Loading...
HomeMy WebLinkAboutPlan DesignProfile: CL-DRIVE, Sta:0+00 to Sta:3+50 Scale: Vert.=30', Horiz.=30' 6760 6770 6780 6790 6800 6810 6820 6830 6770 6780 6790 6800 6810 6820 6830 Pr:6767.41Ex:6767.40+00 Pr:6767.94Ex:6768.4Pr:6772.30Ex:6771.81+00 Pr:6777.88Ex:6777.2Pr:6782.00Ex:6782.22+00 Pr:6785.90Ex:6786.0Pr:6790.40Ex:6789.53+00 Pr:6795.651.03% 11.40% 7.80% 10.50%PVIS: 0+00.00PVIE: 6767.41LVC: 31.11' PVI STA: 0+62.86 PVI ELEV: 6768.06 K: 3.00 LPE: 6767.90 LPS: 0+47.30 BVCS:0+47.30BVCE:6767.90EVCS:0+78.41EVCE:6769.83LVC: 27.00' PVI STA: 2+77.83 PVI ELEV: 6788.07 K: 10.00 LPE: 6787.02 LPS: 2+64.33 BVCS:2+64.33BVCE:6787.02EVCS:2+91.33EVCE:6789.49LVC: 36.00' PVI STA: 1+52.90 PVI ELEV: 6778.33 K: 10.00 HPE: 6779.73 HPS: 1+70.90 BVCS:1+34.90BVCE:6776.27EVCS:1+70.90EVCE:6779.73EX. GRADE PR. GRADE EDGE OF EX. PAVEMENT Profile: CL-DRIVE, Sta:3+50 to Sta:7+55 Scale: Vert.=30', Horiz.=30' 6800 6810 6820 6830 6840 6850 6860 6790 6800 6810 6820 6830 6840 6850 6860 Ex:6795.7Pr:6800.33Ex:6799.34+00 Pr:6804.20Ex:6803.5Pr:6809.65Ex:6809.35+00 Pr:6815.57Ex:6815.2Pr:6821.49Ex:6821.96+00 Pr:6826.79Ex:6827.9Pr:6828.41Ex:6832.97+00 Pr:6829.41Ex:6835.9Pr:6829.50Ex:6836.27+55 7.60% 11.84% 2.00%PVIS: 7+54.54PVIE: 6829.50LVC: 42.37' PVI STA: 4+59.30 PVI ELEV: 6804.84 K: 10.00 LPE: 6803.23 LPS: 4+38.11 BVCS:4+38.11BVCE:6803.23EVCS:4+80.48EVCE:6807.34LVC: 29.00' PVI STA: 3+80.38 PVI ELEV: 6798.84 K: 10.00 HPE: 6799.94 HPS: 3+94.88 BVCS:3+65.88BVCE:6797.32EVCS:3+94.88EVCE:6799.94LVC: 50.00' PVI STA: 6+50.00 PVI ELEV: 6827.41 K: 5.08 HPE: 6827.91 HPS: 6+75.00 BVCS:6+25.00BVCE:6824.45EVCS:6+75.00EVCE:6827.91EX. GRADE PR. GRADE >>>>>>>>>>>>>>>>>>W SO W SO >>>>WMEMPoint Table Point # 500 501 502 503 504 505 506 507 508 509 510 511 512 513 Raw Description CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE Elevation 6767.72' 6768.09' 6769.95' 6772.78' 6775.65' 6778.29' 6780.40' 6782.35' 6784.32' 6786.27' 6788.36' 6790.89' 6793.56' 6796.21' Northing 31246.09 31263.64 31285.32 31307.71 31327.18 31341.54 31350.13 31352.58 31348.74 31338.75 31323.17 31309.94 31305.75 31311.24 Easting 23120.07 23102.33 23089.87 23078.91 23063.23 23042.76 23019.29 22994.41 22969.70 22946.79 22927.23 22906.02 22881.37 22856.98 Point Table Point # 514 515 516 517 518 519 520 521 522 523 524 525 526 Raw Description CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE CL-DRIVE Elevation 6798.68' 6800.76' 6802.66' 6804.82' 6807.49' 6810.55' 6813.65' 6816.73' 6819.78' 6822.13' 6825.25' 6826.87' 6828.11' Northing 31325.58 31346.75 31370.10 31391.15 31408.40 31420.90 31427.92 31429.66 31430.47 31431.25 31430.85 31424.89 31413.53 Easting 22836.51 22823.20 22814.28 22800.79 22782.70 22761.04 22737.05 22712.08 22687.22 22662.71 22635.82 22610.90 22588.13 6770683568156810WSWSET0 + 0 0 SCF SCF SCF SCF #500 6768 > >>>> EX. TRANSFORMER EX. WATER SHUT OFF. THE SIZE OF THE SERVICE MAY BE TOO SMALL TO PROVIDE ADEQUATE PRESSURE AT THE HOME SITE. CONTRACTOR TO COORDINATE WITH THE DISTRICT AND UPSIZE THE WATER SERVICE AS NECESSARY. INSTALL TEMP EROSION CONTROL FENCE ALONG LOWER LIMITS OF DISTURBANCE CONSTRUCT A 12" DEEP SWALE TO DIRECT RUNOFF AROUND HOUSE INSTALL WATER METER INSTALL ELECTRIC METER 10' x 30' EMERGENCY PULLOUT UNDISTURBED VEGETATION Meadow PointPROPERTY LIN E PROPERTY LINE68306825AA11BBCCDDEEFFGGHHIIJJ2233445566778899AA11DWrefrigd/wdblovenwarming drawerrange, exhaust hoodmwprepsinkLndrySinksinkisland top4-2 x 6-0UTILITYSINKBBCCDDEEFFGGHHIIJJ2233445566778899XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX>>>>>>>>>>>>>>>>>>>>>>>>>> > >>>>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>677567806785679067956800680568106815682068156810680568006795679067856780677567706820DSDSDSDSDS DSDS4'' Ø 6'' Ø 6''Ø6''Ø6'' Ø 6'' Ø4''ØWSWSWSWSWSWSWS WS WS WS WS WS WS WS WS WS WS WS WS W S W S WS WSWSWSWSWSWS W S WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS W S W S WS WSWSWSWSWSETETETET ET ET ET ET ET ET ET E T ETETETET ET ET ETET ET ET ET ET E T ETETET68404'' Ø 4'' Ø 4'' Ø 1+002+00 3+004+005+ 0 0 6+00 7+00 4'' Ø 4'' Ø 4'' Ø SCFSCF SCF SCF SCF SCF SCF SCF SC F S C F S C F SC F SCFS C F SCF SCF SCF SCFSCFSCF SCF SCF SCF SCF SCFSCFSCFSCF#526 #525 #507#505 #502 #512 #509 #501 #503 #514 #5 1 0 #511#516 #506#504#515#520#518#521#519 #517#522#523#524#508#513DS4'' Ø 6770 6768678067856795676967756 7 9 06800SLSLSLSLSLC/OC/O >> >>>> >>>> INSTALL EROSION LOGS EVERY 40LF IN ROADSIDE DITCH, TYP.SOUTH ROADSIDE DITCH SHALL HAVE 3:1 SIDE SLOPES AND 12" BOTTOM WIDTH, SEE SECTION NORTH ROADSIDE DITCH SHALL HAVE 3:1 SIDE SLOPES AND 12" BOTTOM WIDTH, SEE