Loading...
HomeMy WebLinkAbout04211rC 16:5- Com- 5131 -I GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 201 Glenwood Springs, Coloradof 81601 Phone (9T9) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY Owner's Name 11ienaR-J; 1 l Present Address 5ntjA % System Location l C K 3 I QI, 1 I '_- Permit 4211 Asesssor's Parcel No. This does not constitute a building or use permit. PhoneLfO 5 - 5-fi`)"-' Legal Description of Assessor's Parcel No. SYSTEM DESIGN Septic Tank Capacity (gallon) - Other /� / �/7` L( Percolation Rate (minutes/inch) Number o1 Bedro ms (or other' '���w�" / t'��i Required Absorption Area - See Attached /Z5 d 1.'_ /3 (juzle / Special Setback Requirements: /`c A 1,(4� `7� Date U /16 6. Inspector ,C4A01 FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity ,= (:) ( 0 14 Septic Tank Manufacturer or Trade Name ( A>'day•c. 10 Sep{Ic Tank Access within 8" of surface ly Absorption Area LL "t' i I. L0 A Absorption Area Type and/or Manufacturer or Trade Name 4:4" 2., , ,e L it, ( I . I Adequate compliance with County and State regulations/requirements (+ "et Other ri CL%l,t.k44o v )7v- --1J, „, Aru�O�� L36,4,, ��iL,� ..(7. 1. ,,,,,ii,f s---0,-.), 1/44- i.„1,.,1/1 ke. K!r %�.• 4-f Date U �-�- l,' Inspector j'� �,4 ri C! ,t ,) be RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or e requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I. Petty Offense ($500.00 fine — 6 months in jail or both). ,,.a whits- APPI rem- vdw, nroeoruc rr 12✓ n OWNER FLA M Q Pato LL.0 ADDRESS I G 3 II 0 2 a 1 G Zf/( 81I ),PHONE 976 -607 ►-0729‘ CONTRACTOR toL,n'a,, cf f`-, ADDRESS /7.`t/< et) PHONE INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION PERMIT REQUEST FOR 0/KNEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town Size of Lot Legal Description or Address / 7 q 3 EC 21 C .(11c Cd o I c s a WASTES TYPE: ( ) DWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES (',)'OTHER -DESCRIBE Al Qw, BUILDING OR SERVICE TYPE: j <t rd S/i ra y c Number of Bedrooms O Number of Persons C7 ( ) Garbage Grinder ( ) Automatic Washer ( ) Dishwasher SOURCE AND TYPE OF WATER SUPPLY: ( ) WELL (bQ SPRING ( ) STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: Was an effort made to connect to the Community System? A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table Percent Ground Slope 2 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (,1( SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER -DESCRIBE FINAL DISPOSAL BY: (V( ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER -DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? Jte> PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Name, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed U Lk k Date 8- /6 -0‘ PLEASE DRAW AN AC RATE MAP TO YOUR PROPERTY!! 