Loading...
HomeMy WebLinkAbout04294GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Scilte 201 Glenwood Springs, Coloradof 81601 Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL�PERMIT PROPERTY ' l�?/ y1Cl OP -T (/(f Owner's Name erociwaV 0 System Locatior( J PE' ( msCS Present Addres Permit 4 a. Assessor's Parcel No. 5-2c` `39 -2-r V. n Legal Description of Assessor's Parcel No. 1%• 6 i4 SYSTEM DESIGN Septic Tank Capacity (gallon) Percolation Rate (minutes/inch) Required Absorption Area See Attached Special Setback Requirements: Date 6A -oo 5 This does not constitute a building or use permit. .� GC Phones )i'i - o Other Number of Bedrooms (or other) r-, -g -G6. dr Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface Absorption Area Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and State regulations/requirements Other Date Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs,alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained In the application of permit commits a Class I, Petty Offense ($500.00 fine —6 months in jail or both). White - APPLICANT Yellow - DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER 9Avv Nti• iteAbo ADDRESS 3 -fkV — CT CONTRACTOR 1 4-4? D ut L D cx-S PHONE .3``0`2$07 ADDRESS `a Z c7&.o Mtot,gwD D2. &a,wS, Co PHONE 27f—on`17 PERMIT REQUEST FOR ( NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town C o rin o.= 4` Size of Lot 2.7 AG Legal Description or Address %) 32s Los AJ0Lec Dr'. C,.,L. a I Q ce, 81'623 WASTES TYPE: `V), DWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER—DESCRIBE BUILDING OR SERVICE TYPE: 51 F Number of Bedrooms 3 Number of Persons Yom' Garbage Grinder W Automatic Washer Dishwasher SOURCE AND TYPE OF WATER SUPPLY: ,K) WELL ( ) SPRING If supplied by Community Water, give name of supplier: ( ) STREAM OR CREEK DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: ' 2 M t 7 Was an effort made to connect to the Community System? /JO, Exist -if -4 Soil arses A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table Percent Ground Slope 2 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: SEPTIC TANK ( ) AERATION PLANT ( ) VAULT VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE CHEMICAL TOILET( ) OTHER -DESCRIBE FINAL DISPOSAL BY: ABSORPTION TRENCH, BED OR PIT• ( ) EVAPOTRANSPIRATION UNDERGROUND DISPERSAL ( ) SAND FILTER ABOVE GROUND DISPERSAL ( ) WASTEWATER POND OTHER -DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? Ai PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. _ Name, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: II( (Bores Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and fumished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terns and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed UN 1 Date 2-A(0)PLEASE DRAW N ACCURATE MAP TO YOUR PROPERTY!! // 3 CIVIL ENGINEERING January 21, 2008 An Employee -Owned Company Andy Schwaller Garfield County Environmental Health 108 8th Street, Suite 201 Glenwood Springs, CO 81601 LAND SURVEYING r # /03428 Re: Treadway ISDS Design — Lot 3, Los Adobes, Garfield County, Colorado HCE Project No. 2061058.00 Dear Andy: This letter is to confirm the engineer's acceptance of the designed septic system of the Treadway residence located at Lot 3, Los Adobes. The design included a 1,500 gallon septic tank and 60 Quick 4 infiltrator units installed in a bed configuration. All of the inspection wells, infiltrators, manifolds, distribution box, and cleanouts were inspected by High Country Engineering, Inc. (HCE) and installed satisfactorily. The infiltrator configuration was changed to a bed configuration due to the existing site conditions, and is shown per the attached as -built drawing. An additional 10 infiltrator units were added to the 50 units required for the trench design for a total of 60 units. With the above -noted changed, the system has been completed with the intent of the original design. If you have any questions or need additional information, please contact us. Sincerely, HIGH COUNTRY ENGINEERING, INC. RoNeal, P.E. oject Manager RDN/tic/blf Enclosure 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 970.945.8676 phone 970.945.2555 fax www.hceng.com 14 Inverness Drive East, Suite F-120 Englewood, CO 80112 303.925.0544 phone 303.925.0547 fax PROPERTY BOUNDARY r - /COI —7000— i rJq •,'rn9,a•nN.