Loading...
HomeMy WebLinkAbout1.0 ApplicationGørfield County PRE-APPLICATION CONFERENCE SUMMARYCommunity Development l)epartment 108 8th Street, Suite 401 Glenwood Springs, CO 81601 (970) 94s-8212 rvww. garf ield - c o u nty. c o m TAX PARGEL NUMBER: 2407-181-02-002 PROJECT: Valley View Commons Amended Final Plat OWNER: Darter LLC REPRESENTATIVE/PLANNER: Paul Johnson DATE: 02122118 Updated 3120118 PRACTICAL LOCATION: Adjacent to Stone Quarry Road, County Road 300, south of its intersection with West Battlement Parkway, County Road 300W, in the Battlement Mesa, and also known as Lot 47 of the Valley View Village Subdivision TYPE OF APPLICATION: Minor Subdivision ZONING: Battlement Mesa PUD, Mixed Use (MU) I. GENERAL PROJECT DESCRIPTION The Applicant is planning to develop a Dollar General Retail store on the Lot 47 of the Valley View Village Subdivision. The plan is to subdivide Lot 47 into two lots approximately 1.6 acres and 6.3 acres in size. The 1.6 acre lot would be the site of the proposed Dollar General Store. The proposed retail development is a permitted use in the Mixed Use Zone District within the PUD (pursuant to Resolution 2006-58). An existing Plat note restriction on Lot 47 reads as follows: Note: Lot 47, Future Development Lot 47 shall be subject to a resubdivision prior to the issuance of a building Permit on Lot 47. The proposed Minor Subdivision is intended to comply with the plat note and address subdivision issues on the entire 7.9 acre tract. Overall site grading and drainage, overall topography, flood plain, site reclamation, revegetation and protection from soil erosion, consistency with existing infrastructure and any required infrastructure extensions/connections, streetscape improvements, access considerations and driveways, will need to be addressed for the overall site. It is also anticipated that the Minor Subdivision submittals will provide general site plan information for the proposed retail use to include topics such as off-street parking, landscaping, pedestrian improvements, visual impacts, signage, and overall consistency with the Battlement Mesa PUD Zoning requirements. II. REGULATORY PROVISIONS APPLICANT IS REQUIRED TO ADDRESS The following Sections of the Garfield Land Use and Development Code are applicable to the proposed application: . Section 5-301 Minor Subdivision (including review criteria). Table 5-103 Common Review Procedures and Required Notice. Section 5-401 and Table 5-401 Submittal Requirements subject to waivers. Section 5-402 Description of Submittal Requirements including Final Plat. Section 4-103 Administrative Review (including public notice). Section 4-203 Description of Submittal Requirements (as applicable). Provisions of Article 7, Divisions1,2,3 and 4, as applicable including site planning and subdivision standards.. Section 4-202, Submittal Waivers and Section 4-118, Waivers from Standards as applicable or needed.. Subdivision Regulations of Garfield County of 1978 as adopted January 2, 1979, pursuant to the Battlement Mesa PUD Guide, including general application materials and Final Plat Requirements, and modifications as may be permitted by the Board of County Commissioners at the time of subdividing including the Minor Subdivision Process from the current Land Use and Development Code (see Section 11.0 Modification of Subdivision Regulations - Battlement Mesa PUD Guide). III. SUBMITTALREQUIREMENTS Outlined below is a list of information typically required for this type of Application. Use of the listing as a pre-submittal checklist is recommended. ! General Application Materials including copy of the application form, application fees, signed Payment Agreement Form.! Proof of Ownership (title work, copy of a deed) and information on any lien holders.! Statements of Authority, as applicable including authority to represent for LLC's or corporations! A narrative describing the request and related information.! Names and mailing addresses of properties within 200 ft. of the subject property, (including mapping is recommended). Mineral rights ownership for the subject property including mailing address. lnformation on how the mineral rights were researched also should be provided. ! lf owner intends to have a representative (Surveyor, Planner or Attorney) a letter of authorization to represent is needed. ! Copy of the Pre-application Summary needs to be submitted with the Application. ! Vicinity Map including areas within approximately 3 miles. ¡ The Proposed Minor Subdivision Plat showing the proposed lot lines and all easements existing and proposed including utility and access easements. ! Site Plan and related information including locations of any existing structures, significant features, flood plain, proposed access, water lines, sewer lines, etc. ! The site plan/plat should include improvement location information adequate to confirm that no nonconforming conditions will result from the proposed subdivision. ! A Water Supply Plan including tap information and/or will serve letters. Water service for both lots needs to be addressed. ! Waste Water Management Plan including tap information and/or will serve letters. Sewer service for both lots needs to be addressed. ! Preliminary Engineering reports/plans for Roads, Trails, Walkways and Bikeways. ! Preliminary Engineering reports/plans for Sewage and Water Supply Systems. ! Preliminary Engineering reports/plans for Groundwater Drainage. ! Preliminary cost estimates for improvements and/or any draft subdivision improvements agreement, as applicable. ! lnformation on other existing infrastructure including electric service. ! Any existing or proposed covenants on the property. ! The Application submittals need to include documentation on compliance with access driveway and parking standards for commercial development. n Additional review of access shall occur as part of the development review process including referral comments from the Fire Protection District and County Road and Bridge.! Referral to the Colorado Geological Survey (CGS) will occur and requires a supplemental fee, made payable to CGS. n Statements - Responses to the Minor Subdivision Review Criteria contained in Section 5-301.! General information and statements regarding conformance with standards in Article 7, Divisions 1,2,3 and 4, including but not limited to geologic hazards, water body setbacks, fire protection, wildlife habitat, Division 3, Site Planning and Development Standards and Division 4, Subdivision Standards. ! Waiver requests from submittal requirements or standards need to be included in the submittals and the waiver criteria clearly addressed (Sections 4-118 and 4-202). Additional follow-up meetings with staff are recommended to further discuss waiver options. The Application submittal needs to include 3 hard copies of the entire Application and 1 Digital PDF Copy of the entire Application (on a CD or USB Stick). Both the paper and digital copies should be split into individual sections. Please refer to the pre-application summary for submittal requirements that are appropriate for your Application. IV. REVIEW PROCESS The review process shall follow the steps contained in Table 5-103 and Section 4-103 for an Administrative Review including: Pre-Application meeting (completed) Submittal of Application (3 hard copies & one digital PDF copy) Completeness Review Additional Submittals if determined to be incomplete Setting a date for the Director's Decision - or referral to the Board of County Commissioners by the Director Referrals sent out to reviewing agencies including the Colorado Geological Survey Public Notice to Property Owners within 200 ft. and mineral rights owners on the subject property either for the Director's Decision or a public hearing before the Board of County Commissioners (if referred by the Director) Director's Decision or Board of County Commissioners public hearing 10 Day Call-up Period if decided by Director's Decision Preparation of a Board of County Commissioners resolution if referred to the Board Finalizing the Minor Subdivision Plat and any required conditions Circulation of the plat for Applicant & Other Signatures Board of County Commission Signing the plat as a consent agenda item A request to call the application up for review by the Board of County Commissioners may be initiated by the Director of the Community Development Department, the Board of County Commissioners, the Applicant or an affected Adjacent Property Owner in accordance with the procedures contained in Section 4-112. Staff anticipates that the Application will be referred up the Board of County Commissioners based on the Battlement Mesa PUD provisions. Public Hearing(s)X No Public Hearing, Directors Decision (with notice per code unless referred) _ Planning CommissionX Board of County Commissioners (if referred by the Director) _ Board of Adjustment Referral Agencies:May include but is not limited to: Garfield County Surveyor, Garfield County Attorney, Garfield County Building Department, Garfield County Consulting Engineer, Fire Protection District, Battlement Mesa Service Association, Battlement Mesa lnc., Valley View Commons Homeowners Association, Garfield County Vegetation Manager, Garfield County Road and Bridge. a a V. APPLICATION REVIEW FEES Planning Review Fees: Referral Agency Fees: Total Deposit: $400 $na $400 (separate fee required for CGS review) (additional hours are billed at hourly rate of $40.50) VI. GENERALAPPL¡CATIONPROCESSING The foregoing summary is advisory in nature only and is not binding on the County. The summary is based on current zoning, which is subject to change in the future, and upon factual representations that may or may not be accurate. This summary does not create a legal or vested right. The summary is valid for a six month period, after which an update should be requested. The Applicant is advised that the Application submittal once accepted by the County becomes public information and will be available (including electronically) for review by the public. Proprietary information can be redacted from documents prior to submittal. Pre-aoolication Su merv Preoared bv: ,r)"u Glenn Hartmann, Principal Planner 5 tu D ate Gørfuld Coanty Mlnor Subdivision Revlew Process (Section 5-301) CI (¡, E' EI .9ã 'E- l¡ È o E t\ ı o .Exo CLo- .Applicant has 6 months to submit application .10 buslness days to review ¡lf incomplete, 60 days to remedy deficiencies rMailed to adjacent property owners within 200 feet and mineral owners at least 15 days prior to decision date r21 day comment period rCall-up Period - within 10 days of Director's Decision .Applicant has 90 days to meet any conditions of approval Step 1 : Pre-application Conference Step 2: Applícation Submittal Step 3: Completeness Review Step 4: Scheclule Decisi<¡rr Date and Provide Notice Step 5: Referral Step 6:Evalution by Director Step 7: Director's Decision Planning Application Receipt Application Date Plan Case Type Parcel Number * Project Name Applicant / Owner * Project Address * City * Section-Township-Range * Subdivision Block Lot or Tract Zoning Owner Mailing Address * Owner Phone * Representative (Arch, Eng, etc.)* General Description * 05/16/2018 Subdivision Minor 240718102002 Valley View Commons Amended Final Plat Minor Subdivision Darter LLC Sec18, T07, R95 Battlement Mesa 18-07-95 Valley View Village Lot 47 PUD - Planned Unit Development 518 28 Rd #202A Grand Junction, CO 81505 970-248-8500 Paul Johnson, PJ Consulting Develop a dollar general retail store on Lot 47 of the Valley View Village Sub. Subdivide Lot 47 into the lots of approx. 1.6 acres and 6.3 acres. the 1.6 acre lot will be the site of the proposed dollar. The proposed retail development is a permitted use in the mixed use zone district of the PUD. Fees and Payments: Fee Name Fee Amount Total Fees Due: Payments: Date Pay Type Check Number Amount Paid Total Paid: Total Due: Special Notes Prefix Number Month * Year *(?) Plan Case Number * Received By: Application Fee 400.00$ 400.00$ 05/16/2018 Check 2125 400.00$ 400.00$ 0.00$ Permit Number Assignment MISA 8648 -05- 18- MISA-05-18-8648 BWinschell TABLE OF CONTENTS PRE-APPLICATION SUBMITTAL Minor Subdivision of Lot 47 of the Valley View Village Subdivision 1. Division of Land Application Form 2. Pre-Application Summary 3. Narrative a. Parcel # b. Address c. Practical Location d. Owner e. Legal Description f. Zoning g. Total Acres h. Proposed Lot 47-A i. Proposed Lot 47-B j. Existing Land Use k. Mineral Rights Ownership l. Utilities m. Parking n. Signage o. Landscaping p. Covenants q. Preliminary Cost Estimates r. Other Site Issues 4. Statement of Authority 5. Letter of Authorization 6. Colorado Geological Survey Submittal Form for Land-Use Reviews 7. Payment Agreement Form 8. Valley View Village 2003 Covenants 9. Title Commitment 10. Copy of Deed 11. Geotechnical Report 12. 200 ft. Report Map 13. 200 ft. Notification List 14. Mineral Ownership Search Method and Results 15. Landscape Plan 16. Vicinity Map 17. Engineering Report (Roads, Utilities, Drainage) 18. Will Serve Letters 19. Responses to Section 5-301 Minor Subdivision Review Criteria 20. Conformance with Subdivision Standards 21. Development Plans for Lot 47B PJ Consulting Land Development Consulting 2206 Crestline Ct., Grand Junction, CO 81507 Paul Johnson: 970-210-5555 Project Summary Narrative for Minor Subdivision of Lot 47 of the Valley View Village Subdivision 04/14/2018 We are applying for a Minor Subdivision application for the purpose of dividing Lot 47 of the Valley View Village Subdivision into two lots. We will then apply for a Building Permit to build a 9,100 sq. ft. Dollar General retail store on the smaller of the two lots. Parcel #: 2407-181-02-002 Address: Not yet assigned Practical location: Adjacent to Stone Quarry Road, County Road 300, south of its intersection with West Battlement Parkway, County Road 300W, in the Battlement Mesa P.U.D., and also known as Lot 47 of the Valley View Village Subdivision. Owner: Darter, LLC Legal Description: LOT 47 (FUTURE PHASE COMMERCIAL LOT), LOCATED IN A PARCEL OF LAND SITUATED IN SE1/4NE1/4 SECTION 18, TOWNSHIP 7 SOUTH, RANGE 95 WEST, OF THE 6TH PRINCIPAL MERIDIAN, COUNTY OF GARFIELD, STATE OF COLORADO Zoning: Battlement Mesa P.U.D., Mixed Use (MU). Zoning was established by Garfield County Resolution No. 2006-58, wherein it establishes “Uses by right: Retail establishments not exceeding 15,000 square feet of building area for each principal use, including grocery, dry goods, hardware, bakery, liquor, drug, florist, books and similar uses.” This project will comply with the Battlement Mesa P.U.D. zoning requirements, which have been stated to me by the Battlement Mesa P.U.D. Planning Committee Chair as follows: “try to blend in with the surrounding commercial developments.” Total present area: 7.993 acres of vacant land Proposed Lot 47A: 1.607 acres upon which we will build a 9,100 sq. ft. Dollar General retail store. Proposed Lot 47B: 6.381 acres for future development Project Summary Narrative 04/14/18 Page 2 Existing Land Use: Vacant land Utilities: Water and wastewater treatment are provided by the Battlement Mesa Metropolitan District: contact Steve Rippy. Electricity is provided by Holy Cross Energy of Glenwood Springs. We are working with their engineer, Kenton Berner, 970-947-5497, kberner@holycross.com. Per Kenton, Holy Cross will be providing a line extension from the electrical vault