Matt — The following is clarification for the work being done by Simms Construction on the Hill Residence west of Rifle.
1. On sheet S2.2, the revised condition is acceptable on Grid Line 2 (at the roof over the Garage) where the wood beams on the steel beam with 3-2x6
column.
2. The OSB sub -floor is acceptable as a substitute for noted plywood sub -floor.
3. The substituted 2x10 ledger at the entry deck along Grid 5 is acceptable for the 2x12 called out on sheet S2.1.
4. The substituted 2x8 ledger at the entry deck along Grid B is acceptable the 2x12 called out on sheet S2.1.
5. The substituted 2x10 ledger at the entry deck along Grid 2 is acceptable for the 2x12 called out on sheet S2.1.
6. The 4x4x1/4x8" long angles with 4-3/4"x7 thru bolts at each face at the beam -beam connection on Grid 4 (between D and E) and Grid 5 at the
window header (between D and E) are acceptable, revised structural connections on sheet S2.2.
7. The PVC waste lines are acceptable substitutes for the cast iron called out in the general notes.
If you have any more questions, please let me know.
Best Regards,
Bruce Barth Architect+Contractor
Red House Architecture/design+build
815 Blake Avenue
Glenwood Springs Colorado 81601
970 945 8240 - t
866 431 1950 - f
970 618 1499 - c
www.redhousearchitecture.com
"Life shrinks or expands in proportion to one's courage."
- Anais Nin
Information from ESET NOD32 Antivirus, version of virus signature database 5008 (20100407)
The message was checked by ESET NOD32 Antivirus.
http://www.eset.com
file:///Cl/Users/lkrol/Desktop/Hill%20Residence.htm[12/21/2017 10:53:38 AM]