Loading...
HomeMy WebLinkAboutStructural Calculations 04.04.2018Structural Calculations For Biggs Residence 3385 County Road 311 New Castle, Colorado April 4, 2018 CIVCO Engineering Inc Civil Engineering Consultants Vernal, Utah 1256 W. 400 5. Office: 435-789-5448 P.O. Box 1758 Fax: 435-789-4485 Vernal, UT 84078 www.civcoengineering.com *Boise Cascade BC CALC® Member Build 6578 Job name: Address: City, State, Zip: Customer: Code reports: Report PORCH FRAMING 3385 CR 311 New Castle, CO Biggs WCLIB/WWPA Single 4 x 4 HF #2 TYPICAL PORCH COLUMN Dry 1 10-00-00 File name: Description: Specifier: Designer: Company: BIGGS FRAMING Vance King Vance King CiVCO Engineering, Inc. PASSED 1 April 4, 2018 08:51:30 Load Summary Tag Description Load Type 1 ROOF BEAM Conc. Pt. (lbs) REACTION Bracing Top Base Elevation Sta rt n\a Sheathing Live Dead Snow Wind End 100% 90% 115% 160% n\a 290 2200 Roof Live 125% Controls Summary Axial Compression Slenderness Ratio 10-00-00 00-00-00 Bearing Supports Dim. JLxW) Value Value n\a 34.29 % Allowable Duration 65.3 % 115% 68.6 % n\a % Allowable Duration Material Case 1 0 Wall 3-1/2" x 3-1/2" 2518 lbs Notes 0.4 % 115% Steel A generic column cap was used in the analysis of the column. Make sure to install and size the cap. BC Calc does not perform shear wall or connection design for in -plane load transfer. The analysis of solid sawn wood members is in accordance with the NDS and is limited to the output shown above. All other support and design for these products, including but not limited to notching, connections, installation, and engineer/architect certification is the responsibility of the project's design professional of record. BC CALC® analysis is based on IBC 2009. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER® , AJSTM, ALLJOIST®, BC RIM BOARDTM, BCI®, BOISE GLULAMTM, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, VERSA -RIM®, VERSA -STRAND®, VERSA -STUD® are trademarks of Boise Cascade Wood Products L.L.C. Page 1 of 3 Top 10-00-00 3 5" 3.5" r Boise Cascade 111 BC CALC® Member build 65/8 Job name: Address: City, State, Zip: Customer: Code reports: Report PORCH FRAMING 3385 CR 311 New Castle, CO Biggs WCLIB/WWPA Single 2 x 6 HF #2 TYPICAL PORCH ROOF JOIST Dry 12 spans 1 R cant. 1 24 OCS 1 Repetitive File name: Description. Specifier: Designer: Company: BIGGS FRAMING Vance King Vance King CiVCO Engineering, Inc. PASSEID April 4, 2018 08:51:30 2 12 B1 08-00-00 Total Horizontal Product Length = 09-00-00 Reaction Summary (Down / Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live B2 01-00-00 B1, 3" 33/0 B2, 3" 40/0 Load Summary Tag Description 1 Standard Load Controls Summary Pos. Moment Neg. Moment End Shear Cont. Shear Total Load Deflection Live Load Deflection Total Neg. Defl. Max Defl. Cant. Max Defl. Span / Depth 325 / 0 397 / 0 Load Type Ref. Start Unf. Area (Ib/ft2) L 00-00-00 Value 660 ft -lbs -44 ft -lbs 336 lbs 339 lbs L/346 (0.275") L/380 (0.25") 2xU1998 (-0.11") 0.275" -0.11" 17.0 Bearing Supports Dim. (LxW) Live Dead End Loc. 100% 90% 09-00-00 Top 4 % Allowable Duration Case Location 71.7 % 115% 5 04-01-00 4.8 % 115% 6 08-00-00 35.4 % 115% 5 00-03-00 35.7 % 115% 7 07-10-08 52.0 % n\a 5 04-01-00 63.1 % n\a 8 04-01-00 n\a n\a 5 09-00-00 27.5 % n\a 5 04-01-00 n\a n\a 5 09-00-00 Value % Allow % Allow Support Member Material B1 Beam 3" x 1-1/2" B2 Beam 3" x 1-1/2" 358 lbs 438 lbs 19.6 % 19.6 % Hem -Fir 24.0 % 24.0 % Hem -Fir Slope and Cut Length Slope