HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLCO-1_O-t7-4978
Vanguard Operating, LLC
Wa rehouse/Storage Bu ild ing
TBD County Road 33L
Silt, Colorado
1) ALL WORK SHALL COMply W|TH THE 2015 INTERNATIONAL BUILDING CODE (l.B.C.)
2009 I NTERNATTONAL Ft RE CODE (t. F.C.) AN D MAN U FACTU RER'S I NSTALLATION
SPECIFICATIONS.
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY'S BUILDING REQUIREMENTS &
INSPECTIONS POLICIES.
3) WORK SHALL COMply W|TH REQUTREMENTS OF RURAL ZONE DISTRICT AS DEFINED lN
GARFIELD COUNTY,S LAND USE & DEVELOPMENT CODE, AND ALL CONDITIONS OF THE
cURRENT LAND USE CHANGE pERMTT (LrPA-05-14-79L5) INCLUDING DIRECTOR'S
DESCISION DATED MARCH 22,20L8.
4) BUtLDtNG tS APPROVED AS NON-SPRINKLERED, CONSTRUCTION TYPE ll-B (NONCOM-
BUSTTBLE) WtrH "LOW-HAZARD STORAGE" (GROUP S-2) OCCUPANCY/USE.
5) CONTACT LOCAL FtRE DTSTR|CT FOR REVIEW AND APPLICABLE l.F.C. REQUIREMENTS.
FIRE DISTRICT,S FINAL APPROVAL REPORT IS REQUIRED PRIOR TO FINAL BUILDING
INSPECTION & CERTIFICATE OF OCCUPANCY.
6) ANy FUTURE CHANGES TO OCCUPANCY TYPE OR USE OF THE BUILDING MUST COMPLY
WITH APPLICABLE ZONING REGULATIONS AND/OR LAND-USE CHANGE PERMITS UNDER
REQUIREMENTS OF GARFIELD COUNTY,S LAND-USE DEVELOPMENT CODE. ANY SUCH
CHANGES MAY ALSO BE SUBJECT TO ADDITIONAL BUILDING DEPARTMENT AND/OR FIRE
DISTRICT REVIEW, PERMITTING & INSPECTIONS.
7) OPEN-HOLE SOTLS REPORT rS REQUTRED AT FOOTTNG INSPECTION, 2000 PSF.
8) PROV|DE AT LEAST ONE (1) WALK DOOR W|TH 36" X 80" MINIMUM SIZE FOR EGRESS,
PER l.B.C., SECTION 1010.1.
9) ALL HIGH STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR PER
SPECIAL INSPECTIONS PROVISIONS OF I.B.C., CHAPTER 1.7. PROVIDE APPROVAL REPORT
AT FRAME INSPECTION.
10) tF AppLtcABLE, ELECTRTCAL PERMTTTTNG AND INSPECTIONS BY COLORADO STATE
ELECTRICAL BOARD. ELECTRICAL FINAL APPROVAL IS REQUIRED AT FINAL BUILDING
INSPECTION & CERTIFICATE OF OCCUPANCY.