Loading...
HomeMy WebLinkAbout1.01 Plat Maps..FINAL PLA 7-7 SU BAIITTA_L PREPA ?E_D BY.• OWNER/APPLICANT PL1VNER: PMENT.� _SCHMUESER GO DON MEYER INC._ CARBONDALE LAND DEVEL O C ORPORA TION CIO SCOTT WRITER 1001 GRAND AVENUE SUITE 2-E -- - P.O. BOX 9705, ASPEN, CO. 811-2 #GLENWOOD SPRY°NGS, COLORADO- - - -------- TELEPHONE: 920-4477 81601 (JOJ) 945 1 04 - _ „1 , - — _ 3 _ - = l� z - ; ._ { : S=am—" y`. • 4 ya ENGINEERS �'' -- -2 SURVEY S _ OR 28� a • 1 / J — - 7.e % Su tank:•''. RAVER SHEET INDEX I i i \ 1 __ �__�.• SCHMUESER _ `-•• GORDON MEYER -- - , ------ - ------ -' - ----------- -- - - - - CO VER SHEET j--' 1 ROAD PLAN VEGETATION & T OGRAPHY IVAP °` •� ' _ ----•. � 1 wll 33 WA Y PROFILE w °� 35 2 ROAD � -t� ••. 1 .��,. - - .T �'wL���.NCarbondale 3 DRA INA GE PLANS �` I I I O� SBM I t�,1 I ________-------�T----A----_—_—WNW _— - 4 UTILITY PLAN -- --� -- =r_ _ i 5 WATER DETAILS PROJE T ENG/NEER.• VICINITY 6 WATER DETAILS I MAP 7 TYPICAL ABSORPTION SYSTEM l DEAN W. GO00N .P. )- 0 E. , 145D7 o ' `Gd _-c o' I 1 ^ T e L s� SCHMUESERTo N 19'433 N 61'29'0: S 28'38' 1 S 80'5011 N 31'04'1 N 20'54 3 N 69'53'2 N 77'26:3 N 85'02'C S 83'03'4 N 10'182 LEGEND 3) LOT NUMBER & POTENTIAL BUILDING LOCATION PERMITTED WELL (NOT DRILLED) A ACTIVE WELL LOCATION PUMP HOUSE_ LOCA77ON - i jr I BU/LD/NGS A \ 64&1i LOT i9 fi 3048 AC..tHARRIS-,".7�j r F 6040,59 4"- f, i�4.232 ACf �.�� - 21 GENERAL NOTES: I) 1) TOPOGRAPHY LINES & EXISTING CONDITIONS TAKEN FROM POWERS MAP DIGITIZED FROM MAP PREPARED BY RE -105 AERIAL MAPPING, 1580 CHESTER STREET, AURORA, COLORADO. OCT. 1991. 2) REMOVE ALL VEGETATION AND PLANT MATERIAL AS WELL AS TOPSOIL, STOCKPILE TOPSOIL FOR REPLACEMENT ON CUT AND FILL SLOPES. 3) SCARIFY EXISTING SUBGRADE PRIOR TO CUT/FILL OPERATIONS SCARIFY TO A DEPTH OF 6" AND RECOMPACT. COMPACT ALL SUBGRADE MATERIALS 1N MAXIMUM 8" LOOSE LIFTS TO 95X STANDARD PROCTOR AT ±2X OPTIMUM MOISTURE CONTENT. 4) NO IMPORT SUBBASE MATERIALS WILL BE REQUIRED OVER THE BULK OF THE ROADWAY. USE MAXIMUM 6" MATERIAL IN ALL BACKFILL. AFTER EARTHWORK OPERATIONS ARE COMPLETED, PROOF -ROLL ALL EXIS77NG PREPARED SUBGRADE SURFACES AT DIREC77ON OF ENGINEER, REMOVE ALL SOFT AREAS AND REPLACE WITH IMPORTED CLASS 2 SUBBASE MATERIAL. 5) CONSTRUCT ROADWAY STRUCTURAL SEC77ON AS SHOWN IN TYPICAL SECTION SHEET 3 OF 8. 6) BASE COURSE MATERIALS TO BE CLASS 6, COOH SPECIFICATIONS. 7) CHIP/SEAL SURrACING TO CONFORM TO CDOH SPECIRC417ONS FOR PI ANT MIX .SF41 ('DAT /SFCTION 409). USE AGGREGATE SIZE OF J14'- 8) REVEGET477ON OF ALL DISTURBED SURFACES TO CONSIST ~� OF REPLACEMENT OF MINIMUM 4" TOPSOIL AND HYDRO- —+ SEEDING OR SEEDING/MULCHING WITH A NATIVE SEED MIX. SUBMIT MIX DESIGN, FERTILIZATION APPLICATION AND MULCHING APPLICATION TO ENGINEER FOR APPROVAL. SCALE.' 1"= 100' 9) FIELD DETERMINE NEED FOR RIP -RAP OF DRAINAGE DITCHES CONTOUR INTERVAL 2' 9X• AND OVER. RIP -RP TO BE 9" DIAMETER. 10) PLACE 1 C. Y. OF 9" RIP -RAP AT OUTLET OF ALL CULVERTS. RIP -RAP TO BE HAND PLACED TO A DEPTH OF 9" AND WIDTH OF 4' 11) PROVIDE FOLLOWING SIGNAGE CONFORMING TO UNIFORM MANUAL ON TRAFFIC CONTROL DEVICES, A) STOP SIGN AT C.R. 103. B) THREE (3) 25 MPH SIGNS TO BE FIELD LOCATED. ENGINEERS SCHYU° '? GORDON MEYER INC. SURVEYORS 1001 GhMoENUE, SU/TE 2-E COLORADO 81601 (.303) 94,':774 (FAX) 945-5948 ASPEN, COLLO (303) 925-6727 r WOODEA/ DEERSU�3DIV, REVISION DATE BY ROAD PLAN � VEGETA TION & TOPOGRAPHY MAP Job No. 91147 ZoF7 TURN-AROUNDS CISTERNS 25 92 RM Drown by: RM FF D ROADWAY WIDTHS & ENTRANCE RADIUS 4 08 92 RMGLENWOODDINGS. Date. 1/21/92 VAL FOR CONSTRUCTION 918192 RM D Name. DWG a. / 6760 6 740 6,720 6700 6680 SCALE 1'= 100' HORZ. 1"= 20' VERT. 6660 6640 6620 6600 6580 e 6560 2 v EXISTING GRADE- 1 FINISHED GRA, I Ln tr Ln b cn (p (n cp (n tp tp b b (O C£NTERUNE ROAD STATIONING 31+00 32+00 33+00 34+00 35+00 36+00 37- 38+00 39+00 6460 q IN N cc c vv cbo o W 0 b cbo (bo (bo 1c) to 40+00 41+00 42+00 43+00 -150'- vc - rn cO � b C£NTERUNE ROAD STATIONING o h q O 0b 6780 II J 6440 200' VG' Uri 11 U eb h O 11 1 00% (o o W U �J. 6540 FINISHED GR4DE ELEVATION (TYP.) h i n�. W w e W> W k ��- _-_-- 60' ROAD & U77UTY EASEMENT(N.T.S.) mE^ r 6520 coo -- -�� vc--- Ln r;cp0 'ry !dam e I -- ----_ `� v EXIST".'C GRADE - o h r 4 N 7 ?00' VC p a^ w h N m aj o ad p^ V 6760 O �, 24' ---- •- I 2' 10' 10'2' 3• ---- 3• o, n w d� " �0 6420 o I u i,5•42g � •� n o rn ry o rn c^o (o s i W W, ,. I HL EASEMENT H 1 4 PVI STA = 0+70.00 P14 ELEV = 6358.80 b (� e U a0 :o a r� � ,d �n`� Tb^ N h bIN `� ^ 00% N. Ii. 11 II 11 ) i I 1 20, VC w� , � ® I o 0. V b p u e 4, ^ p > Q W 20+00 6740 \-120 DEEP DITCH W/ 2: 1. SIVE \ - 3/4" CHIP &SEAL SURFACE p oo 22+00 m 23+00 2 24+00 q X " �^ �" 25+00 W 26+00 W o � L" L" 00� SLOPES AROUND PREPARED NA 77 4- CLASS 2 / 4" CLASS 6 12" DEEP (bnhj STA = 5+03.92 II '� > U U IR o W 0. k12' ^ O� CUL-DE=S.4C SUBGRADE (95% OR 8" CLASS 6 AGGREGATE DITCH PROCTOR DENS/TY) BASE �' PN PVl E: -EV = 6402.19 0 e W J > 0.a > �uW U �> I U ^co "�N (TYPICAL) COURSE AS DETERMINED BY ENGINEER /N FIELD o �, m m - � ^ � � � Iv 6720 + h °CIO 100' vcm ��� 2 - �, ___ -2.36% o(u +� 24' ROADWAY TYP. SECTION t,\o b CZ)O N� mm Lu 6,360 ® [u II cu SCALE.. 