HomeMy WebLinkAboutPlansGENERAL STRUCTURAL NOTE GENERAL REQUIREMENTS 1. Design is based on the 20041 edition of the International Building Code (IBC). 2.Deslgn Live Loads: a. Roof (Snow) 40P5F b. Loft Floor (Light Storage) I25P5F c. Wind 90 MPH Basic Wind Speed 3 second gust 3.AI1 dimensions, elevations and details on structural documents shall be verified against the architectural documents prior to construction or fabrication. 4.The contract structural documents and specifications represent the completed structure. The contractor shall provide all measures necessary to protect the structure and existing adjacent structures and utilities. 5.Coordinate all openings through floors, walls and roofs with Mechanical and Electrical Contractors. Notify Engineer of any openings to be cut In structural systems. FOUNDATIONS I.Foundatlon design is based upon the following assumed soil properties: Maximum Bearing Capacity 1000 PSF. Active Soli Pressure 50 PGF. Soils are presumed to be non -expansive, non -soluble, and not prone to excessive consolidation. Specific soil properties shall be verified by the Soils Engineer upon excavation and prior to footing placement. 2.AII footings are to bear on undisturbed natural bearing materials or compacted structural fill. Gompactive effort for structural fill shall be In accordance with the Soils Engineer's recommendations. Bearing soils (natural and compacted) shall be Inspected and approved by the Soils Engineer prior to placement of footings. 3.Avold excessive wettingor drying of the excavation, keeping the excavation reasonably ree of water during placement of concrete for footings. 4.6eneral Requirements: a. Foundation walls with backfIll on only ono wall face shall have all supporting framing systems or temporary bracing In place prior to placing backfill (unless noted otherwise on plan). b. Backf I I I on NOBS rs with fill on both sides to be compacted in equal lifts each side of wall. CONCRETE AND REINFORGIN6 STEEL I.AII concrete shall attain 3,500 PSI compressive strength wlthIn 28 days. 2.1.1se Type 1-11 Portland Cement (ASTM CI50) with 4-6% air entrainment. Concrete aggregate to be normal weight (stone). 3.Perform all cast -in-place concrete work in accordance with "Specifications for Structural Concrete for Buildings," AGI 301-84, unless noted otherwise. Provide hot or cold weather protection per AGI 305 or 306. 4.Reinforcing steel shall conform to ASTM A615: *4 and smaller &rade 40; *5 and larger &rade 60 5.Horizontal reinforcingsteel shall be made continuous by lapping bars a minimum of 3bar diameters at all splices and providing corner bars. Fabrication and installation of reinforcing steel shall conform to AGI 315. 6.Provlde accessories necessary to properly support reinforcing at the positions shown on the documents. 7.Calclum chloride or admixtures containing more than 0.05% chloride Ions or thiocyanates are not permitted. 8.Do not place pipes, ducts or chases in structural concrete without prior approval of the Structural Engineer. STRUCTURAL WOOD FRAMING A. DIMENSIONAL LUMBER I.AII timber construction (light and heavy) shall conform to American Institute of Timber Construction (AITG) and National Design Specification (NDS) standards. 