Loading...
HomeMy WebLinkAbout03972GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit 3 9 72 AssessorN.'s Pareel No. 109 8th Street Suite 303 , Glenwood Springs, Colorado 81601 Phone (303) 945-8212 P INDIVIDUAL SEWAGE DISPOSAL. PERMIT PROPERTY i r 0r ' �CCal A—tatwes *I3 WI' 3o3-(o9a—S3y1 Owner's Name Iz System Location 0030 Present Address Phone , C R I IS 6ki Sr; Ays q, -If WWI -111 This does not constitute a building or use permit. • Legal Description of Assessor's Parcel No 1 SYSTEM DESIGN / Septic Tank Capacity (gallon) Other Percolation Rate (minutes/inch) Number of Bedrooms (or other) Required Absorption Area - See Attached Special Setback Requirements: Date Inspector ' FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation t 1 1 1 System Installerl Septic Tank Capacity ^I t /4•it� -4G (f j7- Septic Tank Manufacturer or Trade Name ® 1 ALI Septic Tank Access within 8" of surface Absorption Area Sic^'DQ Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and State regulations/requirements Other Date $ 75404 Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs,alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6 months in jail or both). White - APPLICANT Yellow - DEPARTMENT f 1 INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER J.—titbit S /4c Chi In ADDRESS 413 Le5t- q, R 4 fietj.,'5a1, 6, S' N65PHONE (3o3)gra-5511 CONTRACTOR M' Ifs g4//9y ex-cot✓dr,11 J iG ADDRESS PHONE "I Sq'33og PERMIT REQUEST FOR Of NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: �^ Near what City of Town 61e400,01 7?h).t15 Size of Lot_ 0.3 3 p Legal Description or Address ®e 31 Cewn ri gem) 115 I e4 wood $1911/4,75 Co $ / 6 o / WASTES TYPE: fklbWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER—DESCRIBE BUILDING OR SERVICE TYPE: 41-ehov5e / i\5rr:kris/1 Ce4rtr— Number of Bedrooms ( ) Garbage Grinder Number of Persons ( ) Automatic Washer ( ) Dishwasher SOURCE AND TYPE OF WATER SUPPLY: p<TWELL ( ) SPRING ( ) STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: u Was an effort made to connect to the Community System? ye 5 A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table Percent Ground Slope 1 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: SEPTIC TANK VAULT PRIVY PIT PRIVY AERATION PLANT ( ) VAULT COMPOSTING TOILET ( ) RECYCLING, POTABLE USE INCINERATION TOILET ( ) RECYCLING, OTHER USE CHEMICAL TOILET( ) OTHER -DESCRIBE FINAL DISPOSAL BY: d ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER -DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? M o PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes 1 7 per inch in hole No. 1 Minutes t7 per inch in hole No. 3 Minutes 10 per inch in hole No. 2 Minutes per inch in hole No. _ Name, address and telephone of RPE who made soil absorption tests: 14 P 6.e0reck 5D20 CounryRol I57 ,Ir4&04 5 ,4a'5, Co i'160( po 970 -9Y6 -nn- // Name, address and telephone of RPE resBible fpr design of the system: 10, 4 Covarrr to ,iepr.h; 1517 &lake l}veootj(21 G(ensocntSpiItp7 en 61601 qio-945- $676 Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed // / Date g--;.9-7-0011 PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!! • HP &ech HEPWORTH-PAWLAK GEOTECHNICAL May 19, 2004 Weatherall Company, Inc. Attn: Shawn Preston 6230 County Road 335, Unit B New Castle, Colorado 81637 Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 email: hpgeo@hpgeotech.com Job No. 104 347 Subject: