GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT
108 Eighth Street, Suite 201
Glenwood Springs, Coloradof 81601
Phone (970) 945-8212
INDIVIDUAL SEWAGE DISPOSAL PERMIT
PROPERTY
Permit 4 U 5 9
Assessor's Parcel No.
kq 7,1p,.7.CO0VI
This does not constitute
a building or use permit.
Owner's Name •(4LL X Atk.,. Present Address L[% l &kk �r - 44J1� Phoneqf>f i
System Location
i 1�10,411:A !V '8) PAW'.
Legal Description of Assessor's Parcel No 1 r��- t'X- 12...ae,c ir,
SYSTEM DESIGN
Septic Tank Capacity (gallon) _ . _Other eQ
Percolation Rate (minutes/inch) Number of Bedrooms (or other) �- L
Required Absorption Area - See Attached
Special Setback Requirements:
Date. Inspector
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System installer 4 4///,47:P //r/5 Z /G%� . r�(�. :1"-)05/641 / ,
Septic Tank Capacity /VC; A///41( /�/C,! o•L� SCSI--�%�%/ /7
Septic Tank Manufacturer or Trade Name
Septic Tank Access within 6" of surface
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name
Adequate compliance with County and State regulations/requirements_ _
Other
Date __ Inspector
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs. alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I. Petty Offense ($500.00 fine — 6
months in jail or both).
White - APPLICANT Yellow - DEPARTMENT
Garfield County -1SDS Application Page 3 of 15
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
tac
OWNER ADDRESS 23 OZS DevexeulvJil 5 "✓'ts 0 2
PHONE 0 1-1-5-75:_;‘
CONTRACTOR ADDRESS 61, -)'‘AC) -"--
PHONE
PERMIT REQUEST FOR: (NEW INSTALLATION () ALTERATION () REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography
of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in
test holes (See page 4)
LOCATION OF PROPOSED FACILITY: f �
Near what City or Town I , r t ICA iV a r44 OL CA—
Size
of Lot 1 aet.e.4.
Legal Description or Address
WASTES TYPE:
welling
(} Transient Use
(51,_W € Cc4t6ee c
(} Non -Domestic Wastes
(} Commercial Or Industrial
() Other: Describe:
BUILDING OR SERVICE TYPE:
Number of Bedrooms 3
Number of Persons c_J
hhttp://www.garficld-county. comlhotnc/index. asp?page=689
11/4/2004
Garfield County -,ISDS Application Page 4 of 15
() Garbage Grinder
(Automatic Washer () Dishwasher
SOURCE AND TYPE OE WATER SUPPLY:
() SPRING () STREAM OR CREEK
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System? () Yes ( ) No
ihttp://www.garfield-county.coinlhornefindex.asp?page=689 11/4/2004
• Garfield County -,TSDS Application Page 5 or 15
A site plan is required to be submitted that indicates the following MINIMUM
distances:
Leach Field to Well: G �. cam• "S4 r ay c k e u
Septic Tank to Well:
100 feet
50 feet
Leach Field to Irrigation Ditches, Stream or
Water Course 50 feet
Septic System to Property Lines:
10
feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A
SITE PLAN.
