Loading...
HomeMy WebLinkAbout4555' .. --·:">'5· GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 (303) 945-8212 JobAddress ~-~_3_4_9_2_3_l_l_Ro_a_a_· ,,__N_e_w_C_a_s_t_l_e _____________ ~---------~ Nature of Work ___ B_u_i_l_d_i_n--'s"-, _P_e_r_mi __ t ______________________________ _ Use of Building -~~D~e"t~a"c"h"-e"d'°-G"-a"'r=-a=g-=e---=&---=S-=t-=o-=r-=acsg'-'e'--------------------------- Owner ______ S_t_e~p~h_e_n_._F_i_·s_he_r _______________________________ _ Contractor ~--~0wn~~e~r...,luH.,a,.r..,l~a""n"--W""'a"'l-"k"'e"'r ____________________________ _ Amount of Permit $ ~1~7-=8-=·-=2-=0-~~~~---­ P ermi t: 108.00 White -Treas. Canary -Office Pink -Applicant Gqld -Duplicate Plan 70. 20 s. Archuleta Clerk GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT PERMIT NUMBER 71.SS-b DATE '?-~{)-7.X please print or type 12 4 o o o'":::.-.... .2.17 TO BE FILLED OUT BY APPLICANT --ADDRESS .Jz/fJ.. SUBDIVISION ----------------· FILING # LOT # ____ BLOCK# TAX SCHEDULE # 'LEGAL (SEC/TfvN/RNG) !NAME . ,..; ------------- jMAILING DRESS IC TTY ----L-"--""""'--.!.-="+-"--IN J1!4E ---- f--!A_:_D_:_D_R.::E_s_s-=======;;:<=== CTTY &wn etjZl?aJ;,.d ft,!q,/,Re J--: iVA!1E ADDRESS iCITY 1-~HOl\TE LTCENSE # CLASS OF HOPJZ NEVI ,/7/ ALTERATION ADDITION DEMOLISH REPAIR MOVE MOBILE HOME (make/model) --/V7F- S .F. OF BUILDING .f}5 ~ ri.,_....--S.F. OF j_,QT _____ _ # OF FLOORS # OF FAMILY UNITS INTENDED USE OF BUILDING GJlJlAGE' SINGLE DBL CARPORT' S FIREPLACE DOCUMENTS ATTACHED WATER SUPPLY fa''A DRIVEfvAY PERM_I_T~-b~;(~f~C-,__,_, -,,_-'i---------- SITE PLAN ,_..-j BUILDING PLANS SANITARY SEWER CLEARANCE lt/'4- 0N STTE SEWAGE DISPOSAL PE-'R~M~I~T~~/1/-~lf~------ OTHER DOCUMENTS (specify) VALUATION PERMIT FEE $ ;og.oo p TOTAL FEE e' / 7 (?, "2-0 DATE PERMIT ISSUED N CHECK FEE$ """j't?.Z-0 SCHOOL IMPACT FEE $ A/IF ZONING DISTRICT ----"--C~-¥-~--------- T Y PE OF OCCUPANCY TYPE OF CONSTRUCTION A/ --'~'-'-"'-----c-=~ S.F. OF BUILDING ~~2-S.F. OF LOT "L .. (~a_c_, MAX. HEIGHT .,,.___; k' ROAD CLASS. ,....._.-. I SETBACKS FROM PROPERTY' LINE' FRONT $-4<k 0 REAR RIGHT LEFT OFF STREET PARKING SPACES REQUIRED ------- .... PLOT PLAN lVOTE: Show easements, property line dimensions, all other structures, specify north, and street name. For odd shaped lots, or i±-spac'e is too smal .. I, provid.e separate plot _plan. # OF BUILDINGS NOfv ON PARCEL -~z._-~------ USE OF BUILDINGS NOW ON PARCEL ~---+'----- f/o u f e ~J /J "-1-9& e;/ FRONT PROPERTY LINE STREET NAHE/ROAD NUMBER CHECK IF CORNER LOT DESCRIPTION OF :?RK/LANNED , _QPJ sbtt cc_ ¢.efqcAe(/ J'q Hf-) '}Z cJ:~ r~ e_ . I h-;Teby aC Owledge that I have read this application and the above is correct and I agree to comply with all county ordinances I and state _laws regulating building construction I SIGNATURE~ USE ONLY FLOOD HAZARD -----· CERTIFIED BLDG EU:VATION ----------~ SPECIAL CONDITIONS PROBLEMS V!ITH PERMIT ADDITIONAL INFORMATION NEEDED CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR OR ENGINEER PLANNING DEPARTMENT DATE \ \_, '· ''-l; Ct·:i~T IF I CAT J UH ~~·l'i"b-y--Cc 1· ti I:y lhil l th i 5 lmpr11v1• 1nPnl 1 n1 'Ro~er"t._ .....!> • ~.!i.!tl...~----1..S~---.R.::.n~_9_j._~l'::'.Ke-.. '?-_______ -..... _ improvement i:;urvey· plat, and thal it i:; not L(1 he• rel 1· or other __ i~provement lint!~ •• further certify lhat the improvemc~nts on A..._.., ... ..,,. lo. 1s,'{t... , except utility connection:; parcel, except as shown, t.hat there arc no cncro improvements on any adjoining prcmiscr;, exec pr_ .1~1 ind 1 of any easement, crossing or: bur:deninq any p.1r·t. o[ ~•.1 i, _._:;;~·--::,·~, '"/1..