HomeMy WebLinkAboutOWTS Design Report 09.13.2018Huddleston-Berry
Engineering & Testing, LLC
RECEIVED
sEP 2 0 2018
GARFIELD COUNîY
G@ünmilMrlIìr !$Fv.Ettopflffili r
640 White Avenue
Grand Junction, Colorado 81501
Phone: 970-255-8005
Fax: 970-255-6818
Info@huddlestonberry. com
September 73,2018
Project#01 852-0001
Javier Orozco
336 Evergreen Drive
Rifle, Colorado 81650
Subject: OWTS Design
3 Native Springs Drive
Rifle, Colorado
Reference Subsoil Study for Foundation Design and Percolation Testing, Proposed
Residence, Lot 11, Native Springs,2T Native Springs Lane, Rifle, Colorado by H-
P Kumar for Javier Orozco, August 6,2018.
Dear Mr. Orozco,
At your request, Huddleston-Berry Engineering & Testing, LLC completed design of an Onsite
Wastewater Treatment System (OWTS) for a single-family residence at 3 Native Springs Drive
in Garfield County, Colorado. The site location is shown on Figure I - Site Location Map. A
site plan is included as Figure 2.
Site Description
As indicated in the referenced report, the site was vacant at the time of the subsoil study. The
site was described as sloping down to the west at a grade of 5 to 10%. Site topography is shown
on Figure 2. Yegetation consisted of grasses and weeds. In addition, an existing water well and
active irrigation ditch were observed at the site.
Subsurface nvestiøation
As discussed in the referenced repoft, two profile pits and three percolation pits were excavated
in the vicinity of the proposed absorption bed. The test pits encountered approximately 1.0 foot
of topsoil above silty to clayey sand soils to the bottoms of the excavations. Groundwater was
observed in the test pits at depths of between 7 .0 and 8.0 feet. The locations of the test pits are
shown on Figure 2. Copies of the test pit logs are included in Appendix A.
Onsite'Wastewater Treatment System
As indicated in the referenced report, percolation testing was conducted in the percolation pits in
accordance with Garfield County regulations. The percolation rate in the native soils ranged
from 34 to 120 minutes-per-inch with an average of approximately 78 minutes-per-inch. The
percolation testing data are included in Appendix B.
3 Native Springs 7@1#0r852-ooor (¿f;8,j)"!'i**":tLl,fi:,toe/13il8 \ø "
In addition to the percolation rate of the subsurface materials, the seasonal high groundwater
elevation is an important factor in determining the suitability of the site for Onsite 'Wastewater
Treatment Systems. For OWTS suitability, the seasonal high groundwater elevation should be at
least four feet below the bottom of the proposed absorption bed. As discussed previously,
groundwater was encountered at depths of between 7.0 and 8.0 during the subsurface
investigation. In general, based upon the time of year thaf the subsurface investigation was
completed, HBET believes that the seasonal high groundwater elevation is deeper than 6.0 feet
below the existing grade in the vicinity of the proposed absorption bed.
Seepøge Bed Design
The design of the absorption system generally follows the requirements of Garf,reld County as
outlined in the Garfield County On-Site Wastewater Treatment System (O!4/TS) Regulations,
effective June 30, 2014. The proposed construction at the site is anticipated to include a four
bedroom home.
Based upon the soil percolation rate, a Long Term Acceptance Rate (LTAR) of 0.20 will be
utilized for the absorption field design. Infiltrator Systems Quick4 Standard Chambers are
proposed in lieu of a conventional gravel absorption bed. The daily flow of the sewage disposal
system is calculated below and a plan and profile of the absorption bed are shown on Figure 3.
Average Daily FIow: (4 bedrooms)(2 persons/bedroom)(75 GPD/person)
:600 GPD
Soil Treatment Area : (600 GPD / 0.20):3,000 Square Feet
Adjusted Soil Treatment Area : (3,000 SFXl.2X0.7):2,520 Square Feet
# of Quick4 Chambers: (2,520 I 12):210 Chambers; Use 216 Chambers
System Installation
The installation of the septic tank, plumbing lines, Infiltrators, etc. should be completed in
accordance with the Garfield County On-Site Wastewater Treatment System Regulations and
Infrltrator Systems, Inc. specifications. In addition, the following construction procedures are
recommended:. The septic tank and distribution box should be placed level over native soils that have
been scarified to a depth of 8 to 12 inches, moisture conditioned, and recompacted to
a minimum of 95Yo of the standard Proctor maximum dry density, within +2o/o of
optimum moisture content. However, up to 3-inches of washed rock or pipe bedding
passing the 1-inch sieve may be used as a leveling course under the septic tank and/or
distribution box.. The bottoms of trenches and backfill around the septic tank and distribution box
which will support sewer or effluent lines should be compacted to at least 90 percent
of the standard Proctor maximum dry density, within +2%o of optimum moisture
content. Pipe bedding should have a maximum particle size of l-inch.. Vehicular or heavy equipment traffic and placement of structures should not encroach
within 10 feet of the septic tank or distribution box.
