Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970 ·945·8212 Fax: 970·384-3470 Inspection Line: 970·384-5003 Building Permit No. Parcel No: 2179-233-00-202 ------------------- Locality: Job Address: 260 Lazy S Reverse S Drive 1 New C4<;fie. Use of Building: Fence --------- Owner: Smith, William Contractor: Pyramid Fees: Plan Check: $ 63 .21 Septic: Bldg Permit: $ 97 .25 Other Fees: Total Fees: $ 160.46 Clerk: \ l ~\~ __ cJ Date: CQ-\l~oK I 1 2 3 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 401 , Glenwo od Springs , Co 8 1601 Phon e: 970-945 -82121 Fax: 970-384-3470 I Ins pection Line: 970-384-5003 www. garfi e ld -county .com Parcel No: (this informatio r;t is available at the assessors o ffi ce 970-945 -9 134) ,Z/77-Z.J -:?oozo? Job Address : (if an address h as not been assig ned, p lease p rovide C r, Hwy o r S treet N a m e & C ity) or and le gal description Zbo L:Jl?r s ?t:v cr2.J£ .s 'IA<:WL-~..ze-.J a~u: Co Lot No: Block N o: Subd./ Exemption: 8 10?)'2- ~(\~ ~t\~ 4 Owner; (pro pe ny o wn~ R Maili1> Addr{Jfp , _ES '" :J c Ph: ~\ ~?> .. 01-1 l.,)Ji(ffti-1 sn 74 -~ c,~ I ~;:.L'/ to ·c;?o ·-C!K-lf!c5 z 5 ~Ya~r: ·~ Mailing Address: <5..511 "7ll.J'PII rH '1!f) Ph : AitPh: J\:1"1'1 I Jf z~>l >Yi?~rcc.Jjc pJ-j !"3b5'f 67~ -67$-GnZA::J b 18-777-'125> 6 Architect I Engineer: Mailing Addre~t:) [{Lt'";f t:ct£A11 ~ ~Ph: Alt Ph : Ctf 5 uv6r-NrrR~ f'"'A(I SY, 'Jo.Gt.JfL AJ I)Zt 7 Jt5-'15-:J-l~o a 7 Sq. Ft. of Building: A Sq. Ft. or Acres of Lot: L/0 Height: N~ No .oL~s: N . ,N ~ 8 Use of Building:~ lkr &V'\ce....'-0ur.l../ -::---... 9 Describe W ork: ~~ ~~'' ~·" rl(,, tl~ f-)) I ~ trlliA lil a:J ctJ;o:;>:S 'j iZoe:r ~"· j r"Jl~ J f 'f='ttvCrO 9G~~, q:. 10 Class of Work: "'--../ "'jjtNew o Alteration 0 AOOi{]On 11 Garage: N~ Se pti c : o Attached 0 Detached o iSDS o Community 12 Driveway Permit: NA Owners valuation of Work: $ -6·e _, C,"C)o t:j_ O<!JO NOTICE I Auth ority. This applic ation fo r a Building Permit must be s igned by the Owner of the property, d escribed above , or an a uthorized ageol lf the s ig nature below is oo! that o f !he O wner, a se para te letter o f authority, s igned by !he O wne r, mus t be provided with !his Application. Legal Access. A Building Permit canno t be issued witho ut proof o f legal and adequate a ccess to !he property for purposes of inspections by !he Building Departme nt. Other Penn its. Multiple separate permits may be required: (I) State Electrical Pe rmit, (2) C ounty ISDS Permit, (3) anothe r permit required for use o n !he pro perty identifi ed above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit Void Pennit A Building Permit bec omes null and void i f !he work authorized is no! comme nced w ithin 180 d ays of !he date of issuance and if w ork is suspende d or abandoned fo r a period o f 180 days after corrunencement CERTIFICATION I hereby certify !hat I have read this Appli cati on and !hat !he information contained above is true and correct. I u nderstand !hat the Building Department accep ts !he Applica tion, along w ith !he plans and spec ific ations and other data s ubmitted by me or on my behalf (submittals), based upon my c ertifi cati on as to accuracy. Assuming comple te nes s o f the s ubmittals and a pproval of !his Application, a Building Permit will be issue d granting permission to me , a s O wne r, to construc t !he s tructure(s) and fac ilities detailed on !he submittals reviewed by !he Building DepanmenL Io c ons ideration of !he issuance of tbe Building Permit, I agree !hal l and m y a gents will comply with provis io ns of any fede ral, s tate or loc al law regulating !he work and !he Garfield C o umy Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Bui.lding