SECTION PROTECT EX. WELL EX. SWALE EX. DITCH EX. SWALE YPC#19598 EL:6767.32' BENCHMARK EX STORM PIPE PROTECT EX. WELL INSTALL TEMP EROSION CONTROL FENCE ALONG LOWER LIMITS OF DISTURBANCE INSTALL INLET PROTECTION CONSTRUCT A 12" DEEP SWALE TO DIRECT RUNOFF AROUND HOUSE CONSTRUCT A 12" DEEP SWALE TO DIRECT RUNOFF AROUND HOUSE AND BOULDER WALLS EXTEND ELECTRIC AND TELECOMMUNICATIONS FROM EX. PEDESTALS AT THE SOUTHEAST CORNER OF THE PROPERTY EXTEND WATER SERVICE USING 1"Ø AWWA COPPER OR PURECORE (SIZING BY OTHERS) MAINTAIN A MINIMUM SEPARATION OF 4-FEET BETWEEN WATER AND ELECTRIC/TELEPHONE UTILITIES. EDGE OF EXISTING ASPHALT DISTURBANCES LIMITS, TYP. INSTALL TEMP EROSION LOGS IN SWALE EVERY 40 LF TIERED BOULDER RETAINING WALL (SEE DETAIL) SEE SHEET C.2 FOR ENLARGED VIEW INSTALL TEMP EROSION CONTROL FENCE ALONG LOWER LIMITS OF DISTURBANCE ROADSIDE DITCH GRADES OUT TO FLOW INTO THE UNDISTURBED VEGETATION ROADSIDE DITCH RESTARTS ROADSIDE DITCH GRADES OUT TO FLOW INTO THE UNDISTURBED VEGETATION ROADSIDE DITCH RESTARTS 4:1 4: 1 PROPERTY LINE Residence T.O. Ply: 6830.00' (100'-0")PROPERTY L INE 4:1 10:11 0 : 1 10:14:110:110:11 0 : 1>>>>>>> >> >GGGG 4''Ø4''Ø 4. 0 % 4%DSDS4:1 68056810681568206825 68 2 968366840 683 268356837 682568206815682868436840683568306825Vicinity Map 1"=4000'NORTH00 30'60' Scale: 1" = 30' DS 7965 LEGEND 7965 >>>> SL SL SL G WS WS WS 4''Ø 4''Ø ET G ET SL SL SL WS WS W SO WM GRADE AROUND THE PERIMETER OF BUILDING AS NECESSARY AT 2.5% FOR 10-FEET MINIMUM IN PAVED AREAS AND 10% FOR 10-FEET MINIMUM IN UNPAVED AREA TO ENSURE PROPER DRAINAGE AWAY FROM THE FOUNDATION. EXISTING/PROPOSED GRAVEL ROADWAY PROPOSED DISTURBANCE/REVEGETATION EXISTING CONTOUR PROPOSED CONTOUR PROPERTY LINE EASEMENT EXISTING/PROPOSED WATER SERVICE/SHUTOFF/METER EXISTING/PROPOSED SEWER SERVICE/CLEANOUT EXISTING/PROPOSED ELECTRIC/TELEPHONE EXISTING/PROPOSED GAS PROPOSED FOUNDATION DRAIN SYSTEM (BY OTHERS) HEAT TAPE PROPOSED 4"Ø PVC STORM PIPE (WATERTIGHT) PROPOSED 4"Ø PERF. UNDERDRAIN PIPE PROPOSED FLOWLINE GENERAL DIRECTION OF FLOW PROPOSED DOWNSPOUT/RAIN CHAIN & SPLASH PAN 1 T EXISTING/PROPOSED UTILITY PEDESTALS & METERSTGMEM SITE To Basalt Hwy. 82 Carbondale C/O EE 6" MIN. 6" CLASS 6 AGGREGATE BASE COURSE. CONTRACTOR TO PLACE 4" LIFT AT THE BEGINNING OF CONSTRUCTION AND THEN REGRADE AND PLACE ANOTHER 2" JUST PRIOR TO PROJECT CLOSEOUT. LINE THE DITCH WITH 6"Ø NOMINAL ANGULAR RIPRAP EMBEDDED IN 6" OF HEAVY CLAY. COBBLES ARE NOT ACCEPTABLE. 16' MIN. Scale: N.T.S. Driveway with Stabilized Roadside Ditch(es) SCARIFY THE SUBGRADE AND RECOMPACT TO 95% STANDARD PROCTOR 37110DERIC J O N WA L T ERCOLOR A D O LICE N S EDPROF E SSIONA L E N GINEER3/9/18 6" CLASS 2 AGGREGATE BASE COURSE PER PLAN TBD Meadow Point Lot 2 - Callicotte Ranch County of Garfield, State of Colorado Parcel No: 2393-133-06-002 NORTH ByRevisionNo.Date923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. FILE NAME: Designer: Drafter: Date:N:\PROJECTS\2017\17032-Lot 2 Callicotte Ranch\dwg\17032-C-Topo.dwg 3/9/2018 2:22 PM9.8.7.6.5.4.3.2. 03/09/18 Add tiered boulder wall and adjust grading around bldg. djw11/08/17 APL DJW 17032-c-topo.dwg 17032 970.404.0302 GLENWOOD SPRINGS, CO 81601 144 CLIFF ROSE WAY URIEL MELLIN GARFIELD COUNTY, COLORADO1. 11/10/17 Revise design for house relocations/rotation, add OWTS djw----Driveway, Overall Grading, Drainage And Erosion Control PlanLot 2: Callicotte RanchC.1 1.5'1.5'MATCH ABOVEMATCH BELOWII IO INVERT IN INVERT OUT 6" MIN. PER PLAN1.5'1.5' 3:1 M A X. 3:1 M A X . 3:1 M A X . 3:1 MAX. 3:1 M A X . 3:1 M A X. NOTES: 1.SURVEY INFORMATION PROVIDED BY HIGH COUNTRY ENGINEERING. 2.SITE HAND AND GUARD RAILING BY OTHERS. 3.SEE ARCHITECTURAL, LANDSCAPING AND AND STRUCTURAL ENGINEERING PLANS FOR ADDITIONAL BUILDING AND LANDSCAPE INFORMATION. 4.SEE ADDITIONAL NOTES ON REMAINING PLAN SHEETS. 5.ALL DEMOLITION AND CONSTRUCTION SHALL MEET OR EXCEED THE CURRENT CONSTRUCTION AND DESIGN STANDARDS ESTABLISHED BY THE COUNTY AND BE SUBJECT TO OBSERVATION BY THE COUNTY AND THE PROJECT ENGINEER. 6.EXISTING UTILITIES ARE SHOWN AS THEY ARE BELIEVED TO EXIST, BUT MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. PRIOR TO ANY EXCAVATION, CONTRACTOR SHALL CONTACT ALL APPROPRIATE UTILITY COMPANIES FOR LINE LOCATIONS. CONTRACTOR SHALL NOTIFY PROJECT ENGINEER OF ANY POTENTIAL CONFLICTS PRIOR TO UTILITY CONSTRUCTION SO THAT LINE OR GRADE CHANGES CAN BE MADE TO AVOID A CONFLICT OF AN EXISTING UTILITY. THE CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES FROM DAMAGE DURING CONSTRUCTION. THE CONTRACTOR, AT NO EXPENSE TO THE OWNER OR PROJECT ENGINEER, SHALL REPAIR ANY DAMAGED UTILITIES. 