on the northwest corner of Lot 47. This extension will service both Lot47B and later, Lot 47A when it is developed. Parking: 40 off street parking spaces, including two handicapped spaces. Parking requirements per the 2006-58 Resolution call for one space per 200 sq. ft. of floor area. The Dollar General will have 7,343 sq. ft. of floor area, dictating a minimum of 37 parking spaces. Signage: The Dollar General store will have a monument sign in front similar in size to the Kum & Go monument sign on the corner of West Battlement Parkway and Stone Quarry Road. Landscaping: A landscape plan created by Ciavonne, Roberts & Associates, Landscape Architects of Grand Junction, is included with our application. The plan includes a shrub bed, with concrete edger, along Stone Quarry Road, that includes a 6’ walking path down the middle, shade trees, deciduous and evergreen shrubs. Covenants: We will be conforming to the Declaration of Covenants, Conditions and Restrictions or the Valley View Village Subdivision created on December 16, 2003, which are included in our submission. We will not be changing or amending these CC&R’s. Preliminary Cost Estimates: Electrical: Line extension from the north to the site and a site transformer - $35,000. Grading, drainage and site fill: $179,000. Landscaping - $17,000. Building Permit - $5,175. Road Impact for South District - $22,707. Water and Sewer Taps - $28,350. Other Site Issues: Overall site grading and drainage, overall topography, flood plain, site reclamation, revegetation and protection from soil erosion, consistency with existing infrastructure and any required infrastructure, access considerations and driveways are addressed in attached documents created by our engineering firm, High Country Engineering, Inc., of Glenwood Springs. ALTA Commitment (6-17-06) Commitment Page 1 Commitment Number: NCS-863205-CO First American Title Insurance Company First American Title Insurance Company - NCS 1125 17th Street, Suite 500 Denver, Colorado 80202 Phone: (303)876-1112 Fax:(877)235-9185 DATE: August 11, 2017 FILE NUMBER: NCS-863205-CO PROPERTY ADDRESS: 70,000 SF+- Southwest corner of, Battlement Mesa Parkway & Stone , Quarry Road, Battlement Mesa, CO OWNER/BUYER: Darter, LLC/Dorsey Development DG, L.L.C. YOUR REFERENCE NUMBER: 70,000 SF+- Southwest corner of Battlement Mesa Pa ASSESSOR PARCEL NUMBER: APN: 2407-181-02-002 PLEASE REVIEW THE ENCLOSED MATERIAL COMPLETELY AND TAKE NOTE OF THE FOLLOWING TERMS CONTAINED THEREIN: Transmittal: Revision No.: Schedule A: Schedule B - Section 1 Requirements: Schedule B - Section 2 Exceptions: Should you have any questions regarding these materials, please contact First American Title Insurance Company National Commercial Services at the above phone number. We sincerely thank you for your business. TO: First American Title Insurance Company National Commercial Services TITLE OFFICER:Jef Stanton 1125 17th Street, Suite 500 PHONE: (303)876-1112 Denver, Colorado 80202 FAX: (877)235-9185 E-MAIL: jstanton@firstam.com DELIVERY: E-MAIL ____________________________________________________________________________________________ TO: First American Title Insurance Company National Commercial Services ESCROW OFFICER: Sonya Bailey 1125 17th Street, Suite 500 PHONE: (303)876-1112 Denver, CO 80202 FAX: (877)235-9185 E-MAIL: sonyabailey@firstam.com DELIVERY: E-MAIL ____________________________________________________________________________________________ To: Integrated Development Group, LLC ATTN: Jay Wood 5435 Highland Road PHONE: (225)291-0339 Baton Rouge, LA 70808 MOBILE: FAX: E-MAIL: jwoodidg@gmail.com DELIVERY: E-MAIL ____________________________________________________________________________________________ ALTA Commitment (6-17-06) Commitment Page 2 Commitment Number: NCS-863205-CO First American Title Insurance Company To: First American Title Insurance Company National Commercial Services ATTN: Brian McDonald 1125 17th Street, Suite 500 PHONE: (303)876-1112 Denver, CO 80202 MOBILE: FAX: E-MAIL: brianmcdonald@firstam.com DELIVERY: E-MAIL ____________________________________________________________________________________________ = ALTA Commitment (6-17-06) Commitment Page 3 Commitment Number: NCS-863205-CO First American Title Insurance Company = ALTA Commitment Form COMMITMENT FOR TITLE INSURANCE Issued by First American Title Insurance Company First American Title Insurance Company, a Nebraska corporation ("Company"), for a valuable consideration, commits to issue its policy or policies of title insurance, as identified in Schedule A, in favor of the Proposed Insured named in Schedule A, as owner or mortgagee of the estate or interest in the land described or referred to in Schedule A, upon payment of the premiums and charges and compliance with the Requirements; all subject to the provisions of Schedules A and B and to the Conditions of this Commitment. This Commitment shall be effective only when the identity of the Proposed Insured and the amount of the policy or policies committed for have been inserted in Schedule A by the Company. All liability and obligation under this Commitment shall cease and terminate six (6) months after the Effective Date or when the policy or policies committed for shall issue, whichever first occurs, provided that the failure to issue the policy or policies is not the fault of the Company. The Company will provide a sample of the policy form upon request. IN WITNESS WHEREOF, First American Title Insurance Company has caused its corporate name and seal to be affixed by its duly authorized officers on the date shown in Schedule A. ALTA Commitment (6-17-06) Commitment Page 4 Commitment Number: NCS-863205-CO First American Title Insurance Company COMMITMENT FOR TITLE INSURANCE FORM SCHEDULE A 1. Effective Date: July 31, 2017 at 5:00 p.m. a. ALTA Owner's Policy (06-17-06) $350,000.00 Proposed Insured: Dorsey Development DG, L.L.C., a Louisiana limited liability company b. ALTA Loan Policy (06-17-06) $TBD Proposed Insured: A Lender To Be Determined 2. The estate or interest in the Land described or referred to in this Commitment is: Fee Simple 3. Title to the estate or interest in the Land is at the Effective Date vested in: Darter, LLC, a Colorado limited liability company 4. The Land referred to in this Commitment is described as follows: See Exhibit "A" attached hereto and made a part hereof. For informational purposes only: 70,000 SF+- Southwest corner of, Battlement Mesa Parkway & Stone , Quarry Road, Battlement Mesa, Colorado = ALTA Commitment (6-17-06) Commitment Page 5 Commitment Number: NCS-863205-CO First American Title Insurance Company = EXHIBIT A Commitment No.: NCS-863205-CO The land referred to in Schedule A is situated in the County of Garfield, State of Colorado and is described as follows: A portion of Lot 47 as shown on the Final Plat of Valley View Village Subdivision in Battlement Mesa PUD recorded as Reception No. 643044, County of Garfield, State of Colorado. NOTE: THE ABOVE LEGAL DESCRIPTION WILL BE AMENDED UPON SATISFACTION OF THE REQUIREMENTS HEREIN SET FORTH. For informational purposes only: APN: 2407-181-02-002 ALTA Commitment (6-17-06) Commitment Page 6 Commitment Number: NCS-863205-CO First American Title Insurance Company COMMITMENT FOR TITLE INSURANCE FORM SCHEDULE B SECTION ONE REQUIREMENTS The following requirements must be met: 1. Pay the agreed amounts for the interest in the land and/or the mortgage to be insured. 2. Pay us the premiums, fees and charges for the policy. 3. Payment of all taxes and assessments now due and payable. 4. Receipt by the Company of a true and accurate Legal Description prepared and certified by a licensed surveyor, of the property to be insured hereunder. This commitment is subject to further requirements and/or exceptions upon review. 5. Recordation of a Special Warranty Deed satisfactory to the Company, from Darter, LLC, a Colorado limited liability company, vesting fee simple title in and to Dorsey Development DG, L.L.C., a Louisiana limited liability company. 6. Recordation of a Deed of Trust satisfactory to the Company, from Dorsey Development DG, L.L.C., a Louisiana limited liability company, to the Public Trustee of Garfield County, for the benefit of the proposed insured lender. 7. Recordation of a Partial Release of the Deed of Trust from Darter, LLC, a Colorado limited liability company to the Public Trustee of Garfield County for the use of American National Bank to secure an indebtedness in the principal sum of $1,450,000.00, and any other amounts and/or obligations secured thereby, dated September 4, 2008 and recorded September 19, 2008 at Reception No. 756025, to release the property described herein. NOTE: Assignment of Deed of Trust to Realty Management Group, LLC, a Colorado limited liability company recorded October 10, 2011 at Reception No. 809093. 8. Receipt by the Company of the following documentation for Darter, LLC, a Colorado limited liability company: Operating Agreement, and all amendments thereto, if any. 9. Certificate of Good Standing issued by the Colorado Secretary of State for Darter, LLC, a Colorado limited liability company. NOTE: As of the effective date of this commitment, the above entity was found to be in Delinquent status with the Colorado Secretary of State. ALTA Commitment (6-17-06) Commitment Page 7 Commitment Number: NCS-863205-CO First American Title Insurance Company 10. Receipt by the Company of the following documentation for Dorsey Development DG, L.L.C., a Louisiana limited liability company: Operating Agreement, and all amendments thereto, if any. 11. Receipt by the Company of a satisfactory Final Affidavit and Indemnity, executed by Darter, LLC, a Colorado limited liability company. 12. Receipt by the Company of a satisfactory Final Affidavit and Indemnity, executed by Dorsey Development DG, L.L.C., a Louisiana limited liability company. 13. Evidence satisfactory to the Company that all assessments for common expenses due under the Covenants referred to in Schedule B, Section 2, have been paid. 14. Receipt by the Company of an ALTA/NSPS Land Title Survey, certified to First American Title Insurance Company, and in form and content satisfactory to the Company. The Company reserves the right to make further requirements and/or exceptions upon review of this survey. ALTA Commitment (6-17-06) Commitment Page 8 Commitment Number: NCS-863205-CO First American Title Insurance Company COMMITMENT FOR TITLE INSURANCE FORM SCHEDULE B SECTION TWO EXCEPTIONS Schedule B of the policy or policies to be issued will contain exceptions to the following matters unless the same are disposed of to the satisfaction of the Company: 1. Any facts, rights, interests or claims which are not shown by the Public Records, but which could be ascertained by an inspection of the Land or by making inquiry of persons in possession thereof. 2. Easements, or claims of easements, not shown by the Public Records. 3. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, and any facts which a correct survey and inspection of the Land would disclose, and which are not shown by the public records. 4. Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown in the Public Records. 5. Any and all unpaid taxes, assessments and unredeemed tax sales. 6. Water rights, claims or title to water, whether or not shown by the public records. 7. Right of way for ditches and canals as constructed by the authority of the United States, as reserved in United States Patent recorded January 15, 1918 in Book 71 at Page 612. 8. An easement for utilities and incidental purposes granted to Public Service Company of Colorado, as set forth in an instrument recorded May 25, 1960 in Book 326 at Page 128. 9. Terms, conditions, provisions, obligations, easements and agreements as set forth in the Right- of-Way Easement recorded September 22, 1980 in Book 556 at Page 412. 10. Any tax, lien, fee or assessment by reason of inclusion of subject property in the Battlement Mesa Water and Sanitation District, as evidenced by instrument recorded March 23, 1982 in Book 595 at Page 291, and Notice recorded April 23, 1983 in Book 597 at page 883. 11. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 82- 121 recorded October 20, 1982 in Book 610 at Page 445. 12. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 82- 327 recorded December 29, 1982 in Book 615 at Page 880. ALTA Commitment (6-17-06) Commitment Page 9 Commitment Number: NCS-863205-CO First American Title Insurance Company 13. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 02- 330 recorded December 29, 1982 in Book 615 at Page 886. 14. Covenants, conditions, restrictions, provisions, easements and assessments as set forth in Amended and Restated Declaration of Covenants, Conditions and Restrictions for Battlement Mesa recorded August 13, 1991 in Book 811 at Page 9, and First Amendment recorded November 21, 2001 at Reception No. 592295, Second Amendment recorded October 31, 2002 at Reception No. 613708, Third Amendment recorded August 26, 2003 at Reception No. 634973, Fourth Amendment recorded March 1, 2004 at Reception No. 647410, Fifth Amendment recorded April 25, 2005 at Reception No. 672848, and Sixth Amendment recorded January 13, 2006 at Reception No. 690448, but omitting any covenant or restriction based on race, color, religion, sex, handicap, familial status, or national origin, and any and all amendments, assignments, or annexations thereto. 15. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 2003-67 recorded September 15, 2003 at Reception No. 636574. 16. Terms, conditions, provisions, obligations and agreements as set forth in the Annexation Agreement recorded December 16, 2003 at Reception No. 643039. 17. Terms, conditions, provisions, obligations and agreements as set forth in the Subdivision Improvements Agreement recorded December 16, 2003 at Reception No. 643045, and Amendment No. 1 recorded May 24, 2004 at Reception No. 652574. NOTE: Escrow Agreement in connection therewith recorded May 24, 2004 at Reception No. 652573. NOTE: Acknowledgment of Satisfaction in connection therewith recorded May 3, 2005 at Reception No. 673424. 18. Easements, notes, covenants, restrictions and rights-of-way as shown on the plat of Valley View Village Subdivision in Battlement Mesa P.U.D., recorded December 16, 2003 at Reception No. 643044. 19. Covenants, conditions, restrictions, provisions, easements and assessments as set forth in Master Declaration of Covenants, Conditions and Restrictions for Valley View Village Subdivision in Battlement Mesa PUD recorded December 16, 2003 at Reception No. 643048, but omitting any covenant or restriction based on race, color, religion, sex, handicap, familial status, or national origin, and any and all amendments, assignments, or annexations thereto. NOTE: Supplemental Declaration in connection therewith recorded October 22, 2004 at Reception No. 662275. NOTE: Second Supplemental Declaration in connection therewith recorded January 30, 2005 at Reception No. 691345. NOTE: Technical Amendment in connection therewith recorded June 1, 2010 at Reception No. 786692. 20. Terms, conditions, provisions, obligations and agreements as set forth in the Trench, Conduit, and Vault Agreement recorded February 26, 2004 at Reception No. 647202. 21. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 2008-72 recorded June 6, 2008 at Reception No. 749987. ALTA Commitment (6-17-06) Commitment Page 10 Commitment Number: NCS-863205-CO First American Title Insurance Company 22. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 2009-51 recorded July 21, 2009 at Reception No. 771779. 23. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 2009-62 recorded September 9, 2009 at Reception No. 774676. 24. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 2009-68 recorded September 22, 2009 at Reception No. 775420. 25. Terms, conditions, provisions, obligations and agreements as set forth in the Resolution No. 2010-16 recorded April 7, 2010 at Reception No. 784389. 26. Existing leases and tenancies. = ALTA Commitment (6-17-06) Commitment Page 11 Commitment Number: NCS-863205-CO First American Title Insurance Company = EXHIBIT B Statement of Charges ALTA Extended Loan Policy $ Tax Certification $ = ALTA Commitment (6-17-06) Commitment Page 12 Commitment Number: NCS-863205-CO First American Title Insurance Company = CONDITIONS 1. The term mortgage, when used herein, shall include deed of trust, trust deed, or other security instrument. 2. If the proposed Insured has or acquired actual knowledge of any defect, lien, encumbrance, adverse claim or other matter affecting the estate or interest or mortgage thereon covered by this Commitment other than those shown in Schedule B hereof, and shall fail to disclose such knowledge to the Company in writing, the Company shall be relieved from liability for any loss or damage resulting from any act of reliance hereon to the extent the Company is prejudiced by failure to so disclose such knowledge. If the proposed Insured shall disclose such knowledge to the Company, or if the Company otherwise acquires actual knowledge of any such defect, lien, encumbrance, adverse claim or other matter, the Company at its option may amend Schedule B of this Commitment accordingly, but such amendment shall not relieve the Company from liability previously incurred pursuant to paragraph 3 of these Conditions and Stipulations. 3. Liability of the Company under this Commitment shall be only to the named proposed Insured and such parties included under the definition of Insured in the form of policy or policies committed for and only for actual loss incurred in reliance hereon in undertaking in good faith (a) to comply with the requirements hereof, or (b) to eliminate exceptions shown in Schedule B, or (c) to acquire or create the estate or interest or mortgage thereon covered by this Commitment. In no event shall such liability exceed the amount stated in Schedule A for the policy or policies committed for and such liability is subject to the insuring provisions and Conditions and Stipulations and the Exclusions from Coverage of the form of policy or policies committed for in favor of the proposed Insured which are hereby incorporated by reference and are made a part of this Commitment except as expressly modified herein. 4. This Commitment is a contract to issue one or more title insurance policies and is not an abstract of title or a report of the condition of title. Any action or actions or rights of action that the proposed Insured may have or may bring against the Company arising out of the status of the title to the estate or interest or the status of the mortgage thereon covered by this Commitment must be based on and are subject to the provisions of this Commitment. 5. The policy to be issued contains an arbitration clause. All arbitrable matters when the Amount of Insurance is $2,000,000 or less shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. You may review a copy of the arbitration rules at http://www.alta.org/. ALTA Commitment (6-17-06) Commitment Page 13 Commitment Number: NCS-863205-CO First American Title Insurance Company Privacy Information We Are Committed to Safeguarding Customer Information In order to better serve your needs now and in the future, we may ask you to provide us with certain information. We understand that you may be concerned about what we will do with such information - particularly any personal or financial information. We agree that you have a right to know how we will utilize the personal information you provide to us. Therefore, together with our subsidiaries we have adopted this Privacy Policy to govern the use and handling of your personal information. Applicability This Privacy Policy governs our use of the information that you provide to us. It does not govern the manner in which we may use information we have obtained from any other source, such as information obtained from a public record or from another person or entity. First American has also adopted broader guidelines that govern our use of personal information regardless of its source. First American calls these guidelines its Fair Information Values. Types of Information Depending upon which of our services you are utilizing, the types of nonpublic personal information that we may collect include: • Information we receive from you on applications, forms and in other communications to us, whether in writing, in person, by telephone or any other means; • Information about your transactions with us, our affiliated companies, or others; and • Information we receive from a consumer reporting agency. Use of Information We request information from you for our own legitimate business purposes and not for the benefit of any nonaffiliated party. Therefore, we will not release your information to nonaffiliated parties except: (1) as necessary for us to provide the product or service you have requested of us; or (2) as permitted by law. We may, however, store such information indefinitely, including the period after which any customer relationship has ceased. Such information may be used for any internal purpose, such as quality control efforts or customer analysis. We may also provide all of the types of nonpublic personal information listed above to one or more of our affiliated companies. Such affiliated companies include financial service providers, such as title insurers, property and casualty insurers, and trust and investment advisory companies, or companies involved in real estate services, such as appraisal companies, home warranty companies and escrow companies. Furthermore, we may also provide all the information we collect, as described above, to companies that perform marketing services on our behalf, on behalf of our affiliated companies or to other financial institutions with whom we or our affiliated companies have joint marketing agreements. Former Customers Even if you are no longer our customer, our Privacy Policy will continue to apply to you. Confidentiality and Security We will use our best efforts to ensure that no unauthorized parties have access to any of your information. We restrict access to nonpublic personal information about you to those individuals and entities who need to know that information to provide products or services to you. We will use our best efforts to train and oversee our employees and agents to ensure that your information will be handled responsibly and in accordance with this Privacy Policy and First American's Fair Information Values. We currently maintain physical, electronic, and procedural safeguards that comply with federal regulations to guard your nonpublic personal information. Information Obtained Through Our Web Site First American Financial Corporation is sensitive to privacy issues on the Internet. We believe it is important you know how we treat the information about you we receive on the Internet. In general, you can visit First American or its affiliates’ Web sites on the World Wide Web without telling us who you are or revealing any information about yourself. Our Web servers collect the domain names, not the e-mail addresses, of visitors. This information is aggregated to measure the number of visits, average time spent on the site, pages viewed and similar information. First American uses this information to measure the use of our site and to develop ideas to improve the content of our site. There are times, however, when we may need information from you, such as your name and email address. When information is needed, we will use our best efforts to let you know at the time of collection how we will use the personal information. Usually, the personal information we collect is used only by us to respond to your inquiry, process an order or allow you to access specific account/profile information. If you choose to share any personal information with us, we will only use it in accordance with the policies outlined above. Business Relationships First American Financial Corporation's site and its affiliates' sites may contain links to other Web sites. While we try to link only to sites that share our high standards and respect for privacy, we are not responsible for the content or the privacy practices employed by other sites. Cookies Some of First American's Web sites may make use of "cookie" technology to measure site activity and to customize information to your personal tastes. A cookie is an element of data that a Web site can send to your browser, which may then store the cookie on your hard drive. FirstAm.com uses stored cookies. The goal of this technology is to better serve you when visiting our site, save you time when you are here and to provide you with a more meaningful and productive Web site experience. -------------------------------------------------------------------------------- Fair Information Values Fairness We consider consumer expectations about their privacy in all our businesses. We only offer products and services that assure a favorable balance between consumer benefits and consumer privacy. Public Record We believe that an open public record creates significant value for society, enhances consumer choice and creates consumer opportunity. We actively support an open public record and emphasize its importance and contribution to our economy. Use We believe we should behave responsibly when we use information about a consumer in our business. We will obey the laws governing the collection, use and dissemination of data. Accuracy We will take reasonable steps to help assure the accuracy of the data we collect, use and disseminate. Where possible, we will take reasonable steps to correct inaccurate information. When, as with the public record, we cannot correct inaccurate information, we will take all reasonable steps to assist consumers in identifying the source of the erroneous data so that the consumer can secure the required corrections. Education We endeavor to educate the users of our products and services, our employees and others in our industry about the importance of consumer privacy. We will instruct our employees on our fair information values and on the responsible collection and use of data. We will encourage others in our industry to collect and use information in a responsible manner. Security We will maintain appropriate facilities and systems to protect against unauthorized access to and corruption of the data we maintain. Form 50-PRIVACY (9/1/10) Page 1 of 1 Privacy Information (2001-2010 First American Financial Corporation) ALTA Commitment (6-17-06) Commitment Page 14 Commitment Number: NCS-863205-CO First American Title Insurance Company DISCLOSURE STATEMENT Pursuant to C.R.S. 30-10-406(3)(a) all documents received for recording or filing in the Clerk and Recorder's office shall contain a top margin of at least one inch and a left, right and bottom margin of at least one-half of an inch. The Clerk and Recorder will refuse to record or file any document that does not conform to the requirements of this section. NOTE: If this transaction includes a sale of the property and the price exceeds $100,000.00, the seller must comply with the disclosure/withholding provisions of C.R.S. 39-22-604.5 (Nonresident withholding). NOTE: Colorado Division of Insurance Regulations 8-1-2 requires that "Every title insurance company shall be responsible to the proposed insured(s) subject to the terms and conditions of the title commitment, other than the effective date of the title commitment, for all matters which appear of record prior to the time of recording whenever the title insurance company, or its agent, conducts the closing and settlement service that is in conjunction with its issuance of an owner's policy of title insurance and is responsible for the recording and filing of legal documents resulting from the transaction which was closed. Pursuant to C.R.S. 10-11-122, the company will not issue its owner's policy or owner's policies of title insurance contemplated by this commitment until it has been provided a Certificate of Taxes due or other equivalent documentation from the County Treasurer or the County Treasurer's authorized agent; or until the Proposed Insured has notified or instructed the company in writing to the contrary. The subject property may be located in a special taxing district. A Certificate of Taxes due listing each taxing jurisdiction shall be obtained from the County Treasurer or the County Treasurer's authorized agent. Information regarding special districts and the boundaries of such districts may be obtained from the Board of County Commissioners, the County Clerk and Recorder, or the County Assessor. NOTE: Pursuant to CRS 10-11-123, notice is hereby given: This notice applies to owner's policy commitments containing a mineral severance instrument exception, or exceptions, in Schedule B, Section 2. A. That there is recorded evidence that a mineral estate has been severed, leased, or otherwise conveyed from the surface estate and that there is a substantial likelihood that a third party holds some or all interest in oil, gas, other minerals, or geothermal energy in the property; and B. That such mineral estate may include the right to enter and use the property without the surface owner's permission. NOTE: Pursuant to Colorado Division of Insurance Regulations 8-1-2, Affirmative mechanic's lien protection for the Owner may be available (typically by deletion of Exception no. 4 of Schedule B, Section 2 of the Commitment from the Owner's Policy to be issued) upon compliance with the following conditions: A. The land described in Schedule A of this commitment must be a single family residence which includes a condominium or townhouse unit. B. No labor or materials have been furnished by mechanics or material-men for purposes of construction on the land described in Schedule A of this Commitment within the past 6 months. C. The Company must receive an appropriate affidavit indemnifying the Company against un-filed mechanic's and material-men's liens. D. The Company must receive payment of the appropriate premium. ALTA Commitment (6-17-06) Commitment Page 15 Commitment Number: NCS-863205-CO First American Title Insurance Company E. If there has been construction, improvements or major repairs undertaken on the property to be purchased within six months prior to the Date of the Commitment, the requirements to obtain coverage for unrecorded liens will include: disclosure of certain construction information; financial information as to the seller, the builder and or the contractor; payment of the appropriate premium, fully executed Indemnity Agreements satisfactory to the company, and, any additional requirements as may be necessary after an examination of the aforesaid information by the Company. No coverage will be given under any circumstances for labor or material