Loading...
HomeMy WebLinkAbout04157,3/027/06 ttP.Yr5o. ob _1 Wd9ti:E C '1d i¢panleeed• %(—j GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suits 201 Glenwood Springs, Coloradof 81601 Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY y� Owner's Name 7j7ii,< //'c,/1 ., Present Address 372 /1(i C. 137 ( � System Location Q a -5-e z .24100 I'1 Legal Description of Assessor's Parcel No Permit 4157 Assessor's Parcel No. ThIs does not constitute a building or use permit. CPhone J C. C mon [tru. to) SYSTEM DESIGN ho=t7. Septic Tank Capacity (gallon) Percolation Rate (minuteslinCh) Required Absorption Area - See Attached Special Setback Requirements: Date 14 Other Number of Bedrooms (or other) Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity c�<;p[2rJc_ Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface �� S Absorption Area Absorption Area Type and/or Manufacturer or Trade Name 547& c• -r- 2 T" ,A r -,-ti 't Adequate compliance with County and State regulations/requirements . e Other Date Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1944, 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements, Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner whlch Involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class t, Petty Offense ($500.00 fine— 8 months in jail or both). 1.111 -Ito ADCA Ir. AAIT V.,IL.... nto A O-riIT INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER k vv e ADDRESS %2, NVIO Ccte�- U �,A ( ij/6.S%PHONE 7 7 (790? CONTRACTOR `; '{-- , c S c ADDRESS ! 7� �% r i �% ; ( 0 G /(f 7 PHONE r/ ) 0 1/7 9 -73 0 Ci PERMIT REQUEST FOR (<NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town Ly L - Size of Lot L } Legal Description or Address L\ Li H C0t, J- y ? cto 7 WASTES TYPE: (L --DWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER—DESCRIBE BUILDING OR SERVICE TYPE: cS Number of Bedrooms L1 Number of Persons f. { (t4' Garbage Grinder ( ) Automatic Washer (0shwasher SOURCE AND TYPE OF WATER SUPPLY: (&- WELL ( ) SPRING ( ) STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: 7 v,`, 3 Was an effort made to connect to the Community System? KJ a A site ' lan is re i uired to be submitted that indicates the followin • MINIMUM distances: Leach Field to Well: Septic Tank to Well: Leach Field to Irrigation Ditches, Stream or Water Course: Septic System (septic tank & disposal field) to Property Lines: 100 feet 50 feet 50 feet 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table Percent Ground Slope 2 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( SEPTIC TANK ( ) AERATION PLANT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) CHEMICAL TOILET( ) OTHER -DESCRIBE VAULT RECYCLING, POTABLE USE RECYCLING, OTHER USE FINAL DISPOSAL BY: ( :.-)' ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER -DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE* PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Name, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Ay, ((2) u J Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health depai talent to be made and famished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, infoiination and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local depar talent of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed , [ �, , — Date � j 12 710 6PLEASE DRAW AN CCURATE MAP TO YOUR PROPERTY!! 