7.ALL EXCAVATIONS FOR UTILITY LINES, RETAINING WALLS, ROADWAYS, BUILDING STRUCTURES, DRAINAGE FACILITIES AND TRENCHES, ALONG WITH WORK IN GENERAL, SHALL MEET THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), COLORADO INDUSTRIAL COMMISSION, OR THE COLORADO DIVISION OF MINES, WHICH EVER APPLIES. SAFETY IS THE CONTRACTOR'S RESPONSIBILITY. NO OTHER PARTIES ARE RESPONSIBLE FOR SAFETY IN, ON OR ABOUT THE SITE, NOR FOR COMPLIANCE BY THE APPROPRIATE PARTY WITH ANY REGULATIONS RELATING HERETO. 8.COMPACTION MUST BE ATTAINED AND COMPACTION RESULTS SUBMITTED TO THE OWNER AND THE PROJECT ENGINEER PRIOR TO ACCEPTANCE. COMPACTION SHALL MEET OR EXCEED COUNTY REGULATIONS. THE MINIMUM COMPACTION STANDARD SHALL BE 95% STANDARD PROCTOR UNLESS OTHERWISE SPECIFIED BY THE GEOTECHNICAL ENGINEER. 9.THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION ACTIVITIES TO THE AREA WITHIN THE STREET RIGHT OF WAY AND PROPERTY OWNED, OR EASEMENTS PROVIDED TO OWNER. THE CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR CONSENT OF THE PROPERTY OWNER INVOLVED. ANY DAMAGE TO PRIVATE PROPERTY BY THE CONTRACTOR OUTSIDE THESE LIMITS WITHOUT THE PERMISSION OF THE PRIVATE PROPERTY OWNER WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 10.THE CONTRACTOR SHALL ENSURE DRAINAGE AWAY FROM ALL STRUCTURES IN ALL DIRECTIONS. 11.THE CONTRACTOR SHALL AT ALL TIMES KEEP TWO FULL SETS OF CONTRACT DRAWINGS MARKED UP TO INDICATE THE AS-BUILT CONDITIONS. THE DRAWINGS SHALL BE PROVIDED TO THE OWNER AND THE ENGINEER UPON COMPLETION OF THE WORK. WHERE PRACTICAL, THE CONTRACTOR IS TO PROVIDE AT LEAST TWO TIES FROM PHYSICAL MONUMENTS TO ALL FITTINGS, VALVES, MANHOLES, AND THE END OF ALL SERVICE LINES. 12.ON-SITE OBSERVATIONS AND REVIEW CONDUCTED BY THE COUNTY OR THE PROJECT ENGINEER OF CONSTRUCTION WORK IN PROGRESS ARE NOT TO BE CONSTRUED AS A GUARANTEE OR WARRANTY BY THE COUNTY OR THE PROJECT ENGINEER OF THE COMPLETED WORK AND THE CONTRACTOR'S RESPONSIBILITIES. 13.THE CONTRACTOR SHALL TAKE ALL APPROPRIATE PRECAUTIONS TO SIGNIFICANTLY REDUCE ANY POTENTIAL POLLUTION CAUSED BY HIS ACTIVITIES, INCLUDING VEHICLE FUELING, STORAGE OF FERTILIZERS OR CHEMICALS, ETC. THE CONTRACTOR SHALL HAVE IDENTIFIED PROCEDURES FOR HANDLING POTENTIAL POLLUTANTS AND IDENTIFIED SPILL PREVENTION AND RESPONSE PROCEDURES PRIOR TO ANY ACTIVITIES AT THE PROJECT SITE. 14.THE CONTRACTOR SHALL NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES. ANY MISSING DIMENSIONS OR DISCREPANCIES IN PLANS, FIELD STAKING, OR PHYSICAL FEATURES SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ENGINEER. IF THE CONTRACTOR PROCEEDS WITH THE WORK WITHOUT NOTIFYING THE ENGINEER, HE DOES SO AT HIS OWN RISK. 15.DISPOSAL OF TRASH, ASPHALT, CONCRETE AND CONSTRUCTION DEBRIS IS THE CONTRACTORS RESPONSIBILITY AND SHALL BE CONSIDERED PART OF THE WORK. 16.ALL PRODUCT INFORMATION SHOWN IS AS PROVIDED BY THE MANUFACTURER. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND COMPLYING WITH THE MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS FOR THE INSTALLATION OF ALL MATERIALS WITH SPECIAL ATTENTION TO PROPER SEALING OF MATING SURFACES. THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE ENGINEER IF ANY DISCREPANCIES ARE FOUND BETWEEN THE DELIVERED PRODUCTS AND THOSE SHOWN ON THIS PLAN. 17.FOUNDATION AND WELL DESIGNS TO BE OBTAINED FROM THE PROJECT STRUCTURAL ENGINEER. 18.THE FOUNDATION DRAIN SYSTEM SHALL BE INSTALLED PER THE RECOMMENDATION OF THE STRUCTURAL AND GEOTECHNICAL ENGINEERS. 19.ANY STORM DRAIN PIPES SHALL BE INSTALLED WITH 1% MINIMUM SLOPE TO THE OUTFALL POINTS. HEAT TAPE SHALL BE INSTALLED IN ALL EXTERIOR ROOF GUTTERS, DRAIN PIPES, AREA DRAINS, TRENCH DRAINS AND GRATED STRUCTURES. 20.ACCUMULATED SNOWFALL SHALL BE REMOVED TO GRASS AREA TO ENSURE THAT PROPER DRAINAGE AWAY FROM THE BUILDING IS MAINTAINED. 21.ALL PIPES SHALL BE INSTALLED WITH WATERTIGHT CONNECTIONS. 22.ALL ROOFS TO BE GUTTERED 6''Ø 6''Ø PROPOSED 6"Ø PVC STORM PIPE (WATERTIGHT) Scale: N.T.S. Tiered Boulder Landscape Wall DRIVEWAY 5' MIN. @ 10:1, TYP. 12" MIN. BURY6" 1 MIN 4"Ø PERFORATED PVC DRAIN PIPE SLOPED AT 0.5% MIN. ALONG THE INTERIOR BASE OF EACH WALL. CORRUGATED PIPE IS NOT ACCEPTABLE. OUTSIDE EACH WALL, EXTEND TO DAYLIGHT AT 2% MIN. WITH A SOLID SCH.40 PVC PIPE. DRAIN PIPE SYSTEM MUST HAVE 4" MIN. GRAVEL BEDDING ON ALL SIDES. (TYP.EACH TIER) 1-1/2" SCREENED ROCK BACKFILL (TYP.) (TYP.EACH TIER) COMPACT BACKFILL UNDER BOULDERS TO 95% STANDARD PROCTOR DENSITY, WITH A MOISTURE CONTENT NEAR OPTIMUM, TYP. (TYP.EACH TIER)SINGLE WALL: 6'-0" MAX.TIERED WALL: 4'-0" MAX.4' MAX.BASE ROW: 30"Ø MIN. ANGULAR BOULDERS TOP ROW: 18"Ø MIN. ANGULAR BOULDERS 1' MIN. (TYP.) MIDDLE ROW: 24"Ø MIN. ANGULAR BOULDERS BASE ROW: 24"Ø MIN. ANGULAR BOULDERS TOP ROW: 18"Ø MIN. ANGULAR BOULDERS 12" MIN. OF COMPACTED HEAVY CLAY, TYP. 12" MIN. BURY BOULDER LANDSCAPE WALL NOTES: 1.THIS DETAIL IS TO BE USED ONLY FOR RETAINING LANDSCAPED AREAS WITH A MAXIMUM WALL HEIGHT OF 6-FEET FOR SINGLE WALLS AND AND A HEIGHT OF 4-FEET PER TIER FOR TIERED WALL. THIS DETAIL SHALL NOT BE USED TO RETAIN STRUCTURES/VEHICLE LOADED AREAS OR AREAS REQUIRING GREATER RETENTION. 