for which the insured has contracted for or agreed to pay. NOTE: Pursuant to C.R.S. 38-35-125(2) no person or entity that provides closing and settlement services for a real estate transaction shall disburse funds as a part of such services until those funds have been received and are available for immediate withdrawal as a matter of right. NOTE: C.R.S. 39-14-102 requires that a real property transfer declaration accompany any conveyance document presented for recordation in the State of Colorado. Said declaration shall be completed and signed by either the grantor or grantee. NOTE: Pursuant to CRS 10-1-128(6)(a), It is unlawful to knowingly provide false, incomplete, or misleading facts or information to an insurance company for the purpose of defrauding or attempting to defraud the company. Penalties may include imprisonment, fines, denial of insurance and civil damages. Any insurance company or agent of an insurance company who knowingly provides false, incomplete, or misleading facts or information to a policyholder or claimant for the purpose of defrauding or attempting to defraud the policyholder or claimant with regard to a settlement or award payable from insurance proceeds shall be reported to the Colorado division of insurance within the department of regulatory agencies. NOTE: Pursuant to Colorado Division of Insurance Regulations 8-1-3, notice is hereby given of the availability of an ALTA Closing Protection Letter which may, upon request, be provided to certain parties to the transaction identified in the commitment. Nothing herein contained will be deemed to obligate the company to provide any of the coverages referred to herein unless the above conditions are fully satisfied. Report of Geotechnical Engineering Evaluation Proposed Dollar General Stone Quarry Road and Battlement Parkway Battlement Mesa, Colorado 81635 Prepared for Dorsey Development Companies 129 Chartres St. New Orleans, Louisiana 70130 ATTN: Mr. Jay Wood Brian R. Jackson, E.I. Staff Engineer Prepared by Professional Service Industries, Inc. 1070 West 124th Avenue Suite 800 Westminster, Colorado 80234 Kyle R. Duitsman, P.E. December 22, 2017 Site Manager PSI Project 05321499 lfltertek. I Mr. Jay Wood Dorsey Development Companies 129 Chartres Street New Orleans, Louisiana 70130 Re: Project Number: 05321499 December 22, 2017 Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, Colorado 80234 Phone: {303} 424-5578 Fax: {303} 423-5625 Report of Geotechnical Engineering Evaluation Proposed Dollar General Southwest Corner of Stone Quarry Road and Battlement Parkway Battlement Mesa, Colorado 81635 Dear Mr. Wood: Professional Service Industries, Inc. (PSI), an lntertek Company, is pleased to transmit our Geotechnical Engineering Report which includes the field exploration and laboratory testing results, as well as site preparation and foundation design recommendations. If you have questions pertaining to this report, or if we may be of further service, please contact us at your convenience. We thank you for your business and we look forward to finding ways to grow our partnership, expand our services, and continue Building Better Together. Site Manager Reviewed by: �w Brian R. Jackson, E.I. Staff Engineer www.intertek.com/building Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 1 www.intertek.com/building TABLE OF CONTENTS EXECUTIVE SUMMARY ............................................................................................................................. 2 EXECUTIVE SUMMARY TABLE .................................................................................................................. 3 1.0 INTRODUCTION .................................................................................................................................. 4 2.0 PROJECT INFORMATION ..................................................................................................................... 4 3.0 SUBSURFACE INFORMATION .............................................................................................................. 5 3.1 SITE GEOLOGY AND GEOLOGIC HAZARDS ........................................................................................................ 5 3.2 SWELL POTENTIAL ...................................................................................................................................... 6 3. 3 SUBSURFACE CONDITIONS .......................................................................................................................... 6 3.3.1 Subsurface Profile .......................................................................................................................... 8 3.3.2 Groundwater Conditions ............................................................................................................... 8 3.3.3 Laboratory Testing ......................................................................................................................... 8 4.0 GEOTECHNICAL EVALUATION ............................................................................................................. 8 5.0 SITE GRADING RECOMMENDATIONS ................................................................................................. 9 5.1 ENGINEERED FILL ....................................................................................................................................... 9 5.2 GENERAL FILL PLACEMENT AND TESTING ...................................................................................................... 10 6.0 GEOTECHNICAL RECOMMENDATIONS .............................................................................................. 11 6.1 FOUNDATIONS ........................................................................................................................................ 11 6.2 SEISMIC PARAMETERS ............................................................................................................................... 12 6.3 PAVEMENT RECOMMENDATIONS ................................................................................................................ 13 7.0 LIMITATIONS .................................................................................................................................... 16 ATTACHMENTS Site Vicinity Map (Figure 1) Boring Location Map (Figure 2) Possible Fill Terrace (Figure 3) Boulder Stockpile (Figure 4) Boring Logs (Figures 5 through 14) Key to Symbols (Figure 15) Appendix A – Laboratory Test Results Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 2 www.intertek.com/building Executive Summary Dorsey Development Companies authorized PSI, an Intertek company, on November 10, 2017 to perform a geotechnical subsurface exploration near Stone Quarry Road and Battlement Parkway in Battlement Mesa, Colorado. Dorsey Development Companies is preparing the designs for a single-story Dollar General at this location. The current plans call for the approximately 9,100 square foot, rectangular shaped, single-story building to be constructed near the center of the site. The plans also include 37 parking spaces (standard duty concrete) and drive lanes (heavy duty concrete) to the east and south of the proposed building location. PSI encountered clay soil with varying amounts of sand and gravel underlain by basalt boulders and cobbles to the termination depths of our borings. The basalt boulders were found to persist across the site and were encountered at depths ranging from 3 to 9 feet below the existing ground surface. Surficial soils were dry, light brown and contained abundant calcareous nodules, and frequent basalt cobbles. Surficial soils were generally stiff to hard, sandy, and the clay was lean to fat. Groundwater was not encountered in the test borings at the time of drilling. Based on images from Google Earth, and observations made during our site investigation, the site appears to have undergone earthwork operations sometime between August 2006 and August 2011. Earthwork efforts likely included stripping of large boulders and debris at the surface, and grading of soils across the site, although the extent of earthwork operations is unknown. The subsurface exploration identified the existence of abundant large basalt boulders at depths ranging from approximately three to nine feet across the site. Large boulders may require extra excavation efforts where they are present in the subgrade at foundation depths. PSI recommends shallow foundations, slabs-on-grade and pavements be founded on at least 3 feet of moisture conditioned, compacted fill or recompacted suitable on-site soils, extending 5 feet beyond foundation limits. If on-site soils are used as moisture-conditioned and recompacted fill, any boulders and cobbles greater than 2 inches found in the subgrade 3 feet below the foundation footings, slabs-on-grade, or pavement should be removed. Dorsey Development Companies should not rely solely on this Executive Summary and must read and evaluate the entire contents of this report prior to utilizing PSI’s engineering recommendations in preparation of the project documents. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 3 www.intertek.com/building Executive Summary Table Summary Item: Summary Description: PSI Project Number: 05321499 Client Name: Dorsey Development Companies Project Name: Dollar General – Parachute, CO Project Location: Stone Quarry Road and Battlement Parkway Battlement Mesa, CO 81635 Lat – 39.43994; Long – -108.03108 (approx.) Project Description: 1-Story, Steel Framed, Slab-on-Grade Construction of 9,100 ft2 Retail Store Number of Borings Performed 5 for the building, 4 for the pavement, 1 additional to determine depth to boulders north of proposed building General Soils Description: Sandy Clay and Lean to Fat Clay with Cobbles underlain by Boulders and Cobbles Groundwater Conditions: Not Encountered Controlling Geotechnical Features: Excavation of large boulders to create a consistent subgrade under foundation footings and slab Recommended Foundation Scheme: Shallow foundations on 3 feet of modified on-site soils or Engineered Fill– minimum 18-inch continuous wall foundations or minimum 3 ft x 3 ft column footings Pavement Recommendations: Full-depth Portland Cement Concrete: 6 inches Other: Pavements and slabs should bear on at least 3 feet of scarified, moisture conditioned and recompacted soil Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 4 www.intertek.com/building 1.0 INTRODUCTION Professional Service Industries, Inc. (PSI), an Intertek company, has conducted a geotechnical engineering evaluation for the proposed Dollar General Store to be located in Battlement Mesa, Colorado. The purpose of our study was to characterize the subsurface strata at the subject site and to develop recommendations for site preparation, pavement, and foundation design for the proposed development. Our services on this project were performed in accordance with the General Agreement between PSI and Dorsey Development Companies, and was authorized by Dorsey Development Companies on November 10, 2017. The report, which follows, presents a brief review of our understanding of the project, a discussion of the site and subsurface conditions, and our recommendations. 2.0 PROJECT INFORMATION PSI understands that Dorsey Development Companies is planning the development of a Dollar General retail store to be located on currently vacant land located at the southwest corner of Stone Quarry Road and Battlement Parkway in Battlement Mesa, CO (See Figures 1 and 2). The latitude and longitude of the subject site is approximately 39.43994o North and 108.03108o West. The subject site lies on a portion of an undeveloped parcel of land that is approximately 1.61 acres. The parcel is bound by Battlement Parkway to the north, and Stone Quarry Road to the east. An ephemeral stream channel with a retaining structure supporting residential buildings is located south of the site and undeveloped land followed by Valley View Drive is located west of the site. The section of the parcel planned for development is vacant, and is believed to lie on approximately two to ten feet of graded soil with large boulders and debris stripped from the surface between 2006 and 2011 based on historical images in Google Earth. The graded and stripped material appears to increase in depth west of the proposed building footprint, and likely ends approximately 100 feet west of the westernmost edge of the proposed footprint, where an approximately 10 ft tall terrace is present (see Figure 3). Additionally, a large pile of basalt boulders and other debris is present approximately 350 feet west of the center of site, which likely is composed of material that was removed from the subgrade and dumped on site, between 2006 and 2011 (see Figure 4). The site slopes gently westward, and sits at an approximate elevation of 5,421 feet above msl. All longitude, latitude, and elevation data in this report were estimated in Google Earth, and are intended as approximate references. Project information is based on the preliminary site information provided by Dorsey Development Companies, including a conceptual site plan dated August 22, 2017, and PowerPoint slides with various site information and photos. Based on the information provided to PSI, we understand the proposed building has a footprint of 9,100 S.F. PSI understands that the proposed building will be a one-story, rectangular-shaped, masonry structure without a basement. The building will be located towards the center of the site and will have paved parking on the east and south sides of the building. Detailed structural loading information is not currently available; therefore, this report is based on the maximum column loads being less than 75 kips per column and maximum wall loads being Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 5 www.intertek.com/building less than 3 kips per linear foot, based on dead load plus live load for the building. Detailed site grading information has not been provided to PSI; however, this report is based on the finished floor elevation (FFE) for a building being constructed within 2-foot of the existing site grades. PSI should be provided actual grading plans prior to design finalization, so that we can review our recommendations and provide revised recommendations as necessary. The floor slab recommendations are based on a maximum floor load of 150 psf. PSI has based pavement design on an EDLA of 2 and 5 for standard and heavy duty pavements, respectively. Descriptions of the site are based upon observations made during our field exploration program. The geotechnical recommendations presented in this report are based upon the available project information and the subsurface materials described in this report. If any of the noted information is incorrect, please inform us so that we may amend the recommendations presented in this report, if needed. PSI’s scope of services for the geotechnical study did not include an assessment of environmental conditions in the soil, bedrock, surface water, groundwater, or air, on or below, or around this site. Any statements in this report or on the boring logs regarding odors, colors, and unusual or suspicious items or conditions are strictly for informational purposes. PSI performed a separate Phase 1 Environmental Site Assessment dated November 28, 2017 and found no evidence of Recognized Environmental Conditions. 