Loading...
HomeMy WebLinkAbout03846' . .'-""<A''-<..<...'~'-"\" ~~~\_ Y BUILDING(~~~T~WR~~~;2mit N~ 3 8 4 6 GARFIELD COUN 109 8th Street Suite 303 Assessor's Parcel No. Glenwood Springs, Colorado 81601 Phone (303) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY This does not cons111ute a bu1ld1ng or use permit Owner's Name ~ckd-iY'Ar K 1 JqQ Present Address '8' 'J Afl'=lh<t ])I', tJ • C. \IC,~~one System Locat•on ____ ___,,,~_l--'"J----lftro'--'-T---' (_l1_-E'_br~~· -'k)'-=--''--'C"'-',...__,,<j(,_,('-=6'---lf'----,_Z ___ _ c2/J5 ~ )51-06 -001 Legal Description of Assessor's Parcel No. ------------------------------------- SYSTEM DESIGN Septic Tank Capacity (gallon) _______ Other Percolat1011 Rate (m1nu1es/inch) Number of Bedrooms (or other) _____ _ Required Absorption Area -See Attached Special Setback Reau1rements. Date _______________ Inspector ___ ---------------------------------- FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering lnstallatie~ ~\,-itvJ System lnstaller ___________________ ~---'--""~----lt-"'*-'~cl~-"-"+--------·------ Septic Tank Capacity _________________ _ Septic Tank Manufacturer or Trade Name ----------------------------- Septic Tank Access w1th1n 8" of surface ___ _ Absorption Area------------------- Absorption Area Type and/or Manufacturer or Trade Name----· --------------·----------- Adequale compliance with County and State regulat1ons/requ1rements ______________________ . Other LC/ _Q1 Date~--~+r-----.--~ Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDITIONS: All 1nslallat1on must comply with all requirements of the Colorado State Board of Health lnd1v1dual Sewage Disposal Systems Chapter 25. Article 10 C.R.S. 1973. Revised 1984 2 This permrt 1s vahd only for connection to structures which have fully complied with County zoning and building requirements Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a v1olat1on or a requirement of the permit and cause for both legal action and revocation of the permit. 3 Any person who constructs, alters, or 1nslalls an 1nd1v1dual sewage disposal system 1n a manner which involves a knowing and material variation from the terms or spec1f1cat1ons contained in the application of permit commits a Class I, Petty Offense ($500.00 fine - 6 months 1n 1a1I or both) White· APPLICANT Yellow. DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER LA() H1IV{)£1{T/f/IARI( ADDRESS [7 Afl+Cift' IJR. 11./&v LAS/Li PHONE qf(i[ -52(/6 CONTRACTOR /tSQi 1/ k RRTf-1 MtJi/1 If./ b I ADDRESS [(/ f /fa.Ou51?j PL, PHONE 9f -j-O] 7 1 PERMIT REQUEST FOR 9Q NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: NearwhatCityofTown 1/f W CAStLl SizeofLot tD.23l '>~t}l- Legal Description or Address~1S'~7~A<+-f~A~C..~f-.l~l,___~fJ~R~._____,_~E=-'-'/ K~· ~~~=e~k~l>e_v~·~B~J~7u~c~k~G,,___l_o_f-~7 __ WASTES TYPE: (>Q DWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ()OTHER-DESCRIBE _____________ , __ _ BUILDINGORSERVJCETYPE: R~7An.L Atzm1 Number of Bedrooms lf-Number of Persons ;2_ -=-c'----- ()Q_ Garbage Grinder ( )4.Automatic Washer (~Dishwasher SOURCEANDTYPEOFWATERSUPPLY: ( )WELL ( )SPRING ( )STREAMORCREEK If supplied by Community Water, give name of supplier: £ LK c..R..U.A.' l.juN]~ Dwf.f.:"i A~c,-c, DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:~2'--"--_,_fYh~~;f~£~.6.