Permit may be s us pended or revo ke d , u pon n otice from !he C ounty, if the location, construc ti on or u se of !he s tructure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any o ther applic able law. I he re by grant permission to !he Building Department to ente r the property, described above, to inspect !he work. I further acknowledge th at !he issuance of the Building Permit does not pre vent !he Building Offic ial from: (I) requiring !he correc ti on of erro rs in !he submittals, if any, discovered after is s uance; or (2) stopping cons truction or use of !he s truc ture(s) or facility(ies) if such is in vi olation o f County Regulation(s) or any othe r applicable law. Review o f this Application, inc luding submittals, and inspections o f !he work by the Building Department do not constitute an a cceptance of resp onsibility or liability b y the C o unty of e rrors, omissi ons or discrepanc ies . As the Owne r, I acknowledge !hat respo nsibility for c ompliance with fede ral, state and local laws and County Regulations rest with me and m y authorized age nts, including witho ut limitation my arc hitec t designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNO ERST AND THE NOTICE & CERTIFICATION ABOVE: ·:z-» /d{ ~#a~r/J Atf4ff ~f( CJ;--~C / _7c .. -vr!> OWNtRS'SIGNA TIJRE DATE ~-· --rt" STAFF USE ONLY Special Conditions: R.uo Z,.0\0~ ~ 'ST -I Ol.o)U Adjusted Valuation: Permit Fee: 6\)Q. 0'0 1/-~5 - ISDS Fee: Total Fees: BP No & Issue Date: ISDS No & Issued Date: ~ ~ I - Setbacks: DATE GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Departtnent. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24 '"' and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade 1 line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building materiaL Engineered foundations may be required. Check with the Building Department. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 36 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IBC, IPC, IMC, IFGC, and IFC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each comer of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision fmal plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the fmal plat with the prop~tructure located within the envelope. Yes 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. , / • Yes Not necessary for this project~ 3. Does the site plan indicate the location and direction of the State, County or private road accessing the prop_eryY? Yes~ 4. Is the I.S.D.S. (Individual Sewage Disposal Sys\j_em designed, stamped and signed by a Colorado Registered Engineer? Yes Not necessary for this project-'--'="~ 2 5. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifYing them as "Not for construction, for permit issuance only", "Approval drawings only" y:__r permit issuance ouly" or similar language? Yes Not necessary for this project. __ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accor~rce -~ith the building code or per stamped engineered design? Yes~ot necessary for this project __ 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes __ Not necessary for this projectL 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood an<\ yarth? Yes __ Not necessary for project_]::::::- 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? -.....1 Yes Not necessary for this project /'..... ---- 10. Do the plans include design loads as required under the IBC or IRC for roof snow loads, (a minimum of 40 pounds per square foot in Garfield County)(;. Yes Not necessary for this project ('.... -- -- 11. Do the plans include design loads as required for floor loads under the IBC or IRC? Yes __ Not necessary for this project_)(__ 12. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes L Not necessary for this project __ _ 13. Is the wind speed and exposure design included in the plan? Yes --Y.::-Not necessary for this project __ 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes __ Not necessary for this project~ 3 15. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes __ Not necessary for this project:J,__ 16. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check applicable zone district for building height maximum) Yes~ Not necessary for this project __ 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certification~:r Phase II EPA certification? Yes __ Not necessary for this project 18. Does the plan include a masonry fireplace inc\l}ding a fireplace section indicating design to comply with the IBC or IRC? ]\__ Yes __ Not necessary for this project __ 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with thvequirements of the IBC or IRC? Yes __ Not necessary for this project!'--__ 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? ~ Yes Not necessary for this projec ---- 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazing for these areas? '\( Yes __ Not necessary for this project~ 22. Do the p~include a complete design for all mechanical systems planned for installation in this building? Yes No Not necessary for this project __ _ 4 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the IBC Chapter 3) Yes __ Not necessary for this projec~ 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes __ Not necessary for this project~ 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes-T=-Not necessary for this project __ · 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both sexes? Yes __ Not necessary for this project~ 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes __ Not necessary for this project-\:- 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes--+__ 29. Have you designed or had this plan designed while considering building and other construction code requirements? Yes~ 30. Does t~ accurately indicate what you intend to construct and what will receive a final inspection by the rfield County Building Department? Yes 31. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For comet-see supplemental section 5.05.03 in the Garfield County Zoning Resolution for setbacks. Yes 32. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes-J( 5 33. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Roa~act" fees required, at the time you pick up your building permit? Yes 34. Are you aware that you are required to call for all inspections required under the IBC including approval on a fintspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an A~t and that the party responsible for the project must comply with the Uniform Codes? Yes__L:::_ 36. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes~ 3 7. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $5o.qo r-inspection fee? Yes+ 38. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; a County Road and Bridge permit; a Colorado Dept. of Highway Permit including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See Phone book for other agencies Yest 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perff/: installations and hookups? The license number will be required at time of inspection. Yes 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcell Schedule Number for the lot you are applying for this permit on prior to submittal of the building pe:{.:pplication? Your attention in this is appreciated. Yes 41. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? _ I Yes.:::t__ (Please check with the building department about this requirement) 6 42. