INDIVIDUAL SEWAGE DISPOSAL PERMIT
PROPERTY
Owner's Name
System Location
Legal Description of Assessor's Parcel No
(1 -'Present Address 1, .� i•' j 7 IL i /
J
.1
Permit
A. 1 to 0
Assessor's Parcel No.
This does not constitute
a building or use permit.
-163- '7_3357
Phone 7'7 — I / (7,9
SYSTEM DESIGN
Septic Tank Capacity (gallon) Other
Percolation Rate (minutes/inch) Number of Bedrooms (or other)
Required Absorption Area - See Attached
Special Setback Requirements:
Date Inspector
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System Installer
Septic Tank Capacity
Septic Tank Manufacturer or Trade Name
Septic Tank Access within 8" of surface
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name
Adequate compliance with County and State regulations/requirements
Other
Date Inspector
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE
1
v' `\r
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6
months in jail or both).
White - APPLICANT Yellow - DEPARTMENT
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
OWNER JO C f Ue'a% hr►�
ADDRESS Par) -0 /PIMP 8a--- PHONE q40 8 S3
CONTRACTOR (' l i ��) •
ADDRESS / 7-0 3 ?Z4,/t
PHONE / T a,
PERMIT REQUEST FOR ( ) NEW INSTALLATION ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable
building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILITY:
Near what City of Town C Q��l�}') ��x /�'P-J Size of Lot `1,3 a -J
Legal Description or Address I -7-a-e 3 mw) &)- (2/J7t'T)'i(1(L /- Co Sl&ic3
WASTES TYPE: DWELLING ( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES
( ) OTHER -DESCRIBE
BUILDING OR SERVICE TYPE: regidXii' 1 u_.
Number of Bedrooms 3 Number of Persons (Vvi (,�
( ) Garbage Grinder ( ) Automatic Washer KDishwasher -11/10
SOURCE AND TYPE OF WATER SUPPLY: /6 WELL ( ) SPRING ( ) STREAM OR CREEK
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System?
A site plan is required to be submitted that indicates the following MINIMUM distances:
Leach Field to Well: 100 feet
Septic Tank to Well: 50 feet
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System (septic tank & disposal field) to Property Lines: 10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT
A SITE PLAN.
GROUND CONDITIONS:
De th to first Ground Water Table
p
Sej-- 'nfv�
Percent Ground Slope
l
2
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
SEPTIC TANK
VAULT PRIVY
PIT PRIVY
CHEMICAL TOILET( )
( ) AERATION PLANT
( ) COMPOSTING TOILET
( ) INCINERATION TOILET
OTHER -DESCRIBE
FINAL DISPOSAL BY:
(4) ABSORPTION TRENCH, BED OR PIT
( ) UNDERGROUND DISPERSAL
( ) ABOVE GROUND DISPERSAL
( ) OTHER -DESCRIBE
VAULT
RECYCLING, POTABLE USE
RECYCLING, OTHER USE
( ) EVAPOTRANSPIRATION
( ) SAND FILTER
( ) WASTEWATER POND
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE?
PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the
Percolation Test)
Minutes
Minutes
per inch in hole No. 1
per inch in hole No. 2
Minutes per inch in hole No. 3
Minutes per inch in hole No.
Name, address and telephone of RPE who made soil absorption tests:
Name, address and telephone of RPE responsible for design of the system:
(7t\--CMI,vo_
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the applicant
or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is
subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made,
information and reports submitted herewith and required to be submitted by the applicant are or will be represented to
be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of
health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any
falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based
upon said application and in legal action for perjury as provided by law.
Signed J Date r / 4(4
PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!!
3
April 23, 2008
Julie Taylor
Garfield County Building Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Dylan Balderson
17283 Highway 82
Carbondale, CO 81623
RE: As -Built On-site Wastewater System (OWS), Balderson Residence— 17283 Highway 82, Garfield
County, Colorado, Replacement Upgrade,
SE Job No. 25266.01 Garfield County Permit Number 4170
Dear Gentleman:
Pursuant to County Regulations, this letter provides documentation that the new Onsite Wastewater System (OWS)
recently installed is in general compliance with the permitted design. Sopris Engineering has performed site visits
to measure, inspect, and document the as built conditions of the constructed system. The as -built conditions and
installation of the new OWS components is in compliance with the permitted design specifications for the system.
The as -built size and performance specifications of the new OWS system are in compliance with the specifications
on the design drawing.
