Loading...
HomeMy WebLinkAboutGeotechnical Investigation Letter 09.04.2018I{udelleston-Berry Engineerlng & Testing, LLC 640 White Avenue Grand Junction, Colorado 81501 Phone: 970-255-8005 Fax: 970-255-68 I 8 In fo@huddl estonberry. com Subject September 4,2018 Project#O1 509-0021 RC Schneider Construction 90 Caballo Carbondale, Colorado 81623 Attention: Mr. Bob Schneider Geotechnical Investigation 307 Pinyon Mesa Drive Glenwood Springs, Colorado Dear Mr. Schneider. This letter presents the results of a geotechnical investigation conducted by Huddleston-Berry Engineering & Testing, LLC (HBET) at 307 Pinyon Mesa Drive in Glenwood Springs, Colorado. The site location is shown on Figure 1. The proposed construction is anticipated to consist of a residential structure. The scope of our investigation included evaluating the subsurface conditions at the site to aid in developing foundation recommendations for the proposed construction. Site Conditions At the time of the investigation, the site was generally open and fairly flat. Vegetation consisted primarily of grasses and weeds. The site was bordered to the north by open land, to the east and west by vacant lots, and to the south by Pinyon Mesa Drive. Subsurface Investigation The subsurface investigation included one test pit on the lot. Test Pit TP-l was excavated to a depth of 9.0 feet below the existing ground surface. A typed test pit log is included in Appendix A. The test pit encountered 1.0 foot of topsoil above brown, moist, medium stiff to soft lean clay with sand soils to the bottom of the excavation. Groundwater was not encountered in the test pit at the time of the investigation. 307 Pinyon Mesa Drive #0 l 509-002 I 09t04n8 Hr¡ddleston-Bcrry tu¡hdht&tit6å LL{ Laboratory Testins Laboratory testing was conducted on samples of the native soils encountered in the test pit. The testing included grain-size analysis, Atterberg limits determination, and natural moisture content determination. The laboratory testing results are included in Appendix B. The laboratory testing results indicate that the native clays are moderately plastic. Based upon the laboratory testing results and upon our experience in the vicinity of the subject site, the native clay soils are anticipated to be slightly expansive. V/ater soluble sulfates were detected in the sites soils in a concentration of 0.23%. Foundation Recommendations Based upon the results of the subsurface investigation and nature of the proposed construction, shallow foundations are recommended. Spread footings and monolithic (turndown) structural slabs are both appropriate foundation alternatives. However, as discussed previously, the native clay soils are anticipated to be slightly expansive. Therefore, in order to limit the potential for excessive differential movements, it is recommended that spread footing foundations be constructed above a minimum of 24-inches of structural fill and that monolithic structural slab foundations be constructed above a minimum of 36-inches of structural fill. Due to the plasticity of the native clay soils, the native clay soils are not suitable for reuse as structural fill. Imported structural fill should consist of a granular, non-expansive, non-free drainins material such as crusher fines or CDOT Class 6 base course. Unless it can be demonstrated that the materials are not free-draining, pit-run materials should not be used as structural fill. For spread footing foundations, the footing areas may be trenched. However, for monolithic slab foundations, the structural fill should extend across the entire building pad area to uniform depth below the turndown edges. Structural fill should extend laterally beyond the edges of