~------ Was an effort made to connect to the Community System? _0'}_._,,...(J:,,__ __________ _ A site plan is required to be submitted that indicates the following MINIMUl\1 distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table _______________________ _ Percent Ground Slope ___________________________ _ .... , TYPE OF INDIVIDUAL SEW AGE DISPOSAL SYSTEM PROPOSED: N SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POT ABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER-DESCRIBE FINAL DISPOSAL BY: c.:< ABSORPTION TRENCH, BED OR PIT ( ) EV APOTRANSPIRA TION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER-DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? __ PERCOLATION TEST RES UL TS: (To be completed by Registered Professional Engineer, ifthe Engineer does the Percolation Test) Minutes ____ _,,er inch in hole No. 1 Minutes ______ per inch in hole No. 3 Minutes _____ per inch in hole No. 2 Minutes ______ per inch in hole :"Jo._ Name, address and telephone of RPE who made soil absorption tests: -------------- Name, address and telephone ofRPE responsible for design of the sxstem: C /1urct-+ /tssc.-z. :)'03 -l/ b )-qJ i '7 ·1 <-/50 / Wo.ds<>Jortli t?i.id. Wh~oJ &dy-e ~ f~J!l Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented tu be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. fe'Zl ~1._~ Date ;/; r_/c,) ACCURATE MAP TO YOUR PROPERTY!! 1 ... ....._ ~ ..7 Designate North Arrow ---I I Your Plot • Shape to Fit (No Scale) Your Neighbor's Name & Address ~~- . (' . r ------- l I ' i ' I L _______ _ . \' . ,~ ~ x '( iT· _, i - / , ,. )( .f • ! I -i ,, « ' )( . . .)( , -. . . -' I . I~------- Locate well, all streams, irrigation ditchs:::~ 0 any water courses. -D , w in ~our 1 house, septic tank & system, detached garages, and drivew~y. , ·, , Ifa change of location is necessary, you must submit a corrected./lrawiii'g, befo're a Certificate of Occupation will be issued. / · '- County Road (Note the Road Number and Name) ~ J ~-r.._ .... ~ ~ . ~-T en~ c \WpW11160\wpdocslplot loc {3AJ ' Your Neighbor's Name & Address ..;)O/JJ' ,Do,·~~ r•11 Sj_J AfA4ff,J)( ·1 • • ( I N~rd rWkil ""9 k tlwwn •r 1'lmUd 0151 m4p ,, /uuJ ill!_ IJTtd pjM.~ 5.me rwuls "WJ iH priucu. ~"" Jlndn~nsrrum.m IMJll 'llrtClkaea ~phiu "' "' 1l ll E ' • u " • .L " 3 ...... l:-~~f-:;J-;.J-.f'=t-~~r::i.::--:::JL~Ji--j'1J1!f!i~!li!C::;:::;<;"'":;;;;.;;Ud.8~ ' """"'' Q -----• ''"" Umeterr • FROM : FRX NO. :3034639321 Sep. 10 2003 03:36PM Pl 4501 Wadsworth Blvd. VVheBt Ridge, C0.600:>3 Loveland 970-663-2124 FAX 97!>-663-2181 Cl Urgent D ForReview CC: -r ,,,.,., I< ~ ' Fax: Fax: Fax: 5--I~ 6"1 '-"\ S PAGES ! / 0 l [INCLUDING COVER SHEET! f,..nr. Date: CHURCH & ASSOCIATES, INC. Phone: 303463-9317 Fax: 303-463-9321 ~Requ..ted DPlaaseReply FROM : FAX NO. :3034639321 Sep. 10 2003 03:36PM P2 ~r;HURCH & Associates, Inc. ENGINEERS & GEOLOGISTS September I 0, 2003 Aspen Earthmoving, LLC, Attn: Tony Francello PO Box 1090 Carbondale, Colorado 81623 Su~iect: Subsurface Investigation and OWS Repair