding construction.
A E
OFFICE USE ONLY
PERMIT FEE $ "5 PLAN CHECK FEE
TOTAL FEE $ p SCHOOL IMPACT FEE $
DATE PERMIT IS UED
ZONING DISTRICT
TYPE OF OCCUPANCY -___- I f
TYPE OF CONSTRUCTION ..-
S.F. OF BUILDING S.F. OF LOT
MAX. HEIGHT l ROAD CLASS.
SETBACKS FROM n6PERTY LINE:
FRONT_l_�[_
REAR �_ RIGHT LEFT
OFF STREET PARKING SPACES REQUIRED
APPROVED:
FLOOD HAZARD
CERTIFIED BLDG ELEVATION
SPECIAL CONDITIONS
PROBLEMS WITH PERMIT
ADDITIONAL INFORMATION NEEDED
CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR
OR ENGINEER
APPROVED:
PLANNING DEPARTMENT DATE
PERMIT N0. ADDRESS 0�W„N�ERLCAV ��jJ_
_,
THE FOLLOWING ITEMS HAVE EITHER BEEN OMITTED FROM YOUR PLANS OR DID NOT COMPLY WITH THE
PROVISIONS OF THE UNIFORM BUILDING CODES.- PLEASE CHECK ALL "x"ed ITEMS BEFORE BEGINNING
CONSTRUCTION. All references are 1982 UBC unless otherwise noted.
I. y
2.1(
3.K
4.�
6.
7.X
9.
9.
10
11
12
13
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
29.
30.
31.
32.
33.
34.
35.
36
3714
38.
39.
40.
41.
42.
Structural concrete for footing and foundations and load bearing slabs on grade is
is required to be 3009 PSI within 30 days. 2604(c)E and Standard 26-1
Reinforcement steel for footings: 2#4 rebars continuous
for foundations: 2#4 Rebard at tap & bottom of wall
Frost protection for footings: 30" minimum to the TOP of the fpoting. 2907(a)
Foundations shall extend at least 6 inches above grade. 2907(a)
Provide for the drainage of surface/runoff water away from the building. 2905(f)
Foundation plates on mud sills shall be redwood or pressure treated wood. 2516(c)? -
Foundation plates shall be bolted to the foundation with anchor bolts a minimum of
1/2" x 7" - 6 feet on center: 1/2" x 15" in unreinforced grouted masonry. 2907(e)
Solid blocking is required between ,joists at all bearing points. 251*1(d)3
With joists @ 24" on center: minimum plywood thickness allowed is 3/4". Table 25-R-1
Joists are insufficient for the spans: Minimum X -D.C. Table 25 -U -J-1
Beam insufficient for loads/spans X MINIMU sFT' ie allowed. Tables 25 and 2304
A glu-lam or a steel beam is required at Tables 25 and 2304
All walls bearing two (2) floor loads are requ re to e a minimum of 3 x 4's or 2 x E
studs with a maximum spacing of 16" on center. 2518(g) 1,3
Shear bracing required: both sides of each corner and every 25 lineal fleet. 2518(8)°
Brick ties; 1" x 22 gauge, spaced a minimum of 16" on cneter each way. UBC Standard
Ceiling/floor headroom is required to be a minimum of 7'6" in all rooms except kitcher
halls, bathrooms and storage areas which may be a minimum of 7'0". 1207(a
Minimum stairwell headroom measured from the nosing of tread is 6'6" 3305(p
ALL STAIRS: MAXIMUM rise - 7 1/2"; MINIMUM run - 10"; MAXIMUM overall variation with;
a flight of stairs is 3/8". 3308(c) (RESIDENTIAL EXCEPTION - 8" Rise & 9" Tread)
Minimum width of stairways in a single-family dwelling is 30". - 330e(b)
Handrails: minimum height - 30"; maximum height - 34", handgrip portion shall be not
less than 1 1/4" or more than 2 inches in cross sectional area. 3306(j)
Residential guardrails: minimum height -36 ".
Open guardrails and stair railings shall have a pattern such that a sphere 6" in
diameter cannot pass through. 1711 (EXCEPTION -ISOLATED COMMERCIAL MAY BE 12").
Underfloor/crawl space ventilation is required. 2516(c)6
Access to underfloor areas shall be a minimum of 18" x 24"
Windows in unfinished basements: 4' x 4' with a maximum sill heigk 'of 44" or area,
used for storage only and plans marked "STORAGE AREA ONLY". 1204 (Item 26, below;
Windows located withi.n 18" of the floor and 18" or wider' are required to be tempered
or protected. 5406(d)6 & 7
EVERY bedroom below the fourth (4th) floor without a door opening to the outside shall
have a least one window that meets the following requirements:
MAXIMUM sill height:. 44 inches
T�MINIMUM net clear opening width: 20 inches
-MINIMUM net clear opening height:. 24 inches
INIMUM net clear opening: 5.7.square feet 1204
Provvfde combustion air for furnace/water heater. UMC 607
Provide floor drain for water heater or pipe P & T relief valve to the outside of the
building. . UPC 1007
Furnace and water heater must each be removable without moving the other. UMC 703
Each water closet shall have minimum clearances of 24" in front and 30" width (15' cel
line to nearest sidewall). Sec 511
Bathrooms without windows shall be equipped with a fan vented to outside air. Sec 705
Attic access required: minimum opening: 22 x 30 inches. 3205(a)
"Fireplace hearth: minimum depth in front of opening is 16 inches, sides 8 inches. 3i
Attic ventilation required; minimum 11150th of the vented space. 3205(c)
One hour firewall with a self closing 1 3/8" solid core door is required between the
house and the garage. 503(d)
A "wired in" electrical smoke detector is required in all bedroom access areas; for
second story bedrooms, locate the detectors at the top of the stairway. Any other
alarm trips other alarms. 1210(a)
Headers over doors & windows will be on edge. Sec 2517(g)5
P� - V
THE ABOVE REQUIREMENTS.
Y,
-. - _ lo..: rt Y v�`y'�—�$Gf}N$T ^...._
''y y 11j -ST T -xCe? AUCi1i n? ^fir' PR1VgTEpRO
cNsA i%-, fiANT a- eL[t rnrsPEclor
Nr: TH r PLANS, r ; TtiE. Mpg ...�"
�a��'F� PFr✓
m
rp
c� O
r
m
�� a
w
4 009 m
o u� 0 Z
�;o
4DZm Z
��'r m
&Nm M
'opm Z
aao%
m0 O
a, 3
o v
Z
`o
;1
m
r
c�
r
N
o am
—OF m
arum Z
wu
mz� Z
LTI 7 m
c m
aye ;u
� o x
mc)
0000
"k $
a,
o v
n
z
C.
Q
i
� w w
0 0 t
0 0 0
2
CL m
xo
Z motO
w
d' m cW
wN
E-Ov
Z ¢�w
z sumo
moV
0
a o3
� W
C}
Aj
i
s
—_ . _. _......
Zx4
IG' _nom WCL s �z orc r Y�2
j,
Gzv:. S:reeYl i. Scewa�LS:
Hasa
I
_..A
Has,.,
r
la ,r rN�-
_
'x 454756
__..-...
TlZurs ,C�SrrJ
..
if r.n
__
e.. _..
- .. ..-
f
_.
I Al
r
r'AN
3.
977 ko
,