-;:.TINL"'I -.c..c...e:s..-:;> I \ c:;,:<,,,_,.JE,~ ) ~ OESCP,/PT/CN OF R,_ECOP,D_ ____'L::_~_-.._:llo~le Dated: .•. pa .. rce'.'l of land situated in th1' Si'.;ltSG,+ ~£..t-•01 il Towrship (, South, n_ge 9? West of the 6th P.M., Ga.-r1elci Cr.u1>t1 t.:alor,;do, more pa.rticularlj scribed as follows: ~~·:' ' ' ' \[ ·~:c~~·~en~1n9··,,~t an, iron post and bra~s cap properly marted and :1found_:~1n;jllace for the SE Corner of suid Section 13, the TRUE .f .. -.:_PQJNT: Of-·B[GlNNING; thence tforth li9'~57'l3" West along the south ~l:tne.':~_t said_ Section 13 1255,83 fo:<Et tll a point on the easterly ·.r:1.g~_t . .CJ .. f..~4Y of Divide Creek County P.oad; thence leaving said O.~\~ti;;Jif),~_:,'along said easterly right of way along a curve to 1~;.,r,tght, ·having a radius of 519.29 feet. and a central angle :fi'4.4~43•·20~'•.'"'.a distance of 133.43 feet (chord ~ears North .'.:::".·:·'.· ... ,'1 .. ;~.!~.,'t~.~ ... '.,.~West 133.07 feet); thence along said easterly right :/, .. :f~~y:.~·Horth 02°20'56" West 261.34 feet; thence along said >J;1,.,.; .. ;.i/'fle;1!1t~~J,r·;:rJ9ht of way. along a curve to thli left, having a ·:_.-::~:~:,'7~~ra.4~il'.s!'f.flflit},l3·~9l:· feet cind a central angle of 18c21'4D~, a -:~~:w~,, .. ,""<_dt.su,.ee of;·'31S.51 ~feet; thence along said easterly right of way _;,: .. ,;~~~~~t"~-Nr;ir-t;J:i,,;2,0~,S,o.~·3·5.~.:w~st 63.04 feet to a point on the west line of .-·' .. (<>.s~fd,Si5EJSE1; .thence lea'fing said easterly right of way North ,,·:'~-.~~'::,,OQ".08.~,05\:'E.,~ along s.aid we~t line 0.27 feet; thence ler.Ying :;,id ..,.Q!'-t'.'·l_lnt. :;o.uth r.':-0 :7~13" f,;~.t 17~9.(J tee.~ to a p~ir't or. the' P.,.:,:,.lirrc·of 5aid Sc<;tion 1~; ~lr('nte south illonc said east ___ l_in_e--~4.0~· .. ~("' feet to the TRU[ f'OJ:;T r;r firr,11rn11:r; - ;....\ :'.)l..)'S ~. ·_~;::: \ .:..:...._: -------·----- S-.~-~, o ''.:> // (:· lyir.9 1: fr·r:t C!I ritl1Lr si~r: fclh,,.:r.(' Corr::-:-,~r.~_i ~: ~.a.id ~r.u~h0,'St crrr·fr of llorth SJ' '(17" \.'est 12f:E·.73 f12r:t tu ii~" rii:bt of \o'o1Y of Divide Crr.t·I (.[lurity h, UEG11;r:l1:G; th(r,ce 5-::iuth Sf.' 18'16" lc:,:.t along a cur'Ve to t!w left, hav\r.9 a r~diu cf'nt1-c1 ~ng1e of 124"1€'~.c· a distanc.c-o !hr·Lh CJC'JS'l?" ~.'c~t 2S~.47 f!::c:t; u~";tr rir.h~, li~virq ~ radiLls c>f 16r..4~1 ft:1< ,,, 12'°51'2i'', <1.distanc£ of 3t:..r::1 let·: tot parcel dlscril:ed abO'.'€ end the termir vs C..o\ . ..)tJT PERMIT ·~~~~ OWNER '---'--i ,_/ ~f:~''-/_..·~'-'·i_' ~:..ic;'t:."'. ,_,_/,.c.' l_ LOCATIOH CONTRl\CTOR TllE FOLI,OWING ITEMS MJl.Y 111\VE BEEN OMIT'fEO FROM YOUR Pl.l\NS OR MJl.Y NOT COMPLY WITH 1'11E PROVISIONS OF 1'11E UNIFOHM BUILDING CODES. PLEllSE CllECK Al·L CIRCI,ED ITEMS BEFORE BEGINNING CONSTRIJCTIOll. ALL REFERENCES ARE 1900 EDITIONS OF TllE CODES. TllESE ITEMS AHE REQUIHEMEN'rS FOR H-3 OCCUPANCIES ONLY (ONE AND TWO FAMILY DWELI,INGS) AND AHE NOT ALL INCLUSIVE OF TllE CODE REQUIREMEN'fS, BUT ARE MEANT AS A GUIDE TO SOMR OF TIIE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE REQUillEMENTS. TllE APPROVED PLANS RETURNED TO YOU SllllLL BE KEPT AT TUE BUILDING SITE DURING CONSTHUCTION. FOR ANY REQUIREMENTS OF TllE NATIONAL ELECTRICAL CODE CONTACT TllE COLOllADO ELEC'rRICAL INSPECTOR. TllERE SllAI.L BE A FINllI, INSPEC"fION AND APPROVM, OF AJ,t, IJUILOINGS AND STRUCTURES NllEN COMPLETED AUD RE.ADY FOR OCCUPANCY AND USE -UBC SEC. 305 (d). / ' /}·:,,-,. ,• -·-:~· ..... '···.