2.Structural framing lumber shall be Douglas FIr Larch, with the following minimum grades: Plates and Studs: 02 Joists and Rafters: *2 Beams, Posts and Timbers *1 3.AII sill plates In contact with concrete or masonry foundation shall be Foundation Grade Redwood or Pressure Treated Hem-FIr *2 or better, designated for "Above &round" usage as defined by the American Wood Preserver's Institute. 4.61u -laminated members shall be Douglas Fir/Larch as follows: conform to AITG symbol 24F -V5 or better (Fb = 2400 PSI; Fv = 165 PSI; E = 1,800,000 PSI), unless noted otherwise. 5.Bolse-Cascade products shown shall be as manufactured by the Boise -Cascade Corp., Boise, Idaho. Boise -Cascade products include: BGI's, Rim Boards, and LVL Headers. Installation details, blocking, bracing and connections shall conform to the requirements of the manufacturer. &.Laminated Veneer Lumber (LVL) shall be designed and fabricated In accordance with the National research Board and the National Design Specification for wood. LVL's to be 144" thick with the following minimum working stresses: Fb = 2600 PSI; Fv = 285 P5I; E = 1,800,000 PSI 7.11400d manufactured products other than those noted, which have I.G.G. approval, may be used wIth approval of the Engineer. B. FASTENERS AND CONNECTORS I. All timber nailing and connections shall conform to IBC and AITG. Reference IBC Table No. 2304.9.1: Fastening Schedule. 2.Metal connectors for wood framing are manufactured by the Simpson Strong -Tie Company, connectors with nails shorter than common as follows: 8d x 14"; IOd x 11"; I6d x 21.t", unless noted otherwise. 3.Alternate connections and fasteners to those listed above, which have I.G.G. approval, may be used upon approval by the Engineer. STRUCTURAL STEEL I.Deslgn, fabrication and installation of structural steel shall conform AISG and AWS specifications. 2.Steel other than pipes and tubes shall be ASTM A56 (minimum yield strength = 36 KSI). Pipe columns shall be ASTM A55-6 (minimum yield strength = 35 K51) Tube steel (TS) shall be ASTM A500, &rade B (minimum yield strength = 46 K51) 3.Connectfon bolts and anchor bolts shall be ASTM A307 unless noted otherwise. Minimum of 2 bolts per connection. 4.Fillet We Ids shall be made with E70XX rod, size 3/16" and continuous unless noted. 5.6roove welds shall be made with E70XX rod, and be full penetration and continuous, unless noted otherwise. WOOD ROOF TRUSSES 1. Provide open web trusses as profiled on the documents to safely support the Indicated dead and live Toads. 2.Truss manufacturer shall be a member of the Truss Plate Institute (TPI) and Component Manufacturer's Council. Trusses shall be designed by a Professional Engineer employed by the manufacturer. 3.Lumber for trusses shall be of the species and grade as required by the Engineer's design. &rade stamp each piece. 4.Manufacture and install press-fit metal plates complying with TPI -74. 5.Manufacturer shall submit shop drawings to Architect for review and approval. Shop drawing shall Indicate truss pitch, span, and spacing; gage, size and location of connectors; bearing and anchorage details, truss -to -truss connections, bridging and permanent bracing details; and all related items. 6.Submit shop drawings to the engineer for review and approval. 