The System was installed in accordance with State and County Regulations; the design presented in the Sopris
Engineering report and the design drawing specifications and details, dated November 17, 2005. The system is
designed and installed to serve the maximum 3 bedroom home. The septic tank was installed on the north side of the
house in a landscaped area approximately 20' from the north wall of the house. The 1000 -gallon dual compartment
concrete septic tank was installed with an effluent filter installed in the outlet tee and risers with lids to the surface.
Two new gravity lines from the house to the tank were installed. Cleanouts were installed adjacent to the exterior
walls of the house.
The absorption field was constructed with 2 trenches containing 12 Elgen In -Drain units in each trench. A
distribution box was installed next to the field to equally distribute effluent to the trenches via individual 4"
distribution lines connected at the head of each trench. Inspection ports were installed at each terminal end of the
perforated distribution pipes. The individual trenches were installed level with 6" of concrete sand overlying
suitable native soils below the In -Drain units. Four -inch perforated distribution pipes run along the top center of the
Inn -drain units in each trench. The In -drain units are installed per manufacturer's requirements. The top and
sidewalls of the treatment units, sand layer and distribution pipe is installed in a filter fabric envelope. The trenches
are backfilled over the In -Drain units to a slightly mounded finish grade approximately 18"-24" above the
distribution pipe. The construction was completed utilizing specified materials installed a
iUWEThe
constructed field is being revegetated. j((��D
OWS Operation and Maintenance
APR 2 5 2008
GAKFiELD COUNTY
502 Main Street • Suite A3 n Carbondale, CO 81623 ❑ (970) 704-0311 PIJK”0181-)A41611N0313
SOPRIS ENCINEERINC • LLC
civil consultants
Julie Taylor and Dylan Balderson
SE Job No. 25266.01
April 23, 2008
Page 2
All components of the engineered OWS shall be inspected on a regular basis and be properly maintained.
The re establishment of vegetative cover over the field and responsibility for operation, inspection and
maintenance of the system will remain with the Lot Owner or the owners representative. The owner shall
periodically inspect the OWS and perform all maintenance and repairs as necessary to ensure that the
system is in good operating condition and performing as designed.
The OWS should require minimal maintenance, Several factors influencing the need for maintenance
include: actual wastewater flows versus design flows, the volume of kitchen/domestic waste (excluding
human waste and toilet paper), excessive household chemicals and other toxic liquids. The tank, sanitary
tees and effluent filter should be visually inspected bi-annually for clogging debris, damage, leaks, or other
potential problems. In general, for a properly utilized system, septic tanks should be pumped and inspected
every 2 - 4 years. The effluent filter should be cleaned every six months and at the time of pumping.
Absorption fields should be maintained with suitable vegetative cover and kept free of root invasive plants.
Positive surface drainage away from the absorption field should be maintained.
If you have any questions or need any additional information, please call.
Sincerely,
SOPRIS ENGINEERING, LLC
Paul E. Rutledge
Design.E' ineer
Valley Nichol, PE
Principal
10
5
GRAPHIC SCALE
10
20
( IN FEET )
1 inch = 10 ft.
40
4"DIA. PERFORATED DISTRIBUTION LATERAL PIPE
INSTALLED AT THE TOP CENTER OF THE 1N -DRAIN
UNITS RUN IHE FULL LENGTH OF THE TRENCHES.
ORIENT PERFORATIONS DOWNWARD AT 5 AND 7
O'CLOCK. CAP END WITH SOUD 4- SWEEP
90F17-11NG AND EXTEND A 4" INSPECTION PORT
RISER WITH CAP AT THE SURFACE ON ENDS OF
THE DISTRIBUTION PIPE IN EACH TRENCH.
4" DISTRIBUlION UNES
50.0'
04 -RA,/
DISTRIBUTION BOX W/
BUILT IN BAFFLE
& PIPE RISER TO SURFACE
" EFFLUENT UNE TO 0 -BOX
USE SDR -35 PIPE
EXISTING DRIVEWAY
INSPECTION PORT (TYP.)1
ABSORPTION/TREATMENT BED
USE 24 ELJEN IN DRAIN UNITS IIN 2 TRENCHES
WITH 12 UNITS PER TRENCH. TIHE IN -DRAIN
UNITS SHALL BE INSTALLED AT LEVEL GRADE
OVER 6" OF SELECT FILTER SAND IN A 150 SQ.
