Loading...
HomeMy WebLinkAbout03920<:70 ().\~~ . • .. ,,," "°"""' '"'"''" •••• """"~" """"'"' \V' \.,\ JU:,-~ 109 8th Street Suite 303 ~ Glenwood Springs, Colorado 81601 C(,,f. Phone (303) 945-8212 PROPERTY Permit N~ 3920 Assessor's Parcel No. c::J / ?Cf-ofl-0¥-0-0/ This does not constitute a building or use permit. System Location __ ..:J~L...Ll..J.~.._~~-'-4-..L.::::t __ ~l)..~,,.,.~----,..---,.----=-----------­ L•gal Description of Assessor's Parcel No. --'kA""'--'---'{'-_,W,,,.,.,,....,A,,.,_4\....--.l~.>!..>•=:sL_=---":....::~~----------- SYSTEM DESIGN ______ Septic Tank Capacity (gallon) Other ______ Percolation Rate (minutes/inch) Number of Beliicooms (or other) ____ _ Required Absorption Area -See Attached ~ ~ Special Setback Requirements: Date _____________ Inspector ___________________________ _ FINAL SYSTEM INSPECTION ANO APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer ________________________________________ _ Septic Tank Capacity ______________________________________ _ Septic Tank Manufacturer or Trade Name Septic Tank Access within B" of surface -------------------------------- Absorption Area---------------------------------------- Absorption Area Type and/or Manufacturer or Trade Name-------------------------- Adequate compliance with County and State regulations/requirements _____________________ _ Other __ ~----------------------------------------- Date 1~f5-o£ Inspector~~ ~h V .J.a4-?..z. RETAIN WITH RECEIPT; CORDS AT CONSTRU;TION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973. Revised 1984. 2. This permit 1s valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters. or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine -6 months in jail or both). Whtte -APPLICANT Yellow -DEPARTMENT PERMIT REQUEST FOR (~EW INSTALLATION ( )ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respeet to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: NearwhatCityofTown 'S/L( SizeofLot I 1~ /II r rT · Legal Description or Address f'c}7' c,,e,;;,/c( '!?rk-r;(ll, ?/t,S?f WASTESTYPE: (4WELLING ( ) TRANSIENTUSE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER-DESCRIBE _______________ _ BUILDING OR SERVICE TYPE:_>.---'/ -o/__,'"""'h_,~~~..-pc't"J1:J~+1_14_,_·....,.,,,,___ ____ -=------- Number of Bedrooms NlJll(;er of Persons~.-<.__ __ _ (.-("Garbage Grinder (-1 Automatic Washer SOURCE AND TYPE OF WATER SUPPLY: (~WELL If supplied by Community Water, give name of supplier: ( -1'0ishwasher ( ) SPRING ( ) STREAM OR CREEK DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:-==---------- Was an effort made to connect to the Community System? /Vp --------------- A site plan is required to be submitted that indicates the followin& MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SUE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table-=t'M~AMA~'""l2~'t/,..,W~-----------------­ PercentGround Slope~?'----....S:+--Li~S'---------------------- • TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( ~ SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER-DESCRIBE FINAL DISPOSAL BY: c-1 ABSORPTION TRENCH, BED OR PIT ( ) EV APOTRANSPIRA TION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER-DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? ;JO ---- PERCOLATION TEST RES UL TS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) (5'&£ /2'e{):IRfJ Minutes ____ _,,er inch in hole No. 1 Minutes _____ _,,er inch in hole No. 3 Minutes er inch in hole No. 2 Minutes per inch in hole No._ Name, address and telephone ofRPE who made soil absorption tests: ._16"-~'--"'6""'~----...;.'ff-.:...