GROUND CONDITIONS:
Depth to first Ground Water:
Table Percent Ground Slope:
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOS D:
(/Septic Tank () Aeration Plant () Vault
( ) Vault Privy () Composting Toilet ( )Recycling/ Potable Use
() Pit Privy () Incineration Toilet () Recyclingl0ther Use
http://www.garfield-county.comlhome/index.asp?page=689 11/4/2004
Garfield County - ISDN Application Page 6 of 15
() Chemical Toilet ( ) Other — describe:
FINAL DISPOSAL BY:
(;'Absorption Trench, Bed Or Pit () Evapotranspiration
() Underground Dispersal () Sand Filter
() Above Ground Dispersal () Wastewater Pond
() Other — Describe:
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? Ai°
PERCOLATION TEST RESULTS: (To he completed by Registered Professional Engineer, if the
Engineer does the Percolation Test)
Minutes_ 6. per inch in hole No. 1
Minutes 'j. 2 per inch in hole No. 3
Minutes I i per inch in hote No. 2 Minutes per inch in hole No. 4
http://www.garficld-county.cornlhorne/indcx.asp?page=689 11/4/2004
Garfield County -,[SDS Application Page 7 of 15
RPE__WHO MADE_SOIL ABSORPTION TESTS: 1
Name: jiAx.,0401 i cs n[ cvn.QM[p L
Address: tUC� �� C,�,����•�.f� �,, [� 1n w�C� J���'r�
Telephone: C70 — 9c6- s7 DCS
RIDE RESPONSIBLE FOR DESIGN OF THE SYSTEM:
Name: r t.itTTn v+cstj & Z k V'QL
Address: C3� � 3•i[ ,�£�. + E ,3,-1,..AceN � 1
Telephone:
q10 qv —5160
Applicant acknowledges that the completeness of the application is conditional upon such further
mandatory and additional tests and reports as may be required by the local health department to be
made and furnished by the applicant or by the local health department for purposed of the evaluation
of the application; and the issuance of the permit is subject to such terms and conditions as deemed
necessary to insure compliance with rules and regulations made, information and reports submitted
herewith and required to be submitted by the applicant are or will be represented to be true and
correct to the best of my knowledge and belief and are designed to be relied on by the local
department of health in evaluating the same for purposes of issuing the permit applied far herein. I
further understand that any falsification or misrepresentation may result in the denial of the
application or revocation of any permit granted based upon said application and in legal action for
perjury as provided by law.
Signed:
Date: II f 1$ ivH
http://www,garfield-county.com/home/index.asp?page-689 11/4/2004
Zancanella and Associates
1005 Cooper Avenue
Glenwood Springs, Co 81601
(970) 945-5700
Fax (970) 945-1253
Percolation Test Results
Client: Gerald Burk
2303 Devereux Road
Glenwood Springs, CO 81601
Joh No. 24229
Location: West Elk Ranch
Parcel 15, Section 12
T4S, R92W of the 6th P.M.
New Castle, CO 81647
Water Level Drop Time Percolation Rate
Test Hole (inches) (minutes) (minutethnclr)
1
2
3
5 33 6.6
3 33 11
3.75 33 8.8
9
Average
Soil Profile Hole: 8 -foot deep hole consisting of loam soil from a depth of to 20 inches and 3 -inch sandstone
cobbles from a depth of 20 inches to a depth of 8 feet.
Test Run: September 25, 2004.
Zafcancila Associates
S[)S, 11/3/2004
Z:124O(}U124229 Burk, Gerald\Pcrcolation Test Results
P RI SED CA3IN
AND ISDS
GENERAL NOTES
INSPECTION WELL (TYP,)
PROD❑SED WELL
>50' FROM SEPTIC TAN<
>130' FRI,Y LEACH FIELD
Tri
RIDGEVIEV LN.
NOR �yRI
DGS
DARCLL 1 5
SCALE: 1" = 300'
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY
AND COLORADO DEPARTMENT OF HEALTH (CDOH) REGULATIONS OF INDIVIDUAL
SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT
SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN
THE ABOVE—MENTIONED REGULATIONS.
2 DESIGN FLOW = 2 PERSONS/BEDROOM*75 GAL*1.5*3
SEPTIC TANK: MINIMUM PRE—CAST CONCRETE TANK
CDOH REGULATIONS IS 1,000 GALLONS.
V = 30 HR* 675 GAL = 844 GAL
24 HR
RECOMMEND ONE 1000 GAL TANK.
FIELD SIZE: PER CDOH EQUATIONS:
A=
A =
Q -r[
5
67547
5 = 405 SQ. FT.
BEDROOMS = 675 GPD
SIZE ACCORDING TO
Q = DESIGN FLOW
t = PERCOLATION RATE = 9 MINUTES PER INCH
PER CDOH MINIMUM REQUIREMENTS FOR USE OF "INFILTRATOR" SYSTEMS
AREA REDUCTION = (0.5)*A
AREA REQUIRED = 0.5*405 = 203 SQ.FT.