3.0 SUBSURFACE INFORMATION The following sections provide information relating to subsurface conditions in the area of the proposed development. The geology section is based upon the, “Preliminary Geologic Map of the Grand Valley Quadrangle, Garfield County, Colorado,” by Donnell, J.R., Yeend, W.E., and Smith, M.C.dated 1986 and information relating to subsurface conditions within the property gathered from our current field study. 3.1 Site Geology and Geologic Hazards The site is located on the Colorado Plateau in the Western Slope of Colorado, approximately ¾ miles southeast of the Colorado River, in the census designated place (CDP) of Battlement Me sa. Based on the United States Geological Survey (USGS), “Preliminary Geologic Map of the Grand Valley Quadrangle, Garfield County, Colorado,” by Donnell, J.R., Yeend, W.E., and Smith, M.C. (1986) the site is mapped as being on Quaternary mudflow and fan gravel deposits, described as “pebble, cobble, and boulder gravel in a gray matrix of coarse sand; poorly sorted; clasts primarily unweathered basalt, but contain some sandstone, marlstone, siltstone and claystone. Derived largely from solifluction deposits east of quadrangle.” According to the map, the fan gravel deposits are underlain by the Tertiary Wasatch formation described as “variegated claystone with minor beds of fine to medium grained sandstone.” Google Earth shows that the existing residential area south of the site was constructed between 1993 and 2005, with additional development occurring between 2006 and 2011. Between 2006 and 2014, grading and stripping of boulders from the surface likely occurred on the site and surrounding area. The site is located approximately 100 feet north of an ephemeral stream Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 6 www.intertek.com/building tributary to the Colorado River, which lies approximately ¾ miles northwest of the site and flows southwest through the town of Parachute, Colorado. Additionally, Google Earth shows the existence of a gravel pit, approximately ¾ miles north-northwest of the site; it is unknown if the pit is currently active. Structures and equipment associated with oil and gas production are present approximately ½ miles southeast of the site. 3.2 Swell Potential PSI has reviewed “A Guide to Swelling Soils: Colorado Geologic Survey – Special Publication 43” by David C. Noe, Candace L. Jochim, and William P. Rogers dated 2007. Based on this publication, the subject site lies in or near areas containing “low to moderate” and “moderate to very high” swell potential. PSI performed Denver Swell Testing on selected samples collected during our field investigations. The following table summarizes the swell test results: General Test Boring Location Test Boring Depth below ground surface (feet) In-situ Moisture Content (%) Dry Density (pcf) Surcharge (psf) Swell Potential (%) Building NW Corner B1 2.5 11.3 87 250 -0.3 Building SW Corner B5 1.5 14.1 83 250 -0.3 West of Building B6 5 12.7 75 500 -1.2 Parking E B10 2.5 17.6 79 250 0.7 The laboratory swell test results are included in Appendix A and on the individual boring logs (Figures 5 through 14). The test results indicated swell percentages ranging from -1.2 percent to 0.7 percent, when tested under a 250 or 500 psf surcharge pressure. The surcharge values were applied based on the sample depth, in general. Once the samples were hydrated under the surcharge pressure and swelling had stopped, additional pressure was applied until the sample was at or below its initial volume. Based on the swell potential map and the laboratory results, PSI has classified the subgrade soils as having “Low” swell potential. Swell mitigation is not required for the proposed development. Should significant or larger cuts/fills be planned, risk of swell may increase as surcharges will change. Also, significant wetting and drying of soils will increase the risk of movement and should be prevented. 3. 3 Subsurface Conditions As part of PSI’s evaluation of this site, ten exploratory borings were drilled at the subject site as indicated on Figure 2, the Boring Location Map. Additional holes were drilled without taking soil samples to estimate the areal extent and depth of the basalt boulders and cobbles as previously mentioned (see Figure 2a). The following table displays the approximate boring locations and depths from the existing ground surface. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 7 www.intertek.com/building Boring(s) General Location Approximate Depth(s) Extended Below Existing Grades B1 Building NW Corner 4 ½ feet B2 Building SE Corner 4 ½ feet B3 Building Center 3 ½ feet B4 Building NE Corner 3 ½ feet B5 Building SW Corner 3 ½ feet B6 W of Building 9 ½ feet B7 Parking S 5 ½ feet B8 Parking SE 4 ½ feet B9 Parking E 3 ½ feet B10 Parking E 4 ½ feet The borings were advanced using a CME-55 truck-mounted drill rig equipped with 4-inch outside-diameter, solid-stem, and continuous-flight augers. Soil samples were recovered at selected depths during drilling using a Modified California Sampler (with an inside-diameter of 2.0 inches and an outside-diameter of 2.4 inches) driven by a 140-pound hammer free-falling 30 inches. The number of blows required to drive the sampler 12 inches is designated as the penetration resistance (N-value, blows per foot) and provides an indication of the consistency of cohesive soils and the relative density of granular materials. While the procedure is similar to that employed in the Standard Penetration Test (ASTM D1586), the penetration resistance obtained using the California barrel sampler is generally higher than that obtained using the standard split-spoon sampler. A correction factor of 0.6 for sand and 0.77 for clay is used for N- Values collected using the Modified California sampler. A PSI representative observed and documented the drilling of our borings and logs were prepared of the encountered conditions. Individual logs of the borings are presented on Figures 5 through 14. It should be noted that the subsurface conditions presented on the boring logs are only representative of the conditions at the specific locations drilled. Variations may occur and should be expected across the site. The stratification represents the approximate boundary between subsurface materials and the transitions may be gradual and indistinct. Water level information, if encountered, obtained during our field operations is also shown on the boring logs. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 8 www.intertek.com/building 3.3.1 Subsurface Profile From the surface in the test borings, light brown, dry, stiff to hard, lean to fat clay, with varying amounts of sand, gravel and cobbles, and abundant calcareous material (caliche) was encountered to a depth of approximately 3 to 9 feet below the existing ground surface (bgs) across the site. The surficial clay material is lean to fat, and is likely recompacted native soil with basalt boulders removed from the surface. The clay soil was underlain by gray to dark gray, very hard, basalt boulder and cobbles. Practical auger refusal was achieved approximately 6 inches into the boulders, and the termination depths of the test borings ranged from 3 ½ to 9 ½ feet. Fourteen additional borings were drilled to auger refusal within the building footprint and parking area to estimate the extent and depth to the basalt boulders; they were all terminated in the basalt at approximately 3 to 5 feet, consistent with the labeled test borings (see Figure 2). 3.3.2 Groundwater Conditions Groundwater was not observed to collect in any of the test borings at the time of drilling. Groundwater levels fluctuate during the year depending upon climatic and rainfall conditions and changes to surface topography and drainage patterns. Discontinuous zones of perched water may also exist, or develop. 3.3.3 Laboratory Testing The soil samples obtained during the field exploration were transported to the laboratory and selected soil samples were tested in the laboratory to determine material properties for our evaluation. Laboratory testing was accomplished in general accordance with ASTM and other applicable procedures. Laboratory testing was performed on selected samples to evaluate the classification and other engineering characteristics of the subsurface materials. Laboratory test data along with detailed descriptions of the soils can be found on the logs of borings and in Appendix A. The samples that were not altered by laboratory testing will be retained for 30 days from the date of this report and then will be discarded without further notice. 4.0 GEOTECHNICAL EVALUATION Large, very hard, boulders were observed in the subgrade, and at the surface surrounding the site during our site and subsurface evaluation. To create a consistent subgrade, the on-site boulders will require removal, and shallow foundations should bear on no less than 3 feet of engineered fill soils with 100% of material passing the 2-inch sieve. Additionally, pavements and slab-on-grades should bear on no less than 3 feet of scarified, moisture conditioned and recompacted on-site soil with 100% of material passing the 2-inch sieve, or imported structural fill material meeting the criteria described in section 5.1. Extra excavation efforts may be required to remove large boulders from the subgrade. Large boulders will likely be encountered during underground utility installation; utility trenches may require extra excavation efforts and shoring. On-site soils exhibited low swell potential. However, the design of the proposed Dollar General should take special care to limit the infiltration of water into the soils underlying the proposed Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 9 www.intertek.com/building Dollar General. This may include special measures to seal utilities and roof drains or make them flexible at critical locations to reduce the potential for the introduction of water into the subgrade materials. Perimeter drains should also be installed to minimize the inflow of surface water percolation into the soils under the proposed Dollar General. The allowable bearing capacity has been calculated using minimum footing widths of 18 inches, and for bearing depths of 1-½ and 3 feet below the existing grade. The potential movement through settlement of foundations has been estimated for the footing depths and can be found in Section 6.1 Foundations. Due to lean to fat clay expected in the upper 3 feet of the site, the recommended minimum pavement thicknesses for the subject development have been based on a subgrade support R- Value of 9 based on an AASHTO soils classification of A-6 obtained through laboratory analysis. The proposed pavement subgrade materials should be tested prior to construction to confirm this value. The following geotechnical design recommendations have been developed on the basis of the described project characteristics and subsurface conditions encountered. Once final design/grading plans and specifications are available, a general review by PSI is required as a means to check that the recommendations presented in the following sections of this report are properly interpreted and implemented. 5.0 SITE GRADING RECOMMENDATIONS Prior to excavation for foundation construction, the site should be stripped of vegetation, topsoil, loose uncompacted fill, soil stockpiles, and debris. If debris is encountered, it should be removed to the extent encountered and replaced with engineered fill. The stripped vegetation/topsoil may be re-placed as topsoil in designated landscape areas. Trash and debris should be disposed of in accordance with local and state regulations. The on-site soils should be undercut and removed to a depth of at least 3 feet below the proposed foundation and slab elements; material greater than 2 inches should be removed from the on-site soil, and the processed soil should be moisture-conditioned and recompacted as Engineered Fill, or replaced with approved imported Engineered Fill. Pavement areas should be scarified to a depth of 3 feet below final grade, moisture conditioned and recompacted with all material greater than 2 inches removed. This action will create a more consistent and suitable subgrade. 5.1 Engineered Fill Based on PSI’s field and laboratory data it is our opinion that the on-site overburden soils will be suitable for re-use as backfill soils and for use as structural fill, provided the material is properly, moisture conditioned and compacted with all material greater than 2 inches removed. If unanticipated material such as construction debris, trash, or other undesirable material is encountered during construction, they should be removed off site. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 10 www.intertek.com/building Imported structural fill, if required, should be free of organic or other deleterious materials, have a liquid limit less than 30, a plasticity index less than 10, and meet the following gradation outlined below. This structural fill criteria is intended as a general guideline. Imported structural fill materials should have a swell potential of less than 1 percent when compacted to 95 percent of maximum dry unit weight (MDUW) and at 2 percent below optimum moisture content (OMC) and tested under a swell test surcharge of 500 psf. The MDUW and OMC should be determined by ASTM D698 (Standard Proctor). Screen Size Percent Passing 2 Inch 100 #4 50 – 100 #200 10 - 30 Imported fill material proposed for use on this site that does not meet these criteria should be submitted to the project geotechnical engineer for evaluation and approval. The geotechnical engineer should evaluate the proposed import fill prior to purchase and delivery. Fine-grained soils used for fill require close moisture content control and careful placement by the contractor to achieve the recommended degree of compaction and to control swell potential and settlement. 5.2 General Fill Placement and Testing Unless otherwise specified, fill material should be compacted to at least 95 percent of the maximum dry unit weight as determined by the Standard Proctor Test (ASTM D 698). Each lift of compacted fill should be tested for density by a representative of the geotechnical engineer prior to placement of subsequent lifts. Sand fill soils should be moisture conditioned to between two percent below and two percent above optimum moisture content and clay fill soils should be moisture conditioned to a range from optimum moisture content to four percent above optimum moisture content. Fill material should be placed in maximum eight-inch loose lifts. A sample(s) of the proposed backfill soil(s) should be obtained for moisture density relationship (proctor test) three to four days prior to backfilling operations to expedite compaction and moisture content testing by the materials testing service provider. Weather conditions in the site area are typically dry in the summer and early fall. While grading can be inhibited for short periods during and following times of precipitation, grading can generally be conducted year-round. The major factor that must be considered during the winter months is ground freezing. During extended periods of sub-freezing weather, it can be difficult to properly moisture condition and compact soils. Grading must be conducted during the warmer parts of the day in freezing weather. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 11 www.intertek.com/building 6.0 GEOTECHNICAL RECOMMENDATIONS The proposed structure may be founded on continuous or individual column footings bearing on properly moisture conditioned and recompacted material. 6.1 Foundations PSI recommends that the proposed Dollar General structure be supported on continuous or individual column footings and should be designed for an allowable soil bearing pressure as shown in the following tables: Allowable Bearing Capacity of Continuous Footing (psf) Allowable Bearing Capacity Bearing Depth of Foundation Below Existing Grade 1½ feet 3,200 psf 3 feet 2,000 psf Allowable Bearing Capacity of Individual Column Pad (psf) Minimum 3 ft x 3 ft Allowable Bearing Capacity Bearing Depth of Foundation Below Existing Grade 1½ feet 4,000 psf 3 feet 2,300 psf The allowable bearing capacities provided above are based on a factor of safety of 3 and that the existing grade is at or near the proposed final grade elevation. Continuous footings supporting bearing walls should incorporate a minimum lateral dimension of 18 inches. Exterior column and wall footings should bear at a minimum of 36 inches below final grade for frost protection. Interior column and wall footings should be at a minimum of 18 inches below grade. The uplift capacity of shallow foundations should be limited to the weight of the foundation concrete plus the weight of the soil immediately above the footing. A concrete unit weight of 145 pcf should be used for design purposes. Lateral loads applied to the foundations will be resisted by a combination of passive pressure against the sides and friction along the base. For design purposes, based on a mobilized friction angle of 30o, PSI recommends using an equivalent fluid pressure of 43 pcf for the “active” case and 65 pcf for the “at-rest” case, along with a coefficient of friction of 0.39. A passive pressure of 195 pcf is recommended, based on a factor of safety of 2.0 to limit strain in the foundation. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 12 www.intertek.com/building Vertical movement through settlement of foundations were calculated to be less than 1 inch. Differential movements should be on the order of ½ inch or less between adjacent columns or along 20-feet of continuous footing length provided that the foundations are founded in moisture conditioned and compacted soils as described in the site preparation section of this report. The foundation excavations should be observed by a representative of PSI prior to reinforcing steel or concrete placement to assess that the foundation bearing materials are capable of supporting the design loads and are consistent with the materials discussed in this report. Soft or loose zones encountered at the bottom of the footing should be removed and replaced with properly compacted structural fill as directed by the geotechnical engineer. After the foundation bearing materials have been approved, steel reinforcement and concrete should be placed as quickly as possible to avoid exposure of the footing bottoms to wetting and drying. Surface run-off water should be drained away from the excavations and not be allowed to pond. If possible, the foundation concrete should be placed during the same day the excavation is made. If it is required that the excavation be left open for more than one day, they should be protected to reduce evaporation or entry of moisture. 6.2 Seismic Parameters The project site is located within Garfield County, which employs the International Building Code, 2015 edition. As part of this code, the design of structures must consider dynamic forces resulting from seismic events. These forces are dependent upon the magnitude of the earthquake event as well as the properties of the soils that underlie the site. As part of the procedure to evaluate seismic forces, the code requires the evaluation of the Seismic Site Class, which categorizes the site based upon the characteristics of the subsurface profile within the upper 100 feet of the ground surface. To define the Site Class for this project, we have interpreted the results of soil test borings drilled with the project site and estimated appropriate soil properties below the base of the borings to a depth of 100 feet, as permitted by Section 1615.1.1 of the code. The estimated soil properties were based upon data available in published geologic reports and our experience with subsurface conditions in the general site area. Based upon our evaluation, it is our opinion that the subsurface conditions within the site are consistent with the characteristics of Site Class C as defined in Table 1615.1.1 of the building code. The USGS-NEHRP interpolated probabilistic ground motion values near latitude 39.43994o North and 108.03108o West obtained from the USGS geohazards web page are as follows: Period (seconds) 2% Probability of Event in 50 years (%g) Site Coefficients Max. Spectral Acceleration parameters Design Spectral Acceleration parameters PGA 0.153 --- --- --- 0.2 (Ss) 0.275 Fa = 1.20 Sms = 0.330 SDs= 0.220 T0= 0.078 1.0 (S1) 0.076 Fv = 1.70 Sm1 = 0.128 SD1= 0.086 Ts= 0.391 Sms = FaSs SDs = ⅔*Sms T0= 0.2*SD1/SDs Sm1 = FvS1 SD1 = ⅔*Sm1 Ts= SD1/SDs Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 13 www.intertek.com/building The Site Coefficients, Fa and Fv presented in the above table were interpolated from IBC Tables 1615.1.2(1) and 1615.1.2(2) as a function of the site classification and mapped spectral response acceleration at the short (Ss) and 1 second (S1) periods. 6.3 Pavement Recommendations The following analysis and minimum pavement thickness recommendations are in general accordance with AASHTO, City of Parachute and Battlement Mesa, Colorado Department of Transportation Design Manual, and based upon our current understanding of the project. 6.3.1 Subgrade Preparation Recommendations To provide a more uniform subgrade for support of the proposed pavement sections, PSI recommends that the subsurface materials be scarified to a depth of 3 feet below final subgrade elevation and recompacted as moisture conditioned and compacted structural fill if the subgrade is consistent, and any material greater than 2 inches is removed. Once the subgrade below the parking area and drive lanes have been excavated, the existing site soils should be proofrolled to identify areas of loose soils prior to placement of moisture conditioned, compacted soils (either on-site or imported). The proofroll should be conducted with a loaded tandem-axle dump truck or similar pneumatic-tired equipment with a minimum weight of 15 tons and a maximum weight of 25 tons. 6.3.2 Minimum Pavement Thickness Recommendations Subsurface soils across the site were consistent, therefore, based on the lean to fat clay material encountered at the surface during our subsurface exploration, PSI has used an R-value of 9 for the support soils of the proposed pavement sections at both locations. Pavements will be designed to the minimum asphalt depth for this soil type. 6.3.2 Minimum Pavement Thickness Recommendations Based on the on-site soils, PSI has used an R-Value of 9 for support of the proposed pavement sections. PSI has identified two pavement categories based on anticipated traffic use and traffic loads. We have assigned estimated traffic loads to each category expressed in EDLA’s, where the EDLA is the equivalent daily load applications of vehicles relative to an 18-kip single axle load. We have also based this report on the following design criteria; a 20-year design life, a Pavement Serviceability Index (PSI) of 2.5 and a Reliability of 80%. • PSI has assigned an estimated EDLA of 2 for the general parking stall (Light-Duty Traffic) area. Anticipated traffic in this area includes private passenger vehicles or similar vehicles. • The drive lanes within the site have been assigned an estimated EDLA of 5 (Heavy-Duty Traffic - Drive Lanes), PSI anticipates that traffic in this area will be mixed use consist of delivery vehicles of varying size and weight and passenger vehicles. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 14 www.intertek.com/building Pavement section options are provided for full-depth asphalt, asphalt over aggregate base course, and rigid (Portland Cement Concrete) pavement. However, it is PSI’s experience that pavements with properly placed base aggregate on a properly drained grade outperform full- depth pavement sections. PSI strongly recommends using a composite section at this site to promote better drainage and to prevent significant moisture retention. Based on the stated assumptions, the following pavement sections are recommended, as presented below. RECOMMEND MINIMUM PAVEMENT SECTIONS Pavement Area Composite Section Full-Depth Asphalt Full-Depth Portland Cement Concrete Light-Duty (EDLA = 2) 4 inches Asphalt over 4 inches Aggregate Base Course 5 inches 5 inches* Heavy-Duty (EDLA = 5) 4 ½ inches Asphalt over 5 inches Aggregate Base Course 6 inches 5 inches *Minimum recommended depth Concrete pavement at least seven inches thick is recommended for the trash dumpster run-up due to the heavy wheel and impact loads that this area receives. The run-up should extend far enough away to support all wheels of the sanitation truck while stopped and in the loading position. Concrete pavement is also recommended in areas, which receive continuous repetitive traffic such as product unloading areas and parking lot entrances. 6.5.3 Flexible Pavement Allowances for proper drainage and proper material selection of base materials are most important for performance of asphaltic pavements. Ruts and birdbaths in asphalt pavement allow for quick deterioration of the pavement primarily due to saturation of the underlying base and subgrade. Hot bituminous pavement should meet the requirements as detailed for SuperPave Mixtures in Colorado Department of Transportation Standard Specifications for Road and Bridge Construction. Material meeting the Colorado Department of Transportation requirements for Grading SX (½ inch nominal) for top lift, and Grading S (¾ inch nominal) for the lower laye rs is recommended. In addition, the following are presented as general guidelines for properties of asphaltic concrete. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 15 www.intertek.com/building Flexible Pavement Areas Asphalt Cement PG 64-22 or PG 64-28 Asphalt Content As per mix design Percent Air Voids 3½-5 The minimal layer thickness shall be 2 inches and each layer should be a minimum of 2 times the aggregate size. Asphalt material should be obtained from an approved mix design stating the SuperPave Mixture properties, including optimum asphalt content, job mix formula, and recommended mixing and placing temperatures. Materials and construction methods should be in accordance with the CDOT Standard Specifications for Road and Bridge Construction Section 403. 6.5.4 Aggregate Base Course If aggregate base course is used as part of the pavement section, the materials should conform to CDOT requirements for Class 6 aggregate base course per Table 703-2 and construction methods should conform to Section 304 of the Colorado Department of Transportation Standard Specifications for Road and Bridge Construction. 6.5 Exterior Slab and Slabs-on-Grade A slab-on-grade floor slab and exterior slabs may be utilized for the proposed structure provided that the slab bears on no less than 36 inches of scarified, moisture-conditioned and recompacted reworked on-site soils. If the slab is placed on native, reworked soils, PSI recommends a subgrade support modulus (k- value) of 125-pci (based on a 1-foot square plate load test) be used for slab design. The value should be adjusted for larger areas using the following expression for cohesive and cohesionless soil: Modulus of Subgrade Reaction, ks = (B k ) for cohesive soil; and, ks = k (B B 2 1 )2 for cohesionless soil. where: ks = coefficient of vertical subgrade reaction for loaded area, k = coefficient of vertical subgrade reaction for 1x1 square foot area, B = width of area loaded, in feet. Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 16 www.intertek.com/building Where concrete slabs will be covered with tile or other moisture sensitive covering, we recommend the use of a vapor retarder beneath the slabs-on-grade to reduce vapor transmission through the slab. PSI recommends that a minimum four-inch thick free draining granular mat be placed beneath the floor slab to enhance drainage. The soil surface shall be graded to drain away from the proposed improvements without low spots that can trap water prior to placing the granular drainage layer. Polyethylene sheeting should be placed to act as a vapor retarder where the floor will be in contact with moisture sensitive equipment or product such as tile, wood, carpet, etc., as directed by the design engineer. The floor slabs should have an adequate number of joints to reduce cracking resulting from differential movement and shrinkage. The practices listed below are considered good construction practice and should be followed to prevent moisture content variation. • Cracking of slabs-on-grade can occur as a result of heaving or compression of the supporting soil, but also as a result of concrete curing stresses. The occurrence of concrete shrinkage cracks, and problems associated with concrete curing may be reduced and/or controlled by limiting the slump of the concrete, proper concrete placement, finishing, and curing, and by the placement of crack control joints at frequent intervals, particularly, where re-entrant slab corners occur. The American Concrete Institute (ACI) recommends a maximum panel size (in feet) equal to approximately three times the thickness of the slab (in inches) in both directions. For example, joints are recommended at a maximum spacing of 12 feet assuming a four-inch thick slab. We also recommend that control joints be scored three feet in from and parallel to all foundation walls. Using fiber reinforcement in the concrete can also control shrinkage cracking. • Some increase in moisture content is inevitable as a result of development and associated landscaping. However, extreme moisture content increases can be largely controlled by proper and responsible site drainage, site maintenance and irrigation practices. Proper slope away from the proposed canopy and walkways (5 to 10 percent) should be maintained. • All utility backfill in areas supporting slabs should be moisture-conditioned or dried by scarification, and compacted. Backfill in all interior and exterior water and sewer line trenches (if applicable) should be uniformly compacted. Exterior slabs should be isolated from the building. These slabs should be reinforced to function as independent units. Movement of these slabs should not be transmitted to the building foundation or superstructure. 