1"= 5' Ooh O "i rn(6 o +4 q a ® It Q� oW oQJ 6700 TSA 0+20 30" ") 001. Ur`) W S �z W W _ --__-- --- -- -- 60' ROAD & UTILITY EASEMENT 4 W,, I e 0 W 4� 4a / h o ^ o 0 1°0' VC 6680 2°' I 2' 8' - 8' —.-- 3 HL H 3 1 v) iI —�-- EASEMENT I 3% 6340. UO OO N Ob 600 v O n o O O O r.. n b ,•) Qj W o `r ,. n a ?) �) _ �. n'm Ln� 0 b m N O �r N o cc O n �r co O v -� o 7 tl a O r ? b :, a n (V n O b ,.n O rn h ,n O v (� h N m O O ,o � a. N W D V J _ R) .� b h o O.Ln O h o n '�) (O CENTERLINE ROAD STATIONING Op h .," b M b b "� �' ,. ^ "� err) 3/4" CHIP & SEAL SURFACE ai M I O�j M r.� w -' h =' ^'� cp p M �.o ch b 7 ,L QZ 6j (p (p M q (p EXISTING GRADE ELEVATION (TYP.) �% a+ moi- �l ') ? -r 6660 / I PREPARED NAI71/E -/ 4" CLASS 2 / 4" CLASS 6 12" DEEP -J i 'V7 d- <t c r�� .: - r; r d v b (p I� SUBGRADE (95% OR 8" CLASS 6 AGGREGATE 917C`/ V 7 rl)(a) I II (p c0 q tp �O tp cn RIVISHED GRADE ELEVATION (TYP.) (o (p (o (Q tp b ,`.. b PROCTOR DENS/TY) BASE COURSE AS DETERMINED BY ENGINEER IN FIELD W$ W cp (p cO n n b cu b :n b �' b `ll b Y b 'U (p co cp ;o tp (o c0 co `� b b 6640 20' ROADWAY TYP. SECTION co b b 0.� U �� 1+00 �,^ 2+00 '� ^ vn 3+00 '`n h 'v O (r �(V h (vy� b r Q� n� - O N c"% N v)� ) .^ v a 1q b r` V Q7 v N `.h o) ter\ n b y o 16+00 17+00 18+00 W 19+00 n co ^ lG b :�: n n (� O n - T .D n O N .. (�. O7 a p o N $ n O Q i \ W � - ' cv �; j N Q �) r, (6 rn ,..� Q in v /..: �µi d• SCALE 1-= 5• 100 VC (n to .v b �.0 (p (o b , ;v b .i, b co b (0 N b (o r\ b ( ^ b (n b u; b u� b cn tp Lo b (o 44+00 45+00 46+00 47+00 48+00 49+00 50+00 51+00 52+00 53+00 200' VC IN N cc c vv cbo o W 0 b cbo (bo (bo 1c) to 40+00 41+00 42+00 43+00 -150'- vc - rn cO � b N V 6460 6440 6420 6400 6.380 SCALE.- 1 "= 100' HORZ. 1"- 20' VERT C£NTERUNE ROAD STATIONING o h q O 0b ry II J 6440 200' VG' Uri 11 U eb h O 11 1 00% (o o W , �J. 6540 FINISHED GR4DE ELEVATION (TYP.) h i n�. W w e W> W k mE^ r 6520 coo Ln r;cp0 'ry !dam e `)oma, h^ v EXIST".'C GRADE - o h r 4 N 7 b- p a^ w h N N rn^ a^ p^ a^ cp W vR r7 �b eblbb o, n w d� " �0 6420 o I u i,5•42g � o ^ 6500 co rn a C1 o a ori o � o �O LO 4%, �r (oO (o 0 u)O of � o �.� 'n^ (C 4 PVI STA = 0+70.00 P14 ELEV = 6358.80 b (� e U a0 :o a r� � ,d �n`� Tb^ \-FINISHED GRADE vz �� 20, VC w� , � ® I o 0. 00 \` / 0 �� to �� 20+00 6400 O p oo 22+00 m 23+00 2 24+00 +S 25+00 26+00 27+00 28+00 29+00 (bnhj STA = 5+03.92 '� ^ O� p (� �' PN PVl E: -EV = 6402.19 0 6380 e W Jf3) oc" k 1 0 + h °CIO ��� 2 o(u r LQ Cq In t,\o b N� mm Lu 6,360 ® [u o cu +4 q J TSA 0+20 30" ") CMP ® 1% Z 160' VC DATUM ELEV TA. + ELEV. 6355 00-t v) iI —�-- 6340. UO OO N Ob O b v O n o O O O r.. n b ,•) Qj W o `r ,. n a ?) �) _ �. n'm Ln� 0 b m N O �r N o cc O n �r co O v -� o 7 tl a O r ? b :, a n (V n O b ,.n O rn h ,n O v (� h N m O O ,o � a. N W D V J _ R) .� b h o (O cG M Op h .," b M b b "� �' ,. ^ "� err) ai M m m a a M r.� M (.� M O�j M r.� w -' h =' ^'� cp M �.o ch b 7 ,L QZ 6j (p (p M q (p O 7 p O O w e} �% a+ moi- �l ') ? -r -- 7 -t h cv �r 'V7 d- <t c r�� .: - r; r '��n v" h a (O h °�. (p I� ^O V rl)(a) (o (p c0 tp in tp �O tp cn (p (o (p (o (Q tp b ,`.. b (p cp (p cO b u (p (c b cu b :n b �' b `ll b Y b 'U (p co cp ;o tp (o c0 co `� b b co b b 0+00 1+00 2+00 3+00 4+00 5+00 (i+ 7+00 8+00 9+00 10+00 - 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 N V 6460 6440 6420 6400 6.380 SCALE.- 1 "= 100' HORZ. 1"- 20' VERT C£NTERUNE ROAD STATIONING o h q 6560 0b ry II J Uri 11 U eb 0%f (o o W , �J. 6540 FINISHED GR4DE ELEVATION (TYP.) II ,!.;z W w mE^ r 6520 coo rnV •-.- r;cp0 'ry !dam e `)oma, h^ v EXIST".'C GRADE - o h r 4 N o pj oo p a^ w h N N rn^ a^ p^ a^ cp W vR r7 �b eblbb o, n w d� " �0 ro a� '4j o Gli Q 0 i,5•42g � o ^ 6500 co rn a C1 o a ori o � o �O LO 4%, �r (oO (o 0 u)O of � o �.� 'n^ (C 4 .� �i b (� co �V r� "i .i a0 :o a r� � ,d �n`� - O \-FINISHED GRADE vz �� �b w� Lo 6480 N V 6460 6440 6420 6400 6.380 SCALE.