HomeMy WebLinkAboutManufacturer's Specs on Gas StoveINSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
(1�) INSTALLATION AND
NAPOLEON OPERATING INSTRUCTIONS
CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22 AND ANSI Z21.50, FOR VENTED GAS FIREPLACES.
FOR INDOOR USE ONLY
SAFETY INFORMATION
AWARN ING
If the information in these instructions
are not followed exactly, a fire or
explosion may result causing property
damage, personal injury or Toss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to Tight any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
BA
B36NTR / B36NTRE &
GX36NTR-1 / GX36NTRE-1
NATURAL GAS MODEL
B36PTR / B36PTRE &
GX36PTR-1 / GX36PTRE-1
PROPANE GAS MODEL
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at -risk individuals.
RRIER
HPBIA
Ika ), Rao & Barbs. ll..o[Slllon
4 ySpom OTrr +f Ie
ISD
9001-200B
Intertek
Wolf Steel Ltd, 24 Napoleon Rd., Barrie ON, L4M 008 Canada /
103 Miller Drive, Crittenden, Kentucky USA, 41030
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfireplaces.com • hearth@napoleonproducts.com
$10.00
1.280
Erg
FR
PG
83
W415-1678 /13 / 03.27.17
7
2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST -FIRED TO ASSURE ITS OPERATION AND
QUALITY!
When the appliance is installed at elevations above 4,500 ft (1371 m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000 ft (305m).
This appliance is approved for bathroom, bedroom and bed -sitting room installations and is suitable for
mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas millivolt system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
W415-1678 / B / 03.27,17
RATES AND EFFICIENCIES
B36
GX36-1
NG
P
NG
P
Attitude (FT)
0-4,500
0-4500
0-4,500
0-4,500
Max. Input (BTU/HR)
18,000
18,000
26,000
26,000
Min. Inlet Gas Supply
Pressure
4.5" (11mb) w.c.
11" (27mb) w.c.
4.5" (11mb)
w.c.
11" (27mb) w.c.
Max. Inlet Gas Supply
Pressure
7
13" (32mb) w.c.
13" (32mb) w.c.
13" (17mb) w.c.
13" (32mb) w.c.
Manifold Pressure (Under
Flow Conditions)
3.5" (9mb) w.c.
10" (25mb) w.c.
3.5" (9mb) w.c.
10" (25mb) w.c.
MODEL
DESIGNATIONS
FUEL TYPE
OPERATING SYSTEM
B36NTR
NATURAL
MILLIVOLT
B36NTRE
NATURAL
ELECTRONIC IGNITION
B36PTR
PROPANE
MILLIVOLT
B36PTRE
PROPANE
ELECTRONIC IGNITION
GX36NTR-1
NATURAL
MILLIVOLT
GX36NTRE-1
NATURAL
ELECTRONIC IGNITION
GX36PTR-1
PROPANE
MILLIVOLT
GX36PTRE-1
PROPANE
ELECTRONIC IGNITION
When the appliance is installed at elevations above 4,500 ft (1371 m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000 ft (305m).
This appliance is approved for bathroom, bedroom and bed -sitting room installations and is suitable for
mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas millivolt system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
W415-1678 / B / 03.27,17