· '_ -· ---,-//:.' .· ,. ',· .' .• ··~-. ' J (. ! { /. 410_:,,." · ConCrete for foundations and 10ad bearing slabs ls required to be 3000 psi ____ _. in 28 days -UBC Chapter 26. Mortar and grout shall be in accordance with UDC Chapter 24 & Table 24-A and 24-D. 2. 3. 4. Maeonr.y units, mortar, and grout ehall be protected dnrlng cold weather in ac::c::ordanc::e with UDC Sec. 2404 (C). Conc::rnto ehal l be pr'otected during cold or hot weather in ac::c::ordance with UBC Sec. 2605 ( f) and ( g). Minimum concrete and/or masonry foundatl.on reinforcement requirements are shown on the attachment. (Note1 these minimums apply only if a foundation soils investigation ls not performed and the soils are assumed to have an expansion index of 20 or less and footing lands less than 2000 lbs/linear foot -UBC Sec. 2904 (a) and (b) and Sec. 2906. . Foundation frost protection ls 30" from finished grade to top of footing - UDC 2907 (a). ,j:.>' Foundations shall extend a min. of 6" above finished grade -UBC 2907 (d). ( &-.\ \ Provide for the control and drainage of surface water·away· .from the building -UBC 2907 (f), 7. 9. Foundation walls enclosing a basement below grade shall be .damp-proofed on the exterior with approved materials -UBC Sec. 1707 (d). Foundatlon plates or sille ehall be redwood or pressure treated wood (UBC - 2516 (c)), nnd shall be bolted to the foundation with not less than 1/2" dia bolts embedded at least 7" into concrete or masonry, spac.ed not more than 6 feet apar:-t 1 min. of 2 bolte per piece and within 12" of each· end of piece -UBC 2907 (f) .. Exterior concrete. or masonry piers shall extend O" min. above grade unless the posts or columns which they support are treated or decay resletant wood. Columns and posts located in basements shall be supported by concrete piers or metal pedestals. extending 6" min. above earth and 1" min. above floor unless treated or dec::ay resistant wood -UBC Sec::. 2516 (c::) 4. ·I 10 .)> Manufactured trusses, nnd manufactured joists and beams ( l. e. TJI/Micro- ____ .... Lams, BCI /Versa-I.ams, Glu-Lams, etc. ) , shall be sized and instal).ed ln accordance with the manufacturers requirements. 11. Wood joists or floor beams located closer than 18" or wood girders closet: than 12" to the ground in crawl spacee shall be treated or decay resistant wood -unc Sec::. 2516 (c::) 2. 12. Girders supported by masonry or concrete shall have 1/2" air space at top, sides, and ends ~nless treated or decay resistant wood -UBC Sec. 2516 (c) 5. Ends of beams· and girders shall have min. 3" of bearing on maeonry or concrete -UBC Sec. 2517 (c). . 13. Floor joists under and parallel to bearing partitions shall be doubled UBC 2517 (d) 5. 14. Floor joists require fttll depth solid blocking and must lap a rnln. of 3" over bearing supports -UBC 2517 (d) 3. 15. Beams, roof rafters, and celling and floor joists shall be supported laterally in accordance with unc 2506 (h). 16. Columns, posts, beams, and girders shall have positive connections provided to ensure against both uplift and lateral displacement -UBC Sec~ 2516 (m). 17. Ends of floor joists shall have 1 1/2" min. bearJng on wood or metal and no less than 3'' on concrete or masonry -UBC Sec. 2517 (c) and (d) 2. 10. Notches on the ends of floor joists -maK. 1/4 joist depth. Bored holes not within 2" of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located in middle 1/3 span -UBC Sec::. 