�,!!1�111i.!.mf PROPOSED CLEANOUT MINIMUM 2% SLOPE PROPOSED CLEANOUTI _/O n PROPOSED 1,500 GALLON SEPTIC TANK WITH 81O—FILTER DRIvEW AY 00E) 5 BEREMO\IED) PROPOSED RESIDENCE _06 • 12 UNITS BUILDING ENVELOPE 16 UNITS TS 41— UTION BOX 12" REMOVABLE CAP' If4 — 1/2" VENT HOLES 4" 9) \ SOLID PIPE \ �\ / /i // \////i//i//i//i/i//i//i/// / SIDES ROUGHENED COUPLING CUT HOLE IN TOP OF INFILTRATOR UNIT FOR INSTALLATION OF INSPECTION WELL PIPE 0 4 0 PERFORATED PIPE 36" INSPECTION WELL DETAIL N, T, S. TAM ,IS 11 100' RADIUS FROM WELL REMOVABLE PVC CAP - INSTALL MARKER IF CAP IS TO BE BURIED FINISH GRADE 4" COUPLING 4" SEWER LINE TAI3E.E OF MINIMUM HORIZONTAL DISTANCES IN FEET BETWEEN COMPONENTS OF A SEWAGE DISPOSAL SYSTEM INSTALLED AFTER NOVEMBER 15, 1971 AND PERTINENT PHYSICAL FEATURES Dispersal System Mining Aerosol Methods Spring, Wells, Suction Lines (3) 100 Potable Witter Supply Linc (4)(2) 10 Potable Wnlcr Supply Cislcrn Dwelling Occupied Building Property Lincs p y , Piped or Lined Irrign(Ion Ditch 50 125 10 Subsoil Drains intermittent Irrigation Lateral 0 Sccpnna Pit or Slit Trench Absorption Trench, Seepnge Bcd, Sand Filler. Sub -surface Dispersnl System, or IAysvcll Unlined Sand Filter In Sail With n Percolation lints Slower Than 61) Minutes per Inch Unlined or Partially Lined Evnpalmnsplrnllnn System, Wastewater Pond, or SurIiwc Disposal System Other then Aerosol lined Sand Pester Lured IivnpotmnspInhllon held or Lined Wustewalar Pond '11 Privy or Vault Privy (3) 100 (3) 100 100 100 60 (4)(2) 50 ()(2) 25 (4)(2) 25 25 20 (4)(2) 25 25 25 25 25 20 15 15 15 60 0)(2) 10 25 15 50 Sepik 'funks, Trenanenl Plows, Dosing 'funks, Vaults (2) 50 (4)(2) la (4)(2) 10 25 15 25 10 10 ID 10 E 10 25 (I ) 5 10 Redding SCINCI n, NIIlucul blurs 121(41 ;n 14)12) In (4) 25 11 (2)(4) I0 10 I0 IA 10 10 10 10 10 (4) 10 Lake, Water Course, Irrigation Ditch or Stream (3) 25 (3) 511 (3) 50 25 25 25 25 25 50 (2)(4) 50 Dry Gulches (3) IO 4" RISER 4" 45' SWEEP BEND 1 FLOW, 1 $ 4"x4"x4" PVC WYE CLEAN OUT ASSEMBLY • 9 UNITS 8 UNITS 2H:1V SLOPE MAX EXISTING GROUND / %///j<I N FILtR#O••' 1001 MINIMUM// A SANDSJON \/\\ \%i�\ %\% 6" MIN SAND BELOW INFILTRATOR / ONSITE BACKFILL 12" MIN. COVER \/\ \moo j//j\/\\\i \ /\/\/\ \ •• \/\/\/,/ \• \ �■ aREA OF 1"5 1,U°46 TYPICAL CROSS SECTION SEWER CLEAN OUT DETAIL a=Quielpf"' Septic 'fuck 10 (3) 25 6 (3) 25 15 15 10 r, 10 10 10 5 10 10 N. T.S. INFILTRATOR 0 SYS IEMS INC Environmental Onalte Wastowaitor Selutlons"' G BI.lclnesc Pork Hood • F.C. IJox roll Old Saybrook, CT 016475 860-577-7000 • -577- FAX 001 A $60 7 800-221-4436 NM: The Department inn)/ require greater distances where warranted. For repair or upgrading of existing systems where We else of the lot prevents sleeting these distances, the repaired facility nary not be closer to water supply components than the existing facility. (1) Crossings from these 'U1010ces may be permitted if the drinking water or wastewater pipe is encased for at leant ten (10) feet on each side of the crossing or place where cohnhponents are closer than specified in the table. Pipe of Schedtile 40 rating or bunter mist be used, of sufficient diameter to easily slide over and completely encase the line. Ridged encl cups of at least Schedule 40 rating must be glued or;secured inn walertght fashion to the ends of the encasement pipe. There must be n hole of sufficient sire to accommodate the pipe in the lowermost section of the ridged cop no that the conveyance pipe rests on the bottom of the encasement pipe. The aren in which the pipe passes through the endcnps must Ili: sealed 1vi11h nn approved underground sealant compatible with this piping; used. (2) Add 