3 Feb. 8. 2008 4:48PM HIGH COUNTRY ENGINEERING CIVIL ENGINEERING May 23, 2007 Andy Schaller Garfield County Environmental Health 108 8th Street, Suite 201 Glenwood Springs, CO 81601 An Empl•ro-Owoc cunw.ny Re: Okanela Ranch ISDS HCE Project Number 2021708.00 Dear Andy: No.2401 P. 2 LAND SURVEYIN The following letter is to confirm the engineer's acceptance of the designed septic system of he Okanela Ranch near Canyon Creek Road. The design included a 1,250 gallon septic tank, and 63 Quick 4 infiltrator units. All of the inspection wells, infiltrators, manifolds, and cleanouts - e inspected and were installed satisfactory. The infiltrator configuration was changed due to le existing site conditions, and is shown per the attached as -built drawing. With the above -noted changes, the system has been completed with the intent of the ori design. If you have any questions, or need additional information, please contact us. Sincerely, HIGH COUNTRY ENGINEERING, INC. Roger eat Seri roject Manager RDN/blf Enclosure 1 E 17 awce Avenue, 6Un-r 101 GLinw000 SP1uNa6, C0 81001 9709458070•FLwnc 9709454555 • FAX www.HcEH0.COM 141NVENFESU DRrv. EAST Sunt F.I20 ENOLEw000, Co 801 12 3039250544• PHONE 3034250547•FAw ir00 i 58Q I. 1 1 I L DISTRIBUTION LATERAL (TYP. • ONE 2000—GALLON — SEPZLC .TANK.. ONE 1000—GALLON SEPTIC T DRAIN FIELD INSPECTION WELL (TYP, I I I I 0 r 4"0 PVC SEWER (TYP.) ` ....... — _ ---- __ PROVIDE POSITIVE DRAINAG AWAY FROM ABSORBTION FIELD 14 UNITS f l ji 1 fi 1 I I L I I 1• r7/ CLEANOUT (TYP) J I 7// 1 ( {( 8'" MIN. FROM'CREEK Fr 148' MIN / II' Ell I=I=En II= MNMN=II In MI ICE NM l=1• _Rtt•MIMIt•OEN i i I I f 1 I 1 1 1 1 25' MN TO DR►NkING WA -TE SUPPLY LINE APPROXIMATE LOCATION PER, ARCHITECT 1) TO WEt. 1 1/4" SCHD 80 /4VC PPROXIMATELY 600E WITH TR E. WI ,1 INIMUI/ 6— T BURY DEP INSTAL . BLIEB OARD . IF `$ 1 MINIMUM OF 10—FT FROM DRIy4CING Wi TER SUPPLY ONE ST Ij'iIMUM 30 5,790 • TABLE II TABLE OF MINIMUM HORIZONTAL DISTANCES IN FEET BETWEEN COMPONENTS OF A SEWAGE DISPOSAL SYSTEM INSTALLED AFTER NOVEMBER 15, 1973 AND PERTINENT PHYSICAL FEATURES NOTE. The minimum distances shown above shall be main wined between the system components and the physical features described. Where soil, geological or other conditions warrant, greater distances may be required by the local board of health or by the Water Quality Control Commission pursuant to C.R.S. 25-8-206 in accordance with the authority prescribed by law and rules and regulations implemental of said section. Components which are not watertight should not extend into areas of the root system of nearby trees. For repair or upgrading of existing systems where the size of lot precludes adherence to these distances, repaired facility shall not be closer to water supply components than the existing facilities (1) I.listance shown shall not apply to treatment plants or effluent fines where recycling is permitted 60 0 15 30 50 120 ( IN FEET ) 1 inch = 30 ft. REMOVABLE PVC CAP INSTALL MARKER IF CAP IS TO BE BURIED, FINISH GRADE 4" COUPLING 4" SEWER LINE 4" x 4" x 4" PVC WYE 