HomeMy WebLinkAbout08.0 Director's Determination 08.17.2017Garfield County
August 17, 2017
David Rasmussen
826 Highway 133, Suite C
Carbondale, CO 81623
Reference: Administrative Review Minor Subdivision — Mountain Shadow Place
Garfield County File Number MISA-05-17-8547
Dear Mr. Rasmussen;
This letter is provided to you, as the authorized representative for Garfield County File
MISA-05-17-8547, pertaining to a Minor Subdivision of a parcel owned by Western Slope
Welding, LLC with Parcel ID 211934300006. This letter is notification that your request
for subdivision has been reviewed by the Community Development Department and the
Director hereby issues a determination conditionally approving the request. The
conditions of approval are as follows:
Conditions Prior to Signature of the Plat
1. The Applicant has 90 days within which to satisfy applicable conditions of approval
and provide the following documentation for BOCC signature and recordation:
a. A plat mylar with signed Certificates that include Dedication and
Ownership, Title, Taxes, Surveyor, and any mortgagees.
b. The following amendments shall be made to the plat prior to obtaining
signatures. This updated plat shall be provided to and reviewed by the
Community Development Department prior to creating a Mylar copy of
the plat and obtaining any signatures.
j 1.
The name and address of the surface owner and mineral
owners shall be shown on the plat.
A black and white Vicinity Map shall be added to the plat.
The setback lines shall be removed from the plat.
1
J
iv. The Certificate of Dedication and Ownership shall be
updated to match current form.
•v. The County Commissioners Certificate shall be updated to
match current form.
vi. The following plat note shall be added to the plat: No
further subdivision of the parcels within Mountain
Shadows Place Minor Subdivision are permitted by Minor
Subdivision, as defined in the Land Use and Development
Code of 2013, as amended.
LL vii. A line to fill in the Book and Page for the proposed Codes
Covenants and Restrictions shall be added to the plat.
viii. Include the annotated distance from the Southeast corner
of Lot Two to the nearest property corner.
ix. The parking easement graphic designation for the
westernmost parking space for Lot 3 is not consistent with
its label. The graphic designation of the westernmost
parking space for Lot 3 shall be corrected to be consistent
with its label.
x. The following plat note shall be added: "Current and future
owner(s) should be made aware of the potential for
sinkhole development, since early detection of building
distress and timely remedial actions are important factors
in reducing the cost of building repairs should an
undetected subsurface void start to develop into a sinkhole
during or after construction."
c. Recording Fees.
) Prior to the BOCC signature on the Plat the Applicant shall provide the school
impact fee, payment in -lieu of school land dedication. The school impact fee shall
be in the amount of $13,680.54.
Prior to the BOCC signature on the Plat the Applicant shall provide an explanation
of the provided cost estimate and explain why the storm drainage, road
construction, and erosion control were not included. This explanation shall be
reviewed and accepted by the Community Development Department and County
designated engineer. Should it be determined that additional improvements need
to be included in the cost estimate due to this review or any other required
improvements for determination of the financial security, then the Applicant shall
revise the cost estimate to the satisfaction of the County Attorney, County
designated engineer, and the Community Development Department.
4. Prior to the BOCC signature on the Plat the Applicant shall complete the
.Subdivision Improvements Agreement (SIA). The SIA shall be in final completed
rjn form prior to scheduling the document for Board signature. The SIA shall be signed
by the Board in a public meeting prior to Board signature on the Mylar plat. The SIA
2
shall be reviewed and accepted by the County Attorney's Office and Community
Development Department, with all edits completed and signed by the property
owner, prior to scheduling the SIA and Mylar plat for signature with the Board.
5. Prior to the BOCC signature on the Plat the Applicant's engineer shall evaluate the
11 e.) applicability of the drainage infrastructure for the 25 -year storm. This evaluation
Lf
J(' `• shall be reviewed and accepted by the County designated engineer and Community
\Y Development Department.
6. Prior to the BOCC signature on the Plat, the below measures shall be incorporated
into the CCRs for the development, as recommended by Colorado Parks and
Wildlife. Such measures are to help eliminate animal attractants.
a. All residents shall use bear -proof trash containers, or create a bear -proof
centralized trash pick-up location.
b. Encourage new residents to follow "bear aware" practices including:
feeding pets indoors and storing pet food indoors, cleaning BBQ grills
after use, removing bird feeders during summer months and/or at night,
only placing trash out on morning of pick-up, not composting food waste
v outside, etc.
Ler! j c. Prohibit fruit, berry, and nut producing trees and shrubs from
%
,, Cu
.ti1
landscaping plans.
k
tr'` . 7. Prior to the BOCC signature on the Plat an analysis for the turning movements of
'c CU.� the fire protection equipment on the driveway shall be reviewed and accepted by
j _,, p y I,► lie Glenwood Spring Fire Department.
v 8 Prior to the BOCC signature on the Plat the turnaround for the fire protection
1'a quipment on the driveway be reviewed and accepted by the Glenwood Spring Fire
'» -' °''Department.