Fascia Depth Horiz. Length Plumb Cut with Hanger to dbl. top plate 2/12 5-9/16" 09-00-00 Notes Product Length 09-02-07 Design meets Code minimum (L/180) Total load deflection criteria. Design meets Code minimum (L/240) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Design meets arbitrary (1") Cantilever Maximum Total load deflection criteria. Calculations assume member is fully braced. BC CALC® analysis is based on IBC 2009. Design based on Dry Service Condition. The analysis of solid sawn wood members is in accordance with the NDS and is limited to the output shown above. All other support and design for these products, including but not limited to notching, connections, installation, and engineer/architect certification is the responsibility of the project's design professional of record. Cantilevers require sheathed bottom flanges, blocking at cantilever support and closure at ends. Page 2 of 3 Snow Wind Roof Tributary Live 115% 160% 125% 40 02-00-00 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTM, ALLJOIST®, BC RIM BOARDTM, BCI® , BOISE GLULAMTM, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS® , Boise Cascade BC CALC® Member Build 6578 Job name: Address: City, State, Zip: Customer: Code reports: Report PORCH FRAMING 3385 CR 311 New Castle, CO Biggs WCLIB/WWPA Double 2 x 10 HF #2 TYPICAL ROOF BEAM (Roof Beam) Dry 11 span 1 No cant. File name: Description: Specifier: Designer: Company: BIGGS FRAMING Vance King Vance King CiVCO Engineering, Inc. PASSED April 4, 2018 08:51:30 1 1 1 B1 0 12 1 1---1 1 l 1 4 1 4 1 1 4 1 1 1 1 l 1, 4 1 1 1 1 1 0 4 1 4 4 1 11-oo-oo Total Horizontal Product Length = 11-00-00 Reaction Summary (Down / Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live B2 B1, 3-1/2" 145 / 0 B2, 3-1/2" 145 / 0 Load Summary Tag 0 1 Description Self -Weight ROOF JOIST REACTIONS Controls Summary Pos. Moment End Shear Total Load Deflection Live Load Deflection Max Defl. Span / Depth Load Type Unf. Lin. (Ib/ft) Unf. Lin. (Ib/ft) Value 3144 ft -lbs 1004 lbs L/517 (0.245") L/586 (0.216") 0.245" 13.7 Bearing Supports Dim. (LxW) 1100 / 0 1100/0 Ref. Start End Loc. L 00-00-00 11-00-00 Top L 00-00-00 11-00-00 Top % Allowable Duration 82.0 % 115% 31.5 % 115% 34.8 % n\a 41.0 % n\a 24.5 % n\a Live Dead Snow Wind Roof Live 100% 90% 115% 160% 125% 6 20 200 Case Location 4 05-06-00 4 01-00-12 4 05-06-00 5 05-06-00 4 05-06-00 % Allow % Allow Value Support Member Material B1 Column 3-1/2" x 3" B2 Column 3-1/2" x 3" Cautions 1245 lbs 14.8 % 29.3 % Hem -Fir 1245 lbs 14.8 % 29.3 % Hem -Fir For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain -on -Snow surcharge load. Notes Design meets Code minimum (LJ180) Total Toad deflection criteria. Design meets Code minimum (L/240) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Calculations assume member is fully braced. BC CALC® analysis is based on IBC 2009. Design based on Dry Service Condition. The analysis of solid sawn wood members is in accordance with the NDS and is limited to the output shown above. All other support and design for these products, including but not limited to notching, connections, installation, and engineer/architect certification is the responsibility of the project's design professional of record. Page 3 of 3 Disclosure Tributary 00-00-00 n \a Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER® , AJST" ALLJOIST®, BC RIM BOARDTM, BCI® , BOISE GLULAMTM, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS® ,