FT. TRENCH EXCAVATION (TYP.). THE SYSTEM
SHALL BE PLUMBED FOR EQUAL DIS1RIBU11ON.
INSTALL 1000 GAL TWO COMPARMENT C.ONCREIE
SEPTIC TANK. INSTALL EFFLUENT FILTER IN
OUTLET SANITARY TEE. INSTALL MINIUMUM 24"
DIAMETER RISERS OVER SEPTIC TANK ACCESS
OPENINGS FOR ACCESS TO TANK CHAMBERS. ALL
RISERS TO HAVE UDS AT THE SURFACE. TANK
CONNECTIONS AND RISER TO BE WATERTIGHT.
LAYOUT OF BED AND SOIL COND1111ONS TO BE
APPROVED BY THE ENGINEER PRIIOR TO
INSTALLATION OF COMPONENTS. MODIFICA71ONS
TO THE DESIGN OF SYSTEM WILL. BE DEPENDANT
ON ADDITIONAL GEO-TECHNICAL EVALUATIONS
AND ASSESMENT.
EXISTING LAWN
4" SEWAGE UNE
FROM HOUSE
0 2% SLOPE
11110 -WAY
CLEANOUT
OWS SYSTEM NOTES
1. ADD A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE.
2. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO COUNTY AND
THE STATE OF COLORADO INDIVIDUAL SEWAGE DISPOSAL SYSTEM (SDS)
REGULATIONS.
3. ALL SEWER LINES TO BE SDR -35 OF SCHEDULE 40 P.V.C. PIPE UNLESS
NOTED OTHERWISE.
4. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS
ARE WATERTIGHT. ANY POTENTIAL PLUMBING LEAKS SHALL BE
REPAIRED TO AVOID EXCESSIVE WATER ENTERING THE SEPTIC SYSTEM.
5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL
UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO
CONSTRUCTION AND EXCAVATION.
6. THE ABSORPTION TRENCHES MUST BE MARKED ANO PROTECTED TO
PREVENT DAMAGE FROM VEHICULAR AND LIVESTOCK TRAFFIC.
7. THE TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL
WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS
POINTS TO THE FINISHED SURFACE GRADE USING INSULATED LIDS..
INSTALL THE INLET AND OUTLET TEES TO BE EASILY INSPECTED AND
MAINTAINED FROM THE TANK RISERS AND ACCESS LIDS,
8. AN EFFLUENT FILTER SHALL BE INSTALLED IN
THE SECONDARY COMPARTMENT OF THE SEPTIC TANK. FILTER SHALL BE
MAINTAINED WHEN THE TANK IS PUMPED OR AS NEEDED. INSTALL
SUITABLE COMPONENT EXTENSIONS ON THE FILTER ASSEMBLY TO BE
NA THIN 12" BELOW THE ACCESS UD. WE RECOMMEND A PERIODIC
INSPECTION AND MAINTENANCE PROCEDURE BE PERFORMED EVERY 6
MONTHS.
8. THE ENTIRE TREATMENT BED SURFACE MUST BE SODDED OR
RE -VEGETATED WIThi GROUND COVER.
9. THE TREATMENT FIELD SURFACE MUST BE CROWNED TO DIVERT
SURFACE DRAINAGE AWAY FROM THE BED.
10. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND
SEPARATION DISTANCES FOR THE OWS COMPONENTS,
11. THE TRENCHES SHALL BE LEVEL WITH DISTRIBUTION PIPES INSTALLED FOR
EQUAL DISTRIBUTION.
12. THE TREATMENT BED SHALL BE CONSTRUCTED WITH THE 1N -DRAINS
UNITS PLACED W1TH A MINIMUM 6" LAYER OF CONCRETE SAND BELOW
AND ALONG THE SIDES OF THE UNITS. FILTER FABRIC SHALL BE
PLACED OVER THE 1N -DRAINS, AND DISTRIBUTION PIPE.
13.
THE MINIMUM COVER OVER THE TOP OF THE IN -DRAIN UNITS SHALL
BE 12 INCHES NOT TO EXCEED 30". THE TRENCH BOTTOM SURFACE
AND SIDEWALLS SHALL BE SCARIFIED AND RACKED IF SMEARING OCCURS.