Design, Existing Residence 0087 Apache Drive, Town ofNew Castle Garfield County, Colorado Job No. I 5955 Mr. Francello, As requested, we have investigated subsurface conditions and designed a repair onsite wastev.iater system (OWS) for the existing residence. The subsurfilce investigation was performed on September 3, 2003. SITE CONDIDONS The lot is located in a rural residential area in Garfield CO\lllty, Colorado, where OWS are require& The proposed drain field area has a 300/o to 35% slope to the east There is a sparse cover of native grasses and weeds-with scattered juniper. PROPOSED CONSTRUCTION A fuur-bech oom residence, septic tl!ak; and drywell· exist at the locations presented· on Figure I . It is anticipated that the existing septic tank will have to be abandoned; however, if the tank is found to be in good condition and is a minimum of 1250-gallons irr si=witlr1wo· compartments; the tank may be used· for this design. The existing diywell must be abandoned. In accordance with the Individual Sewage Disposal System (ISDS} regulations, the average· sewage loading for JI: four-bedroom residence is 600 Gallons fer Day (GPD) and 900 GPD with a l.5 peaking factor. This loading includes a dishwasher, garbage grinder, and washing machine. Water is provided to the residence by the local water district. SUBSURFACECONDIDONS The subsurface investigation was performed a by digging three percolation holes, 44 to 52 inches deep, and one test pit at the locations indicated on Figure 2. Subsurface materials in the test pit consisted of 2 feet of silty, sandy clay underlain by intensely weathered shale bedrock to the maximum depth explored of7.5 feet. No ground water or bedrock was encountered. Percolation tests indicate percolation rates of 14 to 40 minutes per inch (MPD. The average percolation rate is 25 MPI. Percolation data is presented in Table 1. RECO:MMENDA TIONS The installation must include a septic tank, an effluent filter, and a gravelless chamber-trench drain field at the locations presented on Figure 2. The OWS design is based on an average sewage load of 600 GPD and a percolation rate of 25 MPI. The installation must include a 1250-gallon, two- compartment, septic tank with an effluent tilter on the outlet and three chamber-trenches using serial overflow distribution. Each trench must have one row of I 0 chambers for a total of 30 chambers and DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.83!7 Fox: 303.463.9321 www.gao-church.com Toll Froe-t.an.24&.3123 FROM FRX NO. :3034639321 Sep. 10 2003 03:36PM P3 OW.~ :R!lpllir nPoi.e:n Job No. 15955, 9/10103 Page 2 465 f\2 of infiltrative area. Trenches must be installed no deeper than 3.5 feet. The trenches may be modi£ed to confonn to topography and to preserve as much vegetation as possible. Jt is understood a plastic septic tank will be used because of access at the site. Plastic tanks must be bedded with pea gravel to the tank outlet and filled with water as the tank is being backfilled to reduce distortion of the tank. If the existing septic is used an effluent filter must be added to the outlet. Movement over the drain field trench during construction should