3 Iv" Designate North Arrow al z N = ) O a0 O V c...17 4) O T CC C C cd Q 3• 713 0 V)• "0 tU a U CCO y O U td Q u y Q) � 'w 12 ▪ oo•E = o 3 •3 T et a C m y C m o Toza - UU'A U U • 2" - 1'N a) v y�� o ‘T li - o r- =d MO N 3t o s o 0 • 0 U 4.. O '-' ✓ J County Road (Note the Road Number and Name) A 4 aZt This Private Residential Treatment System is designed to serve a Three bedroom Single Family Home.. According to Garfield County regulations for design average waste flow assume 2 persons per bedroom and an average daily sewage flow of 75 gpd/person.. Therefore: Residential Sewage Flow: (3 Bedrooms) x 2 people/ bedroom = 6 persons 6 persons X 75 gpd/ person = 450 gpd Average Daily Waste Flow = 450 gpd Design Daily Waste Flow = 1.50 x Average Daily Waste Flow; 1.50 x 450 gpd = 675 gpd Minimum recommended concrete septic tank size = 1000 gallons Percolation testing was performed by Schmueser Gordon Meyer, Inc. Results of percolation testing was as follows: Percolation Rate 1: 32 min / in Percolation Rate 2: 17.5 min / in Percolation Rate 3: 17.5 min / in Use a Percolation Rate = 23 min / in The required absorption area (A) for a normal gravel type leach area is calculated using the following formula: A = Design flow x VAve. Percolation Rate 5 Therefore, A = 675 x 23 5 A = 647 sf Garfield County allows a maximum reduction of 50% of the required leaching area for a graveless type design in a Trench configuration and maximum 30% reduction for a Bed configuration. This is a Trench configuration, Therefore the required Area = 647 sf x 0.5 = 323 sf Required number of Standard Infiltrator Units = 323 / 15.5 = 21 units Required Number of Infiltrator Quick4 units = 21 x 1.5625 = 33 The leach Trenches shall be 3 rows, 11 units long for a total of 33 units. Minimum Horizontal Setbacks: Setback from Wells: 100 ft Setback from River. 50 ft Setback from Dry Gulch: 25 ft The above designed ISDS shall be installed satisfying all minimum setbacks and design standards as described by Garfield County Planning Dept. ISDS regulations and according to all manufacturers specifications and recommendations. Residence is Served by private water system. Existing Conditions and Boundary survey provided by High County Engineering, Glenwood Springs, Colorado. 4" PVC inspection Port 4" Notch to be Cut Into Bottom of Pipe. (Locutions as per Site Plan) ===11==1==== = _=_ AATFORM 0 OPS AIR PUMP 30" ADS PIPE RISER WITH COVER INTERNAL AIR SUPPLY 4" PVC SAMPLE PORT w/ REMOVABLE END CAP INSTALL IN IRRIGATION VALVE SOX. SITE PLAN & TSDS DETAILS 4" SDR 35 Sewer Pipe To Distribution Box (min. Slope = 2%) 4PIC NIPPLE W/ END CAP HYDRO -ACTION INDUSTRIES AP -500 AEROBIC TREATEMENT UNIT Job No. Drown by: cws Dote: 8/30/05 QC: PE.: RWP File: ISDS OF 1 ') Elbow (Typ.) 7" MH Sections w/ Cover. :Ilion Box se Course d Proctor. Stub Pipe 12" Into Infiltrator Unit 4" SDR 35 Sewer Pipe Equo/izer at Feeder Pipe. To Remaining Trenches O 6' min.. Distribution Box Plumbing Detail SCALE: AIT.S. 2 infiltrator Ouick4 Standard Units all be 3 Trenches x 