HomeMy WebLinkAboutOWTS Design Report 05.13.2018ALL SIHYICEMay 13, 2018" 33 Four Wheel drive Rd Carbondale, CO 81623 970-309-5259 Travis Stanley Integrated Elements Construction Tstan34@gmail.com Subsurface Investigation and Onsite Wastewater Treatment System Design 3 -Bedroom Residence 1000 CR 323 Garfield County, Colorado Travis, Project No. C1371 ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The 5 -acre property is located outside of Rifle, in an area where OWTSs and wells are necessary. Legal Description: Section: 31 Township: 6 Range: 94 TR OF LAND SITUATED IN LOT 2 Parcel ID: 2175-312-00-011 SITE CONDITIONS A 2 -bedroom, single-family residence is currently developed on the property and a 1 -bedroom addition is in progress. The existing septic tank serving the residence will be abandoned. The residence is served by a private well located on the western portion of the property greater than 50 - feet from the new septic tank and greater than 100 -feet from the proposed soil treatment area (STA). The proposed soil treatment area (STA) location is relatively flat. The STA must be at least 10 -feet from the property line and at least 10 -feet' from the new addition. The STA must also be at least 10 -feet from the power line. SUBSURFACE The subsurface was investigated on May 7, 2018 by digging one soil profile test pit excavation (Test Pit). A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.2 Test Pit was dug and Garfield County was contracted to run percolation testing; however, due to slow percolation results, Garfield County required an engineered OWTS for this property. The materials encountered in the Test Pit #1 consisted of light brown clayey topsoil to 2.0 -feet, underlain by medium to reddish brown to tan clay soils to 4.0 -feet, underlain by medium brown to gray silt loam with gravels to a maximum depth explored of 8.0 -feet. No bedrock or groundwater was encountered. 1 Regulation 43 adopted June 30, 2017 allows minimum setback to a structure without a basement, crawl space, or footing drains to be reduced to 10 -feet. This change will be adopted by Garfield County by June 30, 2018. 2 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile Evaluation of Soils Training. Page 2 A tactile analysis of the soils was taken from Test Pit #1 at 4 -feet below grade, in the silt loam horizon. Soil structure grade was moderate, soil structure shape was single -grain to blocky, and consistence was loose to friable. The soil formed a ball and a ribbon less than 1 -inch in length before breaking. Soil texture was smooth. STA sizing is based on Soil Type 2, Silt Loam with weak structure grade. A long term acceptance rate (LTAR) of 0.6 gallons per square foot will be used to design the OWTS, in accordance with Table 10-1 Soil Type 2 presented in the Garfield County On -Site Wastewater Treatment System Regulations, adopted April 14, 2014. Test Pit (3 different horizons) Sieved sample (at 4 -feet below grade) Page 3 DESIGN SPECIFICATIONS The existing OWTS serving the original part of the residence will be properly abandoned by crushing the septic tank and filling the remaining void with onsite soils. OPTION: The existing STA can either be abandoned in place or a Bull Run Valve (specifications enclosed) may be installed on the line exiting the septic tank where the it can lead to either the new STA or the existing STA. Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms = 450 GPD LTAR = 0.6 GPD/SF 450 GPD / 0.6 GPD/SF x 1.2 (gravity bed) x 0.7 (chambers) = 630 SF The new OWTS design is based on 3 -bedrooms. An average daily wastewater flow of 450 GPD will be used. The sewer line exiting the residence and the 1000 -gallon, two-compartment Forterra concrete septic tank have already been installed. An effluent filter must be installed on the outlet tee of the septic tank. Risers must bring the manhole lids to grade for access. If more than one riser is added to the septic tank, an extension handle must be installed on the effluent filter. Effluent will gravity flow to a level manifold connecting four rows of 14 `Quick 4' Standard Plus Infiltrator® chambers for a total of 56 chambers and 672 square feet of infiltrative area. The infiltrative area must be installed in the silt loam horizon, below the clay horizon. This was encountered at approximately 4 -feet below grade in the Test Pit. Inspection ports must be installed in the four corners of the bed. Ports may be cut to grade and placed in sprinkler boxes for access. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Garfield County On -Site Wastewater Treatment System Regulations, the OWTS Permit provided by Garfield County Building Department, and this design. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo -fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on backfilled STAs. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. Page 4 If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3 -inch. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, ALL SERVICE septic, LLC 604)-t_ Co_ Ov-bf-Ls Carla Ostberg, MPH, REHS Reviewed By: I=.0=1 1 C7 74400t, peOH eApa IaauM anO££ 6L£1•3 :JegwnN peFOad a3uapiseJ IaiueQ3W 7.1 < CC/) C. (. � O (D co n Q y co W Z 0 I co 0 1-/E 1-/g0 :algia b 40 G laeLIS O 0 0 D rii Z County Road 323 30.00' R -O -W 0 0 0 Z D Z z Z meso) H0S mzc y�oo =m m0c o H m Ui cn 0 w1 Z • L1 • 1 57.34'cmnvpm CwcD 0=0 �'N 0 ,±,, 73 (:)o m 0 • CT N l" .. _L U-1 O j Gd 5. LT1 0 � rvm me> m in O 0 ! zOZ O 0L� N N L • . 4' 4 0) CD • •• 0) CD Shed C 0 CD . 6 e , •s` • • 6 I✓ TTUP ONLLSIX3 a3NOdNVEIV A1213dO21d 3H1 I - O0 *m m* � m mr r Z r O • D O m zv OZ 3N I=.0=1 1 C7 74400t, pend eApa ieeuM anO££ JeciwnN Pe[Oad a3uapiseJ IaiueQ3W o � o CI) < CD < C. (. CD co co a z W W 7.1 0 co -0 0 c C m co N ■ O SIM° 43SOdO Id i i m m 73 1- 0 m Om 0 D Z Cn O CO 0 z00 0 z O m0� 01 310c1 213MOd INOIJ Ol Wf1WINIW ZJ N m m W X m cn M 0z 0 00 m� _L -L o� O m _ 1 Z r •� ZO d 41141k. F=1 O z Ol ,0I• 'NUN 0 0 z�g o 0 o 1— W D -0mp mw� -�W 0m01 y -am r m D Z r 0z cm 01 rn —1 0 —1 Z 0 D Z o (7 mmmOo m D r r momH0 mOz D Z r m �m>D • -10 C 00 1— Z • m0 m X z m z O m D z z m C 0 z0 m0 <0 z cnz D 0 0 3A1VA NIH Tine TIV±SNI :NOI1d0 E D co O mO1 m 0m - pJ DC z m V1S 3O 2:0N12:100 0 m Ut O O HOV3 1V12:10c1 NO110dSNI 3S ZL9 = S2:1381/WHO 99 Z M 0� m0 C On m 00 22 DD co co mm cnW n m 0 peOH eApa ieeuM anOd ££ 6L£I.0 :JegwnN TOa*Oad G) Q o O 0 • C) w o • w 0 0 s 0 n 0 a3uapiseJ IaiueQOw 7.1 v < �CD C. (. CO Q CD cp- • c Z • 7.1W co -0 O 1-/E 1-/g0 :8180 b40£�aa4S 3IVOS 01 1ON X x D O Om z > 1= I- x111-1II- 1 IIIII III I III l`d12�31t/W HONI-£ SfNIW 391SflV llId>love 1IV13O l iOd NOI1O3dS 3LVld GN3 c)C CO WC) -I m X 0) K M i0 00 cm 0� OD OO mm0 -1 n 0o cm Dnp co m ^ D ,71 m m -I I- X D C) Z O m 0 I— cn� G) m mO G)—I0 O z co rn m m 0 m 0 H 1z • D� mr 7301- X�� z D 00 m N m 0 S- OD mz� m H CO �Om oo=Cf) Mme O cno) �1 I D om o Dm m — =0 O � O m z Z 0 0 0 0 m NV1d ` IS C) m D z 0 D S3IVld GN3 >• < z00 Ti m D O m0 r w cn 0 z z 0 2 0 c L7 m M02:1 2:13d S2J381A1VHO 176 01 rn - D ; 0 D -0 m� n cwn Z — nz O -0 Z • m m� O z m 31Vld GN3 2:1OIVJ1lldNl C)G) �< wm m x ca 0 0 3NI1213M3S 9£-2dGS Via „P o-0 0 v -v @ 3 0 m o°� ca 6,) m 5. (0o CD cn CD cNn N oo 0 b co0 3 °' N 0) pend eApa ieeuM an0£E 6LE1.0 :JegwnN peFOJd a3uapiseJ Iaiueavi 0 71 0 < < C. (. CD W n a y coW Z co I 0 94/£4/g0 :8180 b 40 b laat-IS VOS 01 L0N z 0 ti ti 0 n D -11VI a HON]2i1 (1) 0 1 r 0 m n O m zm 0z m 0 00 -0000ED 0=0molEa 0D 00 z0mD,«< rmp-C-1 0�r�d a'0mX�-170D Dm0 m cnW 0 73E p1cn„m0>K D m� (0O Dz r Tzm z n T o u-0 D z 0 D a m Cn D�:Ill xmkrzy �� X 0 7:1 c) - 0 "Nm _ KOW�'xDmCn n 0 oo=m a 1> 0 0m 0 D 0 0 N u 5 D K > cn W o (-P - mcn > m Cn0"'om D r0 0 m N 0 c) E zO m m cn -mOD co II 0 z m v II 70 0 00 0 0 2D m 0 0 E C m 0) com H co 0 m m 0 cn 0 II 0 0) -1 0 00 W = -1 > > co z m 0) DEPTH - FEET II I I I I I I I I I I I I I 0 0o rn 01 w O NOLLVAVOX3 JNI Ifla a32:131Nf1O0N3 >1002:1a38 2IO b31VMaNnOdJ ON \ .