HomeMy WebLinkAboutSpecial Inspection Report 02.26.2018West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Report #5 Page 1 of 1 Date: 2-26-18 Project: Orchard Creek Ranch LLC Address: 156 County Rd. 137 Garfield County, CO Building Permit No: BLRE-10-17-4973 General Contractor: Doug Hayes Construction Contractor that Performed Work: Sopris Steel Inspection of shop fabrication or field work at job site: Field Report: Visually inspected field welding & high strength A325 bolting at plate type moment connections roof level framing grids C & D. Also re -inspected connection noted in the last report #4. Angle clips with slotted holes had been welded to web of primary beam with 1/4" fillet welds. The onsite welding & bolting inspected/re-inspected above appeared to be in substantial conformance with the plans, and the quality requirements of the AWS D1.1 Structural Welding Code & the AISC/RCSC Specification for high strength bolting. Further inspections will need to be performed as work progresses on the project. Inspector/Technician: Douglas E Young Douglas E. Young C Certification #5102224 ucturall Wel' g S i • ' =1 Steel & Bol iedl 'tcp fil !'i,. Inspector is! Inspector