14. THE TRENCH 1N -DRAIN UNITS WILL BE BACKF1LLED TO THE SURFACE
WITH EXCAVATED MATERIAL VOID OF ROCKS. THE BACKFILL MATERIAL
SHALL NOT EXCEED 3" DIAMETER. A MINIMUM 6" DEPTH OF TOPSOIL 15 TO
BE PLACED ABOVE THE BACKFILL TO THE FINISH SURFACE GRADE.
15. VERTICAL INSPECTION PORTS SHALL BE INSTALLED ON 11 -IE PERFORATED
DISTRIBUTION PIPE AT THE TERMINAL ENDS OF EACH TRENCH.
16. ALL INSTALLATION OF IN -DRAIN UNITS SHALL BE IN CONFORMANCE
WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS.
EXISTING DRIVEWAY
VEGATATI ON
DISTRIBUTION SYSTEM NOTES:
1. EFFLUENT FROM THE SEPTIC TANI< WILL DISCHARGE TO A DISTRIBUTION
BOX. EFFLUENT WILL BE EQUALLY DISTRIBUTED TO II -1E TREATMENT
TRENCHES \IA INDIVIDUAL 4" DISTRIBUTION LINES.
2. WE RECOMMEND THE INSTALLATION OF AN ORENCO SYSTEMS 4"
EFFLUENT FILTER CONTAINED IN THE TANK'S 4" OUTLET TEE.
THE FILTER SHOULD BE INSPECTED EVERY SIX MONTHS.
MAINTENANCE SHALL INCLUDE CLEANING THE FILTER EVERY SIX
MONTHS MINIMUM AND AFTER PERIODIC PUMPING OF THE TANK.
3. /HE DISTRIBUTION SYSTEM SHALL DISTRIBUTE FLOW EVENLY TO
EACH IN -DRAIN ENCH IN THE FIELD. THE MINIMUM SLOPE OF THE
DISCHARGE LINE FROM THE TANK TO THE DISTRIBUTION BOX
SHALL SHALL BE INSTALLED AT A MINIMUM 1% SLOPE. THE
INDIVIDUAL DISTRIBUTION LINES SHALL BE INSTALLED AT A
MINIMUM OF 2% SLOPE.
ALL DISTRIBUTION PIPING, CONNECTIONS AND FITTINGS SHALL BE
WATERTIGHT AND INSTALLED TO INSURE EQUAL DISTRIBUTION
THROUGH THE SYSTEM,
TOPSOIL LAYER
MIN. 5"
AERATED SOIL ZONE
FILL LAYER OF
NATIVE TOPSOIL
10"
FILTER FABRIC
INSPECTION PORT
EXISTING GRADE
PROPOSED GRADE
4" PERFORATED
DISTRIBUTION LATERALS
DWELLING
6' MIN.
TWO WAY CLEAN OUT
EFFLUENT FILTER
OUTLET TEE
PERFORATED PVC
DISTRIBUTION PIPE
IN -DRAIN UNIT
EXISTING HOUSE
'T
-17
('-'4 Cr i"
c)-ir
)Jr. • •
4"
STRAPPING
FINISH Fl OCiR
EFFLUENT DRAIN UNE
AT MINIMUM 2% SLOPE
SEPT C TANK
EFFLUENT DISCHARGE LINE
AT MINIMUM 1% SLOPE
DISTRIBUTION BOX W/
BAFFLE. MARK WITH PPE
RISER
DISTRIBUTION LINES
AT MINIMUM 2% SLOPE
CROSS SECTION SLOPE DETAII
N.T.S.
20MIN.-
CUSPATED PLASTIC CORE
SAND LAYER
CONC. SAND
NATIVE SOIL
R100'
LOAM & SEED TO PREVENT EROS
SCHEDULE 40 PVC 4" SDR -35 PIPE
WITH TIGHT JOINTS 10' MIN
2% SLOPE, 1/4" PER FOOT
,11,111 -
witmgmewmbai=
1000
i
CONCRETE SEP TANK
MAX. LIQUID DE' 5'-O"
• • •
VERTICAL VELOCIITY BAFFL
4" PVC WITH TIGHT 'OINTS
1% SLOPE, 1/8" PE F FOOT
INV. =
-.I I
TO DISTRIBUTION BOX
. TYPE A UNITS ARE 24"x48"
lall6" MIN.
SEE PLAN VIEW FOR NUMBER OF UNITS
FINISH GRADE =
OUTLET CONCRETE
-DISTRIBUTION BOX
EA
TO
1100011001111101110 cs
6" FILTER SAND BELOW IN-DRAN UINTS.