4" RISER — 4" 45' SWEEP BEND CLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N.T.S. FIELD JOINT REQUIRED FOR MODELS 2014-129 & 2014-160 ACCESS WAY VENT STRAIN RELIEF CORD CONNECTOR POWER 8t ALARM CABLE 12-6 W/GND 20T4 NO [BAFFLE WATER TIGHT LID, FRP DUAL WALL, CORRUGATED HDPE ACCESSWAY ELECTRICALAQUI (E DISCONNECT N INLET, GROMMET TO ACCEPT 4,50" 0.0, PVC PIPE (STANDARD). DUST COVER SUPPLIED FOR SHIPMENT (NOT SUITABLE FOR BURIAL) INTERNAL WELL VENT 2.0* DIA. CORE CONTROL COMPARTMENT BREATHER DISCHARGE 1 1/4" FPT (304 S.S.) QUICK DISCONNECT ASSY. (304 5.5.) S.S. CAST BALL VALVE 42.8in 1087rrrn OISCH ALARM 31.Sin 800mm 28.5in 1 1/4" DISCHARGE LINE . (304 5.5.) CHECK VALVE (GLASS FILLED PVC) ANTI -SIPHON VALVE (GLASS FILLED PVC) ON 724mm 106gol 401 L 20.5in 18.5in 521mm 420mm 74 gal 58 gal 280 L 220 L HDPE TANK 1/2' NOMINAL WALL THICKNESS 150 GALLON CAPACITY SEMI -POSITIVE DISPLACEMENT EACH DIRECTLY DRIVEN BY A CAPABLE OF DELIVERING 9 gpm (34 Ipm TYPE PUMP 1 HP MOTOR AT 138' T.D.H. AT 42m T.D.H,) BALLAST REQUIREMENTS A CONCRETE ANCHOR 15 RE UIRED ON ALL OUTDOOR MODEL 2014 A IONS SPECIFIC CONCRETE DIMENSIONS ARE REQUIRED TO ACHIEVE NECESSARY BALLAST EFFECT SEE INSTALLATION INSTRUCTIONS FOR FURTHER DETAILS SGS DR BY CAH 03/22/03 A 1/16 CIiK"O DATE ISSUE SCALE one SEWER SYSTEMS MODEL 2014, NO BAFFLE, DETAIL SHEET PAO910P02 WELL SETBACK GARFELD COUNTY) AEA OF F1FLUENCE PEA STATE GUIDELINES) PROPOSED FIELD: PROPOSED HOUSE). TOTAL AVERAGE DAILY FLOW = 1,050 GPD AREA OF INFLUENCE DESIGN FLOW 1,050 GPD * 1.5 = 1,575 GPD FOR FIRST 1,000 GPD: 100 FEET ADD 8 ADDITIONAL FEET FOR EACH 100 GALLONS PER DAY OF AREA OF INFLUENCE FLOW OVER 1,000 GALLONS 575 / 100 = 5.75 6 * 8 = 48 FEET 48 FEET + 100 FEET = 148 FEET (AREA OF INFLUENCE) STREAM SETBACK ODER GARFIELD COUNTY) PROPOSED FIELD: (PROPOSED HOUSE) TOTAL AVERAGE DAILY FLOW = 1,050 GPD AREA OF INFLUENCE DESIGN FLOW 1,050 GPD * 1,5 = 1,575 GPD FOR FIRST 1,000 GPD: 50 FEET ADD 8 ADDITIONAL FEET FOR EACH 100 GALLONS PER DAY OF AREA OF INFLUENCE FLOW OVER 1,000 GALLONS 575 / 100 = 5.75 6 * 8 = 48 FEET 48 FEET + 50 FEET = 98 FEET (AREA OF INFLUENCE) (2) Crossings: or encroachments niay be permitted at the points as noted above provided that the water conveyance pipe is encased for a minimum distance of ten (ID) feet on each siide of the crossing- A length of pipe shall he used with a minimum Schedule 40 rating of sufficient diameter to easily slide over and completely encase the water conveyance. Ridged end caps of at least Schedule 40 rating must be glued or secured in a watertight fashion to the ends of Me encasement pipe. A hole of sufficient size to accommodate the pipe shall be drilled in the lowermost section of the ridged cap so that the conveyance pipe rests on the bottom of the encasement pipe- The area in which the pipe passes through the endcaps shall be scaled with an approved underground sealant compatible with the piping used. Add 8 feet additional distance for each 100 gallons per day of design flow over 1000 gallons per day as specified in the table, unless it can be demonstrated by a registered Professional Engineer or Geologist that a mechanical or natural barrier will prevent enntamination. (3) (4) Encroachments may be permitted provided the water or wastewater conveyance pipe is encased as in (2) above, specified in the table. ggNERAL ABBOFFMON TRENCH NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2, THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. 3, DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA, 4. TRENCH LATERALS SHALL FOLLOW CONTOURS. 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7 NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED, 8. UNSUITABLE MATERIAL EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT—RUN MATERIAL. 9. IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIO—MAT. 10. BENDS IN TRENCH SHALL BE MADE WITH END PLATES AND 4"16 PVC OR MANUFACTURER'S PREFABRICATED BENDS. VICINITY MAP SCALE: 1"=3000' geteiALIIXIMI 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. TFIE EXISTING ISDS SYTEM WAS DESIGNED FOR A 7 BEDROOM HOUSE AND 5 HORSE STALL BARN. THE EXISTING 1505 SYTEM WAS ASBUILT 6-33-06 BY HIGH COUNTRY ENGINEERING AND ACCEPTED BY GARFIELD COUNTY. THE EXISTING HOUSE I S ONLY 5 BEDROOM AND THE 5—HORSE BARN WAS ELIMINATED PER CLIENT EMAIL DATED 4/28/06. THE REDUCTION IN THE EXISTING HOUSE ALLOWED FOR THE PROPOSED 2 BEDROOM POOLHOUSE TO TIE INTO THE EXISTING FIELD. 3. FLOW FOR EXISTING 5 BEDROOM HOUSE (5 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY) IS: 750 GPD = AVERAGE DAILY FLOW. FLOW FOR THE PROPOSED 2 BEDROOM POOLHOUSE (2 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY) IS: 300 GPO = AVERAGE DAILY FLOW. TOTAL DESIGN FLOW = 1,575 GPD SEPTIC TANK FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM: MINIMUM TOTAL TANK SIZE: * 1 DAY/24 HRS * 30 HRS = 1,969 GPD EXISTING ONE 2,000—GALLON COPELAND CONCRETE SEPTIC TANK IN SERIES WITH ONE 1000—GALLON COPELAND CONCRETE SEPTIC TANK WITHOUT BAFFLES. ***INSTALL EFFLUENT FILTER IN OUTLET*** STANDARD ABSORPTION AREA PER EACH SYSTEM: t=PERCOLATION RATE = 60 min./in. 5 INCREASE FIELD AREA BY 20,t TO ALLOW FOR GARBAGE GRINDERS: 2,439 SF * 1.2 = 2,928 SF 30% REDUCTION FOR USE OF STANDARD INFILTRATOR UNITS IN TRENCH CONFIGURATION 'YIELDS 2,050 SF 0 15.5 S.F./UN1T, 133 UNITS REQUIRED. EXISTING FIELD CONTAINS 164 UNITS. 4. WET WELL SIZING 300 GPO = AVERAGE DAILY FLOw. 450 GPO 4 DOS1NGS/DAY 15 113 GALLON WET WELL DUE TO THE POOLHOUSE DISCHARGE LINE DEPTH THE 4 FT DIAMETER WET WELL SHOULD HAVE A TOTAL STORAGE DEPTH OF 6 FT. TWO S10/4W PIRANHA GRINDER PUMPS SHOULD BE USED_ LINE FROM WETWELL TO SEPTIC TANK WILL MUST CONTAIN A BACKFLOW PREVENTER, 5. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 7, TOPSOIL COVER MAY BE VARIED (OATH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE—HALF FOOT OF FINAL GRADE. 9. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED, 10, PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 11. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR 10 BACKFILLING OF SYSTEM COMPONENTS. 12, SOIL AND PERCOLATION INFORMATION PROVIDED BY H.P. GEOTECH, INC., JOB NO, 103 377, DATED MARCH 25, 2004. 13, THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT, PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY, 14, THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY, BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 15, SITE PLAN INFORMATION PROVIDED BY CLIENT. 16, INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 6.0 FEET. 17, EXISTING 1505 FIELD LOCATION PER HIGH COUNTRY ENGINEERING SURVEY. 18. PROPOSED DOSING TANK AND 2—IN EFFLUENT LINE 10 BE SURVEYED PRIOR TO ACCEPTANCE. 19. TRACING WIRE TO BE INSTALLED %PATH 2—IN EFFWENT LINE. 20. EXISTING WELL PER CLIENT IS LOCATED APPROXIMATELY 20—FT NORTH OF EXISTING 5—BEDROOM HOUSE. o 0 AS-BUILT DRAWING co az 0 0 0 0 LLJ 0 PROJEC 202170 Spring, Wells, Suction Lines Potable Water Supply Line Potable Water Supply Cistern Dwelling Occupied Building Property Lines, Piped or Lined Irrigation Ditch Subsoil Drains, Intermittent Irrigation Lateral Lake, Water Course, Irrigation Ditch or Stream Dry Gulches Septic Tank Dispersal System Utilizing (3) (4)(2) (3) (3) Aerosol Methods 100 10 50 125 10 0 25 10 10 Seepage Pit or Slit Trench (3) . (4)(2) (3) (3) 100 50 25 20 25 10 50 25 6 Absorption Trench, Seepage (3) (4)(2) (3) (3) Bed, Sand Filter, Sub -surface 100 25 25 20 10 I0 50 25 6 Dispersal System, or Diywell Unlined Sand Filter in Soil (4)(2) With a Percolation Rate 100 25 25 15 10 10 25 15 10 Slower than 60 Minutes per Inch Unlined or Partially Lined Evapotranspiration System, 100 (4)(2) 25 15 10 10 25 i 5 10 Wastewater Pond, or Surface 25 Disposal System Other than Aerosol Lined Sand Filter 60 (4)(2) 25 15 10 10 25 10 5 10 Lined Evapotranspiration (4)(2) 25 15 10 10 25 10 5 Field or Lined Wastewater 60 10 Pond _ Pit Privy or Vault Privy ' (4)(2) 50 10 25 15 10 10 25 10 -- Septic Tanks, Treatment — (2) (4)(2) (1) Plants, Dosing Tanks: Vaults 50 10 25 5 10 10 50 10 -- Budding Sewer or (2)(4) (4)(2) (4) {2)(4) (4) (2)(4) (2)(4) Effluent Lines 50 10 25 0 10 ICI 50 10 -- NOTE. The minimum distances shown above shall be main wined between the system components and the physical features described. Where soil, geological or other conditions warrant, greater distances may be required by the local board of health or by the Water Quality Control Commission pursuant to C.R.S. 25-8-206 in accordance with the authority prescribed by law and rules and regulations implemental of said section. Components which are not watertight should not extend into areas of the root system of nearby trees. For repair or upgrading of existing systems where the size of lot precludes adherence to these distances, repaired facility shall not be closer to water supply components than the existing facilities (1) I.listance shown shall not apply to treatment plants or effluent fines where recycling is permitted 60 0 15 30 50 120 ( IN FEET ) 1 inch = 30 ft. REMOVABLE PVC CAP INSTALL MARKER IF CAP IS TO BE BURIED, FINISH GRADE 4" COUPLING 4" SEWER LINE 4" x 4" x 4" PVC WYE 4" RISER — 4" 45' SWEEP BEND CLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N.T.S. FIELD JOINT REQUIRED FOR MODELS 2014-129 & 2014-160 ACCESS WAY VENT STRAIN RELIEF CORD CONNECTOR POWER 8t ALARM CABLE 12-6 W/GND 20T4 NO [BAFFLE WATER TIGHT LID, FRP DUAL WALL, CORRUGATED HDPE ACCESSWAY ELECTRICALAQUI (E DISCONNECT N INLET, GROMMET TO ACCEPT 4,50" 0.0, PVC PIPE (STANDARD). DUST COVER SUPPLIED FOR SHIPMENT (NOT SUITABLE FOR BURIAL) INTERNAL WELL VENT 2.0* DIA. CORE CONTROL COMPARTMENT