- 1 "= 100' HORZ. 1"- 20' VERT C£NTERUNE ROAD STATIONING EXISTING GRADE ELEVATION (TYP.) .6360 / FINISHED GR4DE ELEVATION (TYP.) 6340 rnV •-.- r;cp0 nh `)oma, o h r o IN a N o pj oo p a^ w h N N rn^ a^ p^ a^ cp W vR r7 �b eblbb o, n w d� " �0 ro a� '4j 7 o b v� (O 0 rn d 0 � �o, � a �� co rn a C1 o a ori o � o �O LO 4%, �r (oO (o 0 u)O of � o �.� 'n^ (C � �N .� �i b (� co �V r� "i .i a0 :o a r� � ,d �n`� - O [40 �b vz �� �b w� Lo �o w� �� it �� w� (D �� to �� 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 SEE OUAD MAP FOR BASIN BOUNDARY BEYOND TOPOGRAPHY J O m 2 0. �*4'*PC 0. 112 0(25) _ 0(100) _ 0 J O W PC /IPC _ P5 -5) 2 sto 0 PC ,x'12 � 0('25) 0(100) = 18 CFS = 34 CFS = _ _l04 ROAD � ? Cf5 6(tt10) = 4 CFS 6511 % ; = 3 0(100) — 6 CFS' CFS r PC 2 0(25) = 2 CFS _ C 7 x 0(2 > = 2 CFS �y s'�m —�-1 rdor 0(100) = 4 CFS 0(1 .0) 2 CFS sfo SCALE.- 1' = 100' 0 6s r reek• s� CONTOUR INTERVAL = 10' ._ _. :. o , e 64fo :P`��D C 11 s LEGEND __ _ � _= ----- 1 0(25) B CFS BASIN DESIGNATION _ 0(100) = 13 CFS 6,*��43c NNOW BASIN BOUNDARY —" 64 iv POINT OF CONCENTRATION ..,' \•'...• '�{ ;�::e„ ,... •. I . DIRECTION OF DRAINAGE FLOW CULVERT (SEE ROAD PLAN OR DETAILS) QUAD MAP VPI I SCALE: 1' = 2000' ENGINEERS S R /NC. UESER GORDON MEYE NUM- BER REVISION DA TE BY Job No. 91147 - SURVEYORS 1001 GRAND AVENUE, SU/TE 2—E WOODEN DET Y? 1 I VISION APPROVAL FOR CONSTRUCTION 9/8/92 RM DRAINA GE Drown by; Q/C 3 GLf" D SPRINGS. COLORADO 81601 �S'UB voter 1�22�92 (30 945-1004 (FAX.) 945-5948 n T PLAN SCHMUGORDOMSR AS .W,� COLORADO (303) 925-6727 Appr. by: DWii OF / D . Nome: 0190QRMN LOT 116 V,9I M 1141 � V ULT -- I � \ LOT /r4 LOT If 7 \ p F ��ap` STqo. . S+ y 04 c- e N Z ( R I � ' LOT,#3 r ONLY ON LOT 18 TL9R/ry E a&4- /S NEy ¢.¢S¢OWv !lgTER s ` � \ </�yE. /N 20 o�R��ZE \ 1 SSApR� RIG �� � 4 R E4EG� SROF G� I sr Hp E 1� SA OG B x¢.. REDUCER i BEND ?� �j? 1E4P��REO PjGA� EP L/iyee ei `1/?" FiRF yY� N�q /NSTq A5�0 y SSFy�S�! LOT 19 O LOT /1 STA. 0+14.61 6" & 2-1/2" 22-1/2' 50,000 GALLON i BENDS W/ C.R.B. 's STORAGE TANK WD NO. 2 / LOT J2 WATER CONSTRUCTION NOTES. 1) PVC TO BE CLASS 160, CONFORMING TO ASTM 1784 FOR 3" AND SMALLER, AWWA C-900 (DR 18) FOR 4" & GREATER. USE 200 PSI RATED PIPE BELOW ELEV 5730. DUCTILE IRON TO BE CLASS 52. 2) PRESSURE TEST AT 200 PSI, LINE JOINTS AND F1TT7NGS TO BE LEFT OPEN FOR VISUAL TEST FOR 2 HOURS,- ANY LEAKAGE WILL BE REPAIRED. 3) DISINFECT LINE BY PLACING CHLORINE TABLETS TO TOP OF PIPE DURING INSTALLATION' SEE AWWA C601, TABLE 3 FOR REQUIREMENTS. 4) COMPACT BACKFILL TO 95% UNDER AND WITHIN 5' OF BUILDING OR ROADWAY PLATFORM AND TO 909, ELSEWHERE 5) 2-112- LINE FROM WELL NO. 1 TO 50,000 GAL STORAGE TANK TO BE LAID IN THE SAME TRENCH WITH THE 4" & 6" LINES RESPECTIVELY. 6) HORIZONTAL ALIGNMENT OF THE WATER LINES DEPICTS A 5• DEFLEC77ON (MAX.) PER JOINT, ALIGNMENT TO BE KEPT W/7HIN THE ROADWAY SURFACE. 7) ROAD TO BE ROUGH GRADED BEFORE PLACEMENT OF ANY U77LI77ES. B) CISTERN To HAVE DRAFT AND RURAL FIRE PROTEC77ONND STRICT SPECIFICATIONSECTION AS PER 9) WATERLINE COVER TO BE 6' TO TOP OF PIPE. SCHMUESER GORDON MEYER LOT #1G 1 ENGINEERS SCHAIESER GORDON MEYER INC. SURVEYORS 1001 `AND AVENUE, SUITE 2-E GLENWC0 SPRINGS. COLORADO 81601 �. (303) �5-1004 (FAX.) 94,5-5948 ASPEi" c ?LORADO (303) 925-6727 r22 STA. 13+04. 13 t 4" 90' BEND v 1, STA. 2+21.43 W/ C.R.B. -�-- HAMMES 4" 45' & 22-112' HL UE LOT X22 r - --- - BEND ` W/ C. R. -6. 's 1 STA. 14+05.04 STA. 33+4 BEND W/ 51, 45' R. B. v 4" 22-1/2' BEND � \ -------- —W/ C.R.B. \� LOT 5 79 O l6 - \ STA. 34+41.44, 45 OBU1[01vG5 WD NO 1 _� \ S74' 9f29 -WELL HOUSE ��; , \ \ ` STALOT 16 15+30f, 1" YARD .7j BEiVD k,/ R 1/?" - 9 s e WD N0. 3 . �\ o HYDRANT (FR ZELESS) B ( I K BED W/ C. R.B. LOT 116 V,9I M 1141 � V ULT -- I � \ LOT /r4 LOT If 7 \ p F ��ap` STqo. . S+ y 04 c- e N Z ( R I � ' LOT,#3 r ONLY ON LOT 18 TL9R/ry E a&4- /S NEy ¢.¢S¢OWv !lgTER s ` � \ </�yE. /N 20 o�R��ZE \ 1 SSApR� RIG �� � 4 R E4EG� SROF G� I sr Hp E 1� SA OG B x¢.. REDUCER i BEND ?� �j? 1E4P��REO PjGA� EP L/iyee ei `1/?" FiRF yY� N�q /NSTq A5�0 y SSFy�S�! LOT 19 O LOT /1 STA. 0+14.61 6" & 2-1/2" 22-1/2' 50,000 GALLON i BENDS W/ C.R.B. 's STORAGE TANK WD NO. 2 / LOT J2 WATER CONSTRUCTION NOTES. 1) PVC TO BE CLASS 160, CONFORMING TO ASTM 1784 FOR 3" AND SMALLER, AWWA C-900 (DR 18) FOR 4" & GREATER. USE 200 PSI RATED PIPE BELOW ELEV 5730. DUCTILE IRON TO BE CLASS 52. 2) PRESSURE TEST AT 200 PSI, LINE JOINTS AND F1TT7NGS TO BE LEFT OPEN FOR VISUAL TEST FOR 2 HOURS,- ANY LEAKAGE WILL BE REPAIRED. 