be kept at a minimum to reduce compaction of the receiving soils. The bottom of each trench must be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition-of chambers. OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service and nmst assume the responsibility for maintenance of the OWS. The system is relatively maintenance free, but the owner must have the septic tanks pumped. In the absence-of a-111011it01iug program, the septic tank should be pumped and the effi\tent filter deaned every two years. There are daily considerations, such as not putting plastic or other nonbiode- gradable material into the OWS. Water U8C must be monitored so toilets are not allowed to run·when seals malfunction. To illustrate the point, a running toilet can consume in excess of l 000 GPO. A loading of 1000 GPD could flood and irreparably hann the OWS. The loading from the backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed fur the back-wash waste, if a softener is installed. Chenllcally treated water from a swi1muing pool or spas should not be introduced to the OWS. LIMITATIONS Arr OWS design-requires installntion by n licemed· contractor. Our investigation, layout, design and rect)m- mendations are based on data submitted. If conditions different from those described in this report are encountered, we should be notified to evaluate the effect on the proposed OWS. If the health departm,ent modifies this design. we should be contacted to evaluate the impact on the pe:rfonnance of the OWS. All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requiremC\)ts. septic tank consn1Jction, and other specifications, which are not depicted in our report, are to confonn to the requirements of the TSDS regulations. The installer of the system is to have demonstrated knowledge of the LSDS regulations and requirements. Ifthere are questions or if we can be of further service, please call. CHURCH & Associates fnc. EricR Burns Design Technician EOC/trp/erb 3 copies sent I copy faxed to 970-963-224 7, Attn: Tony Francello FROM : FRX NO. :3034639321 Sep. 10 2003 03:37PM P4 w > gs OOS7 APACHE DRIVE TOWN OF NEW CASTLE GARFIELD COUNTY, COLORADO NOTTO SCALE I I I 0113 APACHE DRIVE I -i j 0087 -;_;_;-AMD~l.;E-- - - - - - - - - - - - - - - - - - - - I I I EXISTING t.-BEDROOM RESIDENCE 30% -35% SLOPE !:t! I ~ I <1 l. ............ ::::: Li w.Al.JC: ... ; EXISTING GARAGE I i ::lRIV::WAY r· .............. . I D 0 EXISTING SEPTIC TANK EXIS-:-ING DRY WELL --------' OOBIAPACriEDRIVE I I ---------------~ I I I THE LOCATION 01-EXISTING ANi) PROPOSED IMPROVEMENTS SHOWN HEREIN AND THE WE'...L AND/OR DRAIN FIELD LOCAllONS STAKED AT THE SITE ARE NOT "'."HE RESULT OF A PROPERTY SURVEY. IMPROVEMENT LOCATIONS ARE APPROXIMATE. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO D::FINE PROPERTY BOUNDARIES AND ENSURE ALL ONSITE IMPROVEMENTS ARE LOCATED WITHIN THE PLATTC:D SIT~ AND OUT OF INAPPROPRIATE EASEMENrS. ALL SEPARAilON DISTANCES AR!: TO BE VERIFIED ?RIDR TO EXCAVATION. SITE PLAN AND LOCATION OF EXISTING JOB NO. 15955 OWS FIGURE 1 I FROM : FAX NO. :3034539321 Sep. 10 2003 03:37PM PS 0087 APACHE DRIVE NOTTO SCALE TOWN OF NEW CASTLE GARFIELD COUNlY, COLORADO I 465 SQ. FT. OF INFILTRATIVE AREA IN A GRAVELLESS CHAMBER-TRENCH DRAIN FIELD. EACH TRENCH MUST HAVE ONE ROW OF 10 CHAMBERS FOR A TOT AL OF 30 CHAMBERS I I I I ~~~~~v: _________________ _ I 0087 APACHE DRIVE I ---1 I I I ~i EXISTING 4-BEDROOM RESIDENCE !fl I u1 ~ l .... _____ ::::::.: :::E:X;~~~~OuT j I • SERIAL OVERFLOW i_'NE OBSERVATION/VENT PIPE (TYP.) 4" PVC SEWER l_INF TESTI PIT I GARAGE o. I DR IVEWA y ----------------- r · · ----· --· -------- ~---+------' ? z I I I I I I I bl EXISTING DRY WELL (TO BE A3ANDONED) 4" PVC I ----------1 --------------E=E~~~ I APACHE DRIVE I I I JOB NO. 15955 PROPOSED 1250-GALLON, TWO-COMPARTMCNT PLASTIC SEPTIC TANK WITH AN Eff'_UENT FILTER AT THE OUTL::C:T (IF EXISTING TANK MUST BE ABA"JDONED) EXISTING SEPTIC TANK MAY B:: USED IF FOUNJ TO BF. IN GOOD CONDITION AND MEETS DESIGN REQUIREMENTS. AN EFFl.UENT FILTER MUST 3E ADDED TO THE OUTLET. LOCATION OF PERGOLA TrON HOLES AND PROPOSED OWS FIGURE 2 FROM : TYPICAL PLAN VIEW -N.T.S. 3' 0 4" SDR 35 PVC OBSERVATION/VENT PIPE TYPICAL CROSS-SECTION -N.T.S. FAX NO. :3034639321 GRAVELLESS CHAMBER 3' Bi' 6.25' ACKFILL 3 5' MAX CALCULATIONS AND SPECIFICATIONS DESIGN CR1T:R1A RESIDENCE = 4 BEDROOMS LOADING = 75 GAL/DAY/PERSON TOTAL LOA:JING = a = 600 GPD PERCOLATION RATE = T = 25 MPI AREA = ((I. 75 X 600) X SQRT 25)/5 = 900 SF 50% REDUCTION FD~ TRENCHES = 450 SF TREATMENT U'llT SPE:IFICATIONS 0 Sep. 10 2003 03:37PM P6 4" PVC EF"LU::NT INLET (;/8" PER FOOT DROP) TOTAL-THREE TRENCHES 4'1 SDR 35 ~vc BSERVATION/VENT PIPE WITH CAP GRAV[LLCSS CHAr1B=R 3' BY 6.25' TRENCH SPECIF 1CA:IONS NUMBER OF TRENCHES - 3 LENGTH OF cACr TRENC'1 -62.5 F::::::T. 10 CHAMBERS WIDTH OF EACH TRENCH -3 C'EET, I CHAMBrn TOTAL NUMaER OF O-AMBE~S • 30 CHAMBERS TOTAL AREA -465 SF TOTAL MINIMUM CA~ACITY -25C 1 (4 S::DROOMS X 250 GALLONS)= l?.50 GALLONS RECOMMENDATION -ONE l?.SO-GALLON, 7W0-COMPhRTMENT. PLASTIC SEPTIC TANK WITrl AN EFFLUENT FIL Tfl< ON Tl-IE O'JTLET. JOB NO. 1 5955 DRAIN FIELD DETAILS Typical Septic Tank Diagram with 4" Dia. Biotube® Effluent Filter 1250-Gallon, Two-Compartment, Septic Tank with Effluent Filter Inspection Access Riser and Lid (al or rreor ground surlace), optional " Tank Adapter (cost or bolled) Inlet Tee-----... < ii ~ 2· J Sp rice Box w /Cord Grips Fiberglass Gasi<e!ed Lid with Stainless Steel Bolts Slope Ground Away From Riser PVC Riser with Grommel(s) (bond to lank adapter wah .;;.~=====------""F9~,£,===w.L--recommended adhesive) Conduit la -= Alarm Panel ,.--fitter Cartridge Handle (field ClJ! lo desired height) Conduit Seal ___,, Effluent Discharge ~ r Modulating Discharge Orilices H--t---VauH lnlel Ports Clear Zone Opening in the Baffle is on acceptable alternative lo PVC tees Patents I 1,4J9,J2J & 5,492,635 Foreign Patents Pending <i:l 1997, Orenco Systems, Inc. JOB NO. 15955 Filter Cartridge ----~ ~--FT0400 Series BiollJbe Etnuent fitter DISCLOSURE: THE PRESIDEITT OF CHURCfl & ASSOCIA1£$, INC. IS A SHAREKOLDER OF SCG ENTERPRISES, INC. WHICH IS A LOCAL DISTRIB\JTOR Of ORENCO ~S, INC. PRODUCTS. ~ ~ ~ @·--~ "-.. . ' Orenco Systems" lnoorporafed 814 NIMAY A'<Uj\.1£ ~.!HQJN 97479-9()12 IIlEPllON[: (541) 459-- fM:SIMllf: (541) 459-2884 FIGURE 4 ~ ,, D x a .. :.;f ~ CTI [..J \JJ [..J r\J .... (f) .