8 feet additional distance for each' 1(11) gallons per day or design flow over' 10(1(1 gallons per day as specified in the table, unless it can be demonslrntcxl by an RPE or geologist that n mechanical or natural barrier wilt prevent contamination N.T,S, STANDARD CHAMBER Quick4 Standard Chamber 24" SECTION VIEW NiultlPort End Cap 12" 24" PrtONT VIEW T a• 1 r -s 52" 48" (EFFECTIVE LENGTH) 171 gtt SIDE VIEW 0" flhiiI!flLll/fi1111I\ ptd ct 910E VIEW Otlick4 Standard Chamber Nominal Specifications SIr.O(WxLx11) 34"x52"x 12'• Size (WxLxtl1 • Ei(ecIlvs Lanptlh48" Invert Height IIIVFlft Holu 11', 8" MultiPort End Cap Nominal Specifications 34'x16"x12" 8"or 1;25" LEGEND .- 5720 .._..-...-.. EXISTING BOUNDARY LINE EXISTING MAJOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED SWALE 3H:1V SLOPE OR FLATTER TO EXISTING GRADE • 10 0 5 GRAPHIC SCALE 10 20 40 ( IN FEET ) 1 inch = 10 ft, airOv* p00 /pF�, r er t b-340,15• AS OF: JANUARY 22, 2008 I_ J VICINITY MAP SCALE: 1"=2000' GENIEFONLJNOTER3 1, ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 4 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY 15: 600 GPD = AVERAGE DAILY FLOW. DESIGN FLOW = 1.5 * AVERAGE = 900 GPO (Q) SEPTIC TANK: MINIMUM TOTAL TANK SIZE: Q * 1 DAY/24 HRS * 30 HRS = 1125 GPO INSTALL ONE 1,500—GALLON TANK WITH BAFFLE ***INSTALL 810—FILTER IN SEPTIC TANK OUTLET*** STANDARD ABSORPTION AREA; A = Q Q=MAXIMUM FLOW �— t=PERCOLATION RATE = 30 min,/In. = 900Jb = 986 SF 5 USE OF QUICK 4 STANDARD CHAMBER INFILTRATOR UNITS IN TRENCH CONFIGURATION: 50% REDUCTION (986 SF * 0.50) 0 9.87 S.F./UNIT, 50 UNITS REQUIRED, RECOMMEND 2 ROW OF 19 UNITS AND 1 ROW OF 12 UNITS. 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS ANO AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER, 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY 8E VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING, 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE—HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. THIS SYSTEM IS BASED ON SOILS AND PERCOLATION INFORMATION PROVIDED BY HP GEOTECH, INC. JOB NO, 106 0739, DATED SEPTEMBER 20, 2006 INDICATING AN AVERAGE PERCOLATION RATE OF 30 MIN/IN. THE SOIL PROFILE CONSISTED OF APPROXIMATELY 4 FT OF SANDY GRAVEL OVERLYING SANDSTONE, 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY. 11, THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM ARCHITECT. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5,0 FEET, 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS, 15, THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY, HOME OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING TOILETS AND RUNNING WATER IS NOT ACCEPTABLE AND MAY OVERLOAD THE DESIGNED SYSTEM, 16. HIGH COUNTRY ENGINEERING RECOMMENDS CONCRETE SEPTIC TANKS OR XERXES FIBERGLASS EQUIVALENT. 17. IT IS ASSUMED NO WELLS ARE LOCATED WITHIN A 100' RADIUS. AREA DF INFLUENCE Pmt srAIFS1DEUNS4 PROPOSED FIELD' (PROPOSED HOUSE). TOTAL AVERAGE DAILY FLOW = 600 GPD AREA OF INFLUENCE DESIGN FLOW 600 GPO * 1.5 = 900 GPD FOR FIRST 1,000 GPD: 100 FEET ADD 8 ADDITIONAL FEET FOR EACH 100 GALLONS PER DAY OF AREA OF INFLUENCE FLOW OVER 1,000 GALLONS 0 FEET + 100 FEET = 100 FEET (AREA OF INFLUENCE). 43ENERAL ABSORPTION TRENCH NOTES 1, ABSORPTION LATERALS SHALL NOT EXCEED 100—FEET IN LENGTH, 2. THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. 3, DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA, 4. TRENCH LATERALS SHALL FOLLOW CONTOURS, 5. INSTALL INFILTRATOR IN ACCORDANCE W)Thl MANUFACTURER'S RECOMMENDATIONS, 6. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION, 7, NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF' RUBBER TIRE VEHICLES OVER ABSORPTION AREA 15 PROHIBITED 8, BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT—RUN MATERIAL, 9, IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIO—MAT. 10. BEND IN TRENCH SHALL BE MADE WITH END PLATES AND 4"0 PVC OR MANUFACTURER'S PREFABRICATED BENDS, OR WITHIN THE LIMITS OF THE QUICK 4 CHAMBER,