2517 (d) 3. · 19. Floor joists and/or roof rafters are insufficient for the span -UBC Table 25-V-J-l and UBC Standards. r2o), Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UBC Sec. 2305 (d)-dead loads shall be as required in UBC Sec. 2305. 31. 32. 33. 3L 35. 36. 37. 38. 39. 10. 41. 42. 43. 44. Floor live load shall be 10 psf -UBC Sec.2304 (a) and Tab.le 23-A-1 -dead loads shall be ns reguired in UBC Sec. 2304. nasic wind speed shall be 90 mph -UBC Sec. 2311. lleadere over wall openings 4' wide or lese shall be doubled 2" . framing lumber On edge. Over 4' wide the header ehall be sized for the span -UBC Sec. 2517 (g) 5. Dearing walls supporting two floor lands are required to be a min. of 3" X 4"or 2"x 6" studs with a max. epacing of 16" on center-tmc Sec. 2517 (g) t. Wood etude mny be cut or notched to a depth not exceeding 25i of width in exterior walls and bearing partltlons and not exceeding 40% of width in non- bearlng partitions -UDC Sec. 2517 (g) 0. Wood stud!" moy have bored holes no qre11ter J.n dlnmeter than 40\ of stud width, 60li of width of doubled stnde (but not more than 2 e11ccesslve doubled etudB). No holes ehall be bored nearer than 5/0" to edge of htud -UBC Sec. 2517 (g) 9. Wnll bracing required both aldee of ench corner nnd every 25 llneal feet - the braced panel must be a min. of 4.9" in wldth perpendicular to studs -UBC Sec. 2517 (g) 3. · Approximate mi.n. lneulatlon vnluee are n-19 wr111e, R-25 roofs, and R-11 flooro over nnhentod spncn -aeo plnnn {or 11101·0 npocf flc roriulr.amontn - "Colorado F:nergy Conservatlon Stan<lards.11 Follm plastic insulation shall be separated from the building interior, including at.tics and crawl spaces, ln accordance with UBC Sec. 1712. Other insulation (including duct and plenum insulation and coverings per UMC Chapter 10) including facings shall meet the requlr.emente of UBC Sec. 1713. Masonry and etone veneer unite (5" max. ln thickness) ehall have min. size of No. 22 gauge by l" g;i.lv. metal ties or No. 9 gauge galv.' wire ties and spaced to support not more than 2 sq. ft. of wall area but not more than 24" on cente.r horizontally. When applied over etnd construction, the studa shall be max. of 16" on center. Approved building paper must be applied over the sheathing or studs -UDC Sec. 3006 (d). Celling height le requlred to be 7'6" in all rooms except kitchens., halls, bathrooms, arid storage areas which may be 1 '0" rnln. .:.. UBC Sec. 1207 (a) .------· Min. etalrwa·y-headroom clearance is 6'9" -UBC Sec. 3306 {p}. Min. stairwny width ls 36" -UBC Sec. 3306 (b) and min. landing dimension in the directlori of travel must aleo be 36" -UDC Sec. 3306 (g). Stalrwnys 1 ~Ju. run 9"; mnx. rise 0''; max. vnrlntlon in rise arid run 3/9" - UBC Sec. 3306 (c). Encloeed usable space under interior and exterlor etalrways shall be protected on .the enclosed side ae requlred for one-hour fire-ree.letlve conetruction UBC Sec. 3306 (m). Fire etops shall be provided in accordance with UBC Sec. 2516 (f) 2c. Stairway handrails: mln. height 34"J max. height 30"; handgrip portion shall be not less than 1 1/2" nor more than 2" in x-section dimension. Min. of one handrail requJ.red on all stairways with more than thi;ee risers. t?-Min. l 1/2" space required between wall and handrail -UBC Sec·. 