7.Submit design calculations, bearing the seal of the Manufacturer's Engineer, wIth the shop drawings, indicating species and grade of lumber, design loadings, and force analysis of each member and design of each connection. B.Fabricate trusses according to approved shop drawings. Provide trusses and all related Items required for erection, to include blocking, bridging and permanent bridging. 9.Snow load duration factor 1.0 a. Truss top chord dead load 12.0 PSF b. Truss bottom chord dead Toad 10.0 PSF PROVIDE 4' THICK CONCRETE SLAB -ON - GRADE OVER 4' THICK LAYER OF FREE DRAINING GRAVEL - COMPACT EXISITN6 SUB -GRADE REINFORCE SLAB W/ 6xb-1442.1 x 1042.1 WELDED WIRE FABRIC (W.W.F) SUPPLY IN FLAT SHEETS *4 x 20"-x114" O Ib' O.G. x I'-0" PROVIDE CONTINUOUS TREATED 2x4 SILL PLATE W/ 1/2' dia ANCHOR BOLT 0 4'-0" 0.G. MAXIMUM CONTINUOUS `TREATED' 2x4 LEDGER W/ GI/64" dia POWDER DRIVEN NAIL 0 12" 0.G. CONTINUOUS ICE 4 WATER SHIELD 1111 SII M 2" THICK _ RIGID INSULATION- _ EXTRUDED POLYSTYRENE J 3/4" = I' -O" STRUCTURAL WALL SHEATHING (1/16" PLYWD)-TYP AT EXTERIOR WALLS - SEE PLAN FOR ADDN'L LOCATIONS BUILT-UP POST EDGE NAILS EMBED LG ATTACH HD TO FON IN/ 'NEEDLE -CAPSULE' ADHESIVE ANCHORS (MFR= THE POWERS FASTENING GROUP) OR EQUAL PER SCHEDULE U HOLD-DOWN ANCHOR (HD) AS MFR'D BY SIMPSON GO. - SEE PLAN FOR LOCATION. BOLT TO BUILT-UP POST (2-2x6 MIN) PER MANUFACTURER'S RECOMMENDATIONS FOUNDATION WALL (REINF. NOT SHOWN) HD ADHESIVE ANCHOR BOLT DIA. Emmy 6 HOLE DIA. HDU2-SDS2.5 5/8" 5.1/2" 11/16" HDU 4-3D32.5 5/6 " 5.1/2 " I I /16 " PHD2 5/8" 5.1/2" II/16" INSTALL ADHESIVE ANCHORS PER ALL MANUFACTURER'S RECOMMENDATIONS. 5/4" = I'-0" SHEATHING NOTES 1. Sheathings shall be American Plywood Association (APA), Exposure 1, G -D plywoods or oriented strand board (0.5B.) as follows: Floors .23/32" thick, APA rated Sturd-I-Floor, 24 0.C., T 4 6 Roofs 15/32" thick, APA rated sheathing, 52/16. Provide Plycilps midway between rafters at unsupported sheet edges. Walls 7/16" thick, APA rated sheathing, 24/0, all edges blocked. 2. Sheath exterior face of all exterior frame walls with APA sheathing unless noted otherwise on structural drawings. 5. Do not block floor and roof sheathing edges unless noted. 4. Plywood floor sheathing to be glued and nailed to the floor joists using adhesives conforming to APA Specification AF6-0I and applied in accordance with manufacturer's recommendations. Remove dirt and water from joists, apply glue to joists and complete all nailing before glue sets. 5. Floor and roof sheathing layout. 6. NAILING Framing Members USE NAILS (Deformed shank) NAIL SPACING COMMENTS a Intermed. Supports a Sheet Edges Floor 8d (.131" 0) 12" 6" Roof 8d (.151" 0) 12" 6" Wall 8d (.151" 0) 12" 6" Note: 1. Nall diameter of .131" is equivalent to 8d common or 12d sinker nails. Mechanically driven nails of equal or greater diameter which penetrate the framing members at least 1.3/4" may be used. BASE PLATE I"x10"xl0" W/ (4)-5/8" dia. ANCHOR BOLTS OR EXPANSION ANGH.'S- TYP a STEEL COL'S- U.N.O. 1" DRYPACK - x x -X-- cue REINF. - SEE FT6 SCHEDULE STEEL COL W.W.F. - SEE TYPICAL DETAIL :rHCCT 5-1 EQUAL BEAR ON UNDISTURBED GRANULAR BEARING SOILS EQUAL SEE PLAN 5/4" - 1,1-0" BASE PLATE I "x10"x10" W/ (4)-5/8" dia. ANCHOR BOLTS OR EXPANSION ANCH.'S- TYP a STEEL. COL'S- U.N.O. 1" DRYPACK -N EQUAL A STEEL. COL SAW -CUT EXIST. 