11 Units Long for a Total of 33 Units Finish Ground Stub 4" SDR .35 Sewer Pipe 12" into Infiltrator Unit. i (SeeBackfill /n with Excavated Soils (See Infiltrator installation instructio, SW MN - INS Ilan iial'i3: •aEa V\ i'\`i\ i\\�/\ \/\\i\ /\ \/\S\\/\\/\\i\\\ii\ \i/, Scarify Excavated Leaching Surface (Keep Heavy \o,, Equipment Out of Excavated Area). Entire Leaching Bed Surface to be Leve/ Within 0.1 feet. Doub/e Clean—Out w/ Removable Cops 8" min. — Typical Side Section Detail I- Finish Grade Conc. Cover (Typ) 2016 Riser Sections (Typ) 1 Sewer Pipe ape = 2%) 6 Bedding at Bose to tor Density 4.00' ;at M0t suoUc.75UcCioCDi-U,`_�.»oUc�� Septic Tank and Treatment System Detail SCALE: N.T.S. rd ton BER REVISION DATE BY I5 6 )N JTAL) _A77oN TFST »' LOCATIONS (Typ.f 1 GRAPHIC SCALE IN FEET 1 NCH - Jo FEEr 4" —S Standard 4 8 Hole Conc. Dista; w/ Baffle. Bed on 6" Cl. 6 Br Compact Base to 95% Mooing 4" SDR 35 Sewer Pipe From Septic Tank (2% min. Slope) Install Polylc /nlet of £ac J Site Plan x:,._30' N 4" SDR 35 (min. Sl 6" C/ Comp( 95% Modified Prop JESER GORDON MEYER •th Street, Suite 200 Springs, Colorado 81601 ,5-1004 FAX (970) 945-5948 :olorado 970 925-6727 Butte, CO(9 0) 349-5355 sar®sgm-inc.com Ron & Carol 131 Na tl ve Springs Su b di v; I APPROX. LOCATION OF RESIDENCE 1000 gat SEPTIC TANK APS 500 TREATMENT SYSTEM INFILTRATOR Ouick4 STANDARD CHAMBERS 4" P✓C INSPEt PORT (Typ.)(6 -- —5385— — — -- PER APPS PRELIMINARY NOT FOR CONSTRUCTION 83'00' min. SETBACK FROM PROPERTY LINES) SCHI\ 118 W Glenw( (970) 9 � n, SCHMUESER I GORDON 1 MEYER CrAsepsetedt ENGINEERS a SURVEYORS E-mail:eng I GRAVEL DRIVEWP GRAVEL ROAD \ 4" -SDR 35 SEWER PIPE 48" MANHOLE Si( w/ i Standard Infiltrator Trenches Shall be 1 Unit Wide x 6 Units Long in 4 Trenches for o Total of 24 Units Stub 4" SDR 35 Sewer Pipe 12" into Infiltrator Unit. ■5t fl IaI--ISI--I-I--1-1--1 == I--1 I--1 Typical Inf SCALE: N.T.S. GRAPHIC.` SCALE 10 A 20' 1 inch Cont.. "Interval = 2' it. i n I ro NELL / / i _ 24 STANDARD INFILIIRATOR UNITS 4" — SDR 35 SEWER PIPE 1000 GAL. ONCRETE / SEPTIC TANK / 8 Hole Conc. Oistribub w/ Baffle. Bed on 6" Cl. 6 Base Compact Base to 95Z Modified 1 Standard 48" MH Se( w/ C r- PERCOLATION TEST PIT LOCATIONS AS SHOWN Plan 20' Finish Ground s • ' D e eD De BackfII with Excovafed Soilse (See Infiltrator installation instructions) e > e 1 > s • D 1- ='I -- -- I--I-I--1�1=! ----I.I--LI--I.I--I■1==�1--I.I--I.ISI--ISI--I ==r===== it==i==i==i==iz mi= =i==I= =i==4= =I==5=i==i==i= =i==iE==al==i_ P 6 • 4 D D D 1. Dis ri inlet invert at least 1 i outlet invert. The outlet inches above the floor o 2. Septic Tank: a.) The distance from underside of the tank tc inches. b.) Liquid depth shall the max. depth shall no 60 inches, which ever is c.) The volume of the hold no less than 1/2 c capacity. d.) The transfer of Tic compartment to the se( liquid depth of at least invert but not in the sl 3. Roof drains, foundati