3/4"
SCREENED
ROCK
--1111-
NATIVE SOI
4" UNDER
DRAIN PIPE
TYPICAL SECTION OF PROPOSED ELJEN 1N -DRAIN SYSTEM
11 TRENCH
BE
STRUCTED LEVEL
FIL i ER FABRI
12" MI
MIN
I 24 II
4"PERFORATED
PVC (TYP)
iii
ism
MIN
INSTALLER SHALL INSTALL A 6" LAYER OF
MEDIUM TO COURSE CONCRETE SAND OR EQUIV.
SEE ELJEN IN -DRAIN DESIGN AND INSTALLATION MANUAL FOR DETAILS
TYPICAL CROSS SECTION
NOT TO SCALE
; • -
'
7"
6"
INSTALLATION NOTES
1. THE TREATMENT TRENCHES SHALL BE EXCAVATED
TO LEVEL GRADE.
2. THE WIDTH OF THE EXCAVATION SHALL BE
36' TO PROVDE 6" OF SAND BACKFTLL ON
EITHER SIDE OF THE IN -DRAIN UNITS.
INSTALL THE NON -WOVEN FILTER FABRIC
OVER THE DISTRIBUTION PIPE DOWN THE SIDES
OF THE IN -DRAIN UNITS.
3. BOTTOM OF THE TRENCHES SH ALL BE FREE OF
ORGANIC MATERIAL AND ROCKS OVER 3 INCHES
IN DIAMETER. THE BOTTOM OF THE TRENCH
SHALL BE SCARIFIED AND RAKED IF SMEARING
OCCURS.
4. THE IN -DRAIN UNITS SHALL BE INSTALLED
LEVEL END TO END WITH THE PAINTED STRIP
FACING UP.
5. INSTALL PERFORATED PIPE OVER THE TOP OF
THE IN -DRAIN UNITS ON CENTER AND SECURE
WITH ONE ELJEN CLAMP PER UNIT.
6. INSTALL FILTER FABRIC OVER PIPE AND TOP
OF 1N -DRAINS AND DRAPE DOWN THE SIDES
OF THE IN -DRAIN UNITS. BACKFILL OVER THE
FABRIC WITh CLEAN EXCAVATED FILL MATERIAL.
BACKFILL IN -DRAIN SYSTEM WITH SUITABLE
EXCAVATED FILL FREE OF ROCKS OVER 3
INCHES IN DIAMETER. AVOID EXCESSIVE
COMPACTION OF nu. AVOID COMPACTION
DAMAGE TO SYSTEM WITH EXCAVATION EQUIPMENT
8. FINISH GRADE TO PREVENT SURFACE
PONDING. REVEGATATE IMTH APPROPRIATE
GROUND COVER AND PROTECT FROM EROSION.
48' MAX.
7.
1N -DRAIN SYSTEM ABSORPTION BED
2266,01 BAL 0 ER SON -0 D 'NG 10/26/05
N
C3:
N.T.S.
////7
4/;6'ZIO"'PL
NO.
DATE
REVISION
BY
SOPRIS ENGINEERING, LLC.
CIVIL CONSULTANTS
502 MAIN STREET, SURE A3
CARBONDALE, CO 81623
(970) 704-0311
BALDERSON PROPERTY
17283 HIGHWAY 82
GARFIELD, COUNTY
ON-SITE WASTEWATER SYS DIM
SITE PLAN AND SYSTEM DETAILS
\
!:
DES. PER
CK. YTN
DR. PER DATE 10-26-05
FILE NO.
25266.01
SHEET 1
OF 1
INSPECTION PORT
EXISTING GRADE
PROPOSED GRADE
4" PERFORATED
DISTRIBUTION LATERALS
DWELLING
SCHEDULE 40 PVC 4" SDR -35 PIPE
TH TIGHT SLOPE, 1 /4 JOINTS PER
2%FOOT
4"DIA. PERFORATED DISTRIBUTION LATERAL PIPE
INSTALLED AT THE TOP CENTER OF THE IN -DRAIN
UNITS RUN THE FULL LENGTH OF THE TRENCHES.
ORIENT PERFORATIONS DOWNWARD AT 5 ANID 7
O'CLOCK. CAP END WITH SOLID 4" SWEEP
90'FITTING AND EXTEND A 4" INSPECTION PORT
RISER WITH CAP AT THE SURFACE ON ENDS OF
THE DISTRIBUTION PIPE IN EACH TRENCH.