® 15.5 5Q. FT. PER UNIT = 14 UNITS
RECOMMEND 16 INFILTRATOR UNITS.
3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY 15
PRESENT.
4. VEHICULAR TRAFFIC 15 PROHIBITED ON THE FIELD.
5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100
FEET ALONG THE HOUSE SEWER.
6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN 1/2—FOOT OF FINAL GRADE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM AREA
USING DRAINAGE SWALES AS NECESSARY.
9 . Ptl-' CULA I I UN NAIL UA LL] UN PU ' ULA 1 I UN I t5 I FLKI- U rMED BY
ZANCANELLA & ASSOCIATES, INC. ON SEPTEMBER 25, 2004.
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT
MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
11. THIS SYSTEM 15 SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR
FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR
FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
GENERAL ABSORPTION TRENCH NOTES
1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET.
2. THE BOTTOM OF EACH TRENCH SHALL BE LEVEL.
3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES,
AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING
ABSORPTION AREA.
4. TRENCHES SHALL FOLLOW CONTOURS.
5. INSTALL €NFHLTRATOR UNITS IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS.
REMOVABLE PVC CAP
MARK IF BURIED
FINISH GRADE
4" COUPLING
4" SEWER LINE
SEPTIC TANK
4" RISER
U I
PRECAST CONCRETE
DISTRIBUTI❑N BOX
CLEAN OUT
4" 45' SWEEP BEND
4" x 4" x 4"
PVC WYE
CLEAN OUT
ASSEMBLY
SLWECL
-A\ OUT
DETAIL
N.T.S.
ID
10'
PE !'K
I0'
a
0
20' MIN.
CABIN
DECK
DECK
OPOSED I ;=ice ='LA
NATURAL BACKFILL
12" MIN. COVER
NATURAL GROUND
TEEN
36"
CH CROSS SECT
/A
ON
N.T.S.
\\/
INFILTRATOR
INFILTRATOR UNIT (TYP)
t
1t
INFILTRATOR UNIT
TRENCH BOTTOM LEVEL
AND ROUGHENED
(TY.)
4" 0
SOLID PIPE
a
VICINITY
SCALE: 1"
PARCEL 15, SECTION 12, T.4S.,
v
An
= 2000'
R.92W. OF 6TH P.M.
INSTALL SPRINKLER
BOX COVER AT GRADE
<//\
CUT HOLE IN TOP OF INFILTRATOR UNIT
FOR INSTALLATION OF INSPECTION WELL
PIPE
COUPLING
4" 0 PERFORATED PIPE
SOLID CAP FOR SUPPORT ON
BOTTOM OF TRENCH OR BED
INSPECTION WELL DETAIL
N.T.S.
EX1S11NG GROUND
SURFACE
20" I --ER---- LOAM SOIL
0 0 0❑ ❑
0
0
0
0 0 0
D 0
0 0 D (21.0-3" SANDSTONE COBBLES
0
o 0 ❑
0 0
D 0
D D D
,p 0 0
0 0
0 0 0 0 0
NO GROUND WATER OBSERVED
SOIL PROFILE DETAIL
SCALE 1" = 4'
Nd
DATE
REVISION
MBADE
CBYD
APPO
BY
3ur<
Fam ily Cabin
SDS Desran Pan
Gerald 3ur<
SHEET NO.
SCALE:
1" = 10'
DATE:
November 4, 2004
SHEET:
1 OF 1
/ ZANCANELLA AND ASSOC/A TES, INC.
DRAWN BY:
SDS
CHKD BY:
SDS
APPD BY:
TAZ
DRAWING:
ISDS Design Pion
ENGINEERING CONSUL TANTS
POST OFFICE BOX 1908 - 1005 COOPER AVENUE
GLENWOOD SPRINGS. COLORADO 81602 (970) 945-5700
PROJECT: 24229