-______ _ Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, infonnation and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Sign:~ Dat~a! /Z~3 PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!! c:~d>tech HEPWORTH-PAWLAK GEOTECHNICAL November 7, 2003 Norm Clasen P.O. Box 1155 Basalt, Colorado 81621 ! ll' I 1 1 ' ' ' ' ' "~' '. :-! ._ ,, --..... ~ -• ...:, : ... Job No. 103 694 Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed Residence, Lot 1, Cedar Hills Subdivision, Garfield County, Colorado. Dear Mr. Clasen: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering services to you dated October 27, 2003. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Proposed Construction: The proposed residence will be a 11-l story wood frame structure over a full basement level located on the site as shown on Figure l. The attached garage and basement floors will be slab-on-grade. Cut depths are expected to range between about 3 to 8 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction. The septic disposal system is proposed to be located about 100 feet to the south-southwest of the residence. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: The site is pastureland that was vacant at the time of our field exploration. There is an existing barn, riding arena and corral to the northwest of the proposed building area. The ground surface in the building area is relatively flat with a slight slope down to the southeast and southwest. An irrigation ditch is located to the east of the building area. Vegetation consists of grass. Norm Clasen November 7, 2003 Page 2 Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating two exploratory pits in the building area and one profile pit in the septic disposal area at the approximate locations shown on Figure 1. The logs of the pits are presented on Figure 2. The subsoils encountered, below a minor amount of organics, consist of medium dense, sand and silt to the excavated depths of 8 1h to 101h feet. Results of swell-consolidation testing performed on relatively undisturbed samples of the silt and sand, presented on Figures 3 and 4, indicate low compressibility under existing moisture conditions and light loading and a low collapse potential (settlement under constant load) when wetted. The samples showed moderate to high compressibility upon increased loading after wetting. The laboratory test results are summarized in Table 1. No free water was observed in the pits at the time of excavation and the soils were slightly moist. Foundation Recommendations: Considering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1,200 psf for support of the proposed residence. The soils tend to compress after wetting and there could be some post-construction foundation settlement. The amount of settlement would depend on the depth and extent of subsurface wetting and could be on the order of 1 to 2 inches. Precautions should be taken to prevent wetting of the bearing soils. Footings should be a minimum width of 20 inches for continuous walls and 2 feet for columns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils. The exposed subgrade should be moistened and compacted prior to forming footings and placing concrete. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 36 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the on-site soil as backfill. Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab-on-grade construction. The soils are compressible when wetted. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical Job #103 694 Ge':!Aect I Norm Clasen November 7, 2003 Page 3 movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free-draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with Jess than 50 3 passing the No. 4 sieve and less than 2 3 passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95 3 of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on-site soils devoid of vegetation, topsoil and oversized rock. Underdrain System: Although free water was not encountered during our exploration, it has been our experience in the area that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below-grade construction, such as retaining walls and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free-draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1 3 to a suitable gravity outlet. Free-draining granular material used in the underdrain system should contain Jess than 2 3 passing the No. 200 sieve, less than 503 passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 1 \n feet deep. An impervious membrane such as 20 mil PVC should be placed beneath the drain gravel in a trough shape and attached to the foundation wall with mastic to prevent wetting of the bearing soils. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be 2) Job #103 694 avoided during construction. Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95 3 of the maximum standard Proctor density in pavement and slab areas and to at least 903 of the maximum standard Proctor density in landscape areas. Free-draining wall backfill should be Norm Clasen November 7, 2003 Page 4 capped with about 2 feet of the on-site, finer graded soils to reduce surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 6 inches in the first IO feet in unpaved areas and a minimum slope of 3 inches in the first IO feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Irrigation sprinkler heads and landscaping which requires regular heavy irrigation, such as sod, should be located at least 5 feet from foundation walls. Percolation Testing: Percolation tests were conducted on November 4, 2003 to evaluate the feasibility of an infiltration septic disposal system at the site. One profile pit and three percolation holes were dug at the locations shown on Figure 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pit shown on Figure 2 and consist of sand and silt to the excavated depth of 81h feet. The percolation test results are presented in Table 2. The percolation test results indicate an infiltration rate between 7 and 13 minutes per inch with an average of 9 minutes per inch. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for a conventional infiltration septic disposal system. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Figure 1, the proposed type of construction and our experience in the area. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. Job #103 694 Ge'Jitect I Norm Clasen November 7, 2003 Page 5 We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Sincerely, Iordy Z. Adamson, Jr , P Reviewed by: Steven L. Pawlak, P.E. JZNksw attachments Figure 1 -Location of Exploratory Pits and Percolation Test Holes Figure 2 -Logs of Exploratory Pits Figures 3 and 4 -Swell Consolidation Test Results Table l -Summary of Laboratory Test Results Table 2 -Percolation Test Results cc: High Country Engineering -Attn: Roger Neal Job #103 694 r.----r--~~-----==~=-:---~~--_J ;------------) PROPERTY BOUNDARY WATER WELL * I EXISTING I I RIDING I I ARENA I i'-) l',, r-=,---r---~ ( .