cistern overflows shall n any part of the disposa 4. Bends in the building 45' ells or long sweep 5. Sch. 40 PVC is requ sewer is located under 6. No enclosed structur the septic tank. 7. The final cover over graded to deflect run—c disposal area. 4" PVC Inspection Install in Irrigation 4" Notch to be Cc (Locations as per Cover ` lax. / /\ /\ i\ /\ /A\/AA/A /A /\ /\ iA /A racy Excavated Leaching Surface (Keep Heavy 'pment Out of Excavated Area). Entire Leaching Surface to be Leve/ Within 0.1 feet. Itor® Side Section Detail i /)\ //// i THIS DRAWING NOT VALID UNLESS LATE NO. DESCRIPTION n A A _u-■ 11111 11 Il I III II 301St m a+ a01 m ' a a m cm m300Ni ai§ m N 3009 .cu m 03 N a 0 N�y5= pO 0 c 0))0 A kala O y O0 a mmi0) O < 0 .'o m ay <• g 0 m f. 3 £S'p 0 ' 1 t0 a m at m a.cea 0 m N 0 m )O =m 3 5 p3 x� N' Co y m y, a aric y' - - a ca v m m 08ECLC Nq _ c a C m iiN aON 0 0 G m m m < -i 0 cny o a 0 N C _.m 0 ?. 0 C y o • 7 C 0 m 3 comma 5@aa 0 Existing Conditions and Boundary survey provided by Bookcllff Surveying Services, Inc m N m 8 crv m d 1 y s 3 m 00< Or N 0ca ma CT a 3 N 0 0 007 a • N N cn r/ar/�� m c cn `Z'. (0/1 C0 3 m a3 0 a. 8_c a3 0 N co m O a- 2-.)1 m 3cu C 0. a.C CD y. m0 a g1 m 0 O a = a N O N 0/ 0. m y 0 0. 0. 0 0. 0 CD m CO 00)) 0 m X00 3 3 3 m 0 7 ql c 0 cn 't o =moo 3� 7 o .m c 3 a 0 0 o m a� m ,n 7 03N to O 0 A 0 0 Required number of Infiltrator Units = 369.7 / 15.5 = 24 units Therefore the required Area = 739.4 sf x 0.5 = 369.7 sf a 0 m 31 N 0 N a cc "7 0 7 0 m 7 O a co cc c 20 7 • 01 0 ay N. m 3 m fix, Oc 8a c o 0 C = o 0 0 0 m .o C_ o. N z m N m O m 0 2 m co y 1s 4'6EL = V cn c v a N C. co m a a O o x O m D m O 03 to 3 N 0 m m 2 c o) a co. co m 0 0 t0 O c m elea uoilelooJed .an 0 m m ccoo 0 gg§ o 1 3 a m m c 3 > > > > j 3 873 73 d m m m w 3 o m m m a 3 W N + 10 m y O) N 0 W 0) 0. 0) y a 3 3 3 . 1 w \ \ \ I 0 0 0 m N 7 .c � 0 d 0 x N co tl 0 0 0 m 0 pd69L9=Pd6094x09'1, Design Daily Waste Flow = 1.50 x Average Daily Waste Flow; Average Daily Waste Flow = 450 gpd uosied /pd6 YL 01 01 co 0. (3 Bedrooms) x 2 people/ bedroom = 6 persons �D �g0 as af0 O O 3 C) m 3 0. 0 0 CD O 3 m 0 V m N C 3 m m O N 0 O' a 00 3 m a m m m to m a m cam d CO 0 F 1 The Proposed residence is a Three bedroom Single Family Residence. v m 0ddV 1N3110 03AOLlddV 0 2 m n x m v Av CD 0 n N T 3 0 A 0i 0 0 0 0 5 v a x --4) 0 o co CO 03 c:3-`1 -(71 Ox NNOD W `_J co cor • E 1(( -I c°a Coo ID 1 ca �cnr m04 onm a� 0 � zoc 20 .1 m0 $Z N CD 23 0 3111.E 133HS AO 1 'ON I3HHS to 0 v Concrete Septic Tank Detail s 1114 .41 0.1 • lis its 4(1 !:7 i g!i Ofii bei br, bee 111 bee 117 1/4 1/4 ire 4114 1/4 �ci ?—Emn�mW9o��° �° 0 °o °moo ° 3 v °7 �� 73,l„y fa If CA=3 .0° a7 P- Ny(rt 0 N 3 • 3 ,, «S ° f�a a S° Cr Q J V J A "'. -I O .r C a y 7 ' N n m 0 CO e(4 0 4. O Q—O ,nt CO La 0 O O a r. 7 T o - O La R N 'O ° f°-, N 3 Q p N i '0 0 a y o -,..-.