3) DISINFECT LINE BY PLACING CHLORINE TABLETS TO TOP OF PIPE DURING INSTALLATION' SEE AWWA C601, TABLE 3 FOR REQUIREMENTS. 4) COMPACT BACKFILL TO 95% UNDER AND WITHIN 5' OF BUILDING OR ROADWAY PLATFORM AND TO 909, ELSEWHERE 5) 2-112- LINE FROM WELL NO. 1 TO 50,000 GAL STORAGE TANK TO BE LAID IN THE SAME TRENCH WITH THE 4" & 6" LINES RESPECTIVELY. 6) HORIZONTAL ALIGNMENT OF THE WATER LINES DEPICTS A 5• DEFLEC77ON (MAX.) PER JOINT, ALIGNMENT TO BE KEPT W/7HIN THE ROADWAY SURFACE. 7) ROAD TO BE ROUGH GRADED BEFORE PLACEMENT OF ANY U77LI77ES. B) CISTERN To HAVE DRAFT AND RURAL FIRE PROTEC77ONND STRICT SPECIFICATIONSECTION AS PER 9) WATERLINE COVER TO BE 6' TO TOP OF PIPE. SCHMUESER GORDON MEYER LOT #1G 1 ENGINEERS SCHAIESER GORDON MEYER INC. SURVEYORS 1001 `AND AVENUE, SUITE 2-E GLENWC0 SPRINGS. COLORADO 81601 �. (303) �5-1004 (FAX.) 94,5-5948 ASPEi" c ?LORADO (303) 925-6727 Q a F y HYDRANT (FREEZEL£SS fi 15 STA. 30+32.24, 4 t risT BEND W/ C.R.B. I \ I oo LOTZO 21 � Q <NF> a / SfAK - y ANS c IWI yY ?8+? Z LOT O � ORQNT � f � k LOT ,/•21 O W E I� (F/,E-E-/" YARD.. �•i 18 A� 20 10 ,00 LOT ELESS) X/ J x WD NO. 5'- STA. 28+05.33, 45' BEND W/ C.R.B. „� V LOT y14 oN �5{ y �l S� N � 0 0 WD NO. 4 OLOT ,,)O�11 R0 20' di 12 ' 1i --� DRAINAGE & UTILITY EAS - O.STA. 43+ 14.27, 45' J 1 7 BEND W/ C.R.B. NE N£ LOT ,x`13 INSTALL 1 "\ ST . +43.00, 45' HYDRANT YARD - BEND w�;B. I I TA, 25+ 6, 45• (FREEZELESS) I i 8ENO W/ C. . . - - �- NEW 40 WATER LINE �! (TYPICAL) ............: LEGEND OLOT NUMBER & POTENTIAL BUILDING LOCATION PERM/TIED WELL (NOT DRILLED) A ACTIVE WELL LOCATION O PUMP HOUSE LOCATION I --wrf- NEW TELEPHONE & ELECTRIC LINES -A4w- NEW WATER LINE & SIZE TR4NSFORMER VAULT 0 SPLICE VAULT r22 t v 1, STA. 48+00.00, PLUG`S` W/ C.R.B. LOT J12 / HL UE LOT X22 , STA. 33+4 BEND W/ 51, 45' R. B. - -_ � \ L0 x`17 \� 79 ExrsnNc ' - \ STA. 34+41.44, 45 OBU1[01vG5 � ih BEND W/ C. R. B. O 0 STA. 32+61.38, 45'- ( I K BED W/ C. R.B. LOT /19 \ 00 HARRIS I WD .NO. 6 LOT 115 a \ N" w `> \ \ --- STA. 37+61f 1" YARD I Q a F y HYDRANT (FREEZEL£SS fi 15 STA. 30+32.24, 4 t risT BEND W/ C.R.B. I \ I oo LOTZO 21 � Q <NF> a / SfAK - y ANS c IWI yY ?8+? Z LOT O � ORQNT � f � k LOT ,/•21 O W E I� (F/,E-E-/" YARD.. �•i 18 A� 20 10 ,00 LOT ELESS) X/ J x WD NO. 5'- STA. 28+05.33, 45' BEND W/ C.R.B. „� V LOT y14 oN �5{ y �l S� N � 0 0 WD NO. 4 OLOT ,,)O�11 R0 20' di 12 ' 1i --� DRAINAGE & UTILITY EAS - O.STA. 43+ 14.27, 45' J 1 7 BEND W/ C.R.B. NE N£ LOT ,x`13 INSTALL 1 "\ ST . +43.00, 45' HYDRANT YARD - BEND w�;B. I I TA, 25+ 6, 45• (FREEZELESS) I i 8ENO W/ C. . . - - �- NEW 40 WATER LINE �! (TYPICAL) ............: LEGEND OLOT NUMBER & POTENTIAL BUILDING LOCATION PERM/TIED WELL (NOT DRILLED) A ACTIVE WELL LOCATION O PUMP HOUSE LOCATION I --wrf- NEW TELEPHONE & ELECTRIC LINES -A4w- NEW WATER LINE & SIZE TR4NSFORMER VAULT 0 SPLICE VAULT BER I REVISION 1 APPROVAL FOR CONS7T�UC770, WOODEN DEED SUBDIVISION - SCALE.- I"= 100' CONTOUR INTERVAL 2' DATLO BY Job No. 91147 78/92 RM UTILITY Drown bw RM PLAN °°`e: 1/2192 4 Aper. 6Y - DWG OF 7 r22 � v 1, STA. 48+00.00, PLUG`S` W/ C.R.B. LOT J12 / LOT X22 TELEPHONE LINE TO BE CONNECTED-! TO EXIST. SYSTEMS, FIELD LOCATE PRIOR TO CONSTRUCTION POWERS BER I REVISION 1 APPROVAL FOR CONS7T�UC770, WOODEN DEED SUBDIVISION - SCALE.- I"= 100' CONTOUR INTERVAL 2' DATLO BY Job No. 91147 78/92 RM UTILITY Drown bw RM PLAN °°`e: 1/2192 4 Aper. 6Y - DWG OF 7 0 - MESH A_16,l i i l 'A/N PIPE 4�- TO DAYY_IG-I W,' NO. 24 j r JM SCREEN ON OU7LE NO TES. _... _ E " GATE VAL VE 't I 6" OVERFLOW PIPE t - 6" RISER PIPE PIPE Vm 12" r-24' Awwn i 1 £NT }( ROOF OPENV&G i I CENTER OF TANK 24" SHEL.i ANK MAN WA Y " 1) TANK IS LOCATED OUT OF ANY 100 YEAR FLOOD PLAIN. 2) ROOF ACCESS LADDER BEGINNING 8' OFF GROUND W17H SAFETY CAGE REQUIRED. INSTALL SAFETY HANDRAIL SYSTEM ON TANK PERIMETER EACH SIDE OF LADDER. 3) TANK TO BE BUIL T TO AWWA D-100, LATEST REVISION SHOP DRAWINGS TO 5 RISER PIPES SHALL BE FITTED W+"H BE SUBMITTED TO ENGINEER FOR APPROVAL. ) REMOVABLE SIL T STOPS, MINIMUM 2".' 4) SEE ELECTRICAL SPECIFICA77ONS FOR MAX/MUM 4" HEIGHT FROM TANK Fl 6, 0'?, DETAILS ON PROBE CO1V7ROLS TO BE MOUNTED IN TANK CON7RACT0R RESPON- SIBLE FOR CONTROL WIRE FROM TANK PLAN I/lEW TO CONTROL BUILDING 50 000 GAL. WA TER STQR' 4 LE NOT rU SCALE RETAINING RING CHLORINE FEEDER ALL PIPING WITHIN BUILDING (/INJECTOR) I TO BE SCH. 40 GAL VANIZED,- TRANSITION BETWEEN 57EEL CHLORINE CAS d PVC 6" ABOVE FLOOR FEED LINE I (1" P. E-) L4_ —} EXHAUST FAN (LOCATE BETWE-N 3AND 6' ABOVE T I FINISHED FLOOR , C*E IN EACH ROOM. 7'-O" MIN. WEIGHT FAN CAPACITY F 2�0 ACFM OR GREATER. 