7.0 LIMITATIONS The recommendations submitted are based upon the available subsurface information obtained by PSI and design details furnished by Dorsey Development Companies. If there are any revisions to the plans for this project or if deviations from the subsurface conditions noted in this report are encountered during construction, PSI should be notified immediately to Project Number: 05321499 Dollar General – Parachute, CO December 22, 2017 Page 17 www.intertek.com/building determine if changes in the foundation recommendations are required. If PSI is not retained to perform these functions, PSI will not be responsible for the impact of those conditions on the project. The geotechnical engineer warrants that the findings, recommendations, or professional advice contained herein have been made in accordance with generally accepted professional geotechnical engineering practices in the local area. No other warranties are implied or expressed. After the plans and specifications are more complete, the geotechnical engineer should be retained and provided the opportunity to review the final design plans and specifications to confirm that recommendations have been properly incorporated into the design documents. At the time, it may be necessary to submit supplementary recommendations. This report has been prepared for the exclusive use of Dorsey Development Companies and their consultants for the specific application to the Proposed Dollar General to be located at Stone Quarry Road and Battlement Parkway in Battlement Mesa, Colorado 81635. Taken From Google Earth DG - Parachute Site Vicinity Map 1a JOB NO. 5321499 FIGURE NO. N Site Taken From USGS Map - DG - Parachute Site Vicinity Map 1b JOB NO. 5321499 FIGURE NO. Site N Indicates Approximate location of Boring Hole Drilled to Auger Refusal, No Samples Taken Taken From Google Earth DG - Parachute Boring Location Map 2a JOB NO. 5321499 FIGURE NO. N B10 B9 B8B7 B6 B1 B4 B3 B5 B2 Basalt Boulder Pile Drainage Approximate Location of Terrace Indicates Approximate location of Boring Taken from Proposal Documentation DG - Parachute Boring Location Map 2b JOB NO. 5321499 FIGURE NO. B1 B2 B3 B4 B5 N B6 B7 B8 B9 B10 Taken During Site Visit Dollar General - Parachute, CO Likely Man-made Fill Terrace 3 JOB NO. 5321499 FIGURE NO. Taken During Site Visit Dollar General - Parachute, CO Basalt Boulder Stockpile 4 JOB NO. 5321499 FIGURE NO. 1 12 15-35 N=50 SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Very Stiff, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 4 1/2 feet) CL-CH Boulders 12 DD = 87 pcf S(250) = -0.3% PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5420 LATITUDE:39.44009° LONGITUDE:-108.03112° FIGURE: 5 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 4.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5421 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B1 1 12 9-14 N=23 SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Stiff, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 4 1/2 feet) CL-CH Boulders 15 DD = 85 pcf LL = 58 PL = 26 PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5420 LATITUDE:39.43981° LONGITUDE:-108.03098° FIGURE: 6 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 4.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5423 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B2 >> 1 12 12-19 N=31 SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Very Stiff, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 3 1/2 feet) CL-CH Boulders 27 Gradation: -200 = 50.2% PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5420 LATITUDE:39.43995° LONGITUDE:-108.03106° FIGURE: 7 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 3.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5421 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B3 1 11 50/11" SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Hard, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 3 1/2 feet) CL-CH Boulders 12 DD = 86 pcf -200 = 52.1% PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5420 LATITUDE:39.44033° LONGITUDE:-108.03097° FIGURE: 8 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 3.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5421 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B4 >> 1 8 50/8" SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Hard, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 3 1/2 feet) CL-CH Boulders 14 DD = 83 pcf S(250) = -0.3% PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5420 LATITUDE:39.43984° LONGITUDE:-108.03113° FIGURE: 9 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 3.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5422 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B5 >> 1 12 12-19 SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Very Stiff, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Stiff, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 9 1/2 feet) CL-CH Boulders 13 DD = 75 pcf S(500) = -1.2% PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5415 LATITUDE:39.43994° LONGITUDE:-108.03133° FIGURE: 10 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 9.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5420 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 5 DATE COMPLETED:11/30/17 BORING B6 >> 1 12 11-18 N=29 SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Very Stiff, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 5 1/2 feet) CL-CH Boulders 11 LL = 38 PL = 24 PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5420 LATITUDE:39.43969° LONGITUDE:-108.03109° FIGURE: 11 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 5.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5422 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 5 DATE COMPLETED:11/30/17 BORING B7 1 12 50/11" LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Hard, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 4 1/2 feet) CL-CH Boulders 21 DD = 89 pcf Gradation: -200 = 87.9% PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay LATITUDE:39.43967° LONGITUDE:-108.03082° FIGURE: 12 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 4.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5425 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B8 >> 1 0 Bounce SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Hard, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 4 1/2 feet) CL-CH Boulders PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay LATITUDE:39.43986° LONGITUDE:-108.03077° FIGURE: 13 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 3.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5424 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B9 >> 1 9 50/9" SANDY LEAN TO FAT CLAY (CL-CH) Light Brown, Dry, Hard, with trace Basaltic Cobbles, with Adundant Calcarous Nodules and Caliche at 2 feet. BOULDERS AND COBBLES Gray to Dark Gray, Dry, Very Hard, Clasts are Basaltic with Trace to Adundant Vesicles (Auger Refusal at 4 1/2 feet) CL-CH Boulders 18 DD = 79 pcf S(1000) = 0.7% PROJECT NO.:05321499 PROJECT:Dollar General - Parachute, CODepth, (feet)STRENGTH, tsf Additional Remarks USCS Classification0 QpSample Type2.0 0 Moisture, %MoistureMATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft QuSample No.Graphic Log50 PL Elevation (feet)LL 4.0 25 Recovery (inches)N/A While Drilling Upon Completion Delay 5420 LATITUDE:39.44007° LONGITUDE:-108.03078° FIGURE: 14 LOCATION:Stone Quarry Road and Battlement Parkway NA Not Encountered WaterREMARKS: DRILLER:Rocky Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Parachute, CO SAMPLING METHOD:Modified California DATE STARTED:11/30/17 BENCHMARK:N/A The stratification lines represent approximate boundaries. The transition may be gradual.Sheet 1 of 1 DRILL COMPANY:Dakota Drilling STATION:N/A OFFSET:N/A LOGGED BY:BRJ COMPLETION DEPTH 4.5 ft DRILL RIG:CME-55 DRILLING METHOD:Solid Stem Auger ELEVATION:5423 ft REVIEWED BY:KD EFFICIENCY N/A See Figure 2 HAMMER TYPE:Manual BORING LOCATION: 0 DATE COMPLETED:11/30/17 BORING B10 >> Professional Service Industries, Inc. USCS Low to High Plasticity Clay Boulders and cobbles KEY TO SYMBOLS PSI Job No.: Project: Location: 05321499 Dollar General - Parachute, CO Stone Quarry Road and Battlement Parkway Parachute, CO Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Fax: (303) 423-5625 SSA = Solid Stem Auger HSA = Hollow Stem Auger CFA = Continuous Flight Auger SPT = Standard Penetration Test MC - Modified California Sampler SS = Split-spoon Sampler ST = Shelby Tube Sampler RC = Rock Core DD = Dry Density MC = Moisture Content LL = Liquid Limit PL = Plastic Limit --200 = Percent Passing th No. 200 Sieve (%) S(250) = Swell under 250 psf surcharge pressure (%) S(500) = Swell under 500 psf surcharge pressure (%) S(1000) = Swell under 1000 psf surcharge pressure (%) Qu = Unconfined Compressive Strength RQD = Rock Quality Designation REC'D = Rock Core Recovery Percentage PID = Photo Ionic Detector (ppm) The borings were advanced into the ground using 4-inch solid stem augers. At regular intervals throughout the boring depths, soil samples were obtained with either a 1.4-inch I.D., 2.0-inch O.D., split-spoon sampler or a 2.0-inch I.D., 2.4-inch O.O.D. Modified California sampler. The samplers were first seated 6-inches to penetrate any loose cuttings and then drivan additional foot where possible with blows of a 140-pound hammer falling 30-inches. The number of hammer blowsrequired to drive the sampler each 6-inch increment is recorded in the field. The penetration resistance "N-value" isredesignated as the number of hammer blows required to drive the sampler the final foot and, when properly evaluated, isan index to cohesion for clays and relative density for sands. The split-spoon sampling procedures used during thisexploration are in general accordance with ASTM Designation D 1586. Appendix A Laboratory Test Results 87 pcf 2.5 feet 11.6 % Sample Description -0.3 % USCS Classification NA JOB NO. FIGURE NO. DG - Parachute SWELL - CONSOLIDATION TEST 5321499 A-1 Volume Change Swell Pressure Sample Location Sample Depth Dry DensityB1 In-Situ Moisture Content CL - CH Sandy Lean to Fat Clay -2 -1 0 1 2 100 1000 SWELL-CONSOLIDATION TEST SWELL PRESSURE (PSF)PERCENT SWELL / CONSOLIDATION (%) 83 pcf 1.5 feet 14.1 % Sample Description -0.3 % USCS Classification NA JOB NO. FIGURE NO. DG - Parachute SWELL - CONSOLIDATION TEST 5321499 A-2 Volume Change Swell Pressure Sample Location Sample Depth Dry DensityB5 In-Situ Moisture Content CL - CH Sandy Lean to Fat Clay -2 -1 0 1 2 100 1000 SWELL-CONSOLIDATION TEST SWELL PRESSURE (PSF)PERCENT SWELL / CONSOLIDATION (%) 75 pcf 5 feet 12.7 % Sample Description -1.2 % USCS Classification NA JOB NO. FIGURE NO. DG - Parachute SWELL - CONSOLIDATION TEST 5321499 A-3 Volume Change Swell Pressure Sample Location Sample Depth Dry DensityB6 In-Situ Moisture Content CL - CH Sandy Lean to Fat Clay -2 -1 0 1 2 100 1000 SWELL-CONSOLIDATION TEST SWELL PRESSURE (PSF)PERCENT SWELL / CONSOLIDATION (%) 79 pcf 2.5 feet 17.6 % Sample Description 0.7 % USCS Classification 800 psf JOB NO. FIGURE NO. DG - Parachute SWELL - CONSOLIDATION TEST 5321499 A-4 Volume Change Swell Pressure Sample Location Sample Depth Dry DensityB10 In-Situ Moisture Content CL - CH Sandy Lean to Fat Clay -2 -1 0 1 2 100 1000 10000 SWELL-CONSOLIDATION TEST SWELL PRESSURE (PSF)PERCENT SWELL / CONSOLIDATION (%) US SIEVE OPENING IN INCHES HYDROMETER GRAVEL SAND COBBLES COARSE FINE CRS MED FINE SILT OR CLAY Specimen I.D. Description USCS AASHTO Group Index LL PI PL B3 @ 2.5 FEET CL A-6 4 38 14 B8 @ 2.5 FEET CH A-7-6 31 58 32 Specimen I.D.D100 D60 D30 D10 Cc Cu %Gravel %Sand %Silt&Clay B3 @ 2.5 FEET 19.00 0.16 12 37 B8 @ 2.5 FEET 9.50 2 10 JOB NO. Fat Clay 26 GRADATION CURVES 5321499 A-5 FIGURE NO. Sandy Lean Clay 50 US SIEVE NUMBERS Dollar General - Parachute, CO 24 88 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.11101001000 GRAIN SIZE (mm) % F I N E R by W E I G H T 1.5 3/4 3/8 4 10 16 30 40 100 200 0 10 20 30 40 50 60 0 20 40 60 80 100 LL PSI Job No.: Project: Location: 05321499 Dollar General - Parachute, CO Stone Quarry Road and Battlement Parkway Parachute, CO Fines P L A S T I C I T Y I N D E X CL 2.5 2.5 32 14 58 38 PI CH CL-ML Classification (*Visual) ML Boring Depth (ft)PL LIQUID LIMIT MH B2 B7 ATTERBERG LIMIT RESULTS 26 24 Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Fax: (303) 423-5625 Fat Clay (CH) Lean Clay (CL) PJ Consulting Land Development Consulting 2206 Crestline Ct., Grand Junction, CO 81507 Paul Johnson: 970-210-5555 Mineral Rights Search Results Minor Subdivision of Lot 47 of the Valley View Village Subdivision For Parcel #: 2407-181-02-002 On May 2, 2018, I went to Garfield County’s Assessor’s office and met with Casey Lawrence, GIS Technician and Minerals Clerk. Casey researched his county records and found that no mineral rights document has been issued for this parcel, and therefore, there is no active mineral ownership for this parcel. Paul Johnson Parcel Physical Address 240717200001 Not available PARACHUTE 240717200005 124 STONE QUARRY RD PARACHUTE 240717206001 300 COUNTY RD PARACHUTE 240717212002 Not available PARACHUTE 240718100001 300 COUNTY RD PARACHUTE 240718100004 1230 W BATTLEMENT PKWY PARACHUTE 240718102001 Not available PARACHUTE 240718102002 Not available PARACHUTE 240718102003 Not available PARACHUTE 240718102004 Not available PARACHUTE 240718102005 Not available PARACHUTE 240718104024 BRYAN LOOP PARACHUTE 240718105001 51 ANGELICA CIR PARACHUTE 240718105002 53 ANGELICA CIR PARACHUTE 240718105003 57 ANGELICA CIR PARACHUTE 240718105004 59 ANGELICA CIR PARACHUTE 240718107001 111 ANGELICA CIR PARACHUTE 240718107002 113 ANGELICA CIR PARACHUTE 240718107003 117 ANGELICA CIR PARACHUTE 240718107004 119 ANGELICA CIR PARACHUTE 240718108001 31 ANGELICA CIR PARACHUTE 240718108002 37 ANGELICA CIR PARACHUTE 240718108003 33 ANGELICA CIR PARACHUTE 240718108004 41 ANGELICA CIR PARACHUTE 240718108005 35 ANGELICA CIR PARACHUTE 240718108006 39 ANGELICA CIR PARACHUTE 240718109001 81 ANGELICA CIR PARACHUTE 240718109002 87 ANGELICA CIR PARACHUTE 240718109003 83 ANGELICA CIR PARACHUTE 240718109004 89 ANGELICA CIR PARACHUTE 240718109005 85 ANGELICA CIR PARACHUTE 240718109006 91 ANGELICA CIR PARACHUTE ROW Not available null ROW Not available null Owner Account Num U S WEST COMMUNICATIONS, INC R490001 GRAND VALLEY FIRE PROTECTION DISTRICT R045260 GRAND VALLEY CEMETERY DISTRICT R470001 HURD PARACHUTE LLC R084049 BOARD OF COUNTY COMMISSIONERS GARFIELD COUNTY R400439 BMA WILLOW PARK LLC R470033 VALLEY VIEW VILLAGE HOMEOWNERS ASSOCIATION R040979 DARTER LLC R040980 VALLEY VIEW VILLAGE HOMEOWNERS ASSOCIATION R040981 VALLEY VIEW VILLAGE HOMEOWNERS ASSOCIATION R040982 VALLEY VIEW VILLAGE HOMEOWNERS ASSOCIATION R040983 VALLEY VIEW VILLAGE HOMEOWNERS ASSOCIATION R043097 HARLAN, RANDY G & KARLA K R041922 HARLAN, RANDY G & KARLA K R041923 KROEKER, CAROLE DAWN R041924 KROEKER, CAROLE DAWN R041925 WINN, MARTIN W R042061 ALVIR, JERRY R042062 REINERS, MERLE E R042063 REINERS, MERLIN R042064 PAVLIN, STEVE R & DIANE J R042823 J&J CAL LLC R042824 PAVLIN, STEVE R & DIANE J R042825 VIRAMONTES, MIGUEL GONZALEZ & GONZALEZ, CARMEN DEISY R042826 DITTMAR, DWIGHT R042827 WORLD PROPERTIES LLC R042828 BARR, RAYMOND R044168 KOZUCH, MARK D R044169 BARR, RAYMOND R044170 KRAKE, PAMELA KAYE & KEITH LAWRENCE R044171 KOZUCH, MARK D R044172 FALK, DANIEL T JR & ANNA M R044173 Mailing Address 6300 S SYRACUSE WAY, SUITE 700 ENGLEWOOD, CO 80111-6727 124 STONE QUARRY ROAD PARACHUTE, CO 81635 PO BOX 103 PARACHUTE, CO 81635-0103 2000 FULLER ROAD WEST DES MOINES, IA 50265 108 8TH STREET, SUITE 213 GLENWOOD SPRINGS, CO 81601-3363 2550 TELEGRAPH ROAD, SUITE 200 BLOOMFIELD HILLS, MI 48302 786 VALLEY COURT GRAND JUNCTION, CO 81505 518 28 RD STE A202 GRAND JUNCTION, CO 81501 786 VALLEY COURT GRAND JUNCTION, CO 81505 786 VALLEY COURT GRAND JUNCTION, CO 81505 786 VALLEY COURT GRAND JUNCTION, CO 81505 786 VALLEY COURT GRAND JUNCTION, CO 81505 PO BOX 712 SILT, CO 81652 PO BOX 712 SILT, CO 81652 479 MESA VIEW WAY GOLDEN, CO 80403 479 MESA