GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT
108 Eighth Street, Suite 201
wood Springs, Coloradof 81601
Phone (970) 9454212
INDIVIDUAL SEWAGE DISPOSAL PERMIT
PROPERTY
Owner's Name ' ` �/�7,, (� G q
System Location C��� 0_12_ 'k clai J/cL_ -t�t J I9
Legal Description of Assessor's Parcel No t`+-' 1 -
Permit
4048
Assessor's Parcel No.
This does not constitute
a building or use permit.
tcW9( �-q�t1`ier!i)Cki ��o Present Address-?31.C3A aCILT)7Gl�✓Phone CkS3 b.
SYSTEM DESIGN
Septic Tank Capacity (gallon) Other
Percolation Rate (minutes/inch) Number of Bedrooms (or other)
Required Absorption Area - See Attached
Special Setback Requirements:
Date Inspector
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System Installer
Septic Tank Capacity
Septic Tank Manufacturer or Trade Name
Septic Tank Access within 8" of surface
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name
Adequate compliance with County and State regulations/requirements
Other
Date — 0 Inspector
tf
TH RECEIPT RECORDS AT
NSTRUarON SITE
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs,alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine —6
months in jail or both).
OWNER
ADDRESS
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
�1�1 lr�J
AO
S ta
34ic r'Ca,i��Cce
PHONE G%(--3 _c?/(/
CONTRACTOR (nk fj 11 Ca,.v5C
ADDRESS Q,() 3ccoL >Fe 20 &L) S PHONE (it/ g-3 j -14
PERMIT REQUEST FOR (✓) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable
building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILLITY:
C
Near what City of Town a-SOribwb lkL % Size of Lot 2 Ac
Legal Description or Address Loy 4 Peje.- Q & f f K F S'T'S}' ['n ,z 6a,
WASTES TYPE: (DWELLING Cc/ Lk 3 C dt t 1 C da le( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES
( ) OTHER—DESCRIBE
BUILDING OR SERVICE TYPE: S/ 1 W2,1I, t j
Number of Bedrooms 4
Number of Persons
7
( ) Garbage Grinder (/) Automatic Washer (Dishwasher
SOURCE AND TYPE OF WATER SUPPLY: (fr{WELL ( ) SPRING
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
( ) STREAM OR CREEK
Was an effort made to connect to the Community System? Ai
A site • lan is re s uired to be submitted that indicates the followin MINIMUM distances:
Leach Field to Well:
Septic Tank to Well:
Leach Field to Irrigation Ditches, Stream or Water Course:
Septic System (septic tank & disposal field) to Property Lines:
100 feet
50 feet
50 feet
10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT
A SITE PLAN.
GROUND CONDITIONS:
Depth to first Ground Water Table
Percent Ground Slope
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
( ) SEPTIC TANK ( ) AERATION PLANT ( ) VAULT
( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE
( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE
( ) CHEMICAL TOILET( ) OTHER -DESCRIBE
FINAL DISPOSAL BY:
( ) ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION
( ) UNDERGROUND DISPERSAL ( ) SAND FILTER
( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND
( ) OTHER -DESCRIBE
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE?
PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the
Percolation Test)
Minutes per inch in hole No. 1 Minutes per inch in hole No. 3
Minutes per inch in hole No. 2 Minutes per inch in hole No. _
Namgg, address and telephone of .�PrE who made soil absorption tests:
A(1 ,%dice6ePfirro. LW (( G. S (m Y(bo&.
Name, address and telephone of RPE responsible for design of the system:
�( Secv;ct, Se ric P•o. . ) W G S g160
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the applicant
or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is
subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made,
information and reports submitted herewith and required to be submitted by the applicant are or will be represented to
be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of
health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any
falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based
upon said application and in legal action for perjury as provided by law.
Signed1t S( Date * 3 / ( /p5 —
PLEASE RAW AN ACCURATE MAP TO YOUR PROPERTY!!
