Loading...
HomeMy WebLinkAboutCORRESPONDENCE LETTERSDave Argo From: Sent: To: Subject: Attachments: Chris K <ckouray@yahoo.com> Tuesday, June 20, 20L7 2:2LPM Davo Argo Velasquez Resi<lence 3064 C¿l.tle Creek Road Floor Franritrg Compliance VelasquezFloorCompliance0620lT. pdf; VelasquezBC CALC Project.pdf Garfield County Building Department Attached is my compliance letter that is in agreement with the client's wish to add a light-weight concrete floor system in lieu of a wood floor system. I assume that change is due to their desire to install efficient in-floor heating. I also attached the Boise Cascade design documentation that I reviewed... If you have any questions or comments, feel free to contact me at your conven¡ence Christopher Krabacher (970) 640-8831 1 I CHRT5TOPHER KRABACHER Project: Velasquez Residence 3064 Cattle Creek Road, Garfield CountY, Colorado General Contractor: Ross Velasquez (970) e8e-3008 lf we can be of anY rther service, feel free to contact us' Licensed Architect in the State of Colorado (#8-2062) Structural ComPliance The Builder requested the investigation to determine if the foundation & floor system is sufficient ilrghto ."irv " nint*ã¡ör,i""ñ"rÀt" ftoot, and has the appropriate design capability' lnformation Reviewed' Boise cascade Froor Design Report (dated June 16, zafl) indicates the buirding floor system is capabre of carrying tnã pioîoleo maàr¡aìload(s) and code-required rive road. Minimum loao/o toad inferreO is arounã åOO'ir.tt. ft{aximum load exceeds that by 100%' ( i utv;¡ ¡¡u¡';') ARCHTTECT P.O. Box 2592, Grand Junction, Colorado 81502 t-gzol 243-3s87 (office) (970) 640-8831 (cell) ikourav@vahoo'com chriskrabacheril'chitect'corn June 20, 2017 Determinations- 1t-Tú F"undation system is sufficient to withstand applicable loads' 2) The Floor system is sufficient to withstand applicable loads.'tl û¿ ¿. 1. ) "å i.l;\=É-r.-. i.,Jt I "0 fñ) "o'"" """""0"Double 1-314" x9-112" VERSA-LAM@ 2.0 2800 DF E Dry l3 spans I No cantilevers l0/12 slope File Name: BC CALC Project Description: Designs\F801 Specifler: Designer: Company: Misc: Floor Beam\FB0î June 16, 2O17 16:16:25 BC CALC@ Design Report Build 6036 Job Name: Address: City, State, Zip: , Customer: Code reports: ESR-1040 08-0Þ00 08-00-00 Total of Horizontal Desiqn Spans = 24-00-00 08-00-00 BO B1 82 B3 Reaction Summary (Down / Uplift) ¡ lus ¡ Live Dead Snow Wind Roof LiveBeãr¡nd BO B1 82 B3 1,800 / 200 4,800 / 0 4,800 / 0 1,8001200 2,0751O 5,707 l0 5,707 l0 2,075 lO Live ,lîîo/" Dead 900/" Snow 1150/" Wind Roof Live 1600/" 1250/" Trib. Load Summary Tao Descriotion Load Tvne Ref. Sta¡t d 1 Standard Load Gontrols Summary Unf. Area (lb/ft^2) Value L 00-00-00 24-00-00 500 % Allowable Duration case 640 01-00-00 Locat¡on Pos. Moment Neg. Moment End Shear Cont. Shear Total Load Defl. Live Load Defl. Total Neg. Defl. Max Defl. Span / Depth Squash Blocks 6,538 ft-lbs -7,884 fHbs 2,882|bs 4,503|bs Lt721 (0.133") L/gee (0.07") L/e99 (-0.03e") 0.133" 10.1 Valid 03-04-09 08-00-00 00-1 0-06 16-11-04 03-08-01 03-1 0-06 't2-00-00 03-08-01 00-00-00 51 .9o/o 62.5o/o 45.60/o 71.3o/o 333% nla nla 133% nla lOOo/o 100% 100% 100% nla nla nla nla nla 2 4 2 5 2 7 2 2 0 Notes Entered/Displayed Horizontal Span Length(s) = Clear Span + 112 min. end bearing + 1/2 intermediate bearing Design meets Code minimum (Ll24O) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Minimum bearing length for B0 is 1-1l2". Minimum bearing length for 81 is 4". Minimum bearing length for 82 is 4". Minimum bearing length for 83 is 1-1l2". Calculations assume member is fully braced. Design based on Dry Service Condition. Fastener Manufacturer:TrussLok (tm) Page 1 of2 â"o'"""""""0"Double 