- 3— 0 c 3 n o zcao — r_. co co u& i • al C. 0seOS ° °°0 — 0. rta • '�0 • y —° Tre. 0 O O N S O) w 7 O S N °+ JO 0 ° �-, -, ° -,a 2010 Riser Sections (ryp) A ,e a 1 1 c 0 T W 30 3 0 0 0). 4 \&/lLfl lit,f-r Tie '70 2C' +7.51W. 8Cv1G w o.0{f3, Assamect Jev, oo.os _ rB ti3treek Ci IGo X84 °12 w • - vv-ciica-Ees f ouxct re.ccar a cap rnaurka L.S. 141 11 a 1r e`( rsbs Scope: Conkotaw Th1-arvak 2� A. CALCULATIONS 1. PERCOLATION RATE = 20 MPI AVG. (Timberline Engineering) 2. DESIGN FLOW = 3 BEDROOMS X 2 X 75 X 1.5 = 675 GALLONS PER DAY 3. REQUIRED SEPTIC TANK CAPACITY = 675 X 1.25 = 844 GALLONS USE 1— 1,000 GAL, TWO COMPARTMENT SEPTIC TANKS 4. ABSORPTION BED AREA REQUIRED = A = ( 675 / 5 ) • 20"1/2 = 603 SF 5. BIODIFFUSER BED INSTALLATION: 603 SO. FT./ 15.5 SQ.FT. PER UNIT = 39 UNITS MIN. USE 6 UNIT MOE X 7 UNIT BIODIFFUSER ARRAY OF H-10 UNITS 6. WELL SETBACK DISTANCE 100 FT — NO WELLS ON PROPERTY — CITY WATER 7. DITCH AND POND SETBACK DISTANCES 50 FT 8. WATER LINE SETBACK DISTANCE 10 FT. TO TANK, 25 FT. TO FIELD 3. (NERAL NOTES ( / BED SHALL BE E 1 ONENATURA� RAVELS (NOT IN RLL)�AND+BACK FILLED MTH NATURAL SOILS PROVIDE POSITIVE DRAINAGE AWAY FROM THE BED. 2. THE SEPTIC TANKS SHALL BE LOCATED AT LEAST FIVE FEET AWAY FROM THE RESIDENCE 3. THE PIPE FROM THE RESIDENCE TO THE TANK MUST BE INSTALLED AS FOLLOWS: THE PIPE MUST BE INSTALLED STRAIGHT IN ALIGNMENT AND GRADE. IF A CHANGE IN ALIGNMENT OR GRADE IS NECESSARY, A CLEANOUT WILL BE REQUIRED AT THE CHANGE. THE MINIMUM GRADE OF THE PIPE MUST BE 1/4" PER FOOT. THE PIPE MUST BE A MINIMUM OF ASTM 3034 PVC PIPE. IF THE LINE CROSSES A VEHICULAR ACCESS, THE PIPE SPECIFICATION SHALL BE ASTM 3034 PVC OR BETTER. A MINIMUM OF 1 CLEANOUT SHALL BE INSTALLED AT THE LOCATION WHERE THE PIPE LEAVES THE RESIDENCE THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 4. THE PIPE FROM THE SEPTIC TANK TO THE BIODIFFUSER BED SYSTEM MUST BE INSTALLED AS FOLLOWS: THE MINIMUM SLOPE OF THE LINE MUST BE 1/4" PER FOOT. THE PIPE SHALL BE A MINIMUM OF ASTM 3034 PVC PIPE. IF THE LINE CROSSES A VEHICULAR ACCESS, THE PIPE SPECIFICATION SHALL BE CHANGED TO ASTM 3034 PVC OR BETTER. THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 5. USE RISERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE. 6. ALL MATERIALS, INSTALLATION PRACTICES AND SETBACK REQUIREMENTS SHALL COMPLY WITH PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS 7. INFILTRATOR COMPONENTS TO BE INSTALLED IN ACCORDANCE MTH MANUFACTURERS RECOMMENDATIONS. 8. SEAL ALL PIPES ENTERING DISTRIBUTION BOX MTH WATERPROOF MATERIAL 9. INSTALL INSPECTION PORTS AT ALL 4 CORNERS OF INFILTRATOR BED RECEIVED ILII_ 2 8 2006 GARFIEL0 COUNTY BUILDING Li PLANNINn B� uatotar4.,� E Totroy0.r kiLc. 5u YV EM4 �j J e- otoo . G(ei&wooci. Ave ccurbo kaale, Go(oty-cjo LINES /N SPACE SYDNEY L I NC/COME (L. S. /4/1/) "Rev; Sec 23 3"Larck a.00S Rev i.seoQ- 1( "1`{aA 4 qq 4 BOX 121 CARBONDALt4COLORADO 81623 303-963-3852 DATE: 30 >Card&isgc: SCALE: I"= 20� , .._..._,...__.,_