HomeMy WebLinkAbout04395INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER L.\ Co Cre, ADDRESS °- b3"3 PHONE��'�`C�-.\Sa+ CONTRACTOR C."..s C4,� m - ADDRESS Q 5 CR, ` fl J \, (.0 \ dt o PHON011\1---)c \1 U CqS C 03'.1�.a'`'A PERMIT REQUEST FOR NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: � Near what City of Town � 4 Size of Lot YS L „C)1 o\ Legal Description or Address 11\-1 -S�c����1 \\ 1tS l R(31-1 WASTES TYPE: ( ) DWELLING ( ) TRANSIENT USE N. COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER—DESCRIBE BUILDING OR SERVICE TYPE: Qi> tm wi TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER -DESCRIBE FINAL DISPOSAL BY: ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER -DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes lb per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Name, address and telephone of RPE who made soil absorption tests: 1Z.S6la,A19,A`1.... Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluatin g the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed( -?1J -\.v ` V �� � Date i` a\1� PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!! 3 Dec 28 07 11:55a Joseph Tikos 9378988292 p.1 PO Bar 2844 Sei.: Ytr , GE enwood Springs, CO 81602 Ph970-61&3033 NC[ Fax 303-216-2796 December 27th, 2007 Phil Vaughan Construction Management C/o Phil 1038 County Road 323 Rifle, CO 81650 Installation Observation, Proposed Office Highway 6 and 24, East of Rifle, Cascade Tanks Garfield County, Colorado Project No. 1421 Mr. Vaughan, ALL SERVICE septic, LLC performed an installation observation on December 19`x' 2007 for the subject property. The installation included a 1000 -gallon, two-compartment precast concrete septic tank with an effluent filter, followed by 2 rows of 12 `Quick -4' chambers, for a total of 24 chambers, equaling 237 SF of drain field. Effluent is distributed with a concrete distribution box. The OWS was installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWS. LIMITS: The observations were based on information submitted. If conditions are different from conditions described in this letter, ALL SERVICE septic, LLC should be notified. All additional OWS construction must be according to the county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SCE septic, LLC Timo#hy R. Petz 3 copies sent Copy sent to Garfield County s[og[ PO Box 2644 Glenwood Springs, CO 81602 Ph 970-6185033 Fax 303-216-2796 November 19, 2007 Project No. 1421 Phil Vaughan Construction Management Attn: Phil 1038 County Road 323 Rifle, CO 81650 Subsurface Investigation and Onsite Wastewater System Design, Proposed Office Building Cascade Tanks State Highway 6 and 24 Garfield County, Colorado Phil, ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater system (OWS) design for the subject office building. The property is located outside of Silt Colorado, in an area where OWS are necessary. SITE CONDITIONS The project area is located north of Highway 6 and east of County Road 210. An office building is proposed as indicated on Figure 1. The project area is relatively flat with no vegetation. The proposed office will have approximately 1400 SF. SUBSURFACE The subsurface was investigated by digging one profile pit and three percolation holes, as indicated. The materials encountered in the profile pit consisted of 1 -foot of road base, underlain by sandy clay to 8 feet. Groundwater or bedrock was not encountered. Three percolation holes were dug, in the area of the proposed drain field, as indicated. Percolation rates ranged from 27 to 40 minutes per inch (MPI). A 32 MPI rate will be used to design the OWS. DESIGN SPECIFICATIONS The OWS design is based on a 12 persons office building and an average sewage load of 240 GPD. The installation must include a 1000 -gallon, two-compartment, precast concrete septic tank with an OrencoTM Biotube 4 -inch diameter effluent filter, followed by two gravelless trenches. Each trench must have 12 `Quick -4' chambers for a total of 24 chambers, equaling 237 SF of infiltrative area. Subsurface Investigation and OWS Design Project No. 1421 11/19/07 Page 2 Tank alternatives may be considered. A concrete distribution box with a baffle must be installed to distribute effluent. Construction must be according to the county ISDS regulations, the septic permit provided by Garfield County Environmental Health Department, and this design. OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo - fabrics or plastics should not be used over the drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWS. For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years and clean the effluent filter as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWS. No hazardous wastes should be directed into the OWS. Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC, and the county must view the OWS during construction. The OWS observation should be performed before backfill, after placement of chambers and distribution pipes. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. Subsurface investigation and OWS Design Project No. 1421 11/19/07 Page 3 LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE se ' LLC Timothy R. Pe 3 copies SITE PLAN AND LOCATION OF PERCOLATION HOLES N 00°33'18' E Exemption Parcel 7.676 Ac. N 89°26'4T W 694.04' PROPOSED OFFICE MODULAR 60.0' S 89°48'53" E 1054.81' GMCO Parcel 36.011 Ac.± c SOO Proposed 'Vx3\ �q I 60"X80' Structure RPR FILE PIT I DP -1 \\ DP -2 \N. N. DP -3 PROFILE PIT AND PERCOLATION HOLES 1 THROUGH 3. N 89°43'20" W .\ Existing Access 1 Existing Structure SCALE 1" 200' NORTH 0 I Yard Area ti +D 00 S 00'27'30" W —1 �_1 I -' y, 1 �� \ LL -JI LI 2000.45' CASCADE TANKS HIGHWAY 6 AND 24 GARFIELD COUNTY, COLORADO ALL SERVICE SEPTIC, LLC 970-618-5033 PRO. NO. 1421 FIGURE 1 Center- Corner Sec. 11 Brass Cap L.S. No. 9009 in Place PROPOSED OWS _ SCALE 1" = 40' NORTH PROPOSED OFFICE BUILDING (SUBJECT BUILDING) \ 4" SDR 35 OR------- SCHED 40 SEWER LINE 1000 -GALLON, TWO-COMPARTMENT, PRECAST CONCRETE SEPTIC TANK WITH 4" ORENCO(tm) EFFLUENT FILTER ON OUTLET (SEE DETAIL) /CLEANOUT 4" SDR 35 HEADER LINES 0 6' MIN L TME LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. DRIVE PROPOSED BUILDING CONCRETE DISTRIBUTION BOX WITH BAFFLE LU Z LU LL TWO GRAVELLESS CHAMBER TRENCHES WITH 'QUICK -4' CHAMBERS. EACH TRENCH HAS 12 CHAMBERS FOR A TOTAL OF 24 CHAMBERS EQUALING 237 SF OF INFILTRATIVE AREA. OBSERVATION PIPES CASCADE TANKS HIGHWAY 6 AND 24 GARFIELD COUNTY, COLORADO ALL SERVICE SEPTIC, LLC 970-618-5033 Project No. 1421 FIGURE 2 DESIGN 12-PERSONS/DAY OFFICE BUILDING LOADING = q = 240 GALLONS/DAY @ 20 GALLONS/PERSON PERCOLATION RATE = t = 32 MINUTES PER INCH (MPI) CALCULATED AREA = ((1.5 X q X sqrt t) / 5) = 408 SF PROPOSED AREA = 408 SF X 50% REDUCTION = 204 SF TRENCH SPECIFICATIONS WIDTH OF TRENCHES = 3 FEET =1 CHAMBERS LENGTH OF 'QUICK -4' TRENCHES = 48 FEET = 12 CHAMBERS TOTAL NUMBER OF 'QUICK -4' CHAMBERS = 24 TOTAL INFILTRATIVE AREA = 237 SF TWO TOTAL TRENCHES DRAIN FIELD CROSS SECTION - TYP. I 3.0' MAX 4" PVC OBERVATION PIPE LIMIT OF EXCAVATION GRAVELLESS CHAMBER (4'x3) t -o-6' MIN -�/� f SCARIFY SURFACE 2.0' MIN SWEEP / 2 WAY CLEANOUT DETAILS (N.T.S) TYPICAL INFILTRATOR(R) QUICK4(TM) CUT SHEET 52' 48' (EFFECTIVE LENGTH) INLET AND OUTLETS INTO TOP PORT OF END PLATE PLAN VIEW - TYP. 4" PVC INLET CONCRETE /DISTRIBUTION BOX WITH BAFFLE 4" PVC HEADERS PROJECT NO. 1421 GRAVELLESS CHAMBER 'QUICK -4' 12 CHAMBERS PER TRENCH 12 CHAMBERS PER TRENCH j i) 3�FEET 6 FEET MJ 1 OBSERVATION PIPE FIGURE 3 1000 -Gallon (min), 2- Compartment Septic Tank with 4" Dia. Biotube® Effluent Filter PVC or Concrete Risers with Grommet(s) (bond to tank adapter with recommended adhesive) Slope Ground Away From Risers Inlet Tee ALARM IS OPTIONAL Patents # 4,439,323 & 5,492,635 Foreign Patents Pending © 2002, Orenco Systems, Inc. Conduit to - r, Alarm Panel Conduit Seal 2a Liquid Level COPELAND TANK CNETER PORT ACCEPTABLE ALTERNATIVE TO PVC TEES r7 High Level Alarm Float (optional) PVC Splice Box w/Cord Grips Fiberglass Gasketed Lid with Stainless Steel Bolts Filter Cartridge Handle (field cut to desired height) Tank Adapter (cast or bolted) Vent Orifice Effluent Discharge Modulating Discharge Orifices Vault Inlet Ports Filter Cartridge Effluent Filter PROJECT NO 1421 Percolation Test Results for Cascade Tanks Garfield County Project No. 1421 PROFILE PIT INFORMATION ' ALL SERVICE septic, LLC 970-618-5033 uJ W LL a W 0 10 PROJECT NO. 1421 PROFILE ROADBASE, SANDY CLAY, SANDY, STIFF, MOIST, BROWN TO LIGHT BROWN, NO GROUNDWATER ENCOUNTERED DURING DIGGING OR WHEN CHECKED ON NOVEMBER 2, 2007 GARFIELD COUNTY ENVIRONMENTAL HEALTH DEPARTMENT Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1421 PROFILE PIT 0 - 1' Road Base Material (fill) 1' - 8.0' Clay, Sandy, M. Stiff, Moist, Brown/L. Brown Date of Test: 11/02/2007 No Groundwater or Bedrock was Encountered Hole Hole Interval Measurement at Measurement at Change (in.) Percolation Rate No. Depth (in.) (min.) Start of Interval End of Interval (min.lin.) MPI (in.) (in.) 1 33 20 2.50 4.00 1.50 20 4.00 5.00 1.00 20 5.00 6.00 1.00 fill 20 6.00 6.50 0.50 20 6.50 7.00 0.50 20 7.00 7.75 0.75 2 37 20 1.75 3.25 1.50 20 3.25 4.00 0.75 20 4.00 5.00 1.00 20 5.00 5.75 0.75 20 5.75 6.50 0.75 20 6.50 7.25 0.75 3 39 20 2.50 4.00 1.50 20 4.00 5.25 1.25 20 5.25 6.00 0.75 20 6.00 7.00 1.00 20 7.00 7.75 0.75 20 7.75 dry AVG =32 MPI 40 27 27