the foundation a distance equal to the thickness of structural fill. Prior to placement of structural fill, it is recommended that the bottom of the foundation excavation be scarified to a depth of 6 to 9 inches, moisture conditioned, and compacted to a minimum of 95% of the standard Proctor maximum dry density, within + 2Yo of the optimum moisture content as determined in accordance with ASTM D698. Structural fill should be moisture conditioned, placed in maximum 8-inch loose lifts, and compacted to a minimum of 95o/o of the standard Proctor maximum dry density for fine grained soils and modified Proctor maximum dry density for coarse grained soils, within*2o/o of the optimum moisture content as determined in accordance with ASTM D698 and Dl557, respectively. For structural fill consisting of imported granular materials and foundation building pad preparation as recommended, a maximum allowable bearing capacity of 1,500 psf may be used. In addition, a modulus of subgrade reaction of 250 pci may be used for structural fill consisting of crusher fines or base course. Foundations subject to frost should be at least 36-inches below the finished grade. 2 , l.l I X:\2008 ALL PROJECTS\01 509 - RC Schneider Construction\o1509-0021 307 Pinyon Mesauoo - Geo\01509-0021 LRo829l Ldoc 307 Pinyon Mesa Drive #01509-0021 09104/18 Æ\ @ Hudd¡cstoû-Bcrfygn¡lôñhat &!rln¡. llc Water Soluble Sulfates As discussed previously, water soluble sulfates were detected in the site soils in a concentration of 0.23%. This concentration of sulfates represents a severe degree of potential sulfate attack on concrete. The International Building Code (IBC) specifies Type V cement for this concentration of sulfates. However, Type V cement can be difficult to obtain in Western Colorado. Where Type V cement is unavailable, Type I-II sulfate resistant cement should be used. Lateral Earth Pressures Any stemwalls or retaining walls should be designed to resist lateral earth pressures. For backfill consisting of the native soils or imported granular, non-free drøínins, non-expansive material, we reconìmend that the walls be designed for an active equivalent fluid unit weight of 55 pcf in areas whers no surcharge loads are present. An at-rest equivalent fluid unit weight of 75 pcf is recommended for braced walls. Lateral earth pressures should be increased as necessary to reflect any surcharge loading behind the walls. Floorins Svstem and Exterior Flatwork Recommendations In general, slabs-on-grade cannot develop sufficient bearing pÍessures to resist swelling pressures. Therefore, some movement of slabs-on-srøde should be expected. As a result, framed floor are recoÍrmended for living areas. However, to reduce the risk of large scale movements of slabs-on-grade, such as the garage slab, it is recommended that non-structural floor slabs be constructed above a minimum of l8-inches of structural fill with subgrade preparation, structural fill materials, and fill placement be in accordance with the Foundation Recommendations section of this report. It is recommended that exterior flatwork be constructed above a minimum of l2-inches of structural fill. Slabs-on-grade should not be tied-into or otherwise connected to the foundations in any manner. In addition, where a floor slab is used, interior, non-bearing partition walls should include a framing void or slip joint which permits a minimum of 2-inches of vertical movement. Drainase Recommendations Proper grading and drainage is criticalto the long-term performance of the structure. Grading around the structure should be designed to carry precipitation and runoff away from the structure. It is recommended that the finished ground surface drop at least