2.TIERED WALLS TALLER THAN 4-FEET OR SUPPORTING MORE THAN TWO (2) ADDITIONAL TIERS SHALL BE CONSTRUCTED AS STRUCTURALLY SUPPORTED SOIL NAIL WALLS WITH A FACADE OF STACKED BOULDERS. THE SOIL NAIL SYSTEMS SHALL BE AS DESIGNED BY OTHERS. 3.FREE DRAINING WALL BACKFILL SHOULD BE CAPPED WITH AT LEAST 12 INCHES OF COMPACTED HEAVY CLAYS TO REDUCE SURFACE WATER INFILTRATION. 4.BOULDERS SHALL BE ANGULAR AND SQAURE/RECTANGULAR IN SHAPE. ROUND RIVER BOULDERS ARE NOT ACCEPTABLE. 5.INSTALL MIRAFI 140N FILTER FABRIC BETWEEN THE NATIVE EXCAVATION AND THE SCREENED ROCK BACKFILL. 6.SET BASE ROWS ON BENCHES WHERE THE TOPSOIL HAS BEEN REMOVED AND THE SUBBASE HAS BEEN SCARIFIED TO 9" MINIMUM DEPTH & RECOMPACTED TO 95% STANDARD PROCTOR. 7.CARE SHOULD BE TAKEN NOT TO OVER COMPACT THE BACKFILL OR USE LARGE EQUIPMENT NEAR THE WALL. 8.SELECT AND PLACE BOULDERS IN A MANNER WHICH PERMITS AT LEAST 30% CONTACT AREA WITH ADJACENT BOULDERS. 9.PLACE LARGER BOULDERS AT BOTTOM AND TRANSITION TO SMALLER BOULDERS AT TOP OF WALL. UNDER NO CIRCUMSTANCES SHOULD ANY BOULDER BE PLACED ON TOP OF ANOTHER BOULDER WHICH IS SMALLER THAN ITSELF. MIDDLE ROW: 24"Ø MIN. ANGULAR BOULDERS 0.5 1 MIN 0.5 2% MIN. FITTER FABRIC (TYP.EACH TIER) 5' MIN. FROM BACK OF WALL SWALE AROUND THE WALL AA11BBCCDDEEFFGGHHIIJJ2233445566778899AA11DWrefrigd/wdblovenwarming drawerrange, exhaust hoodmwprepsinkLndrySinksinkisland top4-2 x 6-0UTILITYSINKBBCCDDEEFFGGHHIIJJ2233445566778899XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX68106815682068356815681068106820DSDSDSDSDSDSDS4'' Ø 4'' Ø 4''Ø6''Ø6'' Ø 6'' Ø 6'' Ø 6''Ø6''Ø6'' Ø 6''Ø6''Ø6''Ø6''Ø6'' Ø 6'' Ø 6'' Ø 6'' Ø 6'' Ø 6'' Ø4''Ø4''Ø4''Ø4''ØWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS W S W S W S W S W S W S ETETETET ETETETETETET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET 68404'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 5+ 0 0 6+00 7+00 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4 % R10' SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SC F SC F SC F SC F SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCF SCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFDS4''Ø4'' Ø 4'' Ø #717 6837.51' #718 6837.00' #719 6837.00' #720 6837.00' #721 6836.92' #722 6836.64' #723 6834.70' #724 6833.39' #725 6832.00' #730 6837.00' #734 6831.77' #735 6831.50' #736 6830.65' #737 6829.87' #771 6827.22' #773 6826.92' #772 6827.22' SL SL SLSLSLSLSLSL SL SL SL SL SL SL SL SL SL SL SL SLSLC/OSLSLC/O 1 1 1 1 1 1 1 1 1 0.5%0.5%0.5%0.5%0.5%0.5%0.5%0.5%0. 5 % 0. 5 % 0. 5 % 0. 5 % 0. 5 % 0. 5 % 0. 5 % 0. 5 % 0. 5 % 0. 5 % 0. 5 %0.5%0.5%0.5%0.5%0. 5 % 0. 5 % 0. 5 % CONSTRUCT A 12" DEEP SWALE TO DIRECT RUNOFF AROUND HOUSE DISTURBANCES LIMITS, TYP. SWALE HIGH POINT BEGIN ROADSIDE DITCH SLOPE THE FOUNDATION DRAIN AT 0.5% MIN. TO DAYLIGHT UTILITY BOXES AND METERS TIE THE FLOOR DRAINS TO THE DOWNSPOUT DRAIN LINE. SEE ARCHITECTURAL PLANS FOR RIM ELEVATIONS, TYP. INSTALL ROOF DOWNSPOUT, TYP., DISCHARGE ONTO DRIVEWAY TIE IN DOWNSPOUTS TO DRAIN EXTEND THE DOWNSPOUT DRAIN TO DAYLIGHT WITH SOLID 6"Ø PVC. SLOPE THE FOUNDATION DRAIN AT 0.5% MIN. TO DAYLIGHT DIRECT SWALE AROUND THE TOP OF THE TIERED LANDSCAPE WALL EXTEND THE DOWNSPOUT DRAIN TO ROADSIDE DITCH WITH SOLID 4"Ø PVC. INSTALL TEMP EROSION LOGS IN SWALE EVERY 40 LF 4:1 CATCH SLOPE EXTEND THE FOUNDATION DRAIN TO DAYLIGHT WITH SOLID 4"Ø SDR35 PVC. INSTALL HEAT TAPE AROUND ALL DOWNSPOUT DRAINS INSTALL ROOF DOWNSPOUT & SPLASH PAN, TYP. DISCHARGE ONTO SURFACE EXTEND THE DOWNSPOUT DRAIN TO DAYLIGHT WITH SOLID 4"Ø PVC. 0. 5 %0.5%>> > > > > >>>>>>>>> > > > > > >>>>>>>>>>>>>>>> 4:1 4: 1 4:1 10:11 0 : 1 10:14:110:110:11 0 : 1 1.0%CATCH SLOPE @ 4:1, TYP. #731 6836.56' #732 6833.36' #733 6832.59'>>>>>>>>>>>>>>>>>>> > > > >>>>> > > >4''Ø5' MIN. TIERED BOULDER LANDSCAPE WALL (SEE DETAIL)GGG GGGGGGG G GDRAIN GARAGE FLOOR AT 2% TO THE DRIVEWAY OR EXTEND FLOOR DRAINS TO DAYLIGHT Residence T.O. Ply: 6830.00' (100'-0") PROPERTY LINE BUILDING ENVELOPE BUILDING ENVELOPEF G : 6 8 3 4 . 