TWO WAY CLEAN OUT
EFFLUENT FILTER
OUTLET TEE
INSPECTION PORT (TW
ABSORPTION/TREATMENT BED
USE 24 ELJEN IN DRAIN UNITS IM 2 TRENCHES
WITH 12 UNITS PER TRENCH. THIE IN -DRAIN
UNITS SHALL BE INSTALLED AT LEVEL GRADE
OVER 6" OF SELECT FILTER SAND IN A 150 SQ.
FT. TRENCH EXCAVATION (1YP.). THE SYSTEM
SHALL BE PLUMBED FOR EQUAL !DISTRIBUTION.
LAYOUT OF BED AND SOIL CONDITIONS TO BE
APPROVED BY THE ENGINEER PRIOR TO
INSTALLATION OF COMPONENTS. IMODIFTCAT1ONS
TO THE DESIGN OF SYSTEM WILL IBE DEPENDANT
ON ADDITIONAL GEO-TECHNICAL EVALUATIONS
AND ASSESMENT.
EXISTING HOUSE
FINISH FIIOCIR
EFFLUENT DRAIN UNE
AT MINMUM 2% SLOPE
SEPT C TANK
EFFLUENT DISCHARGE LINE FH
AT MINIMUM 1% SLOPE
DISTRIBUTION BOX W/
BAFFLE. MARK WITH PIPE
RISER
DISTRIBUTION LINES
AT MINIMUM 2% SLOPE
CROSS SECTION SLOPE DETAIL
N.T.S.
20' MIN.
0
5
GRAPHIC SCALE
10
20
40
EXISTING LAWN
. TYPE A UNITS ARE 24"x48"
( IN FEET )
1 inch = 10 ft.
ekl�111VG SE'M
50.0'
4" DISTRIBUTION LINES
6" MIN.
LOAM & SEED TO PREVENT EROSION
illi
I,1=111III=
1000 CAL.
CONCRETE SEP 10 TANK
MAX. LIQUID DEP fi 5'-0"
SEE PLAN VIEW FOR NUMBER OF UNITS
FINISH GRADE =
VERTICAL VELOCITY BAFFL
4" PVC WITH TIGHT JOINTS
1% SLOPE. 1/8" PER FOOT
VIII �ill.
INV. =
TO DISTRIBUTIOIN BOX
OUTLET CONCRETE
DISTRIBUTION BOX
' 0111111111141111
._.-. :.
.....
....,
. .:- :. • _
• i .=.--- Ili=
-, , ,=-1 1 , - , i ,
6" FILTER SAND
BELOW IN -DRAIN UINTS.NATIVE 501
#II
3/4"
SCREENED
ROCK
4" UNDER=
DRAIN PIPE
TYPICAL SECTION OF PROPOSED ELJEN IN -DRAIN SYSTEM
DECK
EACH TRENCH
TO BE
CONSTRUCTED LEVEL
FILTER FABRI
12" M
4" SEWAGE LINE
FROM HOUSE
0 2% SLOPE
0 -WAY
CLEANOUT
EXISTING HOUSE
MIN
6"
MIN
• NATI:VE..<SOf `.
DISTRIBUTION BOX W/
BUILT IN BAFFLE
& PIPE RISER TO SURFACE
* EFFLUENT UNE TO D -BOX
USE SDR -35 PIPE
INSTALL 1000 GAL TWO COMPARMENT CONCRETE
SEPTIC TANK. INSTALL EFFLUENT FILTER IN
OUTLET SANITARY TEE. INSTALL MINIUMUM 24*
DIAMETER RISERS OVER SEPTIC TANK ACCESS
OPENINGS FOR ACCESS TO TANK CHAMBERS. ALL
RISERS TO HAVE LIDS AT THE SURFACE. TANK
CONNECTIONS AND RISER TO BE WATERTIGHT.
EXISTING GARAGE
INSTALLER SHALL INSTALL A 6" LAYER OF
MEDIUM TO COURSE CONCRETE SAND OR EQUIV.