twelve inches within the frst ten feet away from the structure. It is also recommended that landscaping within five feet of the structure include primarily desert plants with low water requirements. In addition, it is recommended that irrigation, including drip lines, within ten feet of foundations be minimized. HBET recommends that downspout extensions be used which discharge a minimum of 10 feet from the structure. However, if subsurface downspout drains ate used, they should be carefully constructed of solid wall PVC pipe and daylight a minimum of 15 feet from the structure. In addition, an impermeable membrane is recommended below subsurface downspout drain lines. Dry wells should not be used. aJX:U008 ALL PROJECTS\01 509 - RC Schneider Construction\01509-0021 307 Pinyon MesaU00 - Geo\o1509-0021 LRo829l 8.doc 307 Pinyon Mesa Drive #0 I 509-002 I 09104/r8 As discussed previously, shallow groundwater was not encountered at the time of the investigation. However, a perimeter foundation drain is recommended to limit the potential for surface water to impact the structure. In general, the perimeter foundation drain should consist of prefabricated drain materials or perforatecl pipe ancl gravel with the flowline of the drain at the bottom of the foundation (at the highest point). The perimeter drain should slope at a minimum of 1.0% to daylight or to a sump with pump. An impermeable membrane should be placed at the base of the drain to limit the potential for moisture to infiltrate vertically down into the subsurface below the foundations. General Notes The recommendations included above are based upon the results of the subsurface investigation and on our local experience. These conclusions and recommendations are valid only for the proposed construction. As discussed previously, only one test pit was conducted at the site. Therefore, the precise natnre ancl extent of any subsurface variability may not become evident until constnrction. The recommendations contained herein are designed to reduce the risk and magnitude of movements and it is extremely critical thaf ALL of the recommendations herein be applied to the design and construction. However, HBET cannot predict long-term changes in subsurface moisture conditions andlor the precise magnitude or extent of any volume change in the subsurface materials. Where sìgníficant increases in subsurface moisture occur due to poor gradíng, ìmproper stormwater mdnagement, utilitv líne føilure, excess irrìgation, or anv other cause, during or øfter constructíon. signilicant movements are øossíble. In addition, the success of the structure foundations, slabs, etc. is critically dependent upon proper construction. Therefore, HBET should be retained to provide materials testing, special inspections, and engineering oversight during ALL phases of the construction to ensure conformance with the recommendations herein. In addition, the homeo\¡r'ners should be provided a copy of this report and made fully aware of the risks associated with living in an area of moisture sensitive soils. We are pleased to be of service to your project. Please contact us if you have any questions or comments regarding the contents of this report. Respectfully Submitted: Huddleston-Berry Engineering and Testing, LLC Michael A. Berry, P.E. Vice President of Engineering lluddlcator¡-Bcrfy &lùGh¡.tt{lú& *C 4 3 010q/04/a X:U008 ALL PROJECTS\01 509 - RC Schneider Construction\o1509-0021 307 Pinyon Mesa\200 - Geo\o1 509-0021 LRo829l 8.doc FIGURES @ Garfield Gounty Land Explorer GurJield County Garfield Gounty, Golorado tta53t4f t{x}it ESSGlttfût 5 I -JF "ç$l 2395{)t ¡l[tl \ \\ ] .9 I l3c3{¡t¡:ilt{x}r{. .1.393û&tqrs55, FIGURE 1 Site Location Map 2s$3û8til¡{Xt{tc 1 inch = 1,505 feet 1 inch = 0.28 miles 0 0.2 _+=. 