2X:U008 ALL PROJECTS\01 852 - Javier Orozco\Ol 852-0001 3 Native Springs\200 - Geo\o1 852-0001 LR09 l2l 8.doc
3 Native Springs
#018s2-0001
09n3/t8
Hud¡llcston-Bcrry
bdñshrÅ ¡i{bt. LrC
Inspectìon Schedule
Huddleston-Berry Engineering & Testing LLC should be retained to monitor the construction of
the O'WTS. The following schedule of observation ancl/or testing shoulcl be followed:. Observe the absorption bed excavation prior to placement of Infiltrator chambers.. Observe placement of the septic tank, distribution box, and all connecting sewer and
effluent lines prior to backfill. Veri$, proper fall between inverts.
' Observe and verify installation of the absorption bed prior to placement of cover and
backfill.
In conformance with Garfield County regulations, HBET will be required to provide Garfield
County with documentation certifying that the OWTS was placed in conformance to the plan and
profile and Garfield County regulations.
General Notes
The OWTS design was based upon the results of the subsurface investigation and on our local
experience. The design is valid only for the proposed construction
We are pleased to be of service to your project. Please contact us if you have any questions or
comments regarding the contents of this report.
Respectfully Submitted:
Huddleston-Berry Engineering and Testing, LLC
Michael A. Bemy, P.E.
Vice President of Engineering
JX:U008 ALL PROJECTS\o1 852 - Javier Orozco\o1 852-0001 3 Native Springsuoo - Geo\o1 852-0001 LR09l2l 8.doc
FIGURES
G Garfield Gounty Land Explorer
GørJield County
Garfield Gounty, Colorado
1ô.{,
!¡¡üs
q.
/-ì +o
I
A"tú
Å
FIGURE 1
Site Location Map
.+'
0.8 Mileso.2 0.4
1 inch = 1,505 feet
1 inch = 0.28 miles
Garfield County Colorado
ww,garf ¡eld-county, co m c¡lorådoGarfield County
Garfield Gounty Land Explorer
Printed by Web User
Dlsclâimer
Thls ls a comp¡latlon of rëcords as ffêy ¡ppê!r ln ùe cafléld øunq ofr.6s åffod¡nc th6 6rea shown, Thls dr.wlns ls
b be usêd onlylor reteÈ ncå purp6os End th6 Gunty È nd ré5poñlble for ¡ny ln¡eur..¡es heEln.onbinêd.
O copyright Garf¡eld county, colorado I A:l R¡ghts Reserved Printed: g/13/2o1s âL172124 PM?#Æ
3 NATIVE SPRINGS DR.FIGURE2-SITEPLANHuddleston-BerryEngincering & Tesl¡ng, LLCó40 whire Avenue, unit BGrand Junction, CO 8i501Project No.: 01 852-0001Date: 09/13/18By: MABDRAINAGE EASEMENTwdl6 '1t595GAL10,c)'LôU).cLo(no,ìzREPLACEMENT AREALot 11J Ndh SÞfrF Drh+.507MBLE PN IAIE¡Ss 89'34'41" W 4J6.74'Èpw JE2.29'stohpd 6 ¡eSS15' UTIL1TY AND IRRIGATIÍINCounty Road No. 221(ee b.)SCALE: 1":60'A rpsr Prr (APPRoxTMATE)RDruE PIIBomt'."C.I.:1FT