\ .\ .\ . \•\•\•\ �m D 0 mE r � cn co 0 Cnz 1 H r O D H 2 r O D AV10 NM02:18 HSIaa32d Ol VJ Ia3W 110Sd01 NM02:18 1H011 I 'ON lId 1S31 811dO2Id 1IOS C) 0 3 0 o o_ 3 r m 0 m z 0 0 m 0 z Residential Biotube® Effluent Filters Applications Our patented* 4 -in. (100 -mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. 4 -in. (100 -mm) Biotube Effluent Filter 4 -in. (100 -mm) Biotube Jr. (4 -in. Biotube cartridge avail- able separately as Insert Filter) 8 -in. (200 -mm) 4 -in. (100 -mm) Base Inlet Filter Insert Filter Orenco's superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4 -in. (100 -mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4 -in. (100 -mm) Biotube Jr, at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low profile tanks, there's the Base Inlet Filter. * Covered by patent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS -FT -1 Rev. 3.4 © 11/10 Orenco Systems®, Inc. Standard Features & Benefits • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal Optional Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion -proof construction, to ensure long life • Lifetime warranty Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. Cal Orenco Systems" I ncorporated Changing the Way the World Does Wastewater° www.orenco.com Nomenclatures 4 -in. Biotube Filter (standard) FT 04 I Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard Housing height: 36" and 44" are standard Filter diameter (inches) W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series 8 -in. Biotube Filter (base inlet model) FT 08 22 -14 B Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate* Base inlet model Cartridge height: 14" standard Housing height: 22" standard Filte diameter (inches) 08 = 8" Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series * Also available with coupling and sleeve as a "kit": FT-OVERFLOWKIT 4 -in. Biotube Jr. (includes cartridge and housing) FT J 04 18 Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height (inches) Filte diameter (inches) fits Type 3034 outlet tee fits Schedule 40 outlet tee W= s= Blank = 1/8" filtration P = 1/16" filtration Junior series Biotube effluent filter series 4 -in. Biotube Filter Insert (cartridge only) FTi 0418 - For customized options (e.g., NC indicates North Carolina regions) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Cartridge height (inches) Filte diameter (inches) Blank = 1/8" filtration P = 1/16" filtration Insert Biotube effluent filter series 4 -in. Biotube Effluent Filter Extendible PVC handle 4 -in. Biotube Jr. Stainless steel set screws Top seal plate Air vents Biotubefilter cartridge )000( Solid base — Riser a wall Filter housing / Distributed By: Item # BRVBULK Bull TM Run Valve & Key The Bull Run Valve is available in 4" SCH 40 PVC and is suitable wherever septic disposal systems are used — in commerical, industrial, and residential application. OPERATING THE VALVE The direction control handle should be rotated periodically to direct effluent to one or the other of two septic fields. After removing the screw cap at the top of the riser tube, the valve handle can be turned with the valve key furnished. ADAPTABLE TO VARIOUS PIPES Each valve port connection is a 4" schedule 40 female slip connection. The riser tube connection is a 4" schedule 40 male slip connection. Use ample PVC, ABS, or multi—purpose glue to form a water—tight joint. Any of the following can be used to connect the valve: 1) Schedule 40 PVC or ABS pipe 2) Adapter bushing (Dwv Hub to sewer (Sc drain spiget) 3) ASTM 2729 (Schedule 30) 4) Bell End of ASTM 2729 (Schedule 30) pipe RISER CAP ADAPTER RISER TUBE 4" OUT PORT o r t t --41-#1.$11 WATER -TIGHT %NO }� ACCESS CAP VALVE DIRECTION 1016 HANDLE 8 w. -.....i ..._ # *EEO, 21„. 