VN
ca
• o
o
0
3
A›�
N U 'C
0. 2 ..c0)
p 0 O vOi
U d U col
H aS C)
Ct ▪ bOC.9
• ? Q
O
d 0 0 'u
U
o U 9 T U
0
4-4
b y O
• CA N
cnO • Li)
0 0
o�;tg
.Ni
s .O U
2,Ui
rioti 0 O
.-y
0
4)
CIO3
N U
o
County Road (Note the Road Number and Name)
3
ALL
PO Box 2844
lipPh
waadSpdns [081802
Ph 970-618-5033
Fax 303-216-2796
March 11, 2005
Michael Miemicki
950 Cowan Drive
Carbondale, Colorado 81623
Project No. 1058
Subsurface Investigation and Onsite Wastewater System Design, Miemicki Residence
Lot 4, Prince Creek Estates
Garfield County, Colorado
Mr. Miemicki,
ALL SERVICE septic, LLC performed a percolation test and an onsite wastewater system (OWS)
design for the subject residence. The property is located in Garfield County, in an area where OWS
and wells are necessary.
SITE CONDITIONS
A 5 -bedroom residence is proposed at the subject property. There is an irrigation ditch located to the
west of the residence, and the well is located to the east, as indicated on Figure 1. There are no other
wells within 100' of proposed drain field.
SUBSURFACE
The subsurface was investigated by excavating an 8 -foot test pit near the proposed drain field location as
shown on Figure 1. The test pit indicated the site has a 1 -foot sandy loam root zone, underlain by
gravelly, clayey sand to the maximum depth explored of 8 feet. Groundwater or bedrock was not
encountered.
DESIGN SPECIFICATIONS
The OWS design is based on 5 -bedrooms, and an average sewage load of 750 gallons per day (GPD).
The installation must include a 1500 -gallon, two-compartment, precast concrete septic tank. An
effluent filter is recommended. Gravelless trenches must be installed as indicated on Figures 1 and 2.
Three rows of 11 chambers, for a total of 33 chambers, and 511.5 square feet (SF) of infiltrative area,
are required. Construction must be according to the county ISDS regulations, the septic permit
provided by Garfield County Environmental Health Department, and this design.
Subsurface Investigation and OWS Design
Project No. 1058
March 11, 2005
Page 2
OPERATION INFORMATION AND MAINTENANCE
The surface of the drain field should be seeded upon completion. Vegetation is an important factor in
drain field performance. Geo -fabrics or plastics should not be used over the drain field. Livestock
should not graze on the drain field.
The homeowner should pump the septic tank every two years and clean the effluent filter as needed.
Garbage disposal use should be minimized, and non -biodegradable materials should not be placed
into the OWS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWS. No hazardous wastes should be directed into the OWS.
Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic
waste only.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC, and the county must view the OWS during construction. The OWS
observation should be performed before backfill, after placement of chambers and distribution pipes.
Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must
also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the
installation
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from
conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction
must be according to the county regulations. Requirements not specified in this report must follow
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working.
Please call with questions.
ALL SERVICE septic, LLC
Timothy R. Petz
3 copies
SITE PLAN, LOCATION OF PERCOLATION HOLES, dk
AND OWS DESIGN
TRENCHES = 3
CHAMBERS PER TRENCH = II
TOTAL NUMBER OF CHAMBERS = 33
(ELEV !PPROX 991')
SCALE
I"=50'
NORTH
OBSERVATION PIPES
CUT TO GRADE AND
PLACED IN 8" ROUND
SPRIKLER BOX
DISTRIBUTION_
BOX
(ELEV
APPR(
992'))
1500 -GALLON,
TWO-COMPARTMENT PRECAST
CONCRETE SEPTIC TANK. AN
EFFLUENT FILTER IS
RECOMMENDED.
ELEVATION OF TOP OF TANK
TO BE APPROXIMATELY •• '
AS SHOWN ON PLANS /
NOTES:
-SEPTIC TANK MAY BE RELOCATED TO
ACCOMODATE STUB -OUT. PUMPING OF TANK SHOULD
BE CONSIDERED TO ACCOMODATE PUMPING.
-IF 'QUICK-A(TM) CHAMBERS ARE USED ALL
SERVICE SEPTIC, LLC SHOULD BE CONTACTED TO
PROVIDE DETAILS.
THE LOCATION OF EXISTING AND PROPOSED
IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A
PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE.