0 ' F G : 6 8 3 8 . 0 ' F G : 6 8 2 9 . 4 8 ' F G : 6 8 2 9 . 4 8 'FG:6830.1'FG:6829.7'FG:6827.5'FG:6826.0'FG:6829.92'FG:6828.3'FG:6829.92'FG:6829.67'FG:6829.17'FG:6829.3'FG:6829.3'F G : 6 8 2 8 . 9 2 ' F G : 6 8 2 8 . 9 2 ' F G : 6 8 3 3 . 0 ' F G : 6 8 2 8 . 3 ' F G : 6 8 2 7 . 0 'FG:6828.3'FG:6827.0'F G : 6 8 2 8 . 3 ' BURIED PROPANE #738 6827.00' #739 6823.00'FG:6838.0'FG:6838.0'#700 6823.13' #701 6826.39' #702 6827.98' #703 6828.64' #704 6828.55' #705 6828.95' #706 6828.54' #707 6828.73' #708 6829.36' #709 6829.48' #710 6829.09' #711 6828.81' #712 6828.36' #713 6827.96' #714 6826.00' #715 6824.00' #716 6821.46' #726 6828.02' #727 6833.00' #728 6832.50' #729 6832.05' #740 6836.90' #741 6836.16' #742 6835.16' #743 6834.98' #744 6834.49' #745 6834.40' #746 6832.00' #770 6828.26'4''Ø4''Ø4''Ø4''Ø4''Ø 4''Ø 4''Ø 4''ØR10' #760 6829.78' #761 6829.63' #762 6829.56' F G : 6 8 2 9 . 9 1 ' F G : 6 8 2 9 . 9 1 '1.0%1.6%1. 0 % #763 6829.82' 4. 0 % 4% #764 6828.42' #765 6828.42' Point Table Point # 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 Raw Description Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Edge Pvmt Top Wall Top Wall Top Wall Top Wall Top Wall Top Wall Top Wall Top Wall Top Wall Top Wall Top Wall Elevation 6823.13' 6826.39' 6827.98' 6828.64' 6828.55' 6828.95' 6828.54' 6828.73' 6829.36' 6829.48' 6829.09' 6828.81' 6828.36' 6827.96' 6826.00' 6824.00' 6821.46' 6837.51' 6837.00' 6837.00' 6837.00' 6836.92' 6836.64' 6834.70' 6833.39' 6832.00' 6828.02' 6833.00' Northing 31439.59 31435.81 31422.57 31426.09 31435.44 31425.33 31407.84 31396.35 31372.23 31344.63 31359.57 31370.29 31387.55 31393.29 31407.67 31419.34 31423.13 31365.46 31377.74 31402.06 31403.30 31420.91 31432.75 31442.19 31443.50 31439.11 31434.35 31294.35 Easting 22653.14 22619.09 22587.50 22573.73 22568.25 22550.99 22561.25 22560.28 22540.04 22563.60 22576.13 22585.13 22599.61 22607.57 22628.91 22645.93 22666.73 22534.36 22533.47 22553.47 22553.50 22543.45 22546.65 22564.29 22576.03 22586.00 22601.99 22560.90 Point Table Point # 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 760 761 762 763 764 765 770 771 772 Raw Description Top Wall Top Wall Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale Swale FG FG FG FG FG FG FG FG FG Elevation 6832.50' 6832.05' 6837.00' 6836.56' 6833.36' 6832.59' 6831.77' 6831.50' 6830.65' 6829.87' 6827.00' 6823.00' 6836.90' 6836.16' 6835.16' 6834.98' 6834.49' 6834.40' 6832.00' 6829.78' 6829.63' 6829.56' 6829.82' 6828.42' 6828.42' 6828.26' 6827.22' 6827.22' Northing 31282.61 31262.26 31341.83 31334.17 31314.36 31306.94 31282.30 31274.89 31256.75 31254.45 31257.96 31261.55 31346.49 31379.67 31428.83 31436.08 31447.58 31448.74 31449.93 31285.85 31275.81 31271.45 31296.05 31294.26 31321.96 31266.46 31270.30 31298.85 Easting 22551.04 22575.29 22509.75 22513.32 22536.93 22540.50 22541.11 22544.68 22566.30 22573.53 22617.08 22661.59 22510.90 22527.78 22535.59 22540.77 22562.33 22566.52 22589.58 22555.73 22567.70 22572.90 22569.05 22627.78 22651.03 22583.97 22642.31 22670.79 1 1 DSDS4:1 68 2 9 6 8 2 8 68276826682568206815682868276825682068166815681768186819682168226823682468 3 2 6 8 3 2 68316830682968286 8 3 3683468356836683768426841684068396838683768376836 68356836683768386839 68406833683368 2 7 68 2 6 68 2 5 68 2 4 68 2 3 68 2 2 6 8 2 1 6 8 2 0 6819681868176815681468166813681268116843684068356830682568306825NORTH ByRevisionNo.Date923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. FILE NAME: Designer: Drafter: Date:N:\PROJECTS\2017\17032-Lot 2 Callicotte Ranch\dwg\17032-C-Topo.dwg 3/9/2018 2:22 PM9.8.7.6.5.4.3.2. 03/09/18 Add tiered boulder wall and adjust grading around bldg. djw11/08/17 APL DJW 17032-c-topo.dwg 17032 970.404.0302 GLENWOOD SPRINGS, CO 81601 144 CLIFF ROSE WAY URIEL MELLIN GARFIELD COUNTY, COLORADO1. 11/10/17 Revise design for house relocations/rotation, add OWTS djw----Enlarged Grading & Drainage Plan With Underground PipingLot 2: Callicotte RanchC.2 00 10'20' Scale: 1" = 10' 37110DERIC J O N WA L T ERCOLOR A D O LICE N S EDPROF E SSIONA L E N GINEER3/9/18 DSDSDSDS>>>>>>> > > > >>>>>DSDS>>>>XXXXXXXXXXXXXXXXXXXXXXXXXXX>>>>>>>>>>>>>>>>>>> >>NORTH ByRevisionNo.Date923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. FILE NAME: Designer: Drafter: Date:N:\PROJECTS\2017\17032-Lot 2 Callicotte Ranch\dwg\17032-C-Topo.dwg 3/9/2018 2:22 PM9.8.7.6.5.4.3.2. 03/09/18 Add tiered boulder wall and adjust grading around bldg. djw11/08/17 APL DJW 17032-c-topo.dwg 17032 970.404.0302 GLENWOOD SPRINGS, CO 81601 144 CLIFF ROSE WAY URIEL MELLIN GARFIELD COUNTY, COLORADO1. 