Loading...
HomeMy WebLinkAbout5253GARFJEL» COUNTY BUILDING, SANITA170N and PLANNING DEPARTMENT 109 8th Slrccl Suite 303 G1cnwood Springs, Colorado 81601 (303) 945-8212 No. 5253 JobAdd,.,.,. _____ 6_5_3_8_C_o_u_n_t_y_R_o_a_d_3_3_1_,_s_i_l_t _________________ _ Nalure ofWmk. ____ B_u_i_ld_i_n~g_P_e_rm_i_t _______________________ _ UseofBuildin.0•---~S~i=·n~g=l~e-'-F,,a,,m"i"'l~y--"Dw=e"'l"l"i"'n"'g"-'w""/"D"-0"-u"b"l"""e--"G"a~r,,a,.g.,,e~----------- Owna ______ ~R~o~b~e~r~t~~...__V~i~s~e~k"'-----------------------~ Contracto[' _____ O'-'wn=e:cr'------------------------------ Amount of Penni! s. __ .,.1,_,·,,,1"'4~1~·~8~0~=~~---Permit: 692. 00 Date. __ A_u~g"u_s_t_l_5__:_,_1_9_94 _________ _ Plan 499. 80 Paid $368.84 7-26-94 S. Archuleta Clerk GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT PERMIT NUMBER S:J. ~3 DATE ---=~--~/ 5::.-....-_-f.._$<!,___ __ I Assessor's Parcel I,! please print or type TO BE FILLED OUT BY APPLICANT --ADDREss t. 5'.!.R er?. J:Jt S'. I+- FIDING # LOT /I ____ BLOCK # 1'AX SCHEDULE # f?.oo.: 0,o9 ;>"'.S"-:i,92.. LEGAL (SEC/TfvN/RNG) .. +./... •• u CLASS OF l/OPJC NEW _ _$,)<1.L__ ALTERATION __ _ ADDITION ___ _ DEMOLISH ____ REPAIR MOVE MOBILE HOME (make/model) S.F. OF BUILDING _____ S.F. OF LOT ____ _ # OF FLOORS HEIGHT _______ _ # OF FAMILY UNITS # OF BEDROOMS ---- INTENDED USE OF BUILDING GARAGE: SINGLE DBL v/ CARPORT: SINGLE DBL FIREPLACE DOCUMENTS ATTACHED WATER SUPPLY __ ---Jf?~~"-"~~-~j~l~.~~·~,__,_i.,J"'-"'L~V,__ ______ _ DRIVEWAY PERMIT ___ 11'.!:.l>-o:.e.-.;· •L'-"--'-';..,::i.__,,,_,Q'-';'--'-. "-""'"--'L.,=---- SITE PLAN ------"~-~,,,__,oe....::·'--'::::::'----------- BUILDING PLANS ___ "t...._.=.__..L_,_l.r._,,,1~·~'--------- SANITARY SEWER CLEARANCE ----------'----- ON SITE SEWAGE DISPOSAL PERMIT --------- OTHER DOCUMENTS (specify) * p~,,"~-rq FT 1.111t:: a:z:ov"' PLOT PLAN NOTE: Show easements, property line dimension~ all other structures, specify north, and street name. F'or odd Shaped lots, or if space is too small,,. provide separate plot plan. # OF BUILDINGS NOW ON PARCEL -------- USE OF BUILDINGS NOW ON PARCEL -------- 'S ~e ,atJpU P.,<L,,;..e 171, .,,~~.J·'IB' ::h.J; Yr'f. '11' t/Pr.unr. /t"oo-@ 1rr = 1?, 75'(.0 #.J 11rr. &IM.. "Irr~ If'· e~ = 7, 1~ 'Yf ~r. (iflllt.. ~ 4/~ IS"· n-.. /J1 1aCJ·1 '2.. I /I~ '127-~y FRONT PROPERTY LINE STREET NA/iE/ROAD NUMBER ----------- CHECK IF CORNER LOT DESCRIPTION OF WORK PLANNED --------- I hereby acknowledge that I have read this application and the above is correct and I agree to comply with all county ordinances and st regula ing building constructior z. SIG FOR OFFICE USE ONLY VALUATION .~-/,.~"ft~~-:!;';;;!;;;.!--,;;;:;;;--;~'Hj'15J;;C?J­ PE RM I2' FEE $ FLAii CHECK FEE !'.$--1.4-~'-.,..--- TOTAL FEE $ ''~'· t/'OscHOOL INPACT DA1'E PERMIT ISSUED--------------- ZONING DISTRICT ~fp.·~_,__-t;..,R,,_~_,f?,""-'Dc::.._ __ ~-""'"-----­ TYPE OF OCCUPANCY _._f(_,,__· 3......,.,,_._f'1-'--.--f-~----- TYPE OF CONS1'Rf!H.ION V f./ S. F. OF BUILDil/G &2 Oc( S. F. OF LOT If I ,4C_. /--- MAX. HEIGHT /,'.' · ', ·• · !· ·· ROAD CLASS. (0 c. p,1 p, SETBACKS FROM PROPERTY Ll'NE: FRONT } C>Q /{.f. + REAR 3-oo ff + RIGHT "). uO f!..1:. + LEFT 300 (f:..±_ OFF STREET PARKING SPACES REQUIRED FLOOD HAZARD ---------------- CERTIFIED BLDG ELEVATION ---------- SPECIAL CONDITIONS ------------- PROBLEMS P!ITH PER/iIT ----~------- ADDITIONAL INFORMATION NEEDED _______ _ CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR OR ENGINEER ----------------- "G-$-f'/ APPROVED: /M-=-J~J'-">L.Ya;-"'-=' ,__. ___ _.fl-'--'--2-'-·-Jq'--'·Lf_1 - DATE P.GANNING DEPARTMEllT DATE I 1,. .. •-- 'i \• ~ i. I;_··,. '' I i : ,, .1 . GARFIELD COU~TY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION ADDITIONS ALTERATIONS ·and . MOVED BUILDINGS ~ In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the .. discovery that required information has not been provided.by the applicant· may result in the delay of the permit issuance and in proceeding with building construction. The owner ot contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if.you have enough Information to design your project and ptovide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled 'Dwelling . · construction under the Uniform Building Code. Tirls book is available to you thtough this departmeut at our cost. Also, please consider using a