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will tequired to obtain a grading permit? Yes__ Not necessary for this project 43. Did an Architect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than 10 persons as per Section 1004 of the IBC to prepare the plans and specifications for the project. j Yes__ Not Necessary for this project I hereby acknowledge that I have read, understand, and answered these questions to the· best of my ability. Date ~ £' )18k' Phone:(1°~ 7'1.: (days); }OJ ';z.&~ }l 8 ~ (evenings) (7)'-J t f2.. (f-1./J s;;&J>j;S Project Name: 'Ef,'ff{.[... (...)4 Tr tl. Project Address: _______________ _ Note: On any ofthese questions you may be required to provide this information. If required information is not supplied, delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first positior for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. BpcommDec2007 7 . GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, JM:C, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snow load (measured at the roof): 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. 75PSF 8001 to 9000ft. lOOP SF 9001 to 10000ft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2. 1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • • • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. Floors R-values are R-19 . • • • Basement wall R-values are R-10 beiow grade, R -19 above grade. Slab perimeter R-value and depth is R- 10/36in. Crawl space wall R-values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. No. 10981 Assessor's Parcel No. 2179-233-00-202 Date 6/11/2008 BUILDING PERMIT CARD Job Address 260 Lazy S. reverse S.drive. New Castle Owner Smith William Address box 8771, silt Phone # 618-4182 Contractor pyramid Address 6519 town path rd E.Syracuse, NYPhone # 303-328·5788-Ross Setbacks: Front Rear RH LH Zoning ____ _ fence Soils Test-------------Footing--------------Foundation ___________ _ Grout ______________ ___ Underground Plumbing ______ _ Rough Plumbing ________ _ Framing _____________ _ Insulation -------------Roofing--------------Drywall ---------------Gas Piping ____________ _ INSPECTIONS Weatherproofing ____________ _ Mechanical ______________ _ Electrical Rough (State)----------Electric~ F}nl!l ~tate) ~ Final t5--!-W /Checklist Completed? @PC Certificate Occupancy # ________ _ Date ____________ _ Septic System # ____________ _ Date -------------Finall ____________ _ Other_~~====------------NOTES (continue on back) BUILDING PERMIT GARFIELD COUNTY, COLORADO INSPECTION WILL NOT BE MADE UNLESS THiS CARD IS POSTIED ON THE JOB Date lssued_~(t,--'-'-fi~--'Ot"------~ Permit No.~\ ~oq_t_-'--1 -~- AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. use fence Address or legal Description auo la."Ll1 s (Zeven;e ~ I>ri ve., NtW CDS+IiJ Owner 5ln\ th, W\(\tllM Contractor__.'P~'dl-'-rnM~Il-!fA~~~­ Building PermitType 1Z.t<t.\dtotf""Cl("""'---------------------- This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footi~g ~riveway - Foundation I Grouting Insulation Underground Plumbing Drywall Rough Plumbing Electric Final {by State Inspector) (Prior to Final) Rough Mechanical Septic Final Gas Piping FINAL ~ '8'-f-oZ Electric Rough (by State Inspector} (You Must Call For Final Inspection) (Prior to Framing) Notes Framing (to include Roof in place & Windows & Doors Installed & Firestopping in pl<~ce) THIS PERMIT IS NOT TRANSFERABLE for Inspection Call970-384-5003 Office 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD APPROVED '1(-0t ,;-\ i~4J Date \?"" ·'-------By~ J[.lflt1{l,AI) U ~"------ PROTECT PERMITFROM WEATHE DA AGE (DO NOT LAMINATE) Site Name: Rifle SENSIS Site ID #: Greenfield EXHIBITC AUTHORIZATION IN REGARD TO APPLICATION FOR AND PURSUING SPECIAL USE PERMITS OR SIMILAR PERMITS AND APPROVALS The under.;.igned parties, William V. Smith and Eunice M. Smith (the ''Ov.ner''), hereby authorize SENSIS to act as agent fur the Owner in regard to the filing, bringing, undertaking, pursWng and resolving any application(s) (the ''Application") for special use permits, or other permits, approvals, consents or authorization equivalent in pwpose to a special use permit, which wiJt enable lhe construction of a Communication site on and which may be necessary to enable SENSIS to use certain property of the Owner, which is more particularly described on Exhibit "A'' attached hereto and made a part hereof, as contemplated by that certain Communication Site Agreement between Owner and SENSlS of even date herewith. SEN SIS is hereby authorized to act as agent on behalf of the Owner in regard to the Application pertaining to the property set forth on Exhibit "A" and for those purposes only. This is a limited power of attorney and authorization which shall not be for any purposes other-than those set forth hereinabove. IN WITNESS WHEREOF, the undersigned has set its hands under seal thi~ day of (\.Ao y , 2007. Signed, sealed and delivered in the presenceof: jl I (NOTARY SEAL) My Commission Expires: ~ J., CAC'o!t William V. Smith landlord /) ~ L~ J iff_ ~(SEAL) Swtice M. Smith Landlord Owners Initials tJ'Y' :J i'tt:.J SENSIS Initial<-c:::9-e_(/}~=- Parcel Detail Page 1 of 4 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Property Search I Assessor Subset Query I Assessor Sales Search Clerk & Recorder Reception Search Basic_Buildillg Characteristics I Tax Information P~ar_geLDet~il I Value Detail I Sales Detail I Residential/Commercial Improvement Detail Land Detail I Photographs ~ & ~ I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 023 II R023051 II 217923300202 II 45.55 1 I Owner Name and Mailing Address lsMITH, WILLIAM V. & EUNICE M. I ~60 LAZY S REVERSE S DR INEW CASTLE, CO 81647-9684 I Assessor's Parcel Description (Not to be used as a legal description) lsECT,TWN,RNG:23-6-92 DESC: NESW IBK:0588 PG:0365 BK:0546 PG:0796 IBK:0 545 PG:0781 BK:0653 PG:0444 IBK:0627 PG:0499 BK:0627 PG:0498 Locat~. - \ / Physical Address: 1 [467 ~ 11 COUNTY RD SILT I Subdivision: I Land Acres: 1140 I Land Sq Ft: llo l Section II Township II Range I 23 II 6 II 92 I 2008 Property Tax Valuation Information http://www .garcoact. com/assessor/parcel.asp ?ParcelN umber=21 7923 3 00202 5/16/2 008 Parcel Detail Page 2 of 4 II Actual Value II Assessed Value I I Land: 120,00011 9,5501 I Improvements: 175,59011 13,9801 I Total: 295,59011 23,5301 Sale Date: 116/23/1995 Sale Price: 1192,000 Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd 0 Buildings: Residential Building Occurrence 1 Characteristics I TOTAL HEATED AREA: 111,568 I II SINGLE F AM. RES-ABSTRACT CODE: )MPROVEMTS I ARCIDTECTURAL STYLE: IIMODULAR-UBCIIRCIIBC I EXTERIOR wALL: IIVINYL I ROOF COVER: IICOMP SHNGL I ROOF STRUCTURE: IIGABLE I INTERIOR WALL: IIDRYWALL I FLOOR: llsHT VINYL FLOOR: IICARPET HEATING FUEL: IlGAS HEATING TYPE: IIFORCED AIR STORIES: IISTORIES 1.0 BATHS: 12 ROOMS: 16 I UNITS: II I BEDROOMS: 13 I YEAR BUILT: 111995 I Tax Information Tax Year II Transaction Type II Amount I 2007 lli===T==ax==P=ay=m=e=nt=: ="pi'=rs'=!t =:H=cal""f ==ill' I ==(7$3:=5==4=.6'50)1 http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=217923300202 5/16/2008 Parcel Detail I 2007 Senior Tax Exemption ($362.60)1 I 2007 Tax Amount $1,071.801 I 2006 Tax Payment: Second Half ($224.46)1 I 2006 Tax Payment: First Half ($224.46)1 I 2006 I Senior Tax Exemption ($354.88)1 I 2006 II Tax Amount $803.801 2005 II Tax Payment: Second Half ($402.18)1 2005 II Tax Payment: First Half ($402.18)1 2005 Tax Amount $804.361 2004 Tax Payment: Second Half ($414.47)1 2004 Tax Payment: First Half ($414.47)1 2004 Tax Amount $828.941 2003 Tax Payment: Second Half I ($461.37)1 2003 II Tax Payment: First Half II ($461.37)1 I 2003 Tax Amount II $922.741 2002 Tax Payment: Second Half I ($465.26)1 2002 Tax Payment: First Half ($465.26)1 2002 I Tax Amount $930.521 2001 Tax Payment: Second Half I ($462.84)1 2001 Tax Payment: First Half ($462.84)1 2001 Tax Amount $925.681 2000 Tax Payment: Second Half ($426.25)1 2000 Tax Payment: First Half ($426.25)1 I 2000 Tax Amount $852.501 I 1999 Tax Payment: Second Half ($424.23)1 I 1999 Tax Payment: First Half ($424.23)1 I 1999 Tax Amount $848.461 TopofPag~ Assessor Database S~m:ch_Qptions I Iref!Sl.l[er_l)at_ab_as~_S~archOptiQ!JS Clerk & RecordeLDambase Search Options Garfield County Home Page Page 3 of4 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices http://www .garcoact.corn/ assessor/parcel.asp ?ParcelN umber=21 7923 3 00202 5/16/2008 "' "' ..... ~ ~ r: 0 '-' / 0 G:l c;: z tj "" "' I "' "' / Ul Vi ~ Ul / 0 0 ~ / Ul Vi z w Ul / Vl w u 5 Q: w V1 "' Q: 0 6 z 0 ~ < a:: ,_ Q. I N 0 0 0 "" 0 / '0 ~ .E .... ~ N >. a:; a.. •............... ·.t.· ···--·---~--~.::~.·-···· :;.:.: ... .:..~""r"'"' . _, ___ ....... ~ ·-·-----~'-..... ..:.·.: ..... · ... · .• "' · ........... :.:---..-::-.'-.-, . .:.:.·...-(.:-:;·· .• ~ .• -..•. \ ~==--:-... : .•..•. ; .... · .. · ... -......... ·. : ........... _._, __ ..... _.., _____ --------·-... ·-···-... . ..... ·---, ..... · ... 01 01A 018 01C 02 03 04 04A 05 06 06A 07 08 OBA 09 10 11 12 13 SITE INFORMATION PROPERTY OWNER: WILLIAM V. & EUNICE M. SMITH PO BOX 871 SILT, CO 81652 CONTACT: WI LLIAM SMITH PHONE: (970) 6 18-4182 TOWER OWNER ID NO .: TB D FCC NO.: TBO APPLICANT: SENSIS 85 COLLAMER CROSSINGS EAST SYRACUSE, NEW YORK 13057 SITE ADDRESS: 260 LAZY S REVERSE S DRIVE NEW CASTLE . CO 81652 COUNTY: GARFIELD LATITUDE: 39' 30' 35" N LONGITUDE: 1 07' 38' 05" W ZONING JURISDICTION: GARFIELD CO UNTY ZONING CLASSIFICATI ON: ARRD -AGRICULTURAL/RESIDENTIAL/RURAL DENSITY SITE NAME: GREENFIELD SITE I.D. NUMBER: R6 CONSTRUCTION DRAWINGS AREA OF CONSTRUCTION: PROPOSED USE: POWER COMPANY: SECTION/BLOCK/LOT: EN GINEER: CONTACT: PHON E: ±900 s.f. COMMUNICATIONS FACILITY HOLY CROSS ELECTRIC CO-OP 2 179-23-300202 C&S ENGINEERS IN C. · 499 COL. ElLEEN COLLINS BLVD. SYRACUSE, NEW YORK 1 3212 ROBERT N. DUCLOS, P.E. (315) 455-2000 DRAWING INDEX SITE Plf{\N P RTYPLA ~. SITE P~N SITE PLAN, SHELTER LAYOUT AND TOWER ELEVATION CONSTRUGTION NOTES CABINET DETAILS ICEBRIDGE DETAILS ANTENNA SUPPORT DETAILS ELECTRICAL NOTES AND ONE-LINE ELECTRICAL DETAiLS GROUNDING NOTES AND SCHEMATIC GROUNDING D~TAILS ~· GROUNDING Dff.TAI LS GROUNDING D ~TAILS ANTENNA AND 1CABLE SCHEDULE PROPANE TANK DETAI LS LIR STRUCTURE DETAILS FENCE DETAIL~ 499 Col. Eileen Collins Bl vd. Syracuse, New York "13212 Ph one 315-455-2000 Fax 315·455·9667 www.csc os.com Pyrnrnid N~1work Services. LLC GSII TOWPAlH ROAO EAST SYRACUSE, NEW YORK f3DS7 REV 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 LOCATION MAP DIRECTION S (FROM STEAMBOAT SPRIN GS AIRPORD : TAKE COUNTY ROUTE 12 9 SOUTH TO A LEFT TURN ONTO US ROUTE 40 SOUTH. TRAVEL ON US ROUTE 40 APPROX. 6 MI LES TO A RIGHT TURN ONTO STATE ROUT E 131 SOUTH. TRAVEL ON SR131 FOR APPROX. 6 .5 MILES TO A LEFT TURN ONTO COUNTY ROUTE 14. TRAVEL ON CRH SOUTH TO STATE ROUT E 131 AND CONTINUE SOUTH ON SR131 APPROX . 