3306 (j) . Guardrails of 36" min. height shall be installed at unenclosed floor openings anc' open sides of stairways, landings, ramps, decks or porches more than 30" above grade or floor below. Open guardrails shall have.a pattern au ch that a 'sphere 6" in dia. cannot pass through -UBC Sec. 1711. Under-floor (crawl space) croea ventilation ls required equal to l sq. ft. for each 150 sq. ft. of under-floor area -UBC Sec. 2516 (c) 6. Under-floor areas shall be provided with a min. lB" by 24" access opening - UDC Sec. 2516 (c) 2. 30" by 30" mln. if mechanical equip.: in under-floor area -UMC Sec. 709. J\ll sleeplng rooms below the fourth story without a door open,lng to the exterior shall have at least one operable window that meets the following requirements: HlNJMUH cleor opening: S. 7 sq, ft. MllKIMUM sill height1 44" MINIMUM net clear opening height1 24" (x31 1/4" ~ 5.7 sq.ft.) MINIMUM net clear opening wldtl11 20" (x~l" = 5.7 sq. ft.) Tl1ls also applies to basement sleeping rooms -UBC Sec. 1204. Glazing lo hnzardous locations as defined in UBC Sec. 5406 (glazing in doors and adJncent to doorways, and glazing in w.f.ndows located within 10 n vertically of a walking eurface) ehall be safety glazed or protected. Glass in sloped glazing (more than 15 from the vertical) and .ekylighte shall meet the requirements of UBC Chapter 34. Skylights and roof and wall panels of light-transmitting pla·etice shall meet the requirements of UBC Chapter 52. Provide combus tlon air for fuel burning equipment per UMC Chapter 6. Pressure rellef valves and/or comb_inatlon pressure/temperature relief valves shall be provided with a drain llne to a floor drain with min. 1" air gap • 45. 4 6. 4 7. 40. ~9. so. 51. 52. 53. 54. 55. 56. 57. 59. 59. 60. or extended to the exterlor of the building -UPC Sec. 1007. Domestic dlshwashlng machines shall not be directly connected to 8 drain. or waste disposer without the use of an approved alrgap -UPC Sec. 608 (d). Fuel burning appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed space opening into such room or epace* UPC Sec. 1309 and UMC Sec. 704 (unless listed for such use). Appliances {including space heating and water heating equipment) shall be accessible for repair and removal in accordance with the UMC. LPG fueled appliances shall not be installed in a pit, under-floor (crawl) space, or basement -UMC Sec. 504 (f). llppllances located ln a garage (or in an enclosure opening into a garage) shall be located out of the normal path of vehicles or protected from damage. Any portion of the appliance creatJ.ng a flnme, sphr.k or gloW shall be installed a min. of 10" above the garage floOr -UMC Sec. 509. Each water closet stool shall be located in a clear epace not leas than 30" in width and 24" in front of stool -UBC Sec. 511 (al. • Toilet rooms without operable windows shall be equ pped with an exhaust system ducted to the exterior -unc Sec. 1205 (c). Showers and 1.'ub/Shower enclosures eholl have o emooth, hnrc.J, nonabsorbent surface to a height of 70" min. above the drain inlet -.UBC Sec. 510 (b). Water-reSistent gypsum board shall not be used over vapor barriers, in saunas or steam rooms, or on ceilings -UBC Sec .. 4712. Attic access opening of not less than 22" by 30" le required -UBC Sec. 3205 (a). 30" by 30" if mechanical equip. in attic space -UMC Sec. 709. Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150 of the area-of the space ventilated. The area may be 1/JQO lf provided equally at lower and upper portions of the space with int~ .. J' vertical s.eparation of locations -UBC Sec. 3205 (c). Garage side of common wall between livlng space and garage shall be finished with materials appro-yed for one-hour fire-resistive construction. This also applies to ceilings and bearing walls if living space above the garage. Self closing min .. 