A
9. Prior to the BOCC signature on the Plat the driveway width shall be reviewed and
,� k , accepted by the County designated engineer, Glenwood Spring Fire Department,
17 &‘' and Community Development De artment.
10. Prior to the BOCC signature on the Plat the Applicant shall provide more information
�,\AV on the driveway surface material and provisions that are proposed to be taken to
1,\- ensure that the surface will hold up over time and in varying weather conditions
Lt'1 given the grade. This information shall be reviewed and accepted by the County
designated engineer, Glenwood Springs Fire Department, and Community
Development Department.
11. Prior to the BOCC signature on the Plat the Applicant shall provide a description of
the winter maintenance that will be performed and an analysis of whether a guard
/ rail is warranted. This information on winter maintenance and analysis of whether
a guard rail is warranted shall be reviewed and accepted by the County designated
3
engineer and Community Development Department.
12. Prior to the BOCC signature on the Plat the Applicant shall conduct a geotechnical
investigation of the property and follow the recommendations made by the Colorado
Geological Survey (CGS). This geotechnical investigation shall be reviewed and
accepted by the County designated engineer and Community Development
Department. The Applicant shall comply with all recommendations of the
geotechnical investigation. The requirements for the geotechnical investigation, as
described by CGS are as follows:
Hydrocompaction and subsidence due to dissolution of gypsiferous
material. The site soils are derived from and underlain by, at an unknown
depth, Eagle Valley Evaporite containing the soluble minerals gypsum,
anhydrite, and halite. The surficial debris fan deposits are likely to be loose,
low density, low strength, and hydrocompactive, meaning they can lose
strength, settle, compress, or collapse under loading and/or when water
infiltrates the soils. Thick columns of compressible or collapsible soils can
result in very significant settlement and structural damage. Sinkholes,
subsidence, ground deformation and settlement due to collapse of solution
cavities and voids are active processes in the Roaring Fork Valley, and are
an unpredictable risk that should not be ignored.
• Lot -specific geotechnical investigations consisting of drilling,
sampling, lab testing and analysis will be needed, once building
locations have been identified, to: determine the thickness and
extent to which the soils beneath each proposed structure are
subject to settlement or collapse under loading and/or wetting;
characterize soil and bedrock engineering properties such as
density, strength, water content, swell/consolidation potential and
bearing capacity; determine depths to groundwater, bedrock, and
any impermeable layers that might lead to development of a perched
water condition; determine the feasibility of full -depth basements, if
planned; and provide earthwork, foundation, floor system,
subsurface drainage, and pavement recommendations for design
purposes. It is imperative that grading, surface drainage, and
subsurface drainage are correctly designed, constructed and
maintained to prevent wetting of potentially collapsible and
expansive soils surrounding foundation elements.
• If conditions indicative of subsidence or sinkhole formation are
encountered during site investigations or construction, an alternative
building site should be considered or the feasibility of mitigation
alternatives should be evaluated.
• Techniques such as engineered, rigid foundation design, geotextile
ground reinforcement, and/or strain isolation trenches should be
4
considered to reduce subsidence -related risks.
Other Conditions
13.AII representations of the Applicant within the application and public hearing shall
be considered conditions of approval unless otherwise modified by the Board of
County Commissioners.
14. All exterior lighting shall be downcast and shielded and comply with Section 7-304,
Lighting Standards, of the Land Use and Development Code of 2013, as amended.
15.AII Tots within the development shall be served by City of Glenwood Springs water.
The property owner(s) shall comply with all requirements from the City of Glenwood
Springs for connection to the municipal water system.
16.AII lots within the development shall be served by the West Glenwood Sanitation
District for wastewater. The property owner(s) shall comply with all requirements of
the West Glenwood Sanitation District for connection to the District's wastewater
system.
17.AII residential buildings shall have fire sprinklers installed prior to issuance of the
Certificate of Occupancy.
18.AII residential buildings shall be constructed using Radon Resistant New
Construction (RRNC) standards.
19. Building/foundation design and locations shall comply with the geotechnical
investigation required to be conducted by Condition number 12, above.
Notice of this decision will be provided to the Board of County Commissioners who has
the ability to `call-up' the application for review at a public hearing. You will be notified of
the Board decision once it is received or upon expiration of the 10 day notice period.
Feel free to contact myself or David Pesnichak, the staff planner, if you have any
questions regarding this decision.
Sincerely,
She ,'1 wer, AICP
Dire or of Community Development
Attac ment
Cc: BOCC
5
PNAL PLA'
MOUNTAIN SHADOW SUBDIVISION
BEING SITUATED IN SEMS WJL of SECTION 34, TOWNSHIP 5 SOUTH, RANGE 39 WEST, 6TH P.M.
COUNTY OF GARFIELD, STATE OF COLORADO
•
JAC
.EYEKn MAE. EVEIKIele, ...K_7, E•lEld•Vr
AREA -
SOPRIS ENGINEERING - LLC
MAIN
STREET.
T EE.sn n
5PEFT.SURE43
URB MNM 111 So r..1 5OBLQ3
VVLSTFRN HIL15 SUBDIVISION
LEGEND
1-1
1
NORTH
.111.411.