1-314" x9-112" VERSA-LAM@ 2.0 2800 DF F Dry l3 spans I No cantilevers l0/'12 slope File Name: BC CALC Project Description: Designs\F801 Specifier: Designer: Company: Misc: Floor Beam\FB0l June 16, 2017 16:16:25 BC CALC@ Design Report Build 6036 Job Name: Address: City, State, Zip: , Customer: Code reports: ESR-1040 Connection Diaoram a Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code-accepted design properties and analysis methods. lnstallation of Boise Cascade engineered wood products must be in accordance with current lnstallation Guide and applicable building codes. To obtain lnstallation Guide or ask questions, please call (800)232-0788 before installation. BC CALC@, BC FRAMER@ , AJSIM, ALLJOIST@, BC RIM BOARDTM, BCI@, BOISE GLULAMTM, SIMPLE FRAMING SYSTEM@, VERSA-LAM@, VERSA-RIM PLUS@, VERSA-RIM@, VERSA-STRAND@, VERSA-STUD@ are trademarks of Boise Cascade Wood Products L.L.C. a minimum = 2" c= 5-112" bminimum=4" d=24" e minimum = 1" All TrussLok screws may be installed from one side of multiple ply VERSA-LAM beams All TrussLok screws may be installed from one side of multiply Versa-Lam beams. Member has no side loads. Connectors are: FMTSL338 6eoi"" cu"""a"Single 9-112" BCI@ 6000-1.8 DF Dry | 2 spans I No cantilevers | 0/12 slope 16 OCS I Non-Repetitive I Glued & nailed construction File Name: BC CALC Projecl Description : Designs\J01 Specifler: Designer: Company: Misc: Joist\J0l June 16, 2017 16:16:27 BC CALC@ Design Report Build 6036 Job Name: Address: City, State, Zip: , Customer: Code reports: ESR-1336 æ I 0-06-00 I 0-06-00 BO B1 Total Horizontal Product Length = 2l-00-00 82 Reaction Summary (Down / Uplift) ¡ lus ¡Bearino Live Dead Snow Wind Roof Live BO,2-1t2" 81,3-1t2" B2,2-1t2" 252 I 32 681 /0 252 I 32 2741O 8521O 2741O Live 100% Dead 90o/o Snow 11 Wnd Roof Live 16O0/" 125o/o ocs Load Summary Taq Description Load Rêf. Start End 1 Standard Load Controls Summary Unf. Area (lb/ft^2) Value L 00-00-00 21-00-00 40 % Allowable Duration Case 50 Location 16 Pos. Moment Neg. Moment End Reaction lnt. Reaction End Shear Cont. Shear Total Load Defl. Live Load Defl. Max Defl. Vibration Span / Depth Squash Blocks 1,077 ftlbs -1,502 ftlbs 526lbs 1,533 lbs 501 lbs 749lbs L/eeg (0.103) L/999 (0.054.) 0.103' 10'1-314" 13.1 Valid o4-04-o2 I 0-06-00 00-00-00 1 0-06-00 00-02-08 10-o7-12 04-1 1-06 15-1 1-01 04-1 1-06 00-00-00 00-00-00 344/o 47.5% 41 .2o/o 63.9% 31.8% 47.5% nla nla nla 59.5% nla 100% 100% lOOo/o lOOo/o lOOo/o lOOo/o nla nla nla nla nla 2 1 2 1 2 1 2 6 2 0 Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code-accepted design properties and analysis methods. lnstallation of Boise Cascade engineered wood products must be in accordance with current lnstallation Guide and applicable building codes. To obtain lnstallation Guide or ask questions, please call (800)232-0788 before installation. BC CALC@, BC FRAMER@ , AJSTM, ALLJOIST@ , BC RIM BOARDTM, BCI@, BOISE GLULAMTM, SIMPLE FRAMING SYSTEM@, VERSA-LAM@, VERSA-RIM PLUS@, VERSA-RIM@, VERSA-STRAND@, VERSA-STU D@ are trademarks of Boise Cascade Wood Products L.L.C. Bearinq Supports Dim. {L x w) value % AIIow Suooort % Allow Member Material B0 Wall/Plate 81 Beam 82 Wall/Plate 2-112" x2-5116" 3-112" x2-5116" 2-112" x2-5116" 526lbs 1,533 lbs 526lbs nla 25.2o/o nla 41.2% 63.9% 41.2% Unspecified Versa-Lam 1.7 Unspecified Vibration Summary Subfloor: 23132" OSB, Glue + Nail Strapping: None Gypsum Ceiling: None Bracing: None Notes Design meets Code minimum (L1240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1 ") Maximum Total load deflection criteria. Calculations assume member is fully braced. Composite El value based on 23132" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Page 1 of 1