5.0.6. ALL AROUND /5J SEE PLAN 3/4" = 1'-0" KURTZ ASSOC I ATES, IN. 5012 COUNTY RD . 154 GLENWOOD SPRI NGS, COLORADO (a1o) 145-6305 Al TRAFFIG CONTROL GARAGE REMODEL 325(7 HWY 6 4 24 SILT, COLORADO GENERAL CONTRACTOR: TSG CONSTRUCTION, INC. (110) 51c1-1251 DRAWN SY: J.L.6. CHECKED SY: S.J.K. SCALE: AS SHOWN PROJECT #: 15-14 DATE : CONSTRUCTION SET: 04/03/2015 SHEET T I TLE : GENERAL NOTES 4 1`OUNDATION DETAILS SHEET: 36-O" EXISTING HDU2- 5D52.5 48'-O" 24'-0" EXISTING I'-104" / 24'-0" ADDITION i I'-104" SIMILAR / A --EXIST. THICKENED EDGE (4 510E5) HDU2- SDS2.5 L T.O. SLAB 100'-0" DWL THICKENED EDGE TO EXISTING W/ (I)45 x 24" TOP 4 BOTTOM. DRILL 5/4" dia. x 5" HOLE IN EXISTING CONC., GLEAN HOLES 4 ATTACH DWL IN/ 2 -PART STRUCTURAL EPDXY, TYP 2 PLACES /I'-0" THICKENED / EDGE (4 5I DES) DIAL T.O. SLAB 100'-O" 3'-O" 5'-0" TYP 1'-0" THICKENED -1, / EDGE (4 5I DE5) m SIMILAR FOUNDATION PLAN TYPE L A SI PLAN E3 NORTH HDU2- SD52.5 CONCRETE FOOTING SCHEDULE SIZE REINFORCEMENT SI 1\_ 36'-O" ADDITION HDU2- 5D52.5 REMARKS 6'-0" X 6'-0" X 12" 6'-0" X 6'-0" X 12" 2'-6" X 6'-0" X 10" 6 - #5 EACH WAY 6 - #5 EACH WAY 2 - 4*5 LONGITUDINAL SEE 5/S SEE D/S SEE A/51 NOTES: 1. Place scheduled reinforcement 5" clear from bottom of footing. 2. Center footings below columns unless dimensioned otherwise. KURTZ A550G I ATES, INC. 5012 COUNTY RD . 154 GLENIA10012 SPRI NGS, COLORADO (c41o) ci45 -6305 Al TRAFF I G CONTROL GARAGE REMODEL 325'11 HYAIY 6 4 24 SILT, COLORADO GENERAL CONTRACTOR: T5G CONSTRUCTION, INC. (170) 311-1231 DRAWN BY: J.L.G. CHECKED BY: E3.J.K. SCALE : A5 SHOWN PROJECT #: 15-14 DATE : CONSTRUCTION SET: 04/03/2015 SHEET T I TLE : FOUNDATION PLAN SHEET: WIO STEEL BM W/ WOOD PACK -OUT NAIL BUILT-UP POSTS IN/ (2)-I6d @ lb" O.G. BUILT-UP POST SEE PLAN I6d NAILS at 3" O.G. TO BM ADDN'L 2x FULL HT. EACH SIDE POST 4 BM III - 11-0" 1-OII (A) \ \ \ 9 0 48'-O" 24'-0" EXISTING BELOW 24'-O" ADDITION BELOW 12'-O" 24'-0" 12'-0" 2x6 LOOK -OUT e 24" O.G. Q 9 1 MONO -P ITCH TRUSS 24" O.G. 2x6 LOOK -OUT ® 24" O.G. 1 7 1 1 1 1 1 1 zl 01 z. 1 0 1 1 1 2 -SPAN CONT. E3C @ 16" O.G. UPPER FLOOR 4 LOWER ROOF FRAMING PLAN NOTES: ® 24" O.G. 2x6 LOOK -OUT 9- OPEN (1)-1 1.7/8" LVL T.O. PLYWD 113'-4" HDR ��^EXIST. WALL: 2x4 ® I6" O.G. (SEE PLAN NOTE NO. 14) c Ir •m 0 1 1 1 1 1 1 1 1 c 1 —HDR MONO -PITCH TRUSS 24" O.G. ac A STORAGE LOFT ff LOWER ROOF FRAMING PLAN 2x6 LOOK -OUT 24" O.G. 1/4" = l'-0" 1. - T floor joist or roof rafter (showing joist span direction). 2. Floor joists to be BGI/60 unless noted otherwise (U.N.O.). 3. Floor sheathing to be 44" thick (nominal) tongue and groove plywood (See Sheathing Notes, sheet 5-I). f'.) 4. c -3 joist hanger or beam to beam connection. CJ 5. b. 5 designates stud wall supported on the framing at this level. 5 wood stud wall below this level of framing. Space studs at I6" on center at all exterior walls and all bearing walls. I. Minimum header size to be (2)-2x8 at 2x4 stud walls. Support headers each end with 2 studs (I Jack + I King) minimum. column or post from above that is supported on framing at this level. 