8,_0" MAX. SCALE 1" P.E. CHLORINE FEED - I SOLU77ON LINE 2" WATER METER r"PE CHLORINE 20Y 3" R CEPS /M ECTAR j WATER SUPPLY 3 S7RAl HEA LER { J. VAL VE,- - -- r I VAL VE B0057ER ISTEEL SLEEVE - r I PUMP I-- (TYPICAL) (2) SCALE i. j- BASE HEA TER_._.J 5.00' "� 5.00' 6" CONCRETE FLOOR � 1"LINE TAP 12"x 12 FLAB W/ WrW (TYPICAL) . F007FR (c= 3500 PSI) 3" SCH. 40 PVC (CONTINUOUS) TO STORAGES" 90' SHORT RADIUS FROM WELL FIELD TANK 3" SCH. 40 PVC ELBOW (TYPICAL) (REDUCE TO 2 1/2" APPROX. 5' FROM EDGE OF BUILDING), 6' BUR), SEC TION A —A SCALE: 1/2" = 1' It TANK WALL v WALL HEIGHT = 16' 3" ASPHAL T (COLD PATCH NOT ALLOWED) SLOPE ' � . _ TANK FLOOR TOP OF FOUNDA 710N T , z r SUBGRA°E= 3" OILED - + SAND 9" OF 3/4" BASE COURSE 1/4 z 12" STEEL i 959 COMPACT70N (ASTM D 698) RETAINING RING B" to 12" OF 3/4" BASE -� COURSE 959 COMPAC77ON PREPARED SUBGRADE (ASTM D 698) SECTION -B SCALE. +/2" f" I SCHMUESER GORDON MEYER ENGINEERS SURVEYORS u' 100 ? >ER GORDON MEYER INC. 9 AVENUE, SUITE 2-E SPRINGS. COLORADO 81601 1,4 (FAX.) 945-5948 fr0D0 (303) 925-6727 CONNECT CHLORINE S(XU77ON LINE" TO WATER MAIN -� EXHAUST FAN, DUCT SEE _VC 7701V A -A / TO -x7vvD TIJ wrHIN� �--or 6" OF KNISH FLCOR BOOSTER PUMP T 1 HEA TER 3" VALVE H£AR. A 3' s1RA/NER FROM WELL FIELD 3 SCF/ 40 PVC 2 WRIER METER -- --- t I -- EXTEND TO 5 / HOSE Jlx 2" REDUCER OUTSIDE BUILDING BIBBS CHLOIRNV£ SCALE i v & CHLOR/NA TOR 1 1/2" AIR VENT W/ 124 ALUMINUM INSECT SCREEN OR EQUIV. NON-FUSED DISCONNECT TYPE OF BURNED CABLE TO CONTROL BLDG. 24" BURY WATER LINE TO� CONTROL BUILDING 6' BURY 7" STEEL CASING SANITARY WELL SEAL ELECTRICS IWRE SPLICE LEAVE 24 OF EXTRA CABLE COILED INSIDE CASING v EXIS77NG GRADE 5' 5'x 4" CONC. PAD W/ W W.M. 8.0 t PI7LESS UNIT GROUT SEAL j SCHEDULE 40 GAL V. PIPE 2" TO 3" (SAME SIZE AS PUMP OUTLET) 3 -WIRE SUBMER5Z/BLE PUMP CABLE, ATTACH AT 20' INTERVALS ONE (1) UNDERWA TER SPLICE PERMITTED K -PACKER CHECK VALVE (W17HIN 5' OF PUMP DISCHARGE) O U 5 1/2" PVC CASING PERFORATED CASING e 155'-0" SUBMERSIBLE PUMP SET BOTTOM OF PUMP A T 180' BELOW TDP OF CASING W RESTRAINING BRACKETS CHLORINE CONTROL a NO FES: SPARE CHL ORIN£- - ROOM ROOM OI _ ._ -__ _. _ _ 1. PROVIDE A NON-FUSED DISCONNECT FOR EACH PUMP - - - --- - ---- --- -- -- j A T WEZL HEAD. CYLINDER (2) STORAGE WTH RESTRAINING --- a.I CONDO/T FOR ELECTRIC SERVICE 2 INSURE THAT PROPER BONDING IS PROVIDED. BRACKET I 'As 3. RUN NECESSARY CON7ROL CABLE FROM SUB7ROL " i - V MOUNT PANELS ON 3/4" PAINTED FINISH GRADE TRANSMITTER TO "SUB TROL" RECEIVER. PL YWOCD BACKING 2 -sow FzouaEscENT BULBS (2 REOD.)��CHLOR/NE GAS EXTERIOR MASK ENCLOSURE TYPICAL INKE A� DOOR SINTCH FOR BOTH EXTERIOR s'" �" EXHAUST FAN W GYLOR/NE LOUI�£RED I r WELL PUMP INSTALLATION IN ?,WE AT LIGHT SWITCH C£ILINC CEILING --- -_' ROOM LICHT � _ J � � l �--� �a a 4" CONC \P `FR£EZELESS EXHA�sr FAN SWITCH p WALL HYDRANT SLAB W; ucHr sVWrcH WWM. WATER LINE CONSTRUCTION NOTES EXHAUST FAN SWTCH ' 1) BED PVC PIPELINES WITH 3/4" BASE COURSE, 4" BELOW INTERIOR LICHT SWITCH TO 6" ABOVE PIPE, COMPACTED TO 959 DENSITY. i 2) PROVIDE CONCRETE THRUST BLOCKS, MINIMUM 3.0 SQ. FT. BEARING AREA ON ALL BURIED F7T77NGS. DANGER-CHLOMNE GAS" SIGN 3) PRESSURE JEST AT 200 PSI,' LINE JOINTS AND F7T77NGS MOUNTED 72" ABOVE FLOOR TO BE LEFT OPEN FOR VISUAL )FST FOR 2 HOURS,' ANY LEAKAGE WILL BE REPAIRED. 72' MAX, 8' MIN. 4) DISINFECT LINE BY ATTACHING CHLORINE TABLETS' TO TOP OF PIPE DURING INSTALLA77ON,• SEF AWWA C601, TABLE 3 FOR REQUIREMENTS. COl1 /Tj'O/ BUILDING 5) COMPACT BACKFILL TO 959 UNDEP AND WITHIN 5' OF V i1 L L7 BUILDING AND TO 909 ELSEWHERE. SCALE 1/2" = 1' BER REVISION WOODENDEER ,S'U I VISION 1 APPROVAL FOR CONSTRUC7701 ,ATE I BY 18192 1 RM NOT TO SCALE WA TER GENERAL NOTES. 1) WALL AND FLOOR SLEEVES TO BE AIR AND WATER TIGHT 2) ALL ELECTRIC AORK PER NEC CODE. 3) CHLORINE ROOM DOOR TO BE PROVIDED WITH A 12"x 12" SHATTERPROOF WINDOA; LOCATE WINDOW 2'-6" ABOVE FINISHED FLOOR ELEV4770N. DOOR TO HA VE LOCK THA T IS LOCKED A r ALL 77YES FROM 7HE OUTSIDE AND UNLOCKED AT ALL 77YES FROM THE INSIDE. DOOR TO BE WEA7HERSTYIPPED ON ALL EDGES. 4) MAINTAIN BUILDING DIMENSIONS AS SHORN; ARCHITF"C7URAL DETAIL BY OWNER AT 77ME OF CONS 7RUC 770N. 5) CHLORINE EQUIPMENT SUPPLIES TO PROVIDE POSTER GIVING CHLORINE HANDLING IN57PUC7701VS AND PRECAU77ONS FOR DISPLA Y IN CHL ORINE ROOM. DETAILS Job No. 91147 Drown by.