\j .... IS) § IS) [..J ~ .,, 3 .,, ..J FROM : ' • PRO· 1: HOLE NUMBER 1 2 3 FAX ND. :3034639321 Sep. 10 2003 03:38PM PB TABLE 1 -PERCOLATION TEST RESULTS 87 Apache Dr. DATE OF TEST: 9/3/03 Garfield County, Colorado feet descrlntlon 0-2 Clav, sandv, siltv 2. 7 5 lntenselv weathered shale bedrock, siltv NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION DEPTH TIME DEPTH DEPTH INTERVAL OF HOLE INTERVAL START END CHANGE, PERC. (INCHESl (MINUTES)' (INCHES) (INCHES) (INCHES) RATE (MPI) 44 20 40.00 44.00 4.00 5 20 39.50 44.00 4.50 4 20 38.75 41.00 2.25 9 20 39.25 41 .25 2.00 10 20 39.50 41.00 1.50 14 20 41.00 42.50. 1.50 14 52 20 47.75 49.00 1.25 16 20 47.75 49.00 1,25 16 20 47.75 49.00 1.25 16 20 47.50 48.50 1.00 20 20 47.50 48.50 1.00 20 20 48.50 49.50 1.00 20 51 20 46.50 47.25 0.75 27 20 45.50 46.25 0.75 27 20 46.25 46.75 0.50 40 20 46.75 47.25 0.50 40 20 46.50 46.75 0.25 80 20 46.75 47.25 0.50 40 AVG. HOLE PERC. RATE, IMPI\ 14 20 40 JOB NO. 15955 Oct. 23. 2006 10:2·1A\1 'Aspen '.irt1 Mov n5 · ~h<;-~URCH & Associat~, Inc. ENGINEERS & GEOLOGISTS January 9. 2004 Aspen Earthmoving, llC, Attn: Tony Francello P.O. Box 1090 Carbondale, Colorado 81623 Subject: Installation Observation, Existing Residence 0087 Apache Drive, Town of New Castle Garfield County, Colorado Job No. 15955 Mr. France!lo, h 1792 ' 2 ;o3~~v As requested, the installation of the onsite wastewater system for the subject site was observed on November 4, 2003. The system was designed under Job No. 15955, dated September 10, 2003. The system includes the installation of a 1250-gallon, two-compai1ment, plastic septic tank with an effluent filter on the outlet, and three gravelless chamber-trenches each with 1 row of 10 chambers for a total of 465 square feet of infiltrative lll'ea. Serial overflow lines were installed at the end of the first two trenches. An as-built drawing is included as Figure 1. The trench was completed, but the new sewer line and cleanout had not been installed at the time of the observation. The observed components of the OWS were installed m general confonnance with the design. The installation observation does not imply a guarantee or warranty of materials or workmanship. Sincerely, ClillRCH & Associates, Inc. Reviewed by Bric R. Burns Field Techoician Edward 0. Church, P.1'C~.;;-. EOC/erb 2 copies sent Copy to Garlield County Building and Sanitation Department 108 811> Street, Suite 201, Glenwood Springs, CO 81601 DENVER 4501 Wodaworth Boulevard W~ell Flldge, CO 80033 303A83.8317 Fu: 3W.463.9321 ...... _""_ www.gaoechurch.corn Toll Fr~ -1.B77.2llll.3123 Oct. 23. 2006 10:2UM Aspen tarlh MJvi1g ( 0087 APACHE DRIVE TOWN OF NEW CASTLE GARFIELD COUNTY, COLORADO EXISTING SEWER LINE EXISTING RESIDENCE ( No. 1792 P 3 SCALE 1" = 20' EW SEWER LINE AND CLEANOUT NOT INSTALLED AS OF 1211712003 ERIAL OVERFLOW LINE 1250-GALLON, TWO-COMPARTMENT, PLASTIC SEPTIC TANK WITH AN EFFLUENT FILTER ON THE OUTLET JOB NO. 15955 465 SF OF INFILTRATIVE AREA IN 3 GRAVELLESS CHAMBER-TRENCHES WITH SERIAL OVERFLOW DISTRIBUTION. EACH TRENCH HAD I ROW OF 10 CHAMBERS. AS-BUil T DRAWING FIGURE 1