Loading...
HomeMy WebLinkAboutPlans3 #4 REBAR (MIN) TIE DOWNS \ \\10' OFFSET FROM PROPERTY EXISTING BOUNDARY GRAVEL ACCESS ROAD / / I I DOSING TANK 1250 GAL I SEPTIC TANK-- MOUND AN —MOUND FOOTPRINT I AREA / ' •� \ /� BUILDING I ENVELOPE I I II I I I 2" PVC ��BUILDING / FORCE MAIN I I DELI \\ I I► SITE PLAN � \ SCALE: 1"=50' \ \ PROPERTY BOUNDARY 100' WELL SETBACK SOLID CAP FOR SUPPORT ® BOTTOM 0 OF TRENCH OR BED 0 REMOVABLE CAP FINISH GRAD[ 4 - 1/2"0 HOLES SOLID PIPE 4" COUPLIn COUPLING 4" SEWER PERFORATED PIPE WRAPPED WITH FILTER FABRIC COMBINATION AIR VENT & INSPECTION WELL DETAIL N.T.S. 2" SOLID PVC FROM DOSING TANK PIPE LATERAL LAYOUT (FOR PRESSURE DOSING OF FIELD a d a N.T.S. 2 #4 BARS EXISTING ACCESS ROAD/BERM d SLOPE TO DRAIN C a AWAY FROM MOUN ANCHORAGE FOR TANKS v 1 C.Y. WEIGHT BLOCK EACH SIDE OF TANK TANK ANCHORAGE DETAIL SECTION VIEW THRU TANK N. T. S. 4" I. PVC WYE F" RISER 45' SWEEP BEND o� CLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N. T. S. s1.00" r --------------i 1 I 1 I 75.00" I I I I I 1 L -------------J 31" -- 24' -H 21 GALLONS PER INCH 304 GALLON RESERVE LECTRICAL SPLICE Box MON 114 BALL VALVE zo J. t + ORENOOPVU57-1819 EFFLLENTPUM ORENCO P300511 1000 GALLON DOSING TANK/ HI HEAD PUMP/ PVU67 VERIFY PUMP AND VAULT SPECS WITH ORENCO PRIOR TO ORDERING 2" SOLID PVC FROM DOSING TANK 66'f MOUND t 42' o INSPECTION WELL n T 06 0 0 ` N EDGE OF GRAVEL BED SOUTH EDGE OF EXISTING ACCESS ROAD L750 SQ. FT. \---1-1 2" PERFORATED PVC DISTRIBUTION LATERAL (GRAVEL AREA) PLAN VIEW OF MOUND N.T.S. VICINITY MAP SECTION 32, 177S, R87W, 6TH PM SCALE: 1"=400' t GENERAL NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW: 4 BEDROOMS •2 PERSONS/BEDROOM •75 GALLONS/PERSON/DAY IS 600 GPD = AVERAGE DAILY FLOW SEPTIC TANK: MINIMUM TANK SIZE IS 2 • 600 = 1200 GALLONS MINIMUM GRAVEL BASE AREA: A= Q = 600 = 632 SQ.FT. 0.95 0.95 MINIMUM SAND FILL BASE AREA: A= 600 GPD =750 SQ. FT, 0.8 GPD/SQ. FT. 3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS PRESENT. 4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD. 5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN 1/2 -FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION AREA USING DRAINAGE SWALES AS NECESSARY. 9. PERCOLATION TESTING NOT PERFORMED DUE TO GRAVEL SOILS AND HIGH WATER TABLE. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMfT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. THE SAND MUST BE THOROUGHLY SETTLED BY FLOODING OR OTHER MEANS BEFORE THE DISTRIBUTION IS PLACED AT THE FINAL GRADE, 13. SAND USED SHALL BE AS FOLLOWS: SIEVE SIZEMASSING 4 100 40 10-100 200 0-3 UNIFORMITY COEFFICIENT=D / Q 41os TYPICALLY CONCRETE OR MASONARY SAND IS ACCEPTABLE. 14. SITE PLAN INFORMATION PROVIDED BY CLIENT. MOUND SYSTEM SPECIFICATIONS 1. THE MOUND SHALL BE PLACED PARALLEL TO THE CONTOURS. 2. GRASS, SHRUBS AND TREES SHALL BE CUT CLOSE TO THE GROUND SURFACE AND REMOVED FROM THE SITE. 3. THE MOUND SITE SHALL BE TILLED TO A DEPTH OF 8 INCHES TO ROUGHEN THE SURFACE AND INCORPORATE THE VEGETATION. THIS CAN BE DONE WITH A PLOW OR CHISEL TEETH MOUNTED ON A TOOL BAR ATTACHED TO THE BUCKET OF A BACKHOE. 4. A LAYER OF SAND SHOULD BE PLACED ON THE TILLED AREA. PLACEMENT OF THE SAND SHOULD BE SUCH AS NOT TO RUT OR COMPACT THE TILLED AREA. ALL WORK SHOULD BE PERFORMED FROM THE SIDE SO AS NOT TO COMPACT THE TILLED AREA. 5. PLACE THE PROPER DEPTH OF SAND, THEN FORM THE SAND/GRAVEL INTERFACE AREA WITH THE AREA BOTTOM BEING LEVEL. 6. PLACE THE SCREENED ROCK (AGGREGATE) TO THE SPECIFIED DEPTH AND AREA. 7. PLACE THE PRESSURE DISTRIBUTION PIPE, CONNECT IT TO THE FORCE MAIN AND COVER WITH AGGREGATE. 8. COVER THE AGGREGATE WITH A GEOTEXTILE FILTER FABRIC. 9. PLACE A MINIMUM OF 12 INCHES OF SUITABLE SOIL COVER ON THE SIDES OF THE MOUND AND TO THE NECESSARY DEPTH FOR GRADING ON THE TOP OF THE MOUND, 10. FINAL GRADE THE MOUND AND SURROUNDING AREA WITH LIGHT WEIGHT EQUIPMENT SO SURFACE WATER MOVES AWAY FROM THE MOUND AND DOES NOT ACCUMULATE NEAR THE MOUND. 11. SEED AND MULCH THE ENTIRE EXPOSED AREA TO AVOID EROSION. LANDSCAPE WITH SHRUBS AND PLANTS AS DESIRED. W Q >o O Z O 0 m LLJ Y Q Lwo 0 (n �oC4 O O �0- � Q °_o U Q IQ �o' o Q (� \ O� N �m� w o V �00 a 00 W Q >o O Z m LLJ U) (n 0z n Ld Z Q N d w Q 00 LLf p m N N O la- D - W LLQ m z (-D uj0 > O Q LLJC) F 2 J o v o m O ; Z Z z p W Q >o O Z