Percolation Testing, Proposed Septic Disposal System, 0037 County Road 115 (Red Canyon Road), Garfield County, Colorado. Dear Mr. Preston: As requested, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. The work was done in accordance with our agreement for professional services to Weatherall Company, Inc., dated April 28, 2004. We understand that due to area constraints, a seepage pit is being planned for septic disposal. A long pit had been excavated off of' the northwest corner of the existing building by the client prior to our arrival on-site. The pit had been terraced with a percolation test holes excavated at each of three levels at about the locations shown on Figure 1. The subsoils exposed in the pit consisted of about 4 inches of asphalt overlying silty sandy gravel with cobbles and boulders to the maximum depth of 14 feet. No free water was observed in the pit and the soils were slightly moist to moist. Percolation test holes had been soaked by the client prior to our arrival. Percolation testing was conducted on May 13, 2004, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table 1. The percolation test results indicate an infiltration rate between 17 and 40 minutes per inch with an average rate of 32 minutes per inch. If you have any questions or need further assistance, please call our office. Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthorne 970-468-1989 Weatherall Company, Inc. May 19, 2004 Page 2 Sincerely, HEPWORTH - PAWLAK GEOTE Jordy Z. Adamson, Jr., P Rev. by: DEH JZA/djb attachments Figure 1 - Location of Percolation Test Holes Table 1 - Percolation Test Results cc: High Country Engineering - Attn: Roger Neal Job No. 104 347 C"-Artiier'in wv- APPROXIMATE SCALE = 60' 104 347 HEPWORTH —PAWLAK GEOTECHNICAL, INC. LOCATION OF PERCOLATION TEST HOLES Figure 1 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 104 347 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 132 5 10 15 10 91/2 '/2 1 7 9'/2 81/2 1 81/2 7'/e % 7'/e 7 % 7 6'% % 6'% 5'/4 % 51/4 4 % '/e 4% 31/2 % P-2 96 5 10 15 9% 91/2 '/2 40 9'% 8' 1/4 8' 8% % 88/8 8 s/e 8 7'/2 1/2 7'/2 7'% e 7% 68/4 62/4 6% % P-3 60 5 10 15 9'% 88/4 e 81/4 8% }/8 8/ 8 e 8 71/2 1/2 71/2 7'% 8/8 7/e 6% % 6% 6% e 68 6 24 40 Note: Percolation test holes had been dug in the bottom of a backhoe pit and soaked by the client prior to our testing. Percolation tests were conducted on May 13, 2004. The average percolation rates were based on the last three readings of each test. I+ 6 .ondition authority For the 10) feet the of ement VICINITY MAP SCALE: 1'=2000' ]ii]ir atia !tC • o0 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR FACTORIES AND PLANTS (per employee per 8—hour shift—no showers): 20 GALLONS/PERSON/DAY • 2 PEOPLE. IS: 40 GPD = AVERAGE DAILY FLOW, DESIGN FLOW = 1.5 • AVERAGE = 60 GPD (0) SEPTIC TANK: MINIMUM TOTAL TANK SIZE: Q • 1 DAY/24 HRS * 30 HRS = 75 GPD INSTALL ONE 1000—GALLON TANK WITH BAFFLE ***INSTALL EFFLUENT FILTER IN SEPTIC TANK OUTLET*** STANDARD ABSORPTION AREA: A = Q f Q=MAXIMUM FLOW t=PERCOLATION RATE = 32 min./in. _ X75 3%2 = 85 SF INCREASE BY 20% FOR GARBAGE GRINDER A = 102 SF USE OF DRYWELL: DIAMETER OF PIT = 7': THEREFORE, BOTTOM AREA = 38 SF DEPTH BELOW INLET= 6': THEREFORE, SIDEWALL AREA = 176 SF TOTAL ABSORPTION PROVIDED = 214 SF. 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. p�N ae�; z-Nz 0o�: 6 8 ImD(LiOi b n zrE,crlo 06o!