11/10/17 Revise design for house relocations/rotation, add OWTS djw----Fire Truck Vehicle Path Model & Misc. Civil DetailsLot 2: Callicotte RanchC.3 00 10'20' Scale: 1" = 10'FLOWFLOWPOINTS A MUST BE HIGHER THAN POINT B D D POINT A ENTRENCH 3" POINT A POINT B POINT A EROSION LOG POINT B FLOW POINT A PLAN VIEW PLAN VIEW A A EROSION LOG SEDIMENT REMOVAL SHALL BE PERFORMED CONTINUOUSLY FOR PROPER FUNCTION.Ø ENTRENCH 3" ØFL O W TO E A C H O T H E R AP P R O X . 9 0 ° lc3dtr016 SECTION A-A AREA DRAIN SECTION D-D EROSION LOG Scale: N.T.S. Temporary Erosion Control Logs 10' MAX.24" MIN. 42" MIN. 18" MIN. 24" MIN.FLOW FLO W ANCHORED IN TRENCH AND FIRMLY ATTACHED SILT FENCE FABRIC TO POSTPOST (2" X 2" NOMINAL) 6" x 6" TRENCH SILT FENCE FABRIC ANCHORED IN 6"x6" TRENCH AND ATTACHED FIRMLY TO POST SILT FABRIC STAPLED TO POSTS COMPACTED BACKFILL Scale: N.T.S. Temporary Sediment Control Fence FEATURE THAT NEEDS PROTECTION USE 2 PINE STAKES 1 1/2" x 1 1/2" x 12" AT ALL EROSION LOG ENDS OR JOINTS, OTHERWISE USE A STAKE EVERY 24 IN. AND CONTINUE TO ALTERNATE ORIENTATION THROUGHOUT THE LENGTH OF THE EROSION LOG. BELOW GRADE WALL SLOPE PER GEOTECH REPORT BACKFILL SLOPE PER OSHA PREFABRICATED DRAINAGE COMPOSITE (MIRADRAIN 6000 OR EQUIVALENT ATTACH PLASTIC SHEETING AT FOUNDATION WALL SLIP JOINT SLAB-ON-GRADE FOOTING OR PAD COVER ENTIRE WIDTH OF GRAVEL WITH NON-WOVEN GEOTEXTILE FABRIC (MIRAFI 140N OR EQUIVALENT).2" MIN.4"Ø PERFORATED RIGID PIPE (SDR35 PVC). THE PIPE SHOULD BE PLACED IN A TRENCH WITH A SLOPE OF 1% MIN. (1/8 INCH DROP PER FOOT) TO DRAIN. ENCASE PIPE IN 1/2" TO 1-1/2" WASHED GRAVEL. EXTEND GRAVEL LATERALLY TO FOOTING AND AT LEAST 1/2 HEIGHT OF FOOTING. FILL ENTIRE TRENCH WITH GRAVEL. NOTES: 1.THE BOTTOM OF THE DRAIN SHOULD BE AT LEAST 2 INCHES BELOW BOTTOM OF FOOTING AT THE HIGHEST POINT AND SLOPE DOWNWARD TO A POSITIVE GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPING. 2.CONTRACTOR TO FOLLOW ANY ADDITIONAL RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER 8" MIN. OR BEYOND 1:1 SLOPE FROM BOTTOM OF FOOTING, (WHICHEVER IS GREATER) SLOPE TO DRAIN 6" MINIMUM (Verify with the Geotechnical Engineer) Scale: N.T.S. Typ. Foundation Drain 00 150'300' Scale: 1" = 150'12"36" MIN.,48" MAX.6" MIN. 2"Ø SCH.80 PVC TELEPHONE CONDUIT 4"Ø SCH.80 PVC ELECTRIC CONDUIT6" CLASS 6 ABC 30" MIN. 6" WIDE MARKER TAPE TRACER WIRE 24" MIN.12" MIN.Scale: N.T.S. Electric & Telephone Trench12"30" MIN.,36" TYP.6" MIN. GAS SERVICE LINE 6" MIN. 6" WIDE MARKER TAPE TRACER WIRE Scale: N.T.S. Gas/Propane Trench NOTES: 1.GAS SHALL BE INSTALLED WITH AT LEAST 4' OF SEPARATION BETWEEN OTHER UTILITIES. 2.BACKFILL THE TRENCH WITH 4" MINUS ONSITE SELECT MATERIAL COMPACTED TO 95% STANDARD PROCTOR. SAND NOTES: 1.ELECTRIC & TELEPHONE SHALL BE INSTALLED WITH AT LEAST 4' OF SEPARATION BETWEEN OTHER UTILITIES. 2.BACKFILL THE TRENCH WITH 4" MINUS ONSITE SELECT MATERIAL COMPACTED TO 95% STANDARD PROCTOR.12"6'-6"MIN,8' MAX.12" MIN. WATER SERVICE (MATCH EX. SIZE AND TYPE) 4" MIN. 6" WIDE MARKER TAPE TRACER WIRE Scale: N.T.S. Water Service Trench NOTES: 1.WATER SHALL BE INSTALLED WITH AT LEAST 10' OF SEPARATION BETWEEN SEWER AND 4' OF SEPARATION BETWEEN OTHER UTILITIES. 2.BACKFILL THE TRENCH WITH 4" MINUS ONSITE SELECT MATERIAL COMPACTED TO 95% STANDARD PROCTOR. CLASS 6 ABC FOR COPPER, CRUSHER FINES FOR HDPE Scale: 1"=150' Drainage Basins 37110DERIC J O N WA L T ERCOLOR A D O LICE N S EDPROF E SSIONA L E N GINEER3/9/18 X 1 12" MIN.ADJACENT GRADE 4" COMPACTED ON-SITE SILT OR CLAY MATERIAL LINE ALL SWALES WITH FLOWLINE GRADES EXCEEDING 6% WITH NORTH AMERICAN GREEN SC150 EROSION FABRIC. NOTE SEE THE GRADING, DRAINAGE AND EROSION CONTROL SHEET FOR SWALE LOCATIONS SIDE SLOPES ADJACENT TO BUILDINGS SHALL BE 10:1 MIN. FOR 10-FEET. OTHERWISE, SIDE SLOPES SHALL BE 3:1 MIN. :35.7°Steering Angle 3.33'20.83' 8.50' 8.17' 6.0 Carbondale: Station #85 feet : : : Width Track Lock to Lock Time 34.58' Scale: 1"=10' Fire Truck Turning Movement MEADOW LAKEBasin-A1 Scale: N.T.S. Drainage Swale Scale: N.T.S. Typical Site Drain and Roof Drain Basin-A2 BUILDING30" MIN.TEE REDUCER 90° BEND HEAT TAPE INSTALLED PER NOTES 4"Ø RISER DOWNSPOUT FITTING OR IF DOWNSPOUT IS TOO LARGE, USE A 12" SQUARE NYLOPLAST INLINE DRAIN GRATE W/ A HOLE CUT IN GRATE TO MATCH THE DOWNSPOUT AND SLEEVE THE DOWNSPOUT/CHAIN AT LEAST 6" INTO THE PIPE. 4"Ø OR 6"Ø STORM SEWER (PER PLAN) NOTES: 1.ALL DOWNSPOUTS AND DECK DRAINS SHALL BE ADS N-12-WT CPP (WATERTIGHT), SCH.40 PVC OR SDR35 PVC. FLEXIBLE CORRUGATED PLASTIC IS NOT ACCEPTABLE. 