SEE ELJEN IN -DRAIN DESIGN AND INSTALLATION MANUAL FOR DETAILS
TYPICAL CROSS SECTION
NOT TO SCALE
EXISTING DRIVEWAY
EXISTING DRIVEWAY
R100'
VEGATAI1ON
TOPSOIL LAYER
MIN. 5"
AERATED SOIL ZONE
FILL LAYER 0
NATIVE TOPSOIL
FILTER FABRIC
PERFORATED PVC
DISTRIBUTION PIPE
IN -DRAIN UNIT
STRAPPING
CUSPATED PLASTIC CORE
SAND LAYER
CONC. SAND
NATIVE 30IL
OWS SYSTEM NOTES
1. ADD A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE.
2. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO COUNTY AND
THE STATE OF COLORADO INDIVIDUAL SEWAGE DISPOSAL. SYSTEM (ISDS)
REGULATIONS.
3. ALL SEWER LINES TO BE SDR -35 OF SCHEDULE 40 P.V.C. PIPE UNLESS
NOTED OTHERWISE.
4. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS
ARE WATERTIGHT. ANY POTENTIAL PLUMBING LEAKS SHALL BE
REPAIRED TO AVOID EXCESSIVE WATER ENTERING THE SEPTIC SYSTEM.
5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL
UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO
CONSTRUCTION AND EXCAVATION.
6. THE ABSORPTION TRENCHES MUST BE MARKED AND PROTECTED TO
PREVENT DAMAGE FROM VEHICULAR AND LIVESTOCK TRAFFIC.
7. THE TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL
WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS
POINTS TO THE FINISHED SURFACE GRADE USING INSULATED UDS..
INSTALL THE INLET AND OUTLET TEES TO BE EASILY INSPECTED AND
MAINTAINED FROM THE TANK RISERS AND ACCESS LIDS.
8. AN EFFLUENT FILTER SHALL BE INSTALLED IN
THE SECONDARY COMPARTMENT OF THE SEPTIC TANK. FILTER SHALL BE
MAINTAINED WHEN THE TAMC IS PUMPED OR AS NEEDED. INSTALL
SUITABLE COMPONENT EXTENSIONS ON THE FILTER ASSEMBLY TO BE
WITHIN 12" BELOW THE ACCESS UD. WE RECOMMEND A PERIODIC
INSPECTION AND MAINTENANCE PROCEDURE BE PERFORMED EVERY 6
MONTHS.
8. THE ENTIRE TREATMENT BED SURFACE MUST BE SODDED OR
RE -VEGETATED WITH GROUND COVER.
9. THE TREATMENT FIELD SURFACE MUST BE CROWNED TO DIVERT
SURFACE DRAINAGE AWAY FROM THE BED.
10. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND
SEPARATION DISTANCES FOR THE OWS COMPONENTS.
11. THE TRENCHES SHALL BE LEVEL WITH DISTRIBUTION PIPES INSTALLED FOR
EQUAL DISTRIBUTION.
12, THE TREATMENT BED SHALL BE CONSTRUCTED WITH T -IE IN -DRAINS
UNITS PLACED WITH A MINIMUM 6" LAYER OF CONCRETE SAND BELOW
AND ALONG THE SIDES OF THE UNITS. FILTER FABRIC SHALL BE
PLACED OVER THE IN -DRAINS, AND DISTRIBUTION PIPE.
13. THE MINIMUM COVER OVER THE TOP OF THE IN --DRAIN UNITS SHALL
BE 12 INCHES NOT TO EXCEED 30". THE TRENCH BOTTOM SURFACE
AND SIDEWALLS SHALL BE SCARIFIED AND RACKED IF SMEARING OCCURS.
14. THE TRENCH IN -DRAIN UNITS WILL BE BACKFILLED TO THE SURFACE
WITH EXCAVATED MATERIAL VOID OF ROCKS. THE BACKFILL MATERIAL
SHALL NOT EXCEED 3" DIAMETER. A MINIMUM 6' DEPTH OF TOPSOIL 15 TO
BE PLACED ABOVE THE BACKFILL TO THE FINISH SURFACE GRADE.
15. VERTICAL INSPECTION PORTS SHALL BE INSTALLED ON THE PERFORATED
DISTRIBUTION PIPE AT THE TERMINAL ENDS OF EACH TRENCH.
16. ALL INSTALLATION OF IN -DRAIN UNITS SHALL BE IN CONFORMANCE
WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS.
DISTRIBUTION SYSTEM NOTES:
1. EFFLUENT FROM THE SEPTIC TANK WILL DISCHARGE TO A DISTRIBUTION
BOX. EFFLUENT WILL BE EQUALLY DISTRIBUTED TO THE TREATMENT
TRENCHES VIA INDIVIDUAL 4" DISTRIBUTION LINES.