- RM Dote: 1/21/92 App.. by: DWG 114" PLYWOOD FACE OF PYP£ DEAD END TRENCH WIDTH -� AS SPECIF70 "► SEE TABLE FOR AREA OF CONCRETE TO BEAR ON 014067URBE0 EARTH - MINIMUM 1HICKNESS EQUAL IO PIPE 0. D. SECT/ON i TEE / WYE JL£ FOR BEAR'NG AREA EAC" SIDE GA TE UAL VE 90, 45, 22.5; OR 11.25' ELBOW, HORIZONTAL OR BOTTOM OF VERTICAL SIZE (INCHES)90 ELBOWS PUMPER NOZZLE SHALL FACE ACCESS THREE PIECE �- ADJUSTABLE VAL VE BOX TEES & DEAD ENDS GATE VAL VE S 45' 22.5' 11.25 50. FT SQ. FT. SQ. FT SQ. FT _ 4 1.8 1.0 05_ 0 1.3 2.8 5.0 - -- 78 113 15.4 0..5 0.7 2.4 4.,5 %3 1_10 6 _ - B 4.0 2.2 1-1 0 7.1 J. 2.0 1.0 - 10 - 11.1 6.7 1.5 _ - 12_16.0 _3.0 8.6 4.4 2.2 14- __ _21.7 11.8 6.0-..T 3.0 TABLE OF BE4RING AREAS IN SO. Fl: TYP. CONCRETE REACTION BLOCK DETAILS VARIES i - LXIST ASPHAL T TO BE SAW CUT �l 7)P. EXISTING DIRT OR �TOPSOIL AREA �. 15 RA07 Air EGATE / e�asf SLOPE TRENCH WAILS W FOR SAFETY PER p J CURRENT OSHA & OSH REQUIREMENTS W 2 C 41M°ACTED SELECT MATERIAL Q Bc+18"/ OR!^ ASS 6 AGGREGATE` AS O-RA41NCO BY OWNER W/ OIACRON DENSITY OF 915% -R ASTM D698 h - CLASS b :CRE'GATE COMPAC' V TO 95. PER A i, OR O 3/4 SCS � FNED NED ROCK 0- 4 MIN. i`, W,' -I -Ac 2 S ARE TO BE LAID /N SAM£ 7R''P PROVIDE MIN. 12" HORZ. CLEARANC EEN PIPES 1) PAVEMENT REPLACEMENT SHALL MEET EXISTING rHICKN£SS AND K1A WITH THE FOLLOWING MINIMUMS- ASPHALT SURFACING = 3' MIN., AGGREGATE SE COURSE = 8" MIN. 2) BASE COURSE REPLACEMENT SHALL MEET EXISTING THICKNESS WIT" 4YE FOLLOWING MINIMUMS: AGGREGATE BASE COURSE = 12' MIN. 3) DIRT / TOPSOIL PLACEMENT SHALL MEEET EXISTING THICKNESS JN- IND WITH THE FOLLOWING MINIMUMS: 4" TOPSOIL. 4) SELECT MAIERYAL AS FOLLOWS: 6" MAXIMUM SIZE IN TOP 12° OF I_ 12" MAXIMUM SIZE IN REMAINDER Li"-TW L TRENCH CROSS SECTION NN. SCALE 3/4'= 1'-0' ISN ENGINEERS %I,H i£SER GOF'DON MEYER INC. SURVEYORS 1001 D AVENUE, SU17E 2-E aBN SPR/NGS. COLORADO 81601 SCHMUESER� (303 94 1004 (FAX.) 945-5948 CORDON MEYER ASPE^ GI' ;G0 (303) 925-6727 na AS REO'D CONNECT uALVE TO TF£ - TRAFFIC ; O O FLANGE 4 ; z -- FIN. - - PUMPER NOZZLE SHALL FACE ACCESS THREE PIECE �- ADJUSTABLE VAL VE BOX 11/2° DIA. VENT PIPE GRADE CONC. SKID o RM EL EV RELEASE VALVE EX7ENSION(S) v. A n AS NECESSARY 5'-0" DIA. PRECAST 6" FLxFL NON MANHOLE CONC. SKID - RISING STEM B GATE' VALVE I �u o n U 4 n ATTACH STEM GUIDE FOR OPERATOR BRICKS TO TOP SLAB OF MANHOLE WITH EXPANSION ANCHORS 0 �J � NJxFL • ` TEF CONCRETE-- i REACTION \--CONC. 4 i BLOCK o BLOCKS # v 1/2 CU YD. OF 1/2' --% \ _ PROVIDE TWO 3/4" G4LV. SEE CONCRETE COURSE GRAVEL TIE RODS W/ EYE. BOLTS REACTION &00 DRAIN MATERIAL DETAJL NOTES 1) ALL JOINTS FROM MAIN TO HYDRANT SHALL BE HARNESSED MECHANICAL JOINTS OR FLANGED JOINTS. 2) HYDRANT, VALVE AND FITTINGS TO BE- 250 P.S.I. RATED. J) ALL HYDRANT LEAD PIPING TO BE D.IP. FIRE HYDRANT ASSEMBL Y INSTALLATION DETAIL 1- THREE PIECE - ADJUSTABLE V VAL VE BOX OIti W O GFFADE x- 20 SQUARE NUT BRICk' WATE'7 MAIN GATE - _- - SEE CON REACTION VAL VE DETAIL TYPICAL GATE VALVE ,V TS i WOODEN DEER SUIDIVISION TER MAIN CORPORATION STOP & COUPLING � FINISH GRADE ELEVATION 1 1/2" TELESCOPIC CURB BOX -CURB STOP & COUPLING - TIE SERVICE I TO BUKD/NG CONCRETE BLOCK 'TYPE "K' COPPER SERV/CE LINE (CONTINUOUS) SERVICE S40DL£ W/ MINIMUM OF 2 STRAPS TYP. WA TER SERVICE DET AIL FINISH GRADE TO ALLOW AIR TO PASS in 21- 0° X 2'- 0" X 6" THICK CONCRETE PAD II/2' DIA. VENT PIPE D. I 5'- 0° DIA. 11/2'C. 1. OR GALVANIZED WALL PIPE °' PRECAST MANHOLE NON -SHRINKING GROUT �. O COMBINATION AIR o RELEASE VALVE v I 6" MIN. ' C. 1. MANHOLE STEPS (TYP.) o I ., AT 12" CENTERS e�oo;.y10 071 w +p a ♦ 04p a°e° - avi.,u.vo #4 AT 12" (TYP.) #4 AT 6" (TYR) SECTION B -B AIR & VACUUM VALVE VAULT NUM- BER B LATE 11/2° DIA. VENT PIPE o _ CONC. SKID o RM COMBINATION AIR RELEASE VALVE A A n 5'-0" DIA. PRECAST ., MANHOLE CONC. SKID B PLAN_ N.T. S. ATTACH STEM GUIDE FOR OPERATOR TO TOP SLAB OF MANHOLE WITH EXPANSION ANCHORS FINISH GRADE STEM GUIDE COMBINATION AIR qRELEASE VALVE 6-0" DIA. PRECAST e - `�- MANHOLE < NORMALLY CLOSED HOSE GATE VALVE WITH CAP NORMALLY OPEN ANGLE °' AND CHAIN VALVE WITH EXTENSION , STEM D' 1/2" EXPANSION JOINT MATERIAL BETWEEN PIPE ---,.b DOUBLE PIPE SADDLE AND MANHOLE I I _ u I I I � USE STANDARD TAPPING SADDLE FOR SIZE AND TYPE UNION OF PIPE FURNISHED SECTION A -A N.T. S. FLANGED FITTINGS 1/8' RUBBER INSERTED BETWEEN z_ FLANGES AND SPLIT CROSSWAYS p FINISH GRADE TO ALLOW AIR TO PASS in 21- 0° X 2'- 0" X 6" THICK CONCRETE PAD II/2' DIA. VENT PIPE D. I 5'- 0° DIA. 11/2'C. 1. OR GALVANIZED WALL PIPE °' PRECAST MANHOLE NON -SHRINKING GROUT �. O COMBINATION AIR o RELEASE VALVE v I 6" MIN. ' C. 1. MANHOLE STEPS (TYP.) o I ., AT 12" CENTERS e�oo;.y10 071 w +p a ♦ 04p a°e° - avi.,u.vo #4 AT 12" (TYP.) #4 AT 6" (TYR) SECTION B -B AIR & VACUUM VALVE VAULT NUM- BER REVISION LATE BY 1 APPROVAL FOR CON5777UCT/ON 9/8/92 RM WA TER DETAIL SHEET Job No. 91147 - Drawn by: Rm 6 Dote: 1121192 APPr. by: Qwv DF LOT /I 5.95 ACS o STA. O+ 14.61 2 • I 6" & 2-1/2" 22-1/2(D 50,000 GALLON \ - BENDS W/ C. R.B. 