IT 18 THE HOMEOWNERS DUTY TO ENSURE ALL
CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE
ACCURATE. ALL SETBACK DISTANCES SHOULD BE
CONFIRMED PRIOR TO EXCAVATION
LOT 4, PRINCE CREEK ESTATES
GARFIELD COUNTY, COLORADO
PROJECT NO. 1058
ALL
SERVICE SEPTIC, LLC
970-618-5033
FIGURE I
DESIGN
5 -BEDROOM RESIDENCE
LOADING • q - 750 GALLONS PER DAY
PERCOLATION RATE -18 MINUTES PER INCH (MPI)
CALCULATED AREA - ((1.5 X q) X egrt 18) / 5 - 955 SF
AREA REQUIRED - 955 SF
REDUCTION OF 50% USING CHAMBERS = 478 SF
DRAIN FIELD CROSS SECTION - TVP.
F
4,0' MAX
LIMIT OF EXCAVATION
ter— 4" PVC
OBERVATION
PIPE
TRENCH SPECIFICATIONS
WIDTH OF TRENCHES - 3 FEET -1 CHAMBERS
LENGTH OF TRENCHES - 68.75 FEET - 11 CHAMBERS
TOTAL NUMBER OF CHAMBERS - 33
TOTAL INFILTRATIVE AREA - 511.5 SF
THREE TOTAL TRENCHES
GRAVELLESS
CHAMBER
(0.25' x 3')
5' MIN
�--6' MIN---►+,/
SCARIFY
SURFACE
PLAN VIEW - TYP.
OBSERVATION PIPE
10
1 r1
TRENCHES
INSTALLED
LEVEL
GRAVELLESS CHAMBER
1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1
6 FEET MIN
PROJECT NO. 1058
0 1 1 1
68,75 FEET
1
FEET
4" PVC LINES FROM
DISTRIBUTION BOX
FIGURE 2
GARFIELD COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1058
PROFILE PIT
0-1'
1'-8'
Date of Test: 3-2-05
Sandy Loam, Root Zone
Sand, Clayey, Slightly Gravelly, Dense, Moist, Red/Brown
No Groundwater or Bedrock was Encountered
Hob Hob Interval Measurement at Measurement at Change (in) Percolation Rate
No. Depth (in.) (min.) Start of Interval End of Interval (min./in.) MPI
(in.) (in.)
1 39 20 3.50 5.75 2.25
20 5.75 7.00 1.25
20 7.00 8.00 1.00
20 8.00 9.25 1.25
20 2.75 4.00 1.25
20 4.00 5.00 1.00
2 40 20 3.25 6.00 2.75
20 6.00 7.50 1.50
20 7.50 9.00 1.50
20 2.00 3.50 1.50
20 3.50 5.00 1.50
20 5.00 7.00 2.00
3 34 20 2.50 4.50 2.00
20 4.50 5.75 1.25
20 5.75 7.00 1.25
20 7.00 8.25 1.25
20 3.50 4.50 1.00
20 4.50 5.50 1.00
AVERAGE = 18 MPI
20
14
20
DLL
SEBYII
ApPillit 2005
PO Box 2844
Glenwood Springs, C0 81602
Ph 970-6111-5033
Fax 303-216.2796
Mickael Miernicki
950 Cowan Drive
Carbondale, Colorado 81623
Installation Observation, Proposed Residence
Lot 4, Prince Creek Estates
Garfield County, Colorado
Project No. 1058
Mike,
ALL SERVICE septic, LLC performed an installation observation on April` 6th awl April 12`s 2005
for the subject property.
The installation included one 1500 -gallon, two-compartment precast concrete septic tank, followed
by three gravelless-chamber trenches, with 17 `Quick -4' chambers in each trench. A total of 51
chambers were installed for a total of 503.4 SF of infiltrative area. A plastic distribution box was
installed to distribute effluent. The distribution box was buried and identified using a 4 -inch PVC
pipe. Risers should be used to bring tank access to grade, and effluent filter handles should be
extended if necessary. Field should be re -vegetated as soon as possible.
The OWS was installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes
are made to the OWS.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
ginothyR Petz
2 copies sent
Reviewed B
AC"a
Richard H.