28.6 MILES TO A RIGHT TURN ONTO CR3D (COLORADO RIVER ROAD). FOLLOW CR30 (COLORADO RIVER ROAD) TO 1-70 WEST. TRAVEL 1-70 WEST TO EXIT 9 7 . TAKE LEFT OFF RAMP, CROSS 1-70. TRAVEL 0.1 MILE AND TURN LEFT ON RIVER FR ONTAGE ROAD. TRAVEL 0.3 MILE AND TAKE FIRST RIGHT ONTO DIVIDE CREEK ROAD (CR311). TRAVEL 0.5 MILE AND VEER LEFT AT 'Y" (ROAD REMAINS DIVIDE CREEK ROAD (CR 311)). TRAVEL 1.3 MILE AND TURN RIG HT (ROAD REMAINS DIVIDE CREEK ROAD (CR 31 1 )). TRAVEL 2.5 MILES AND LOOK FOR NUMEROUS MAILBOXES ON RIGHT. THIS IS 6 LAZY K RANCH PRIVATE DIRT ROAD. TURN RIGHT ONfO 6 LAZY K RANC H ROAD , GO SLOW ... l 0 MPH SPEE D UMIT. CROSS BRIDGE AND GO RIGHT ON 6 LAZY K RANCH ROAD. CONTINUE STRAIGHT ON 6 LAZV K RANCH ROAD (DO NOT TURN ONTO 30 RANC H). CONTINUE ON 6 LAZY K RANCH ROAD AN D LOOK FOR GAS WELLS ON RIGHT. AT TOP OF HILL TURN RIGHT LOOK FOR SMALL HANGING WOODEN SIGN THAT READS "LAZY S REVERSE S". THIS IS THE DRIVEWAY FOR THE SMITH PR OPERTY. FO LLOW DRIVEWAY TO THEIR HOUSE (WHITE HOUSE WITH GREEN ROOF), TURN LEFT TOWARDS BARN. SITE IS BEHIND BARN NEAR TRAILER AND WHERE SPARE EQUIPMENT IS STORED. I ~. -N - ~ APPRO ~TO O:CEPTIONS & GARFIELD BUILDING ..... t.e ""'~ -Q~ By FIELD C NO IHSftECTION ·.NIH f't.ANI ON "Jtltf' ot \. SITE NAME: GREENFIELD SITE I.D. NUMBER: R6 260 LAZY S REVERSE S DRIV E NEW CAS TLE, CO 8 1652 SENSIS EXISONG T8..CO DEMARC, PROPOSED SOURCE Of TELCO SERviCE {TO BE CONFlR!.IEO BY UTIUTY) 1 r I EXISTING DIRT ROAD ~~~---~--------------- /--------/ PROPOSED UNDERGROUND / TELCO SERVICE EXISTING MODUlAR HOME OVERALL SITE PLAN SCALE: 1~ "' 50'-0~ EXISTING UTILITY POLE EXISTING CISTERN SHED EXISTING POLE BARN EXISTING HYDRANT EXISTING TRAILER PROPOSED FENCED COMPOUND I I 1' I 1 SENSIS OVERALL SITE PLAN i -N- J JOAN P. EPPERLY 2179 23400 201 2179 23300 203 l_ JAN E. CLAYTON 2179 23200 260 JOAN P. EPPERLY 2179 23400 201 2179 23300 203 PROPERTY PLAN NTS PROPOSED SITE ~OCATIO:_}­ I I JOSHUA D. WILSON & LYNN M. JESUTIS 1 2179 23400 647 I +--·l I STEVEN SCOTI WERNER/ 2179 23400 646 I SENSIS PROPERTY PLAN ~ ~ ~ ~ G: g ' w ~ / ~ iii z w ~ a ~ ,;; iii i5 ~ ~ ~ ~ ~ ~ z a ~ ~ ' N 0 0 0 ~ ;> u ~ .E ~ 2 200' 100' 0 ~-200' t I ~~ + r Q [XIST!NG DIRT ROAD EXlST!NG GARAGE p ~EXISTING MODULAR HOM£ OVERALL SITE PLAN SCAlE: I" "' 200'-o" 263'-0"± t ~~ I r EXISTING CISTERN SHED PROPOSED FENCED COMPOUND EXISTING POLE BARN. EXISTING TRAlLER ~~ 1==---------------------------------,-------~~----------,---------------------------------------,--------------------------------------r-r----;;----------------------~~--~~--~ 499 Col. Eileen Collins Blvd. Syracuse, New York 13212 Phone 315-455·2000 Fax 315-455-9667 www.cscos.com GSI9TO'M>Alll ROAD EAST SYRACUSE, NEW YORK 130-U SITE NAME: GREENFIELD SITE LD. NUMBER: R6 260 LAZY S REVERSE S DRIVE NEW CASTLE. CD 81652 SENSIS OVERALL SITE PLAN --\ _j I I I \ 2 0 3/l 6" 1111111 IIIU\11 I I I I I EXIsnNG IJTIUTI' POLE, PROPOSED SOURCE OF ELECTRIC SEI'!VICE, SEE DETAIL / ( / I / I 6o3\ \§7 I I I I I I I \ \ \ \ \ \ \ 2 \ \ 4 \ \ \ 499 Col. Eileen Collins Blvd. Syracuse, New York 13212 Phone 315-455·2000 Fax 315-455-9667 www.cscos.com / \ \ 5 9 z 8 \------PROPOSED UNDERGROUND / J ~~TELCO SER\IICE, '\ SEE DETAIL@ " 105 '\, 06A ( I ( \ \ \ \ \ / \ \ \ \ '\_ \ PROPOSED UNDERGROUND , 7ElECTRIC SERVICE, "' SEE OITAJL@ XI " 104 06A " \ XI ' \ 'l_···x_-:-x-x-x-x_j G " !11 \ // ~\ J /7" J~;:. /'[\ ) I ...._---- \ \ / SITE PLAN PROPOSED GATE SfOP (tTYP. 2), SEE DETAI~ @ \ \ I I SCALE: 3/16" "' !'-0" 11519 TOWPATH ROAD EAST SY/tACUSE, HI:W YORK 13057 SITE NAME: GREENFIELD SITE 1.0. NUMBER: RG 260 LAZY S REVERSE S DRIVE NEW CASTLE, CO 81652 / / PROPOSED 12'-o· WIDE SWING GATE, SEE DErAIL@ @ ~~~~~ ~ ' "' N w ~ Ei ~ ~ ~ 0 'i' ~ "' ~ PROPOSED 1J:r OIA. ......-' PIPE MAST 5'-0~_.........