VIEW WAY GOLDEN, CO 80403 PO BOX 141 GLENWOOD SPRINGS, CO 81602-0141 421 29 1/2 ROAD GRAND JUNCTION, CO 81504-6439 3455 F ROAD CLIFTON, CO 81520 3455 F ROAD CLIFTON, CO 81520 PO BOX 1003 CARBONDALE, CO 81623 2226 VILLAGE COURT GRAND JUNCTION, CO 81507 PO BOX 1003 CARBONDALE, CO 81623 858 UTE CIRCLE NEW CASTLE, CO 81647 35 ANGELICA CIRCLE UNIT 2C PARACHUTE, CO 81635 362 MAIN STREET SUITE B GRAND JUNCTION, CO 81501 81 ANGELICA CIRCLE PARACHUTE, CO 81635 16654 US HIGHWAY 41 #3A SPRING HILL, FL 34610-3734 81 ANGELICA CIRCLE PARACHUTE, CO 81635 1164 BARRINGTON AVENUE ROSAMOND, CA 93560 345 LESLIE DRIVE HALLANDALE, FL 33009-7310 91 ANGELICA CIRCLE PARACHUTE, CO 81635 PJ Consulting Land Development Consulting 2206 Crestline Ct., Grand Junction, CO 81507 Paul Johnson: 970-210-5555 Will Serve Letters Minor Subdivision of Lot 47 of the Valley View Village Subdivision Electrical Service: Electricity is provided by Holy Cross Energy of Glenwood Springs. We are working with their engineer, Kenton Berner, 970-947-5497, kberner@holycross.com. Per Kenton, Holy Cross will be providing a line extension from the electrical vault on the northwest corner of Lot 47. This extension will service both Lot47B and later, Lot 47A when it is developed. Water and Sanitary Sewer: Water and wastewater treatment are provided by the Battlement Mesa Metropolitan District: contact Steve Rippy. Mr. Rippy has assessed the cost of our water and sanitary sewer taps for the project. Mr. Rippey confirmed to me in an email that the BMMD has capacity to serve the Dollar General project: RE: BMMD - Tap Fee Calculations SR Steve Rippy <srippy@bmmetro.com> Reply| Yesterday, 4:14 PM 'Paul Johnson' (pj88@outlook.com) You replied on 5/15/2018 4:34 PM. Hi Paul, The Battlement Mesa Metropolitan District has adequate water and sewer service capacity to serve the Dollar General Store and will provide service to the property. Steve Rippy District Manager Battlement Mesa Metropolitan District srippy@bmmetro.com 970.285.9050 From: Paul Johnson [mailto:pj88@outlook.com] Sent: Tuesday, May 15, 2018 4:06 PM To: Steve Rippy Subject: Re: BMMD - Tap Fee Calculations Hi Steve, Garfield County Planning needs a will serve confirmation for the parcel we are putting the Dollar General store on, the parcel you quoted me on the costs of sewer and water taps. Would you please email me back with a confirmation that the Battlement Mesa Metropolitan District has capacity to offer and provide water and sewer taps for the following: Parcel #: 2407-181-02-002 Practical location: Adjacent to Stone Quarry Road, County Road 300, south of its intersection with West Battlement Parkway, County Road 300W, in the Battlement Mesa P.U.D, and also known as Lot 47 of the Valley View Village Subdivision. Thanks much! Paul Johnson PJ Consulting 2206 Crestline Ct., Grand Junction, CO 81507 970-210-5555 pj88@outlook.com From: Steve Rippy <srippy@bmmetro.com> Sent: Friday, September 1, 2017 10:57 AM To: pj88@outlook.com Subject: BMMD - Tap Fee Calculations Hi Paul, The Battlement Mesa Metropolitan District regulations identify an EQR of 0.35 per 1,000 square feet of commercial space for retail business. A building of 9,000 sq. ft. would equate to 9 x 0.35 or 3.15 EQR’s. The combined water and sewer tap fee is $9,000 per EQR, therefore the tap fee associated with the Dollar General Store would be $28,350. Feel free to contact me with any questions. Steve Rippy District Manager Battlement Mesa Metropolitan District srippy@bmmetro.com 970.285.9050 PJ Consulting Land Development Consulting 2206 Crestline Ct., Grand Junction, CO 81507 Paul Johnson: Office: 970-242-2947 Cell: 970-210-5555 Responses to the Minor Subdivision Review Criteria contained in Section 5-301 A. Overview. 1. A Minor Subdivision is any Subdivision that: a. Creates no more than 3 parcels. We have 2 parcels; b. Is served by a private well or wells, or a Water Supply Entity; We will be served by the Battlement Mesa Metropolitan District per Steve Rippy. Mr. Rippy has assessed the water and sewer tap fee amounts for our project. c. Does not require the extension, construction, or improvement of a County right-of-way. We are accessing the parcel via a simple entrance from Stone Quarry Road. 2. A parcel may be eligible to use the Minor Subdivision process once so long as it is not evading the Major Subdivision process or would result in a de facto Major Subdivision through the combination of previous contiguous Minor Subdivisions as determined by the Director. An appeal of this determination shall be processed as an Administrative Interpretation Appeal. Understood 3. Further divisions of the lots created through the Minor Subdivision process shall be processed as Major Subdivisions. Understood 4. Use of the Minor Subdivision process does not prevent the subsequent use of a RLDE pursuant to section 5-203. Understood B. Review Process. A Minor Subdivision application shall be reviewed pursuant to section 4-103, Administrative Review, and consistent with Table 5-103. Understood C. Review Criteria. In considering a Minor Subdivision application, the application shall demonstrate the following: 1. It complies with the requirements of the applicable zone district Zoning was established by Garfield County Resolution No. 2006-58, wherein it establishes “Uses by right: Retail establishments not exceeding 15,000 square feet of building area for each principal use”and this Code, including Standards in Article 7, Divisions 1, 2, 3 and 4. We are conforming, in our development, to the detailed standards set forth in Article 7, Divisions 1, 2, 3 and 4. The material herein and also provided by our engineer establishes our compliance. 2. It is in general conformance with the Comprehensive Plan. We are in conformance with the Comprehensive Plan 3. Shows satisfactory evidence of a legal, physical, adequate, and dependable water supply for each lot. Water and wastewater treatment are provided by the Battlement Mesa Metropolitan District: contact Steve Rippy. Mr. Rippy has assessed the water and sewer tap fee amounts for our project. 4. Satisfactory evidence of adequate and legal access has been provided. Please refer to our attached engineer’s plans. 5. Any necessary easements including, but not limited to, drainage, irrigation, utility, road, and water service have been obtained. Please refer to our attached engineer’s plans. 6. The proposed Subdivision has the ability to provide an adequate sewage disposal system. Water and wastewater treatment are provided by the Battlement Mesa Metropolitan District: contact Steve Rippy. Mr. Rippy has assessed the water and sewer tap fee amounts for our project. 7. Hazards identified on the property such as, but not limited to, fire, flood, steep slopes, rockfall and poor soils, shall be mitigated, to the extent practicable. Understood and will comply. 8. Information on the estimated probable construction costs and proposed method of financing for roads, water distribution systems, collection systems, storm drainage facilities and other such utilities have been provided. These will be provided with our application for a building permit. 9. All taxes applicable to the land have been paid, as certified by the County Treasurer’s Office. Certification attached. 10. All fees, including road impact and school land dedication fees, shall be paid. We will pay all of the applicable fees. 11. The Final Plat meets the requirements per section 5-402.F., Final Plat. The Final Plat will meet these requirements. 13461A552ADDRESS #13461A552ADDRESS #13461A552ADDRESS #13461A552ADDRESS #SCALE:1/8"=1'-0"FRONT ELEVATION1A021SIGN FURNISHED AND INSTALLED BY DOLLAR GENERAL CORP.WITH CIRCUIT AS NOTED ON ELECTRICAL PLAN. SIGN TO BECENTERED ON FRONT OF BUILDING. CONTRACTOR IS TOPROVIDE ADEQUATE BLOCKING AS REQUIRED BY SIGNMANUFACTURER TO SUPPORT SIGN WEIGHT OF UP TO 1,400LBS. EXTERIOR CANOPY SIGN SHALL BE SUPPORTED BY THEFACE OF THE CANOPY. COORDINATE THE PROPER SIGNAGETO BE USED WITH DOLLAR GENERAL.NOT USED.FLOOD LIGHT 16'-6" A.F.F. AT CENTERLINE OF CONNECTION TOWALL. REFER TO ELEC. DRAWINGS FOR ADDITIONAL INFO.FLOOD LIGHT 12'-0" A.F.F. TO TOP OF WALL PACK. REFER TOELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.WALL PACK AT 12'-0" A.F.F. REFER TO ELECTRICAL DRAWINGSFOR ADDITIONAL INFORMATION.NOT USED.TRIM - SEE EXTERIOR FINISH SCHEDULE FOR COLOR.GUTTER AND DOWNSPOUT - SEE EXTERIOR FINISH SCHEDULEFOR COLOR.STANDING SEAM METAL ROOF. GALVALUME FINISH.PRE-FINISHED METAL WALL PANELS, REVERSE RIB PROFILE.COLOR TO BE DARK BRONZE OR SIMILAR AS PROVIDED BYPRE-ENGINEERED METAL BUILDING MANUFACTURER. IFALTERNATE MATIERLA IS REQUIRED, PAINT OR MATCHSHERWIN WILLIAMS "VAN DYKE BROWN" WHERE ALLOWED BYAHJ.PRE-FINISHED METAL WALL PANELS. PROVIDE TAMPER-RESISTANT FASTENERS FOR BOTTOM 8'-0". COLOR TO BE"LIGHT STONE". IF ALTERNATE IS REQUIRED, COLOR TO BE SW7037 "BALANCED BEIGE".VENT FOR BATHROOM EXHAUST. REFER TO M01 FORADDITIONAL INFORMATION.DOOR BUZZER. REFER TO E01 FOR ADDITIONAL INFORMATION.NOT USED.HVAC UNITS MOUNTED ON ROOF. REFER TO MECHANICALSHEET M1 FOR MORE INFORMATION.MINIMUM EAVE HEIGHT IS 14'-0" A.F.F.OUTSIDE AIR TEMP. SENSOR MOUNTED OVER RECEIVINGDOORS @ 8'-0" A.F.F.ELEVATION KEYED NOTES2345678910111213141516171819IN NORTHERN CLIMATES, PROVIDE SNOW GUARDS ON ROOFPER LOCAL CODE.20FINISHED GRADE AT EXTERIOR WALLS SHALL BE A MINIMUM OF6" BELOW FINISHED FLOOR AT ALL NON PAVED AREAS.METAL CANOPY BY PRE-ENGINEERED METAL BUILDINGMANUFACTURER. (ONLY APPLICABLE TO C & D PROTOTYPES)218" SPLIT FACE CONCRETE MASONRY UNIT. PAINT TO MATCHSIDE WALL PANELS.1/2" DIAMETER x 6" LONG STAINLESS STEEL EYE BOLTS(CLOSED) WITH 1" DIAMETER OPENINGS. DRILL AND EPOXYINTO BLOCK WALL. 4 BOLTS TO BE LOCATED AS SHOWN EACHSIDE OF ENTRY, TOTAL OF 8 BOLTS.22SCALE:1/8"=1'-0"FRONT ELEVATION2A02DOLLAR GENERAL DORSEY DEVELOPMENT, INC.A2FOR APPROVALSCALE:1/8"=1'-0"FRONT ELEVATION3A02SCALE:1/8"=1'-0"FRONT ELEVATION4A02 LANDSCAPE LEGEND SHADE TREE EVERGREEN TREE DECIDUOUS SHRUBS EVERGREEN SHRUBS PERENNIALS/ORNAMENTAL GRASSES SHRUB BED WITH CONCRETE EDGER NATIVE SEED WITH CONCRETE EDGER BOULDERS 0 20 40 60 NORTH DECORATIVE BOULDER PLACEMENT NOT TO SCALE B L-1 FABRIC AROUND ROCK MULCH 3" TRENCH BACKFILL BURIED FABRIC EDGE TURF OR HARDSCAPE AMENDED TOPSOIL CENTER OF SHRUB BED FINISHED GRADE SHALL BE A MINIMUM OF 6" HIGHER THAN TOP OF CURB. MULCH CONTRACTOR TO PROVIDE 2" DEEP X 6" WIDE DEPRESSION TO KEY IN FABRIC & MULCH. CONCRETE EDGER, CURB OR SIDEWALK GRASS (IF APPLICABLE) AMENDED SOIL WEED CONTROL FABRIC AMENDED SOIL NOTES: EDGER OCCURS WHERE INDICATED ON PLAN. ALL CURVES TO BE SMOOTH IN TRANSITION, ALL CORNERS TO BE SQUARE. TOP OF EDGER TO BE SAME AS ADJACENT FINISHED GRADE. SHRUB BED DETAIL NOT TO SCALE C L-1 DECIDUOUS (OPPOSITE SIDE SAME)EVERGREEN (OPPOSITE SIDE SAME) 3. SPRAY DECIDUOUS TREE TRUNK WITH INSECTICIDE. WRAP WITH 4'' TREE WRAP FROM BOTTOM UP TO SECOND BRANCH. TAPE IN MIN. 3 PLACES. NOTES: 1. ALL BEDS SHALL BE PITCHED TO DRAIN AT 3% MIN. 2. ALL BEDS TO RECEIVE WEED CONTROL FABRIC ON FINISHED GRADE UNDER MULCH UNLESS OTHERWISE NOTED. NOT TO SCALE PLANTING DETAILA L-1 FASTEN 12 GA. WIRE THROUGH 1'' MIN. WIDTH NYLON STRAP AROUND TRUNK TO POST AND TWIST TO REMOVE SLACK BALL 2-4'' ABOVE FINISHED GRADE. LOCATE MAJOR ROOTS TO DETERMINE TOP OF ACTUAL ROOT BALL, TRUNK FLARE TO BE VISIBLE 6'' STEEL 'T' POST EACH SIDE @ 180 DEG., BLADE ON TREE SIDE SHRUBS, PERENNIALS: PLANTED AT OR 2'' ABOVE FINISHED GRADE BALL DIA. X 2 MULCH DEPTH AND TYPE AS NOTED ON PLANS EXCEPT OVER ROOT BALL. MULCH OVER ROOT BALL TO BE NO MORE THAN 1" THICK. HOLD ALL MULCH AWAY FROM TRUNK STEMS BY 1" BALL DIA. X 2 4. BACKFILL MIX: 1/3 SOIL AMENDMENT 2/3 SOIL FROM PIT INCORPORATE BIOSOL PLANTERS MIX, OR A MIX OF 50 LBS BIOSOL, 10 LBS HUMATE, 1 LB ALL PURPOSE MYCORRHIZAE AT THE FOLLOWING RATES: 1/2 CUP PER 1 GAL PERENNIAL 1 CUP PER 5 GAL SHRUB 2 CUPS PER 2'' CALIPER TREE MIX THOROUGHLY PRIOR TO BACKFILLING. CONTRACTOR TO PROVIDE AND INSTALL PLANT FERTILIZER TABLETS HAVING AN NPK ANALYSIS OF 20-10-5. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 30'' STAKE DRIVEN FLUSH. 12 GA. WIRE FROM STAKE TO 1'' MIN. NYLON STRAP AROUND TRUNK PREPARED BACKFILL, SEE NOTE #4 BURY 1/3 TO 2/3 OF BOULDER, BELOW NATURAL "SPRING LINE" OF ROCK 5 galJuniperus horizontalis 'Blue Chip'Blue Chip JuniperBCJ 2-3' 1-1.5'Juniperus horizontalis 'Andorra'5 gal Evergreen Shrubs Andorra JuniperANJ 5 gal Size 5 gal Prunus besseyi Scientific Name Chamaebatiaria millefolium Fallugia paradoxa Foresteria neo-mexicana FNB Fern Bush WSC APP NMP Apache Plume Western Sand Cherry New Mexico Privet 35-60'2 1/2" 25-40'Acer negundo 'Sensation'2 1/2" One Seed JuniperOSJ Juniperus monosperma 6'15-25' Pinon PinePPN Pinus cembroides edulis 6'10-20' BMS Blue Mist Spiraea Caryopteris incana 3-5'5 gal Rhus aromatica 'Gro-Low'5 galGro-low SumacGLS 5 gal 3-6' 4-7' 1.5-2.5' 1-2' 5 gal 5-7' Pawnee Buttes Sand CherryPBC Prunus besseyi 'Pawnee Buttes' 5 gal 0 0 0 0 0 0 0 0 0 0 0 Evergreen Trees Deciduous Shrubs Deciduous Trees SBE Sensation Box Elder0 Common Name Mature Height PLANT LIST 5 galPerovskia 'Little Spires'Little Spires Russian SageLRS0 2-3' 5 gal 3-5' 35-60'Zelkova serrata 'Green Vase'2 1/2"GVZ Green Vase Zelkova0 Celtis occidentalis HBY Hackberry0 Qty Code Schizachyrium scoparium 'Blaze'1 galBlaze Little Bluestem GrassBLB0 Ornamental Grasses BBG Blond Ambition Blue Grama Grass0 Bouteloua gracilis 'Blond Ambition'1 gal FRG Feather Reed Grass0 Calamagrostis x acutiflora 'Karl Foerster'1 gal 4-5' 3-4' 2-3' SEED AT 1 LB/1000 SF IN IRRIGATED AREAS SIDE OATS GRAMMA BOUTELOUA GRACILISBLUE GRAMMA SAND DROPSEED SPOROBOLUS CRYPTANDRUS 2% 3% 10% NATIVE SEED MIX 20% 20% HILARIA JAMESIIGALLETA GRASS HARD FESCUE FESTUCA OVINA 'DURAR' 30%WESTERN WHEATGRASS AGROPYRON SMITHII 'ARRIBA' SHEEP FESCUE FESTUCA OVINA 'COVAR'15% BOUTELOUA CURTIPENDULA COMMON NAME SCIENTIFIC NAME % OF MIX BY QTY PLANTING NOTES 1.CONTRACTOR SHALL VERIFY THE LOCATION AND ELEVATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. 2.ALL LANDSCAPING AND IRRIGATION TO CONFORM TO CURRENT ASSOCIATED LANDSCAPE CONTRACTORS OF COLORADO STANDARDS AND SPECIFICATIONS. 3.ALL SHRUB BEDS ARE TO RECEIVE SOIL AMENDMENT. SHRUB BEDS TO RECEIVE WEED FABRIC AND 3 INCH DEPTH OF MULCH. 4.SOIL AMENDMENT IS TO CONSIST OF 50% GROUND WELL-AGED MANURE, 50% FINELY GROUND AND AGED WOOD CHIPS. 5.WEED FABRIC IS TO BE 3.5 OZ. SPINBOND, PERMEABLE MATERIAL BY LANDMASTER, OR EQUAL. WEED FABRIC IS TO OVERLAP 6 INCHES AT SEAMS WITH NO GAPS AT EDGES. FABRIC IS TO BE PINNED IN PLACE WITH SOD STAPLE 5' ON CENTER AND IN ALL CORNERS. 6.SHRUBS AND TREES ARE TO SPACED AS SCALED FROM THE PLANTING PLAN. 7.MULCH FOR SHRUB BEDS SHALL BE 3/4'' TAN GRANITE. MULCH SHALL BE FREE OF TRASH, STICKS, ROOTS OR OTHER DEBRIS. NOTE: STATE LAW REQUIRES THESE PLANS TO BE PREPARED AND STAMPED BY A LICENSED LANDSCAPE ARCHITECT. SUBSEQUENTLY, ANY CHANGES OR MODIFICATIONS TO THESE PLANS, INCLUDING BUT NOT LIMITED TO LANDSCAPE MATERIAL SUBSTITUTIONS AND/OR RELOCATIONS, MUST BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO ,167$//$7,21)$,/85(72'262,6&216,'(5('$&5,0,1$/2))(16(3(5&56² DOLLAR GENERAL .#0&2.#00+0)#0& .#0&5%#2'#4%*+6'%674' 06*564''6 )4#0&,70%6+10%1 ÄÄ2 ÄÄ( YYYEKCXQPPGEQO SHEET NO. &4#90$; %*'%-'& ,1$01 &#6' 4'8+5+105 &1..#4)'0'4#.$#66.'/'06/'5#%1.14#&1BATTLEMENT MESA 24'.+/+0#4; .#0&5%#2'2.#0 %+#8100'41$'465 #551%+#6'5+0% %4 /*  ÄÄ .Ä #%%'26#0%'$.1%- &CVG S:\Projects\2018 job numbers\1805 Dollar General\1805 2-13-18.dwg, 2/20/2018 12:00:25 PM