Dora Garage
2079 County Road 112
Carbondale, CO 81623
General Notes:
Grid Line
The purpose of these drawings is to graphically depict the
The contractor shall verify all field dimensions and conditions,
and shall notify the architect of any variations from those items
general nature of the work to be performed. The contractor
dimensions and select fabrication processes and
shown herein.
shall confirm
techniques prior to construction. Conflicts or omissions shall
The shall be maintained in a clean, ordered condition,
be immediately brought to the attention of the architect for
jobsite
free of debris and litter. The jobsite shall not be unreasonably
clarification prior to the performance of work.
encumbered with any materials or equipment. Each
The General Contractor shall maintain a complete and current
subcontractor, immediately upon completing each phase of
all trash and debris as a result of their
set of project documents, drawings and specifications on the
their work, shall remove
operation.
job site at all times and shall include all approved shop
be
Direction of View
drawings and submittals. The General Contractor shall
drawings
The contractor shall do all cutting, fitting or patching of their
responsible for distribution of adequate copies of all
of
work that may be required to make its several parts fit together
and specifications to all applicable trades. Upon completion
digital and
properly. The contractor shall not endanger any other work by
the work, the design team shall submit a complete
hard set of drawings indicating any and all changes,
cutting, excavating, or otherwise altering the total work or any
repairing and replacing of
copy
omissions, or modifications. General Contractor to also
other part of it. All patching,
materials and surfaces cut or damaged in execution of work
perform and submit a copy of the LAN Test Report.
No substitutions, variations and deviations from these
shall be done with applicable materials so that the surfaces
replaced will, upon completion, match surrounding similar
documents shall be permitted without approval of the architect.
surfaces.
Application of any substitutions and/or variations shall be
The General Contractor shall verify ceiling height and
submitted to the architect for approval.
clearances above ceiling to the underside of structure above
All construction and materials shall be in accordance with all
for installation of duct work and diffusers, conduit, junction
boxes, fire sprinkler pipes and heads and light fixtures. All
applicable codes, ordinances, laws, permits and contract
work shall be coordinated by all trades to avoid interference
documents.
with methods of installatioP. Notify the architects if conflicts
The contractor shall be responsible for the accurate placement
exist.
of all new construction.
The contractor shall provide all necessary blocking, backing
and framing for bathroom accessories, handrails, guardrails,
All dimensions are to the face of stud, unless noted otherwise.
electrical fixtures, mechanical equipment, recessed items, and
Al materials stored on site shall be properly stacked and
any other items as required.
protected to prevent damage and deterioration. Failure to
Exterior building signage Shall be submitted under a separate
protect material may be cause for rejection of work.
permit application for review and approval as required by local
The contractor shall maintain, for the duration of work on this
authorities. Exterior signs are not within the scope of building
department a royal.
de P PP
project, all exits, exittegress lighting, fire protection devices and
alarms in conformance with all applicable codes and
The contractor shall be responsible for arranging all necessary
ordinances.
inspections required by Garfield County prior to covering any
The contractor shall review locations of light fixtures and other
such portions of work.
recessed ceiling and wall elements prior to framing for proper
placement of these items.
61
51
Symbols Legend:
To of Para
Grid Line
W 3.3b
Wall Type
105b
Door Tag
105c
Window Tag
Ceiling Hght.
Ceiling Tag
9'-0"� HL.01
Ceiling Type
Ceiling Height
Section/Detail Marker
---
Direction of View
01 �—Detail
Number
A4.1 �Sheet
Number
Interior Elevation Marker
2
Direction of View
31Detail
5:7 --
Number
2Sheet
Number
Elevation Height Marker
Target
Height Height
Kitchen Room Name
Room 100 Room Number
Referenced Detail
01 Detail Number
A4.1 Sheet Number
Project Team:
Contractor:
DM Neuman Construction Co.
310 19th Street
PO Box 2317
Glenwood Springs, CO 81602
(970) 945-7502
Contact: Jason Neuman
Qmn@dmneuman.com)
Architect:
DM Neuman Design Group Inc.
310 19th Street
PO Box 2317
Glenwood Springs, CO 81602
(970)945-7502
Contact: Rich Carter
(rich@dmneuman.com)
Structural Engineer:
Glenwood Structural and Civil, Inc.
812 Pitkin Avenue
Glenwood Springs, CO 81601
(970)928-0135
Contact: Adolfo Gona
(gsc@sopris.net)
Sheet Index:
A2.1 Plans and General Notes
AV Elevations & Truss Profiles
A4.1 Sections
S1.1 General Notes
S1,2 Framing Details
S2.1 Plans and Details
S22 Framing Details
Floor Plan
c&'AI 1:' _11A-= t'-0"
Site Plan _
Wall below
2
to 1–
Iflashing
--... - - --
\�h
— — - - k
Architectural
shingles
�77
r.�e
Metal roof 14:12 14:12
(shaded)S Sl
N 2
lope
4 F
12 � —
0
– m I
y �
C a.
3 - _ — _ — — - Ridge flashing & venting -
- �—
ao` o Architectural
(o shingles E
L -
- -- m Truss C
d
a
12 m Wall
flashing — — - -
o N Architectural
co
d — — rn shingles
Wall below a Architectural
-- shingles W
��
7�
Wall below
Roof Plan
SCALE: 1/4"
Refer to A3.1 for
Truss Profiles
0
n
m
02
2.1
03
A2.
rw ,., NAHB
D. M. NEU MAN
CONSTRUCTION CO
GLENWOOD SPRINGS, CO
RESIDENTIAL • COMMERCIAL • LOG HOMES
970945-7502
1 CONSULTANTS
Plan Notes:
1. Rooms shall have exterior glazing of no less than 8% of their floor
area to provide natural light in accordance with IRC Section
R303.1, or they shall be provided with artificial light per Exception
2 of IRC Section R303.1.
2. Rooms shall be provided with natural ventilation in accordance with
IRC Section R303.1, or they shall be provided with mechanical
ventilation in accordance with IRC Section R303.1 Exceptionl.
Roof Plan Notes:
1. Complying attic access shall be provided for buildings with
combustible ceilings or roof construction (Section R807.1 of
the IRC).
2. Asphalt shingles shall be installed in accordance with IRC
Section R905.2. Flashing for asphalt shingles shall comply
with IRC Section R905.2.8.
3. Provide ice and water shield in addition to 30# felt on eave sides
of ventilated roofs and valleys, 36" minimum band back from
heated area.
4. Provide price option for gutter and downspout assemblies.
Wall Finish Notes:
1. Wall and ceiling finishes shall have a flame -spread classification of
not greater than 200 and a smoke -development index of not
greater then 450 (Section R315).
2. Wood shakes, shingles and siding used as an exterior wall
covering shall be installed in accordance with Section R703.5.
3. Exterior walls shall be provided with flashing to prevent the entry of
water into the wall cavity (Section R703.8).
Dora Residence
Garage Addition
2079 CR 112,
Garfield County, CO
Permit Set
8-10-18
ff
DESCRIPTION Springridge Reserve Lot 73C
COPYRIGHT:
1 SHEET TITLE
A2.1