design professional for assistance in your design and a construction . professional for construction of your project. To provide for a more understandable plan in order to detennine compliance with the building, plumbing and mechanical codes; applicants are requested to review the following check list prior to and during design. Applicants ate required to indicate appropriately and to submit completed check list at time of application for a permit: 1 ·····~··;;·~-·· ~-- \ i I ' , I .. i !:,,.." • I ' ... ' 11 . I: . I ~ I I 1 i' . : . I, ' ' 1. ls a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? · Yes ~-~ No ----<o Not necessary for this project -----"' .· 2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties) , streams or water cours~ · Yes _____ No ____ <1l Not necessary for this project _____ m . . I 3. Does the site plan indicate the location and direction of the County or privat:,JYad accessing the property? . . . . 4. 5. 6. 7. 8. 9. Yes_____ ·No -----<ll Not necessary for tlus p!oJect _____ ,,, Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building5ode or per stamped engineered design? Yes _.J.c..:_ . No -----<u. Not necessary for this project _____ 121 Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood andea~ Yes -----No _____ 01 Not necessary for this project _____ <21 Do the plans indicate the size an location of ventilation openings for the a~oof joist spaces and soffits? . . Yes ____ No -----<'' Not necessary for thIS project _____ <21 Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per squartyx>t in Garfield County) floor loads and wind loads? Yes -----· No -----<ll Not necessary for this project _____ <21 Does the plan include a building section drawing indicating foun~n, wall, floor and roof construction? Yes -----No -----<'' Not necessary for this project ____ <21 Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes-~ No _____ 1u Not necessary for this project _____ 12i 10. Does the building section drawing or other detail include the method : • of positive connection of all columns and beams? ; I 2 .: : , I r=:=====--===='-------;c:::;;-_ --------------,[ I • i 'I I:· I' -- I : I : I I 'i !_i< i' '' ',, ',, : I .I\. i I ':, . ' ';: ' ' '1 I v Yes-----No _____ en Not necessary for this project _____ 12i 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span ~een the ridge and the eave down to existing grade contours? Ye~ ----No __ 7 __ cu Not necessary for this project _____ c2i i 12. · Does the plan include any stove or zero clearance fireplace planned for installation including niake and model and Colorado Phase II certifications or phase U EPA certification? . . / --Yes -----No -~•1 Not necessary for this project _f:::c;1 ' 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 3 7? ' · Yes ____ No _____ 01 Not necessary for this project-~ 14. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements -comp~th the requirements of the Uniform B'L!ildin~ Code? Yes ____ . No ____ en Not necessary for this project _____ c21 '15, ·_ ·Does the plan include a window schedule or other verification that wind~rovide natural light and ventilation f~r all ~abitable rooms? Yes -----No _____ 01 Not necessary for this project _____ 12i 16. Do the plans indicate the location of glazing subjectto hu1nan impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclos~·and specify safety glazing for these ~reas? Yes_____ 1. 1 No _____ en Not necessary for this project _____ (2) ~ • I. . 17. Is the location of all natural and liquid petroleu1n gas furnaces, boilers and water heaters indicated on the plan? _ Yes--~ No _____ en Not necessary for this project _____ c21 18. Have two (2) complete sets of constructions drawings been submitted with t~lication? Yes_____ No _____ co Not necessary for this project _____ c2i 19. Have you designed or had this plan designed while considering buildiynd other construction code requirements? Yes -----No _____ ci1 .. 3 .. : ' i . ', ! i ' '' ' ,, . ' ' ", .· '··: . 20. Does, the plan accurately indicate what you intend to construct and · what will receive a final inspection by the Garfield Building Departme)lt? ' Yes ·.....t.c.: No ____ (3) 21. Do you understand that approval for design and/or construction changes ~ required prior to the application of these changes? Yes--~ No _____ (3> . 22. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Pe:t;piit Fee" as well as any "School impact" or "Septic system" fees required, at the tilne you pick up your building permly---Yes _____ . No _____ 1,, . ' 23. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occup~of the building? Yes-----· No _____ (3) · 24. Are you aware that the person signing the Pennit Application whether the "Owner", "Agent of the Owner'', "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the projec~plying with the Uniform Codes". Yes____ No _____ (,, I hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. · .. /;U;I sikature .. date Phone: <?'J (p-.S l'if (days); 1ll )-D-z..tJo (evenings) Project Name: \)L~LG {?~sr ;'&~ e Project Address: c £___ .Jj; 4 ·-:11 ··~·· " " "' ! ' ' '' ' 'i i Notes: (1) If you have answered "No" on any of these questions you may be required to provide this information at the request of the Bulldlng orflclal prior to beginning the plan review process. Delays In Issuing the permit are to be expected. Work n1ay not proceed without the lssua'.nce of the permit. If you have answered "Not necessary for this project" on any of the questions and It Is deterrnlned by the Dullding Olflclal that the Information Is necessary lo review the application and pl~l\s to determine minimum compliance with th• adopted codes, please expect the following: i' A. The application may be placod behind more recent applkatlons for building permits ln the review process and not reviewed untll required Information has been provided and the application rotates again to first poslllon for review. B. Deloy ln Issuance of the permit. C. Delay Jn proceeding wlth construction. (3) If you answered "No" to this question the circumstances described In the question could result In a "Stop Work Order" being Issued or a RCertiflcate of Occupancy" not being issued. PerAppOl.94 Effective May 1, 1994 5 <f?ohet + lft'sp /( {ps 3 f 3-31 lfJ Si'/ I, CC) ~1~ 5-_;_ .,,.;'->-'•'-""'-'•'·'·'""L;.''"' i 7 ~ ... ,~! .. '::/ / i i" I I I !, 11 I' 11 ,1 /I j, I II 11 'H.' .~., f .:,. , . ! 'j ~· ,. '• ,,;,','( 'i;;-·. ".,'-, ··./~-_.: ',!' t..'""-: .. ...'.l \· L( .' .--" '.' ·, ,.C,\ ,--, ',-- ,-~-":'/ 3 { "J .. •/",\'( "';' _;ig·.: ~~ .. -' ' . ! ,J:C' ..'~ ':, ·'i ~l-.-;_.; •'J.l,'."J, . \ (.'~ '/ ::,: . ,.,,· ::1:_ BfSi cofi· 1~· ,,,. ''6 J '" ,:: ' ··;'•,!' 4-~ ' ''f J ") .:-:~ 1 ~:i/ ·~[,'' .-: . .,,,, 'j.., ,,_. J. [ -,,, .-'·"', ~ rr-r cJber-l-\Ir "'s &/( C,s3 cf g 31 Rd S ,· / .f-1 Cd 'g)C,5 ' . ~j ;\ '.·i '~; '·'' - BUILDING 'PERMIT ~A FIELD COUNTY, COLORADO .. Date I~sued ~/}~ _q'fz0ned Area. . __________ ----.. Permit No._.;,[i!__ __ ~---~------- AGREEMENT Owner Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. Zoning Footing Foundation Plumbing-Underground Gas Piping Frame Plumbing-Rough Electric-Ru'': .. ,' -(by STATE i11 :·- INSPECTION RECORD Roof Covering Heating Ventilation Insulation 3-30 ·'is-' Final J.·/"J~ r. ~ ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR O~ EXTERIOR, UNDERGROUND OR ABOVE GROUND. · THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 10 9 8th Street, County Courthouse, Glen~ood Springs,' Colo, ' ·-·· --' .. , ,. Certificate Of Occupancy No. 2970 No change in the character of occupanc~' of a building shall be made l\ithout a Certificate of Occupancy -(UBC Sec. 502) Building Department Garfield County, Colorado This certificate is issued pursuant to the requirements of Section 307 of the Unifoqn Building Code certifying that at the time of issuance, this structure was in compliance with the various codes adopted by the County regulating building construction or use for the following: Use Classification Single Family Dwelling w/Double Garage .1d. p . N 5253 Bm mg enmt o. _______ _ --------------------- '/p Group r-3, M-1 V-N Type of Constn1ction _________ _ Zone District .. , .)RD ----- Owner of Building Robert E. Visek Address 65 38 CR 331, silt, co Building Address 6538 County Road 331, Silt, co Locality ___________ _ Address same --------Contractor Owner --------,=-----------~ By C&~ Chief Building Official Date December 17, 1996 Issuance of a Certificate of Occupancy shall not be construed as an approval of the provision of this code or of other ordinances of the jurisdiction. Certificated presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. (UBC Sec. 307(a)).