­ LONG TOWER ELEVATION NTS \, ' b ~ I ~ "' ~ lil i5 w ~ 0 ~ "' ~ GATE POST GATE 12'-0~ PLUNGER BAR J STRANDS BARBED WIRE BOTTOM TENSION WIRE __ , TYPICAL ELEVATION EXTENSION ARMS-----, RAJL STONE /ni .,... SEE OIT~L~ \§7 CENTER ·GATE STOP EMBEDDED IN CONCRETE, SEE MUSHROOM DErAil THIS SHEET WOVEN WIRE DOUBLE SWING GATE DETAIL NOTE ~ SEE NOTES, DETAIL~ FAC!t !TY SlOE PROJECT 1M ABOVE GROUND AND SLOPE ALL AROUND (TYP) DETAIL NTS ~ ~ k CORNER, GATE. END OR PULL POST J STRANDS BARBED WIRE '---TOP BRACE RA!L _r------STRETCHER PROJECT 1M ABOVE GROUND AND SlOPE ALL AROUNO (JYP.) BAR ~--DIAGONAL ROO W/ STEEl TURNBUCKlE BDTIOM TENSION WIRE ::f~~~1 ~;~~g~=~:; FINISH GRADE 499 Col. Eileen Collins Blvd. Syracuse, New York 13212 Phone 315·455·2000 Fax 315-455-9667 www.cscos.com 6519 TOWPATH ROAD EAST SYRACUSE, NEW YORK 130S7 1 1/2 • 'fl'~<rrm" YARD, UNE POST FOOTING_/ 1'-o" SEE NOTES, DErAIL 345 NOTE' @ TYPICALSECTION 13 WOVEN WIRE FENCE DETAIL GAL. CAST IRON OR ALUMINUM GAlE DETENT SITE NAME: GREENFIELD SITE J.D. NUMBER: R6 260 LAZY S REVERSE S DRIVE NEW CASTLE, CO 81652 DETAIL NTS 6_41\ ~ SEE OET~@L 299 04A ~ DUCK BILL OPEN GATE HOLDER. V£RIFY LOCATION IN FIELD PRIOR TO INSTALLATION. ,. ' I I <1l I I I ~ ·u 00 •• DUCK BILL OPEN GATE HOLDER DETAIL (3M\ ms ~ TYPICAL WOVEN WIRE FENCING NOTES ~ ~ SENSIS FENCE DETAILS 2 6 EXOTHERMIC WELD #6 TO MG-30 BASE FRAME PROPOSED GROUNDING PLAN SCALE: 3/16" "" 1 '-a" #2 AWG GROUNO FROM PROPOSED FUTURE PROPANE TANK INSPECTION HAND HOLE COYER INSPECTION HAND HOLE EXISTING GRADE CONCRITE OR PVC #2 AWG SOLID GROUND WIRE CABLE TO ROD CAD WELD CLEAN SANO FILL GROUND ROD / \ I ~ z w w "' --·---1 INSPECTION HAND HOLE MAY BE CONCRETE OR PVC AND SHALL BE A MINIMUM OF 8" IN WIDTH/DIAMETER. GROUND ROD WITH ACCESS AREA DETAIL NTS EXOTHERMIC WELD (64U ~ RING GROUND #2 AWG sew SOLID, TINNED GROUND ROD COPPER CLAD STEEL ROD W/MIN. 5/BH\l!XtO'~O" LONG 1. ALL BELOW GRADE GROUND sYSTEM CONDUCTORS SHALL BE A MINIMUM DEPTH OF 30" (OR 6" BELOW FROST UNE. WHICHEVER IS GREATER) 2. GROUND ROD SHALL BE DRNEN VERTICALLY. NOT TO EXCEED 45 DEGREES FROM THE VERTICAL GROUND ROD DETAIL NTS (i1D ~ SENSIS NOTE:. RING /12 AWG BCW (SEE NOTE 1, SHEET 09) 1. THE 12 AWG SOUD BCW, FROM THE GROUND RING SHAll BE CADWELOEO TO THE POST ABOVE GRADE. 2. BOND EACH HORIZONTAL POLE/BRACE TO EACH OTHER AND TO EACH VER1JCAL POLE BONDED TO THE EXTERIOR GROUND RING 3. GATE JUMPER SHALL BE #2/0 AWG WELDING CABLE OR FLEXIBLE COPPER BRAID BURND'l' T'I'PE 8 WITH SLEEVES ON EACH END DESIGNED FOR EXOTHERMIC WELDING. 4. GATE JUMPER SHALL BE INSTALLED SO THAT rr Will NOT BE SUBJECTED TO DAMAGING STRAIN WHEN GATE IS FULLY OPEN IN EITHER DIRECTION. FENCE GATE GROUNDING DETAIL DETAIL 499 Col. Eileen Collins Blvd. Syracuse, New York 13212 Phone 315-455-2000 Fax 315·455-9667 www.cscos.com (6;\ \§7 Pymmid Nctwc;rk Ser\'ices, LLC 6$19 TOWPATH ROAO EAST SYRACUSE, NEW YORK 1l057 SITE NAME: GREENFIELD SITE I.D. NUMBER: R6 260 LAZY S REVERSE S ORIVE NEW CASTLE, CO 81 652 EACH STRAND OF BARBED WIRE SHALL BE CROUNOEO USING BURNDY KSU22 x ~~i~~~i~~SPUT BOLT CONNECTORS (TYP,~-~) ~~~ft~~~><--~ NOTES: GROUND RING 12 AWG BCW VERTICAL POST NOT CONNECTED TO RING 1. VERTICAL POSTS SHALL BE BONDED TO THE RING AT EACH CORNER AND AT EACH GATE POST. AS A MINIMUM ONE VERTICAL POST SHALL BE BONDED TO THE GROUND RING IN EVERY 100 FOOT STRAJGHT RUN OF FENCE. 2. HORJZONTAL POLES SHALL BE BONDED TO EACH OTHER. 3. BOND EACH HORIZONTAL POLE / BRACE TO EACH OTHER AND TO EACH VERTlCAL POST THAT IS BONDED TO THE EXTERIOR GROUND RING. 4. BOTH THE FENCE FABRIC AND BARBED WIRE SHALL BE GROUNDED AT N« AND All BREAK POINTS FENCE GROUNDING DETAIL DETAIL Q ~ SENSIS GROUNDING DETAILS