-"', _ - - --:; - -~ -/EXISTING I ~~~~~~I '" -- -NG 0R1\JEVI~ I BARN I I I ~ , .._ 1::~1sil -_____ ~ -} __ _j ) I ---I ,/"' I I L ___ ,.."' \ \ PROPOSED \ \ ~ PROPOSED GARAGE \ DRIVEWAY I P 3 I I t:,, I I A I I P 1 PROPOSED RESIDENCE LOT 1 POND I I ~b..'-'P2 I I I I I I I I I I I I • PROFILE PIT ···-----... ~.:.IT 1 ----···---·· ./ / I I I ~---···~ I I \\ IRRIGA T!ON \ I I DITCH (DRY) I I 1 I \ I I I I ---EXI~ I I I "'\ I <S I "' ' I .... , z' I c;i I \ ~ \ I ES I I I I \ I I \ I \ * WELL EXISTING WELL ~ ~ UTILITY I \ \ EASEMENT ~ (TYPICAL) \ IRRIGATION DITCH --------I 7 ------I /' I /, APPROXIMATE SCALE 1" = 60' z > ) I 103 694 HEPWORTH-PAWLAK GEOTECHNICAL, INC. LOCATION OF EXPLORATORY PITS AND PERCOLATION TEST HOLES Figure 1 -.. .. ..._ .r:; -Q. .. 0 PIT 1 PIT 2 PROFILE PIT 0 0 WC•4.4 00•89 5 -200•42 5 WC-6.7 00•96 WC-7.2 -200-24 10 10 00•98 -20<>-34 15 15 LEGEND: ~ SAND AND SILT (SM-ML); medium dense, slightly moist, light brown, slightly porous. ~ 2" Diameter hand driven liner sample. NOTES: 1. Exploratory pits were excavated on November 3, 2003 with o Cose 580 backhoe. 2. The exploratory pits were located approximately from features shown on the site pion provided. 3. Elevations of exploratory pits were not measured and logs of exploratory pits ore drown to depth. 4. The exploratory pit locations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. No free water was encountered in the pits at the time of excavating. Fluctuations in water level may occur with time. 7. Laboratory Testing Results: WC = Water Content ( 3 ) DO = Ory Density ( pcf ) -200 = Percent passing No. 200 sieve 103 694 HEPWORTH-PAWLAK GEOTECHNICAL, INC. LOGS OF EXPLORATORY PITS Figure 2 -.. .. ..._ .r:; -Q. .. 0 . . Moisture Content = 4.4 percent 0 Ory Density = 89 pcf -r-- Sample of: Very Silty Sand -From: Pit 1 at 3 Feet .... .... i-.~ 1 --..... .... ~ 2 ... , '\ Compression c upon 0 3 wetting o; "' \ .. ... Q. E 4 \ 0 (.) \ 5 \ 6 \ 7 0.1 1.0 10 100 APPLIED PRESSURE -ksf Moisture Content = 7.2 percent 0 Dry Density = 98 pcf Sample of: Silty Sand ~} From: Pit 1 at 9 Feet 1 (""---1--.... ~ ' ....... 2 c "" Compression 0 o; upon "' 3 \ wetting "' ... \ Q. E 0 (.) 4 \ 5 \ \ D 6 0.1 1.0 10 100 APPLIED PRESSURE -ks! 103 694 HEPWORTH-PAWLAK SWELL CONSOLIDATION TEST RESULTS Figure 3 GEO TECHNICAL, INC. . Moisture Content = 6. 7 percent Dry Density = 96 pcf Sample of: Silty Sand From: Pit 2 at 8 Feet 0 r--r-r... i-.~ 1 Compression upon 2 ~ wetting 3 ~ \ 4 c: \ 0 ·;;; "' ., ~ a. 5 E \ 0 () 6 7 \ \ 8 \ ' 9 0.1 1.0 10 100 APPLIED PRESSURE -ksf 103 694 HEPWORTH-PAWLAK SWELL CONSOLIDATION TEST RESULTS Figure 4 GEOTECHNICAL, INC. HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 JOB NO. 103 69·1 SUMMARY OF LABORATORY TEST RE SUL TS !;.AMl'I f l OCA 1 IUN NATURAL NATURAi_ GRADATION PERCENT ATTERBERG LIMITS UNCONFINED Pll Pf PHI MOISTURf ORV GRAVEL SAND PASSING llOUID PLASTIC COMPRESSIVE SOil OR (hwO CONlENT DENSITY (%) 1•,1.1 NO. 200 LIMll INDEX SlRENGTll l:itUROCK 1 YPl: l"•I 1111.11 SIEVE l~•l t"•I lPSF) 1 3 4.4 89 42 very silty sand 9 7.2 98 34 silty sand 2 8 6.7 96 24 silty sand II 11 11 11 11 I --· HEPWORTH-PAWLAK GEOTECHNICAL, INC . . - TABLE 2 PERCOLATION TEST RES UL TS JOB NO. 103 694 HOLE NO. HOLE DEPTH LENGTH OF WATER DEPTH WATER DEPTH DROP JN AVERAGE llNCHESI INTERVAL AT START OF AT END OF WATER PERCOLATION (MINI INTERVAL INTERVAL LEVEL RATE llNCHESI (INCHES) (INCHES) !MIN./INCH) P-1 63 10 10 8 2 water added 14 3/4 12 1 /2 2 1/4 