2. WE RECOMMEND THE INSTALLATION OF AN ORENCO SYSTEMS 4"
EFFLUENT FILTER CONTAINED IN THE TANK'S 4" OUTLET TEE.
THE FILTER SHOULD BE INSPECTED EVERY SIX MONTHS.
MAINTENANCE SHALL INCLUDE CLEANING THE FILTER EVERY SIX
MONTHS MINIMUM AND AFTER PERIODIC PUMPING OF THE TANK,
3. THE DISTRIBUTION SYSTEL:; SHALL DISTRIBUTE FLOW EVENLY TO
EACH IN -DRAIN TRC1. •;;IN Ir+ THE FIELD. THE ki;Pl!MUM SLOPE OF THE
DISCHARGE LINE FROM THE TANK TO THE DISTRIBUTION BOX
SHALL SHALL BE INSTALLED AT A MINIMUM 1% SLOPE. THE
INDIVIDUAL DISTRIBUTION LINES SHALL SE INSTALLED AT A
MINIMUM OF 2% SLOPE.
ALL DISTRIBUTION PIPING, CONNECTIONS AND FITTINGS SHALL BE
WATERTIGHT AND INSTALLED TO INSURE EQUAL DISTRIBUTION
THROUGH THE SYSTEM.
10"
J
[ ) Jr [ g -Jr )L -/C-
C cc
r[r (r -f
4"
1
7"
48' MAX.
6"
INSTALLATION NOTES
1. THE TREATMENT TRENCHES SHALL BE EXCAVATED
TO LEVEL GRADE.
2. THE WIDTH OF THE EXCAVATION SHALL BE
36' TO PROVIDE 6" OF SAND BACKFILL ON
EITHER SIDE OF THE IN -DRAIN UNITS.
INSTALL THE NON -WOVEN FILTER FABRIC
OVER THE DISTRIBUTION RPE DOWN THE SIDES
OF THE IN -DRAIN UNITS.
3. BOTTOM OF THE TRENCHES SHALL BE FREE OF
ORGANIC MATERIAL AND ROCKS OVER .3 INCHES
IN DIAMETER. THE BOTTOM OF THE TRENCH
SHALL BE SCARIFIED AND RAKED IF SMEARING
OCCURS.
4. THE IN -DRAIN UNITS SHALL BE INSTALLED
LEVEL END TO END WITH THE PAINTED STRIP
FACING UP.
5. INSTALL PERFORATED PIPE OVER THE TOP OF
THE IN -DRAIN UNITS ON CENTER AND SECURE
WITH ONE ELJEN CLAMP PER UNIT.
6. INSTALL FILTER FABRIC OVER PIPE AND TOP
OF IN -DRAINS AND DRAPE DOWN THE SIDES
OF THE IN -DRAIN UNITS. BACKFILL OVER THE
FABRIC WITH CLEAN EXCAVATED FILL MATERIAL.
7. BACKFILL 1N -DRAIN SYSTEM WITH SUITABLE
EXCAVATED FILL FREE OF ROCKS OVER 3
INCHES IN DIAMETER. AVOID EXCESSIVE
COMPACTION OF FILL. AVOID COMPACTION
DAMAGE TO SYSTEM WITH EXCAVATION EQUIPMENT
8. FINISH GRADE TO PREVENT SURFACE
PONDING. REVEGATATE WITH APPROPRIATE
GROUND COVER AND PROTECT FROM EROSION.
IN -DRAIN SYSTEM ABSORPTION BED
N.T.S.
25266.01 BALDERSON-OWS.DWG 10/26/05
.. �Fi7lt li Ell ��r�r
�.
•"� C'L* t':
117 / -
4"if:tftiniirk.:"
SOPRIS ENGINEERING, LLC,
CIVIL CONSULTANTS 1
502 MAIN STREET, SUITE A3
CARBONDALE, CO 81623
(970) 704-0311
NO.
DATE
REVISION
BALDERSON PROPERTY
17283 HIGHWAY 82
GARFIELD, COUNTY
1
BY
ON --SITE WAS I E WATER SYSTEM '\\
SITE PLAN AND SYSTEM DETAILS
DES. PER
CK. YIN
DR. PER DATE 10-26-05
FILE NO.
25266.01
SHEET 1
OF 1