0.8 M¡'es0.4 Garf ield County Colorado www,8ârf ield-county.comGarficld County Color¿do Garfield County Land Explorer Printed by Web User D¡s.laimer Thls ls ã compilatbn of records as lhey app€ar in the carlield county ol¡ce5 aled¡n8 the âreâ shown, Ihl5 drawlng ls to be u5êd only for relerencê puÌpose5 and th€ &unty k nol .€sponr¡ble lor any ¡na!€uraci€5 hercin contained. O Copyright Garfield County, Colorado I All Rights Reserved Pdnledt 8/2g/20!8 at 10:40:18 AM F¡GURE 2Site Plan APPENDIX A Typed Test Pit Log GEOTECH BH COLUMNS 01509-0021 307 PINYONUS LAB.GDT 8/29l,I8!vo(-mc){zc=I!mvoOlo(oooNc)trmz{Ðo(hc)Jq.ooofØcc)ı'=\o\o^âÌr{{!1'.ÀllooÞ oxuuå<Fuh=5ì;r r ! ='êôæ5 ô oqeSg.tiæqO < w5.doo Ë.?AJY *t4:Jæ =tÞu-*oÈÉìíE'0cR"jo'øf.5sqt.l<ô!voemo-{t-oc)Þ-{ızG)ofÉooo.Øı=.=ioIoo!7oLmc)-{z=m(¡)o\JÌt=ooø0)o{mU,{!{zcEErn7{!I.¡Itomo.Tlzo{mtnrooomI@CNgmxc}ÞIız3mIog-.1!)C)x:rTDÂ)c)x5o(Dmxc)Þ{ızcloz{,tC¡ovaı':'IÞ+mCN{n-{mg@_.1@oLmoxmtrtI!TDc)o=!t-m{mo@-.¡@ItftFmxc)Þ{ızImzc,o'Ïrmxc)ÞIızo-eovo>=rEl<=FIll IqFËËÈf?{ızo-.?ovoczommız{mvt-{!{LNmIoDEPTH(ft)GRAPHICLOG+mnrom(to7It-.{ozSAMPLE TYPENUMBERRECOVERY %(ROD)BLOWCOUNTS(N VALUE)POCKET PEN.(tsf)DRY UNIT WT(pcr)MOISTURECoNTENT (%)-lr{=msio{(!CDMvoFINES CONTENT(%)LIQUIDLIMITPLASTICLIMITPLASTICITYINDEXsto'.[¡ Þ; [:- l.-. t\ . -t.-t-oo)for=.5U)0)fo.!)o"o(oÀ)f.c)U'-{o-ItØIf-rÀ)úoÂ)øø=oo-ou,f-oÀ)C)t-É.U)0)o.c)r-vqoá?39.Ø!+3os3ú,âoØo+:o(s-o(IlO)(,N)(oCD@(,TDoo3ooØ=ß)(ob(Dor+ APPENDIX B Laboratory Testing Results N l-ô di 5 (n Fzo ñ NoIoo UJ N a/)z t Huddleston-Berry Engineering & Testing, LLC 640 Write Avenue, Unit B Grand Junction, CO 81501 970-255-8005 970-2ss-6818 GRAIN SIZE DISTRIBUTION CLIENT RC Schneider Construction PROJECT NAME 307 Pinvon Mesa Dr PROJECT NUMBER 01509-OO2I PROJECT LOCATION Glenwood Sr:rinqs. tü U.S. SIEVE OPENING IN INUHES I u.s. sth.vh. NUMljblìs HYDROMËTER 30 40 5060 100140200 t-T(, uJ =o É. IJJz LL Fz UJo É. IJJÈ 100 95 90 B5 BO 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 1 GRAIN SIZE IN MILLIMETERS 0.1 0.001 ¡ I t'TT ï \ lr I COBBLES GRAVEL SAND SILT OR CLAYcoarsefinecoarsemediumfine Specimen ldentification Classification LL PL PI Cc Cu O TP-1, GB1 gt201g LEAN CLAYwith SAND(CL)32 19 13 Specimen ldentification D100 D60 D30 D10 %Gravel %Sand %sitt o/oClay o TP-1, GBI 8t2018 2 0.0 17.2 82.8 Huddleston-Berry Engineering & Testing, LLC 640 White Avenue, Unit B Grand Junction, CO 81501 970-255-8005 970-2ss-68t8 ATTERBERG LIMITS' RESULTS CLIENT RC Schneider Construction PROJECT NAME 307 Pinvon Mesa Dr PROJECT NUMBER 01509-0021 PROJECT LOCATION Glenwood Sorinos. CO @ P L S T I c I T I N D E X 50 40 30 20 10 O CL-ML @ @ 0 0 20 40 60 LIQUID LIMIT 00 Specimen ldentification LL PL PI #200 Classification o TP-1, GB1 812018 32 19 13 83 LEAN CLAYwith SAND(GL) oN Fz Ào<aU z z I ts Nao dtoþ o U)F = ÉU(0LU t- N F."oq @f Ø l-z o a(, Ø IU z z ts Nooooo zo F G o Huddleston-Berry Engineering & Testing, LLC 640 White Avenue, Unit B Grand Junction, CO 81501 970-255-8005 970-255-6818 CLIENT RC Schneider Construction PROJECT NAME MOISTU RE-DENSITY RELATIONSHIP PROJECT NUMBER 01509-0021 PROJECT LOCATION Glenwood Sprinqs, CO 307 Pinvon Mesa Dr ,Ul \ \ I \ \ \ \ \ \ \ \ \ \ \ \ /\.\ \ \ /\\ t \ I Samplc Datc: Sample No.: Source of Material: Description of Material 8t17t2018 18-0627 145 TP.1 LEAN CLAYwith SAND(CL) Test Method:ASTM D698A 140 135 TEST RESULTS Maximum Dry Density 110.0 PCF Optimum Water Content 16.0 % 130 125 GRADATTON RESULTS (% PASS¡NG) #200 #4 3t4" 80 100 100 o tl-6z UJo É.Õ ATTERBERG LIMITS 1 20 LL PL PI 32 t9 13 115 110 105 100 95 90 Curves of 100% Saturation for Specific Gravity Equalto: 2.80 2.70 2.60 0 5 15 WATER CONTENT, % 10 20 25 30