12 1/2 10 3/4 1 3/4 10 3/4 9 1/4 1 1/2 9 1/4 8 1 1/4 8 6 3/4 1 1/4 6 3/4 5 1/2 1 1/4 5 1/2 4 1/4 1 1/4 8 P-2 75 10 10 1 /2 9 1 1/2 9 8 1/2 1 /2 8 1/2 7 3/4 3/4 water added 11 1 /2 10 1/4 1 1 /4 10 1/4 9 1/2 314 9 1/2 8 3/4 3/4 I 8 3/4 8 3/4 8 7 1/4 314 13 P-3 62 10 11 114 9 2 1/4 I I 9 7 1 /4 1 314 !1 water added 14 114 12 1/4 2 II 12 1/4 10 1/2 1 3/4 11 10 1/2 8 3/4 1 3/4 8 3/4 7 114 1 1 /2 I I 7 114 5 3/4 1 1/2 I 5 3/4 4 1/4 1 1 /2 7 II Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on November 3, 2003. Percolation tests were conducted on November 4, 2003. The average percolation rates were based on the last two readings of each test. VICINITY MAP SCALE: 1"=2DDO' QQERALNQ! 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY REGULATIONS Of INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 4 BEDROOMS • 2 PERSONS/BEDROOM • 75 GALLONS/PERSON/DAY IS: 600 GPO = AVERAGE DAILY FLOW. DESIGN FLOW= 1 .5 • AVERAGE = 900 GPO (Q) SEPTIC TANK: MINIMUM TOTAL TANK SIZE: Q • 1 DAY/24 HRS • 30 HRS= 1125 GPO INSTALL ONE 1250-GALLON TANK WITH BAFFLE •••INSTALL EFFLUENT FILTER IN SEPTIC TANK OUTLET••• STANDARD ABSORPTION AREA: >- ID z 0 iii 5 w 0:: w f-- <( a ci z a 0:: a tli w a (j z - a 0:: a 0:: a d .., I") ~ Vl z .... a a " Vl 0:: w w f-- :,,: <( ..J u a G: g ~ ~~ L 2• MIN. COVERR !6" MAX. COVE ECTION (TYP .) REMOVABLE CAP 1----36" ----1 INSPECTION WELL DETAIL N.T.S. ' I "' "' I "' I " x I x )( ~ I \~ I """ I "" I I N 88"53'17" W 267.91' !~--/ I \ I "" I I "" / I "" '--I x x x I I I I x // x /\ I I x~+/F z I ~ x ~~ N " (1) \ • ~ /IRRIGATION DITCH '-,.. . ( ......... \"-/) 9---~ ~ _) '\- \ LOT 1 \ l NA TUR SIDES & RJlGH.E~ CRO~ ,, . 4. 5. 6. 7. 8. ~LC.'""l'll VUI.;) M.l"\C. l"\C.\JUl"C.l.J 1"11 1"\LL OC.l'llV.:) P,l'IU '"'' LC.,....;:11 C.Yt.n.J IVV FEET ALONG THE HOUSE SEWER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE, LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. SOILS INFORMATION PROVIDED BY H.P. GEOTECH, INC,, JOB NO, 103 694, DATED NOVEMBER 7, 2003. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM OWNER. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. DESIGN OF ABSORPTION BED BASED ON PERC. RATE AND SOIL PROFILE INDICATING A POROUS SAND AND SILT SOIL TYPE. 16. ALL THE NECESSARY SETBACKS ARE MET FROM THE WELLS (100 FEET). , 7. , . 2. 3. 4. 5. 6. 7. AN IRRIGATION DITCH EXISTS ALONG THE CENTER OF THE PROPERTY, HOWEVER IT IS LOCATED BEYOND THE 50 FOOT SEPARATION REQUIREMENT FOR AN ABSORPTION TRENCH. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND BED, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. TRENCH LATERALS SHALL FOLLOW CONTOURS. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOt.t.4ENDATIONS. BED BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 8. BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT-RUN MATERIAL. ..... PROJECT NO. 2031717.0218 , I ...___ ----- -o "" \ .............. ~l~~/ I . \ GATE l I \ I \ \ \ \ l 10 \ i FRf:'A -tTION ----/ ·/ \ I I 1 -- 10'± GRAVEL ~-1 ROAD// -........... I 4•13 SCHEDU SEWEI _,,.... ) GRAPHIC SCALE lO 0 15 lO "° 120 ~-... --I I I I ( IN FEET ) I Inch = 30 ft. NOTICE: ACCORDING TO COLORADO LAW YOU lil.JST CC».MfNC$' ANY I r:'f".&.t - 5' (MIN.) SCHEDULE 40 PVC A VITY SEWER LINE 2% SLOPE - 'C / --- 15.o'Ai'T11 E~SEMEN NATURAL 8 INFILTRATOR UNIT (TYP.) \ I I ~UTILITY EASMENT . 12" MIN. COVER 36" MAX. COVER \ \ \ 4" COUPLING 4" SEWER LINE 4" x 4" x 4" PVC WYf. \ \ \ " \ \ \ \ L 4" RISER 4" 45" SWEEP BEi ~'mo ASSEMBL" 'I=" WI=" R ('I I=" .ti.l\I ()I I T 111=" T .ti.I I