2.ADDITIONAL FITTINGS AND BENDS MAY BE REQUIRED TO DEFLECT OVER OR AROUND LANDSCAPE WALLS. 3.HEAT TAPE SHALL BE INSTALLED IN ALL DOWNSPOUTS/STORM SEWER PIPES AND CONNECTED TO THE BOTTOM OF ALL INLET GRATES.RAIN CHAINOR DOWNSPOUT12"Ø NYLOPLAST AREA DRAIN WITH DOME GRATE, PVC RISER BEND, TYP. INSTALL HEAT TAPE THROUGH THE PIPE AND CONNECT TO THE BOTTOM OF THE GRATE,TYP. INSTALL TEMPORARY FILTER FABRIC OR SEDIMENT BASKET UNDER THE GRATE. DEFGHIJ23456789refrigd/wdblovenwarming drawerrange, exhaust hoodmwprepsinksinkisland top4-2 x 6-0DEFGHIJ23456789680568106815DSDSDS6''Ø6''Ø6'' Ø 6'' Ø 4''Ø4''Ø4''Ø4''ØWSWSWSWSWSWS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS W S W S W S W S W S WS WS WS WS WSWSWSWSWSWSWSWSWSWSWSWSWSWSET ET ET ET ET E T E T E T E T ET ETETET4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø 4'' Ø SC F SC F S C F S C F S C F S C F S C F SCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSCFSL SL 5' MIN.25' MIN.42 (3x14) ADS ARC36 (STANDARD) UNITS6' MIN. 4 Bedroom Residence SLSLSLSLSLSL SL SL SL SL SL SL SL SL SL SL SL SLSLC/OSLSLC/O >>>>>>>>>>>>>>>681068054''Ø4''Ø 4''Ø 4''Ø 4''Ø DSDSCDPHE APPROVED 1,500-GALLON PRECAST CONCRETE TWO CHAMBER SEPTIC TANK (SEE DETAIL) INSPECTION PORT, TYP. CLEANOUT AT THE BUILDING POTABLE WATER SERVICE ENSURE FOUNDATION DRAIN PIPE DOES NOT DISCHARGE ABOVE THE ABSORPTION FIELD 4"Ø SCH.40 PVC INSTALL CLEANOUT AT BEND FITTINGS, TYP. DO NOT INSTALL THE ABSORPTION FIELD INSIDE THE FILL LIMITS CONSTRUCT A 6" DEEP CUTOFF SWALE ABOVE THE ABSORPTION FIELD NORTH ByRevisionNo.Date923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. FILE NAME: Designer: Drafter: Date:N:\PROJECTS\2017\17032-Lot 2 Callicotte Ranch\dwg\17032-C-Topo.dwg 3/9/2018 2:22 PM9.8.7.6.5.4.3.2. 03/09/18 Add tiered boulder wall and adjust grading around bldg. djw11/08/17 APL DJW 17032-c-topo.dwg 17032 970.404.0302 GLENWOOD SPRINGS, CO 81601 144 CLIFF ROSE WAY URIEL MELLIN GARFIELD COUNTY, COLORADO1. 11/10/17 Revise design for house relocations/rotation, add OWTS djw----Onsite Wastewater Treatment System (OWTS)Lot 2: Callicotte RanchC.4 37110DERIC J O N WA L T ERCOLOR A D O LICE N S EDPROF E SSIONA L E N GINEER3/9/18 00 10'20' Scale: 1" = 10' SYSTEM NOTES 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH GARFIELD COUNTY REGULATION NO.43 ONSITE WASTEWATER TREATMENT SYSTEMS (OWTS), MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE ENGINEER MUST OBSERVE THE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE A LETTER OF INSPECTION AS REQUIRED BY THE LOCAL AGENCY. A REQUEST FOR INSPECTION MUST BE MADE BY THE CONTRACTOR AT LEAST 48-HOURS PRIOR TO THE EXPECTED TIME OF BACKFILLING. 2.DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A.FOUR (4) BEDROOM RESIDENCE USING DOSING AND TREATMENT LEVEL 1 (TL1). 2.B.AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD5): 2.B.1.SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOD5 lbs/day 2.B.2.ADWF = 75 gpd * (3 BEDROOMS * 2 PERSONS/BEDROOM + 1 BEDROOM * 1 PERSON) = 525 gpd 2.B.3.BOD5 = 0.20 lbs/day * (3 BEDROOMS * 2 PERSONS/BEDROOM + 1 BEDROOM ROOM * 1 PERSON) = 1.40 lbs/day BOD5 mg/L = BOD5*1,000,000 = 1.40 lbs/day*1,000,000 = 319.8 mg/L ADWF*8.34 525 gpd*8.34 2.B.4.CBOD5 = BOD5 * 0.85 = 272 mg/L 3.SEPTIC TANK (SEC.43.9.B.2.a): 3.A.SEPTIC TANK: 4 BEDROOMS = 1,250 GALLONS (TABLE 9-1) 3.B.INSTALL A 1,500-GALLON TWO-COMPARTMENT TANK. 3.C.THE TANK IS NOT SUBJECT TO BUOYANCY. 4.ABSORPTION AREA CALCULATIONS 4.A.GROUNDWATER WAS NOT ENCOUNTERED, THE PROPERTY CONTAINS SLOPES LESS THAN 20%. THE SOILS CONTAIN AND LARGE QUANTITY OF BOULDERS AT DEPTH BETWEEN 3.5'-7.5' BELOW THE SURFACE. THEREFORE, THE SYSTEM SHALL BE A GRAVITY FED SHALLOW GRAVELLESS CHAMBER SYSTEM IN A SEQUENCED TRENCH CONFIGURATION. 4.B.SOILS WERE ANALYZED BY HP KUMAR GEOTECHNICAL ENGINEERING (SEPTEMBER, 2017; PROJECT NO.17-7-695) TO BE CLAY (CL) SILTY, SANDY, STIFF, SLIGHTLY MOIST BROWN POROUS MATRIX (TYPE-2) OVER BASALT ROCKS IN A SANDY CLAYEY SILT MATRIX WITH A TREATMENT LEVEL 1 LONG TERM ACCEPTANCE RATE (LTAR) OF 0.60 gpd/SF. 4.C.MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 525 = 875 S.F. LTAR 0.60 gpd/S.F. 4.D.SIZE ADJUSTMENT FACTORS: GRAVITY TRENCH = 1.0; CHAMBER TRENCH= 0.7 4.D.1.A, adj = 875 SF * 1.0 * 0.7 = 613 SF 4.E.GRAVELLESS CHAMBER SYSTEM: 4.E.1.INFILTRATOR QUICK4: 613 SF / 12 SF/UNIT = 52 UNITS. USE 54 UNITS IN 3x18 SERIAL TRENCH CONFIGURATION. 4.E.2.ADS ARC36 (STANDARD): 613 SF / 15 SF/UNIT = 41 UNITS. USE 42 UNITS IN A 3x14 SERIAL TRENCH CONFIGURATION. 