10. ■ designates HDR support or post which supports framing this level. Minimum post sizes: 2-2x4 and 2-2x6 at 2x4 and 2x6 stud walls respectively. Viere the post supports a post above provide solid blocking or 'squash blocks' through the floor. Post and HDR Support Schedule: OA (3)-2x4 ® (3)-2x6 (D. (3)-2x4 (1 Jack + 2 Kings) OD (3)-2x6 (I Jack + 2 Kings) ® (4)-2x4 (3 Jacks + 1 King) ® (5)-2x6 (See A/53) GO Steel Column: TS4x4x1/4 (See D/54) PLAN ED NORTH II. 3G1 designates framing members manufactured by Boise -Cascade Corp. or approved equal. 12. LVL = Laminated Veneer Lumber. See Structural General Notes for allowable stresses. LVL's shall be 144" thick. 13. (XX' -X") = top of steel beam. I4. Provide (I) -2x4 sister stud @ each existing 2x4 stud so as to have double 2x4 studs e I6" O.G. KURTZ ASSOG I ATES, INC. 5012 COUNTY RD. 154 GLENWOOD SPRI NGS, COLORADO (QlO) '145-6505 Al TRAFF I G CONTROL GARAGE REMODEL 32511 HM(6 4 24 SILT, COLORADO GENERAL CONTRACTOR: TSG CONSTRUCTION, INC. (170) 3741-7231 DRAWN BY: J.L.G. CHECKED 3Y: S.J.K. SCALE: AS SHOWN PROJECT #: 15-14 DATE: CONSTRUCTION SET: 04/03/2015 SHEET T I TLE : STORAGE LOFT 4 LOWER ROOF FRAMING PLAN SHEET: S=5 2x4 STUDS 16" O.G. T.O. PLYWD E# PLAN CANT. RIM CONT. 2x6 WOOD PLATE (DOUGLAS -FIR NO.I, FREE OF TWIST AND WARP) - ATTAGH-TO-AIO IN/ 0.131" dia. LOW VELOCITY POWDER DRIVEN NAILS to 6" 0.G. (STAGGER) AIO 5TL BM 3/4" = 1'-0" PROVIDE CONTINUOUS FLASHING 4 VENTILATION - 2x8 BLK'G (DASHED) BETA TRUSSES - NAIL -TO -EACH STUD IN/ (2)-I6d 12 —14 MONO -PITCH TRU55 J5T HGR LU -210 - NAIL THRU SHEATHING -TO -RIM A/ (10)-16d NAILS BLOCKING PANEL BETWEEN .JOISTS BC BEARING WALL: (2)-2x4 STUDS @ 16" O.G. (SEE PLAN NOTE NO. 14) TYPICAL NAILS: 501 -T0 -SUPPORT Al 3- .131" dia. x 2.1/2" MIN., BLK'G-TO-SUPPORT IN/ .131" dia. x 2.1/2" MIN. to 12" 0.C. EA. SIDE (STAGGER) CONTINUOUS BGI SPANS I" = II -0" BEVELED L5L BLK'G BTWN TRUSSES - NOTE: BLK'G TO BE NOTCHED FOR VENTILATION: 1.1/2" fir` 1.1/2" EQUAL 14 CONT. 2x6 RIM IN/ (2)-16d NAILS TO EACH RAFTER MONO -PITCH TRUSS ATTACH EACH TRUSS EACH END IN/ H2.5 HURRICANE TIE 2x4 STUDS 3/4" = 1'-0" FULL HT STIFF PLATE 1/4" EACH SIDE DONT. Ix FASCIA NP> V STL E3M CAP PLATE 1/2" IN/ 4- 1/2" dia THREADED STUDS TS COL 1.1/2" = I'-0" ALJ O m O 24'-0" NEW LOFT BELOW L 2x6 LOOK -OUT co 24" 0.G. HDR ■ REUSED EXISTING COMMON TRUSS 24" O.G. ■ HDR L • HDR • ATTACH EACH TRUSS EACH END IN/ H2.5 HURRICANE TIE OR EQUAL ■ HDR 24" 0.G. 2x6 LOOK -OUT UPPER ROOF FRAMING PLAN 1/4" = i•ro PLAN O, NORTH 4 ROOF FRAMING PLAN NOTES 1. --.4-- --7.— Designates premanufactured roof truss, showing span direction. 2. [a Joist hanger or beam to beam connection. 3. 5 5 Wood stud wall below this level of framing. Exterior walls to be 2x4 studs @ 16" O.G.. 4. Minimum header size to be 2- 2x8 at 2x4 stud walls. 5. Support headers each end with 2 studs (I hack + 1 king) minimum. 6. ■ Designates header support or post which supports framing this level. Minimum post sizes: 2- 2x4 and 2- 2x6 at 2x4 and 2x6 stud walls respectively. KURTZ A550G I ATOS, INC. 5012 COUNTY RD . 154 GLENWOOD SPRI NGS, COLORADO (QUO) Q45-6305 Al TRAFF I G CONTROL GARAGE REMODEL 325Q 1 HIAIY 6 4 24 SILT, COLORADO GENERAL CONTRACTOR: TSG CONSTRUCTION, INC. (QUO) 3-q--231 DRAWN BY: J.L.G. CHECKED BY: B.J.K. SCALE : AS SHOWN PROJECT #: 15-14 DATE: CONSTRUCTION SET: 04/03/2015 SHEET T I TLE : UPPER ROOF FRAM I NG PLAN SHEET: 3-4