's STORAGE TANK WD NO. 2 LOT 1'2 5.48 ACf LOT //10 3.71 ACf WATER CONSTRUCTION NOTES. 1) PVC TO BE CLASS 160, CONFORMING TO ASTM 1784. 2) PRESSURE TEST AT 200 PSI, LINE JOINTS' AND FITTINGS TO BE LEF7 OPEN FOR VISUAL TEST FOR 2 HOURS; ANY LEAKAGE WILL BE REPAIRED. 3) DISINFECT LINE BY PLACING CLORINE TABLETS TO TOP OF PIPE DURING INSTALLATION; 2 TABLETS PER 20' REQUIRED. 4) COMPACT BACKFILL TO 95Z UNDER AND WITHIN 5' OF BUILDING AND TO 90X ELSEWHERE. 5) 2" LINE FROM WELL NO. 1 TO 50,000 GAL STORAGE TANK TO BE L41D IN THE SAME TRENCH WITH THE 3" & 6" LINES RESPECTIVELY. 6) HORIZONTAL ALIGNMENT OF THE WATER LINES DEPICTS A 5• DEf7 E-CTION (MAX.) PER JOINT, ALIGNMENT TO BE KEPT WITHIN 77 -IE ROADWAY SURFACE. 7) ROAD TO BE ROUGH GRADED BEFORE PLACEMENT OF ANY UTILIRES. 8) CISTERN TO HAVE DRAFT CONNECTION AS PER CARBONDALE AND RURAL FIRE PROTECTION DISTRICT SPECIFICATIONS. � BLUE � ND STA. 34+31.34, 45' BEND W/ C. R. B. LO 117 - - \ STA. 34+40, AIR & 3.02 AC.f \ VACUUM VALVE VAULT r _ / SiEx,llGI \ STA. 35+35. 3, 22-1/2' OULDIMOS \ I I x I O BEND W/ C. . B. O 0 \ \ 16 LOT /16 STA. 33+23.53, 45' I l \\ \ I I Ix 213 ACBEND W/ C.R.B. I \\ m \ \\ LOT 119j - S A. l6*00, 3" ATE VALVE 1 \ \\ \ 3.88 AC.f HARRIS 1 \ STA, *00, 3" \ \\ \ \ WD NO. 6 \ \ GATE II z I LOT 115 \ \ , — �\ \ 3.00 ACf \ \ ST �7+86.47, 45' Py, C.R.B. \\ �x \ \\\ 15 STA. 30+32.24, 45' BEND W/ C.R.B. 00 4.OT 20 21 ISI LOT #18 \\ 40 \ -m 5.47 AC.f \ \ \ LOT 121 ml 6.45 ACf I I 0 \\ WD NO. 5 \ \\ IVES \\ \\ \ I BEND2W/ C.R.B. 45 \ \ P E P RRENGGRPJEt \\ \ 2 0J acf \\ \ STA. 43+14.2-, 45' O \\ \\ \\\ \ \ \ BEND W/ C.R.B. \ I 7.41 AC.f \ ST . +43.00, 45' I I I STA- 48+25j, 1' YARD \ I BEND W .B. I I \ \� HYDRANT WITH SE I I I I I STA. 25+ 6, 45' \ �� CISCONTERN FOF FILL/NG BEND W I 10 --- / � - C � SRN I NEW 3" WATER LINE 3.62, 45' C\\ � _ 15000 GALLON STA. 23+5GSTE7'N I44 (TYPICAL) BEND W/ C. R. B _ (FIRE PROTECT/ON ONLY) 3 I I -WD N0. 4 \I 12 / STA. 48+00.00, 90' LOT x'11 BEND W/ C.R.B. 3.28 ACf A / LOT X22 LOT X12 \ / > / 9.06 AC.f / � i 5.30 AC.f \ / 0 / /AQP, / 25 26 1363. 11, / - TELEPHONE & ELECTRIC- �X\ �\ i LINES TO BE CONNECTED TO- EX/ST. SYSTEMS, FIELD LOCATE - PRIOR TO CONSTRUCTION POWERS \ i \ \ LEGEND OLOT NUMBER & POTENTIAL BUILDING LOCATION �7 D PERMITTED WELL (NOT DRILLED) A ACTIVE WELL LOCATION SCALE 1"= 100' CONTOUR INTERVAL 2' 0 PUMP HOUSE LOCATION —NTE— NEW TELEPHONE & ELECTRIC LINES -N3'w- NEW WATER LINE & SIZE PRELIMINARY PLAN SUBMITTAL 1/21/92 STA. 13+04.13 3" 90' BEND STA. 12+21.43 W/ C.R.B. HAMMES 3" 45' & 22-1/2• x BENDS W/ CR.B.'s —- \ STA. 14+05.04 \ 3" 22-1/2' BE -- - -- \ W C. R. B. \ \ LOT 115 O WD \ J l \ LOT #6 l �\ NO• 1-.�-� 90A c/vo 80, BEND \ / WELL HOUSE • l WD NO. \ 2.02 ACf \ \ {y/ R��1°t°z60 y \ SrA BEN0254, ?-1/p^ \\\� �� <�` �i� 45' BEND 3.44,.R.B. S7A. 7 eB w/ C.R.B VgC/jUM -41? B i 1141 E Vq!/LT i z \ LOT 14 �in� o LOT 17 5.80 AC.f / i v 2.01 AC.f STq, 'S�?628 / / ND •N D--{ �R� / N m I I I ° I O O I � I LOT #3 I 1 6.03 AC.f \ cNL y ONE \ \ p4 l,,) l/NE- /S \\ LOT #8 3.38 AC.f \ Ncryy �SyOkN f'0 19 3" L/yE /N sgME E Sz�'i� �ELPV, R ocl 61, 4.28 LOTA f LOT /I 5.95 ACS o STA. O+ 14.61 2 • I 6" & 2-1/2" 22-1/2(D 50,000 GALLON \ - BENDS W/ C. R.B. 's STORAGE TANK WD NO. 2 LOT 1'2 5.48 ACf LOT //10 3.71 ACf WATER CONSTRUCTION NOTES. 1) PVC TO BE CLASS 160, CONFORMING TO ASTM 1784. 2) PRESSURE TEST AT 200 PSI, LINE JOINTS' AND FITTINGS TO BE LEF7 OPEN FOR VISUAL TEST FOR 2 HOURS; ANY LEAKAGE WILL BE REPAIRED. 3) DISINFECT LINE BY PLACING CLORINE TABLETS TO TOP OF PIPE DURING INSTALLATION; 2 TABLETS PER 20' REQUIRED. 4) COMPACT BACKFILL TO 95Z UNDER AND WITHIN 5' OF BUILDING AND TO 90X ELSEWHERE. 5) 2" LINE FROM WELL NO. 1 TO 50,000 GAL STORAGE TANK TO BE L41D IN THE SAME TRENCH WITH THE 3" & 6" LINES RESPECTIVELY. 6) HORIZONTAL ALIGNMENT OF THE WATER LINES DEPICTS A 5• DEf7 E-CTION (MAX.) PER JOINT, ALIGNMENT TO BE KEPT WITHIN 77 -IE ROADWAY SURFACE. 7) ROAD TO BE ROUGH GRADED BEFORE PLACEMENT OF ANY UTILIRES. 