Loading...
HomeMy WebLinkAboutEnvelope Compliance Certificate 06.04.2018Generated by COMcheck-Web Software Envelope Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Title: Project Type: New Construction Construction Site: Building Location (for weather data): Climate Zone: Building Use: A0ivity1yp .(s) Owner/Agent: Designer/Contractor: Rifle, Colorado 5b Floor Area Section 2: Envelope Assemblies and Requirements Checklist E. vnE. elo.e TBD: No.envelopee__assemblies specified Envelope Assemblies: Component Name/Description Simple saver Roof: Metal Building, Standing Seam, Ext. Wall: Metal Building Wall, Double Layer Mineral Fiber, Gross Cavity Cont. Proposed Budget Area or R -Value R -Value U -Factor U-Factor(a) Perimeter 3200 2400 25.0 19.0 0.027 25.0 13 0 0.033 0.055 0.069 (a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: u 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's installation instructions. Li 2. Windows, doors, and skylights certified as meeting leakage requirements. O 3. Component R -values & U -factors labeled as certified Li 4. No roof insulation is installed on a suspended ceiling with removable ceiling panels. O 5. 'Other' components have supporting documentation for proposed U -Factors. ❑ 6. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the insulation. u 7. Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized dampers. ❑ 8. Cargo doors and loading dock doors are weather sealed. u 9. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283, are sealed with gasket or caulk. u 10.Building entrance doors have a vestibule equipped with self-closing devices Exceptions: J Building entrances with revolving doors. J Doors not intended to be used as a building entrance ❑ Doors that open directly from a space less than 3000 sq. ft. in area. ❑ Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doors. J Doors opening directly from a sleeping/dwelling unit. Project Title: Data filename' Report date: 06/04/18 Page 1 of 6