BREATHER DISCHARGE 1 1/4" FPT (304 S.S.) QUICK DISCONNECT ASSY. (304 5.5.) S.S. CAST BALL VALVE 42.8in 1087rrrn OISCH ALARM 31.Sin 800mm 28.5in 1 1/4" DISCHARGE LINE . (304 5.5.) CHECK VALVE (GLASS FILLED PVC) ANTI -SIPHON VALVE (GLASS FILLED PVC) ON 724mm 106gol 401 L 20.5in 18.5in 521mm 420mm 74 gal 58 gal 280 L 220 L HDPE TANK 1/2' NOMINAL WALL THICKNESS 150 GALLON CAPACITY SEMI -POSITIVE DISPLACEMENT EACH DIRECTLY DRIVEN BY A CAPABLE OF DELIVERING 9 gpm (34 Ipm TYPE PUMP 1 HP MOTOR AT 138' T.D.H. AT 42m T.D.H,) BALLAST REQUIREMENTS A CONCRETE ANCHOR 15 RE UIRED ON ALL OUTDOOR MODEL 2014 A IONS SPECIFIC CONCRETE DIMENSIONS ARE REQUIRED TO ACHIEVE NECESSARY BALLAST EFFECT SEE INSTALLATION INSTRUCTIONS FOR FURTHER DETAILS SGS DR BY CAH 03/22/03 A 1/16 CIiK"O DATE ISSUE SCALE one SEWER SYSTEMS MODEL 2014, NO BAFFLE, DETAIL SHEET PAO910P02 WELL SETBACK GARFELD COUNTY) AEA OF F1FLUENCE PEA STATE GUIDELINES) PROPOSED FIELD: PROPOSED HOUSE). TOTAL AVERAGE DAILY FLOW = 1,050 GPD AREA OF INFLUENCE DESIGN FLOW 1,050 GPD * 1.5 = 1,575 GPD FOR FIRST 1,000 GPD: 100 FEET ADD 8 ADDITIONAL FEET FOR EACH 100 GALLONS PER DAY OF AREA OF INFLUENCE FLOW OVER 1,000 GALLONS 575 / 100 = 5.75 6 * 8 = 48 FEET 48 FEET + 100 FEET = 148 FEET (AREA OF INFLUENCE) STREAM SETBACK ODER GARFIELD COUNTY) PROPOSED FIELD: (PROPOSED HOUSE) TOTAL AVERAGE DAILY FLOW = 1,050 GPD AREA OF INFLUENCE DESIGN FLOW 1,050 GPD * 1,5 = 1,575 GPD FOR FIRST 1,000 GPD: 50 FEET ADD 8 ADDITIONAL FEET FOR EACH 100 GALLONS PER DAY OF AREA OF INFLUENCE FLOW OVER 1,000 GALLONS 575 / 100 = 5.75 6 * 8 = 48 FEET 48 FEET + 50 FEET = 98 FEET (AREA OF INFLUENCE) (2) Crossings: or encroachments niay be permitted at the points as noted above provided that the water conveyance pipe is encased for a minimum distance of ten (ID) feet on each siide of the crossing- A length of pipe shall he used with a minimum Schedule 40 rating of sufficient diameter to easily slide over and completely encase the water conveyance. Ridged end caps of at least Schedule 40 rating must be glued or secured in a watertight fashion to the ends of Me encasement pipe. A hole of sufficient size to accommodate the pipe shall be drilled in the lowermost section of the ridged cap so that the conveyance pipe rests on the bottom of the encasement pipe- The area in which the pipe passes through the endcaps shall be scaled with an approved underground sealant compatible with the piping used. Add 8 feet additional distance for each 100 gallons per day of design flow over 1000 gallons per day as specified in the table, unless it can be demonstrated by a registered Professional Engineer or Geologist that a mechanical or natural barrier will prevent enntamination. (3) (4) Encroachments may be permitted provided the water or wastewater conveyance pipe is encased as in (2) above, specified in the table. ggNERAL ABBOFFMON TRENCH NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2, THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. 3, DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA, 4. TRENCH LATERALS SHALL FOLLOW CONTOURS. 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7 NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED, 8. UNSUITABLE MATERIAL EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT—RUN MATERIAL. 9. IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIO—MAT. 10. BENDS IN TRENCH SHALL BE MADE WITH END PLATES AND 4"16 PVC OR MANUFACTURER'S PREFABRICATED BENDS. VICINITY MAP SCALE: 1"=3000' geteiALIIXIMI 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. TFIE EXISTING ISDS SYTEM WAS DESIGNED FOR A 7 BEDROOM HOUSE AND 5 HORSE STALL BARN. THE EXISTING 1505 SYTEM WAS ASBUILT 6-33-06 BY HIGH COUNTRY ENGINEERING AND ACCEPTED BY GARFIELD COUNTY. THE EXISTING HOUSE I S ONLY 5 BEDROOM AND THE 5—HORSE BARN WAS ELIMINATED PER CLIENT EMAIL DATED 4/28/06. THE REDUCTION IN THE EXISTING HOUSE ALLOWED FOR THE PROPOSED 2 BEDROOM POOLHOUSE TO TIE INTO THE EXISTING FIELD. 3. FLOW FOR EXISTING 5 BEDROOM HOUSE (5 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY) IS: 750 GPD = AVERAGE DAILY FLOW. FLOW FOR THE PROPOSED 2 BEDROOM POOLHOUSE (2 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY) IS: 300 GPO = AVERAGE DAILY FLOW. TOTAL DESIGN FLOW = 1,575 GPD SEPTIC TANK FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM: MINIMUM TOTAL TANK SIZE: * 1 DAY/24 HRS * 30 HRS = 1,969 GPD EXISTING ONE 2,000—GALLON COPELAND CONCRETE SEPTIC TANK IN SERIES WITH ONE 1000—GALLON COPELAND CONCRETE SEPTIC TANK WITHOUT BAFFLES. ***INSTALL EFFLUENT FILTER IN OUTLET*** STANDARD ABSORPTION AREA PER EACH SYSTEM: t=PERCOLATION RATE = 60 min./in. 5 INCREASE FIELD AREA BY 20,t TO ALLOW FOR GARBAGE GRINDERS: 2,439 SF * 1.2 = 2,928 SF 30% REDUCTION FOR USE OF STANDARD INFILTRATOR UNITS IN TRENCH CONFIGURATION 'YIELDS 2,050 SF 0 15.5 S.F./UN1T, 133 UNITS REQUIRED. EXISTING FIELD CONTAINS 164 UNITS. 4. WET WELL SIZING 300 GPO = AVERAGE DAILY FLOw. 450 GPO 4 DOS1NGS/DAY 15 113 GALLON WET WELL DUE TO THE POOLHOUSE DISCHARGE LINE DEPTH THE 4 FT DIAMETER WET WELL SHOULD HAVE A TOTAL STORAGE DEPTH OF 6 FT. TWO S10/4W PIRANHA GRINDER PUMPS SHOULD BE USED_ LINE FROM WETWELL TO SEPTIC TANK WILL MUST CONTAIN A BACKFLOW PREVENTER, 5. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 7, TOPSOIL COVER MAY BE VARIED (OATH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE—HALF FOOT OF FINAL GRADE. 9. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED, 10, PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 11. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR 10 BACKFILLING OF SYSTEM COMPONENTS. 12, SOIL AND PERCOLATION INFORMATION PROVIDED BY H.P. GEOTECH, INC., JOB NO, 103 377, DATED MARCH 25, 2004. 13, THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT, PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY, 14, THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY, BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 15, SITE PLAN INFORMATION PROVIDED BY CLIENT. 16, INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 6.0 FEET. 17, EXISTING 1505 FIELD LOCATION PER HIGH COUNTRY ENGINEERING SURVEY. 18. PROPOSED DOSING TANK AND 2—IN EFFLUENT LINE 10 BE SURVEYED PRIOR TO ACCEPTANCE. 19. TRACING WIRE TO BE INSTALLED %PATH 2—IN EFFWENT LINE. 20. EXISTING WELL PER CLIENT IS LOCATED APPROXIMATELY 20—FT NORTH OF EXISTING 5—BEDROOM HOUSE. o 0 AS-BUILT DRAWING co az 0 0 0 0 LLJ 0 PROJEC 202170