DETAIL AREASCALE:1"=20'4.INCH DIAMETER SEWER ANDEFFLUENT PIPE MEETNG ASTMDI785, SCHEDULE 40 OR SDR 35INFILTfu\TOR SYSTEMS10,STANDARD CHAMBERSSEPT]C TANK WITHMINIMUMC-\LLON6', mNtxnDISTRIBUTIÔN BOXËS TIÍATENSURE EVÊNOF EFFLUENT**usE swEEP 90,s oRTWO 45'S AT 90DÊGR.EE tsENDS**3 NATIVE SPRINGS DR.FIGURE3-SEPTICSYSTEMDETAILSHuddleston-BerryEnginccring & Tcstïng, LLCó40 White Avenue, Unít BGrand Junction, CO 81501Project No.: 01852-0001Date:09/13/i8By: MABGEI{ERALIZED SYSTEM PROFILENof TuSCALERES]DENTIALSIRUCTURERISERS (AS NECESSARY)THAT LIDS ARE AT ORINFILTRATER OUICK4STANDARD CHAMBERSFINISHE¡ GRADE1,0 FT wN, cwRDN ETLUENTEST. 6.0TO A.O FTESTFT1,0 FT HIN.4,0ntg,30xEsTANKGENERALIZED BED PROFILEN¡T TBSCALETNFILTRATOR SYSTEMS QUICK4COVER SOILì NATTVE SOILS OR OTHER SUITABLETOPSOIL. CRADE TO CARRY SUR¡ACE WATERSTANDARI)BED.NEEDLE PUNCHED.FABzuC IMMEDIATELY ABOVE CHAMBERSMINIMUM SETBACKS(UNITS = F.T)rcPEgY LMt01010UNOryIE¡&uñryELUE1020LAXE, SIW,NNE! MCHÐI:l@ÐFrut0æ!0ffimcHbúúGATÐ HPE10ã10VAIER ÑE10át0tr10050**OTHER SETBACKS NOT LISTED HERE SHOULD BE IN ACCORDANCE WITH GARFiELD COLNTY OWTS REGULATIONS
APPENDIX A
Typed Test Pit Logs
t:
¡;
PIT 1
EL. 91'
PIT 2
EL. 96
PROFILE PIT 1
EL. 95.5'
PROFILE PIT 2
EL. 94.5'
0 0
WC=15,7
DD= 1 03
-200=67 -l
¡_l
F
tJJ
UJl¡
ITÞ-fL
t¡Jô
WC= 1 5.7
DD= I 04 WC=19.0
DD= 1 02
¡-.LIt¡lt&
I
:Et--o-
Lrjô
5 5
10 10
LEGEND
ñ
TOPSOIL: SAN0. SILTY, ÇLAYEY, ORGANIC, STIFF' SLIGHTLY MOIST' BROWN'
SAND (SC): CLAYEY TO VERY CLAYEY, SILTY, LOOSE, MOIST-WET, BROWN TO GRAYISH
BROWN.
F
l-r+
HAND DRIVEN UNER SAMPLE.
OISTURBED BULK SAMPLE.
DEPTH TO WATER TEVEL AT THE TIME OF EXCAVATION.
NOTËS.
1. THE EXPLORATORY PITS WERE EXCAVATED WITH A BACKHOE ON JULY 9,2018.
2. THE LOCATIONS OF THE EXPLORATORY PITS WERE MEASURED APPROXIMATELY BY PACING FROM
FEATURES SHOWN ON THE SITE PLAN PROVIDED.
3. THE ELEVATIONS OF THE EXPLORATORY PITS WERE MEASURED BY HAND LEVEL AND REFER TO
THE BENCHMARK ON FIG. 1 '
4, THE EXPLORATORY PIT LOCATIONS AND ELËVATIONS SHOULD BE CONSIÐEREO ACCURATE ONLY
TO THE DEGREË IMPLIED BY THE METHOD USED.
5. THE LINES BETWEEN MATERIALS SHOWN ON THE EXPLORATORY PIT LOGS REPRESENT ÏHE
APPROXIMATE BOUNDARTES BETWEEN MATERIAL TYPES AND THE ]RANSITIONS MAY BE GRADUAL.
6. GROUNDWÀTER WAS ENCOUNTERÊD IN THE PITS AT THE TIME OF DIGGING. PITS WERE
SACKFILLED SUBSEQUENT TO SAMPLING.
7. LABORATORY TEST RESULTS:
WC = WATER CONTENT ('¿) (ASTM D 2216)¡
TD = DRY DENSITY (PCT) (ISTM D ?216)i
-2QO = PERCENTAGE'PASSING NO. 200 SIEVE (ASTM D 1140).
18-7 *446 H-PryKUMAR LOGS OF EXPLORATORY PITS Fig, 2
APPET..{DIX B
Percolation Testing Results
H-PñI(UMAR
TABLE 2
PERCOLATION TEST RËSULTS
PROJECT NO. 18-7-446
Note: Percolation test holes were hand dug in the bottom of backhoe pits and percolation tests
were conducted on July 9,2018. The average percolation rates were based on the last two
readings of each test.
HOLE NO.HOLE DEPTH
(rNcHEs)
LENGTH OF
INTERVAL
(MrN)
WATER
DEPTH AT
START OF
INTERVAL
(rNcHES)
WATER
DEPTH AT
END OF
INTERVAL
(rNcHEs)
DROP IN
WATER
LEVEL
(rNcHES)
AVERAGE
PERCOLATION
RATE
(MrN./rNCH)
1
EAST
31 15
7 6Vz Yz
80
6Y2 6r/a t/+
6r/t 6 r/+
6 53/¿rÁ
53/e 5%YB
5%5%r/t
2
SOUTH
3I 15
7%7V2 v,
t20
7r/2 7V4 r/+
7Y4 lYs Y"
7Vs 7 Ys
7 6%%
6%63/a r/s
3
WEST
33 15
7V4 6%%
34
6%6 %
6 5%%
5%5V4 %
5r/4 Ya %
4%4%r/z