1 3/B" solid, tight fittinr, door is requJ.red between house and r,rtrr1f;e IJBC 503 (cl) J, Electrically wired,· interconnected emoke detectors are required in all sleeping room access areas, near the top of stairways in upper levels, and near the bottom of stairways to basements -UBC Sec. 1210· .. (a). Wood stoves· and factory built chimneys, and manufactured fi:teplace unite and venting sys terns ,shall be installed in accordance with the manufacturers listing i;:-egulremente and inspected during installation UMC Chapter 9 and UBC Chapter 37. r Masonry and concrete f lreplaces and barbecues shall meet the requirements of UBC Chapters 23, 24, 26, 27 and 29. A chimney shall r\.ot support any structural load other than its own weight unless designed as a supporting member -unc Sec. 3703 (a).· • COPIES OF 1'JIE ITEM(S) CHECKED BELOW l\RE ATTl\CllED (Copies of any of the items above or below are·available upon request). Excavations, lills, foundations, and retaining walls -UBC Chapters 23 and 29. Retaining walls -UBC Sec. 2308 (b) and 2907 (g) 4. Roof coverings and drainage UBC Chapter 32 (Roof drains sized in accordance with UPC Appendix D). Roof sheathing~ UBC Sec. 2516 (i). Wood combined With (supporting) masonry or concrete -UBC Sec. 2515. Floor sheathing ·~ UBC Sec. 2516 (h). Wiring in plenums -UMC Chapter 10 and NEC. Fire and draft stops -UBC Sec. 2516 (f). Nailing requirements for connecting wood members -UBC Sec. 2516 (j) .. Enclosure of eleV.ator, vent, and dumbwaiter shafts, and clothes and rubbish chutes -UDC Sec. 1706. Exterior wall coverings and exterior weather protection -UBC Sec. 1707 (d) and 2516 (g). Interior application of gypsum wallboard and interior and exterior application of lath and plaster -UBC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. Landings and floor level at doors -UBC Sec. 3301 (i). Crose connection control and back flow prevention -UPC Sec. 1002 and 1003. Treated Wood Foundation Systems -UBC Standard 29-l. '~·· O~f~C!l_I~~QlLtl~ a·~ JtJG..v s;J; "WI.( 1 • .. 110, ~ ,'R14b.i_ ~ __ !f'_l,._,:i_'__F oi2t~_'L_____ .r.r-:-i < -, ' / --,~/-- 4-' -~--· --~;:--?-------./ -~-/-~ "'- · 1NSPECTION Will NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB Z4 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT\ ""''"""2~~:J~~~A~~;;~£0~~;~~~)s:s-~ y,i,/. 1; AC.RElMENT In consideration of the issuance of this pern1it, the applicant hereby agrees to corn ply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for "''hich this pern1it is granted, and further agrees th:-it if the ahovc said regulations are not fully co1nplied with in the zoning, location, erection and conslruction of the above described structure, the pe n1it 111ay 1hen be revoked by notice from th o~~uH ling 1spe rand IMMEDIA . _c,{'~~, NULL cl.ND VOID, Use ~i Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From tbc Street Until Final Inspection. INSPECTION RECORD Zoning lloof Coveriqg Elcclric-Final (by STATE ins >ector) Footing Foundation .; /·· ... / / ,-! / : l)lurnhing-U nderground Gas Piping Heating Ventilation Frame Plumbing-Rough Electric-Rough J-~r F\ff (by STA TE inspcclor) I 1· Insulation Drywall Fin~I ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Slreel, County Courthouse, Glenwood Springs, Colo. APPROV_ED DONOTDES .. TRO~TIIISCARD DatefP.o&;4 Bv'717 .&fhv/..)~ t;F PLACED OUTSIDE -COVER WITH CLEAR PLASTIC