8) CISTERN TO HAVE DRAFT CONNECTION AS PER CARBONDALE AND RURAL FIRE PROTECTION DISTRICT SPECIFICATIONS. � BLUE � ND STA. 34+31.34, 45' BEND W/ C. R. B. LO 117 - - \ STA. 34+40, AIR & 3.02 AC.f \ VACUUM VALVE VAULT r _ / SiEx,llGI \ STA. 35+35. 3, 22-1/2' OULDIMOS \ I I x I O BEND W/ C. . B. O 0 \ \ 16 LOT /16 STA. 33+23.53, 45' I l \\ \ I I Ix 213 ACBEND W/ C.R.B. I \\ m \ \\ LOT 119j - S A. l6*00, 3" ATE VALVE 1 \ \\ \ 3.88 AC.f HARRIS 1 \ STA, *00, 3" \ \\ \ \ WD NO. 6 \ \ GATE II z I LOT 115 \ \ , — �\ \ 3.00 ACf \ \ ST �7+86.47, 45' Py, C.R.B. \\ �x \ \\\ 15 STA. 30+32.24, 45' BEND W/ C.R.B. 00 4.OT 20 21 ISI LOT #18 \\ 40 \ -m 5.47 AC.f \ \ \ LOT 121 ml 6.45 ACf I I 0 \\ WD NO. 5 \ \\ IVES \\ \\ \ I BEND2W/ C.R.B. 45 \ \ P E P RRENGGRPJEt \\ \ 2 0J acf \\ \ STA. 43+14.2-, 45' O \\ \\ \\\ \ \ \ BEND W/ C.R.B. \ I 7.41 AC.f \ ST . +43.00, 45' I I I STA- 48+25j, 1' YARD \ I BEND W .B. I I \ \� HYDRANT WITH SE I I I I I STA. 25+ 6, 45' \ �� CISCONTERN FOF FILL/NG BEND W I 10 --- / � - C � SRN I NEW 3" WATER LINE 3.62, 45' C\\ � _ 15000 GALLON STA. 23+5GSTE7'N I44 (TYPICAL) BEND W/ C. R. B _ (FIRE PROTECT/ON ONLY) 3 I I -WD N0. 4 \I 12 / STA. 48+00.00, 90' LOT x'11 BEND W/ C.R.B. 3.28 ACf A / LOT X22 LOT X12 \ / > / 9.06 AC.f / � i 5.30 AC.f \ / 0 / /AQP, / 25 26 1363. 11, / - TELEPHONE & ELECTRIC- �X\ �\ i LINES TO BE CONNECTED TO- EX/ST. SYSTEMS, FIELD LOCATE - PRIOR TO CONSTRUCTION POWERS \ i \ \ LEGEND OLOT NUMBER & POTENTIAL BUILDING LOCATION �7 D PERMITTED WELL (NOT DRILLED) A ACTIVE WELL LOCATION SCALE 1"= 100' CONTOUR INTERVAL 2' 0 PUMP HOUSE LOCATION —NTE— NEW TELEPHONE & ELECTRIC LINES -N3'w- NEW WATER LINE & SIZE PRELIMINARY PLAN SUBMITTAL 1/21/92 9,0 70 / A��ESS R/ SITE PLAN ABSORPTION S YS TEM SCALE: /" = 20' NOTE- FOR TYPICAL RESIDENCE ONL Y WITH ASSUMPTIONS AS NOTED, NOT FOR CONSTRUCTION. EACH SYSTEM WILL BE DESIGNED FOR SITE SPECIFIC RESIDENCE SIZE AND PERCOLA TION RA TE. 50 SCALE.• l" a 20' 1. All materials, installation practices, setback requirements, etc., shall comply with the Garfield County Individual Sewage Disposal System Regulations. 2. The absorption bed shall be constructed so that the bottom is level + 0.1 inches. Place bed in natural ground; no portion of the bed shall be placed in fill. Provide positive drainage away from bed. 3. Stone shall be 1/2" to 2-1/2" screened rock. 4. All areas disturbed by construction shall be reseeded with native grasses to prevent erosion. 5.. The location of the bed may be adjusted in the field to better fit the site, provided all setbacks are met. 6. Use risers as needed to bring septic tank access hatch within 6" of finished grade. 7. Cast iron pipe or pipe of equal strength or other pipe properly supported to prevent failure by settling shall extend from tank for a distance of at least five feet (51) from the inlet and outlet ends. 8. The Contractor and Owner shall take whatever measures are necessary to assure that (a) septic tank and sewer lines are completely water -tight to prevent infiltration of groundwater into the system, and (b) the system is to be installed to prevent freezing of all pressure and gravity sewer lines. 9. The location of existing utilities must be verified by Contractor prior to commencing work. 10. The Garfield County Environmental Health Department and the Engi- neer shall be notified when construction commences and kept abreast of the construction progress so that sufficient inspection can be performed to assure conformance with these plans. 11. The following preventative maintenance schedule is recommended to prolong the life of the system. a) Pump septic tanks once each year. b) Check plumbing fixtures on a regular basis and repair all leaks which can add substantial amounts of water to the system. 12. Site map & topography supplied by Omer. SECT/ON A -A SCALE /" = 3' DESIGN CRITERIA 1. Number of bedrooms = 3 (plus I loft) 2. Assume 2 persons/bedroom and 75 gpcd. 3. Flow = 600 gpd (average daily) 4. Perc = 10 min/inch 5. Area (bottom of bed) A = 1.95 Q - 0.55 Q L Where: Q = average daily flow L = loading rate based on 10 MPI (L = 0.80 gal/sq.ft./day) A = 1.95 (600) - 0.55 (600) 0.80 A = 1132.50 sq.ft. 6. Make bed size 34' x 34' for total sq. ft. of 1156. SCHMUESER GORDON MEYER INC. _ ENGINEERS & SURVEYORS M 1512 GRAND AVENUE, SUITE 212 GLENWOOD SPRINGS, COLORADO 81601 (303) 945 - 1004 REVISIONS NO. I DESCRIPTION I DATE I BY I CMKD.I r / [ APPROVAL FOR CONSTRUCTION 19181921 DWG )DEN DEER SUBDIVISION TYPICAL ABSORPTION SYSTEM GARFIELD COUNTY C 9//47 11121192 1 RM I NOTED 1 DWG 1 7 of 7