5.THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITES OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 6.CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8.INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9.INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 5-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10.SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. GENERAL ABSORPTION AREA NOTES 1.INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2.ABSORPTION TRENCHES SHALL BE 3' WIDE OR LESS AND PARALLEL THE GROUND SURFACE CONTOURS. PARALLELING TRENCHES SHALL BE SEPARATED BY A DISTANCE OF 6' MIN. 3.THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4.DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5.NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6.UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE OVER-EXCAVATION. 7.TOPSOIL COVER MAY BE VARIED (12-INCH MINIMUM, 18-INCHES MAXIMUM) TO ALLOW FOR LANDSCAPING. SITE EVALUATION 1.SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DERIC J. WALTER, PE DAN HARDIN,, PE BOUNDARIES UNLIMITED INC.HP KUMAR GEOTECHNICAL ENG. 923 COOPER AVE., STE. 201 5020 C.R.#154 GLENWOOD SPRINGS, CO 81601 GLENWOOD SPRINGS, CO 81601 970.945.5252 970.945.7988 2.EVALUATION DATE(S): SEPTEMBER 2017. 3.SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=525 GPD: 3.A.SPRING OR WELL=100' 3.B.POTABLE WATER SUPPLY LINE=25' 3.C.POTABLE WATER SUPPLY CISTERN=25' 3.D.DWELLING=20' 3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 3.G.LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H.DRY GULCH, CUT BANK OR FILL AREA=25' 3.I.SEPTIC TANK=5' 3.J.RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3.SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A.SPRING OR WELL=50' 3.B.POTABLE WATER SUPPLY LINE=10' 3.C.POTABLE WATER SUPPLY CISTERN=25' 3.D.DWELLING=5' 3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G.LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H.DRY GULCH, CUT BANK OR FILL AREA=10' 3.I.STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. FLOW FINISH GRADE 4"Ø PVC RISER 4"Ø 45° BEND 4" PVC WYE 4"Ø SEWER LINE SURFACE 6"-8" CLAY (CL): SILTY, SANDY, STIFF, SLIGHTLY MOIST BROWN POROUS MATRIX (TYPE-2) Vicinity Map 1"=4000' Scale: N.T.S. Typical Chamber Serial Trench System Scale: N.T.S. Site & Soils Evaluation SOIL EVALUATION 1.SOIL PERCOLATION TESTS IN THE NATIVE SOILS (CLAY (CL) SILTY, SANDY, STIFF, SLIGHTLY MOIST BROWN POROUS MATRIX) RANGED FROM 24-24 MPI INDICATING A SOIL TYPE OF 2 AND AN LTAR OF 0.60 GPD/SF. 2.THE NATIVE SOILS CONTAIN BOULDERS. WHEN ENCOUNTERED, REMOVED THE BOULDER AND BACKFILL THE VOID WITH IMPORTED LOAMY SAND OR SANDY GRAVELS. Scale: N.T.S. Cleanout Scale: N.T.S. Septic Tank & Dosing System TOPSOIL 3'-7'±NORTHSITE To Basalt Hwy. 82 Carbondale 36" MAX. SERIAL TRENCH SYSTEM 12" MIN. COVER 18" MAX. COVER UNDISTURBED NATIVE SOILS 6' (MIN.) 6"TOPSOIL (MIN.) FINISH GRADE 4" PVC RISER WITHEFFLUENT FILTERNOTE: STATE APPROVED 1500-GALLON TW0 (2) CHAMBER CONCRETE SEPTIC TANK.4" PVC RISERIN INFLOW SHALL ENTER THE LARGER CHAMBER BAFFLE OPENING18"18"~3" CONCRETE LIDCONCRETE LID PRECAST RISER 1" CRUSHED ROCK, 6" DEEP TO LEVEL TANK BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.05'±. (TYP.) IF NECESSARY TO ACHIEVE THIS SURFACE, IMPORT CONCRETE SAND TO USE AS LEVELING MATERIAL. REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. FINISHED GROUND - MAINTAIN POSITIVE SLOPE AWAY FROM TOP SURFACE OF THE CHAMBER TRENCHES. PVC COUPLING FOR SUPPORT STANDARD INSPECTION PORT, TYP. (4"Ø PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL A MARKER IF CAP IS TO BE BURIED. INFLOW AND OVERFLOW PIPES SHALL ENTER THE UPPER KNOCKOUTS 4"Ø SCH. 40 OR SDR35 PVC OVERFLOW PIPE GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS ARC36 (STANDARD), OR ENGINEER APPROVED EQUAL. MAINTENANCE NOTES 1.TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: 1.A.MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B.MINIMIZE SOLIDS GOING DOWN THE DRAIN. 1.C.ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D.MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E.USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F.KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G.AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H.DO NOT USE LYE-BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN-OFF, OR OTHER STRONG CLEANING AGENTS. 1.I.DO NOT PUT ANY “ROOT DETERRENTS” DOWN THE DRAIN. 1.J.DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN 1.K.MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2.THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. BASALT ROCKS IN A SANDY CLAYEY SILT MATRIX