4" OUT PORT 4" IN PORT Water & (719) 3954764 28005 Co. Rd. 317 Wastewater P.O. Banc 925 liFITALLEY • • Pr duc sFax: (719) 395-3727 &vela,81211 PRECAST, Inc. • Service Website: www.valleyprecast.00m Email: frontdesk©valleyprecast.00m INFILTRATOR' water technologies Quick4 Plusu Series The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36 -inch -wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connectiono which permits turns up to 15 -degrees, right or left. It is also available in four -foot lengths to provide optimal installation flexibility. The Quick4 Plus All -in -One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength Quick4 Plus Standard Chamber Specifications Size 340VV x 530L x 120H (864 mm x 1346 mm x 305 mm) Effective Length 480 (1219 mm) Louver Height 80 (203 mm) Storage Capacity 47 gal (178 L) Invert Height 0.60 (15 mm), 5.30 (135 mm), 8.00 (203 mm), 12.70 (323 mm) Quick4PLUS CHAMBER SYSTEMS The Quick4® Plus Standard Chamber Quick4 Plus Standard Chamber Benefits: • Two center structural columns offer increased stability and superior strength • Advanced contouring connections • Latching mechanism allows for quick installation • Four -foot chamber lengths are easy to handle and install • Supports wheel loads of 16,000 lbs/axle with 120 of cover Quick4 Plus All -in -One 12 Endcap Benefits: • May be used at the end of chamber row for an inlet/outlet or can be installed mid -trench • Mid -trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows • Center -feed connection allows for easy installation of serial distribution systems • Pipe connection options include sides, ends or top APPROVED in Quick4 Plus All -in -One Periscope Benefits: • Allows for raised invert installations • 180° directional inletting • 120 raised invert is ideal for serial applications Certified by the International Association of Plumbing and Mechanical i R� Officials (IAPMO) (�J Quick4 PlusU Series Quick4 Plus Standard Chamber Quick47s CHAMBER SYSTEMS 34" Quick4 Plus All -in -One 12 Endcap 48" EFFECTIVE LENGTH PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 13" 33" FRONT VIEW Quick4 Plus All -in -One Periscope QUICK4 PLUS ALL -IN -ONE PERISCOPE /.1/ (360° SWIVEL) 12.7" INVERT 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475 INFILTRATOR° 88002210-443 6 360-577-'00' www.infiltratorwater.com water technologies SIDE VIEW INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY (a) The structural integrity of each chamber, endcap and other accessory manufactured by Infiltrator (Wnits0), when installed and operated in a leachfield of an onsite septic system in accordance with Infiltratorl instructions, is warranted to the original purchaser (I]Holderf) against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator will supply replacement Units for Units determined by Infiltrator to be covered by this Limited Warranty. Infiltratorl liability specifically excludes the cost of removal and/or installation of the Units. (b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential, special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from installation or shipment, or from any product liability claims of Holder or any third party. For this Limited Warranty to apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and Infiltrator[ installation instructions. (d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No warranty applies to any party other than the original Holder. The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of Units should contact Infiltrator0u Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units. U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico. Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies. PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra -Rib is a trademark of IPEX Inc. © 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A. PLUS05 0713 Contact Infiltrator Water TechnologiesoTechnical Services Department for assistance at 1-800-221-4436