• r REVISION W Q 0 z 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLINGALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. PERCOLATION TESTING PERFORMED BY H.P. GEOTECH, MAY 13, 2004. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO CITY. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM HIGH COUNTRY ENGINEERING, INC. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. DRYWELL SYSTEM NEEDS TO BE A MINIMUM OF 10 FEET FROM THE PROPOSED PROPERTY BOUNDARY AND A MINIMUM OF 50 FEET FROM THE HIGH WATER LINE. 1. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND DRYWELL, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 2. AREA BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 3. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 4. UNSUITABLE MATERIAL EXISTING WITHIN THE BED SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. PROJECT NO. 2041016.00 21 1 / 1 APPROXIMATE LOCATION OF DRYWELL SYSTEM (PER CONVERSATION WTIH BILL INVERSO)/ 25' MINIMUM DISTAN POTABLE WATER SUPPLY APPROXIMATE LOCATION OF SEPTI1 (PER CONVERSATION WTIH BILL IN SWING TIES POWE9 POLE BRICK WALL m CONCRETE WALK 4" SCHEDULE 40 SEWER (TYP.) WITH CONCRETE CIICACCMENT rrn DETAIL AND TAOLC 2 POLE WITH FLOVOLL / OVERHEAD ELECTRIC (TYP.) GUY WIRES POWER POLE TELE. PED. 1,000 GALLO EXISTING WELL �\ \ (PER CONVERSATION WITH SANDY LOWELL) NOO ISMO'-3bd m Nm 0 1 r1 O m r m 2 T / (I)E mEl rt M MZ D m Z z —1 0 m i Ps aF Zy 0r a8 84 Ny zi 00 (e. -4 mm Oy fg 0T 00 mm 9Gt-3 OAd Of 311I03H3S 0. 0 Mae 3AI110 30111 .31 gE RR 2 Segc Tanks, Tmmeni Phan, Dmp TWµ nigh 4 Lf£l 1 A ]($E (9 ! ge Fgm� 119 > s sF QQ 39',�yi 6ipL sFi idi- a€l4 HU Rig �>yy�, 3 $g$�p W a R - 1 o >1 $. E o- = P== x s 8 8 8 888=-m0 r E - - __a I:zit It uw tit t eu an CTU w C ,. �' C `6 £ np=6q' 3 ZI5 F 8 8 E gl SSSSiJ. - 3 o 8 e 8 e .. 8 La01 l - 8 e e- 3 8 3 8 0 id 1 1:1 - ill 81;!8 8 M ,. 8 87-,8V, N R g' 0 REMOVABLE PVC CAP INSTALL MARKER IF CAP IS TO BE BURIED FINISH GRADE 4" COUPLING 4" SEWER LINE 4 4" RISER 4" 45' SWEEP BEND 4" x 4" x 4 PVC WYE yo CLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N.T.S. PROVIDE /j5 AT FOUR COR #4 TIES 016 ALL -THREAD IF REQ'D FOR CONCRETE PL COMPACTED CIVIL ENGINEERING August 25, 2004 Andy Schwaller Garfield County Environmental Health 108 8"' Street, Suite 201 Glenwood Springs, CO 81601 An Employee -Owned Company Re: Weatherall Company ISDS HCE Project Number 2041016.00 x 0218 Dear Andy: RECEIVED AUG 2 5 2004 BUILDING & FL NITNG LAND SURVEYING The following letter is to confirm the engineer's acceptance of the designed septic system of the Weatherall Company on Red Canyon Road (County Road 115). The design included a 1,000 gallon septic tank and drywell. The septic tank, drywell, cleanout, and vent pipe have been installed. The concrete encasement has been changed and approved to flowfill. At time of inspection, the effluent filter was not installed, but per phone conversation with client, it has now been installed. With the above noted changes, the system has been completed with the intent of the original design If you have any questions, or need additional information, please contact us. Sincerely, " : • I alitt Senior Project Manager 1517 Blake Avenue, Suite 101 Glenwood Spnngs, CO 81601 970.945.8676 phone 970.945.2555 fax ERING, INC. Deron Dlreksen, E.I. Project Engineer www.hceng.com 14 Inverness Drive East, Suite F-120 Englewood, CO 80112 303.925.0544 phone 303.925.0547 fax