HomeMy WebLinkAboutInsulation Compliance CertificateDave Argo From: Dave Argo Sent: Thursday, May 03, 2018 8:03 AM To: 'Olivia Emery' Subject: RE: CRMS Holden Residences ResCheck Olivia: Thanks for sending over this RES -Check compliance certificate. This works for not insulating edge of slab at the duplex residence building, but we'd also like to have a COM -Check analysis for the Health & Counseling Center since it was reviewed under the 2015 I.B.C. (as a commercial building). I think you will find the COM -Check to be very similar in nature to RES -Check. Sorry for the bit of redundancy, but this will be beneficial to have both certificates in our project files. Dave Argo Plans Examiner _ Garfield County Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Tel: 970-945-8212 Ext. 1610 Email: dargo@garfield-county.com Web: garfield-county.com CONFIDENTIALITY NOTICE: This email communication and any files transmitted along with it are intended only for the person or entity to which it is addressed. If you have received this email in error, please immediately notify the sender by email and delete it from your files. From: Olivia Emery [mailto:oemery@a4arc.com] Sent: Wednesday, May 02, 2018 10:09 AM To: Dave Argo <dargo@garfield-county.com> Cc: Casey Wilkins <casey@bhgencon.com>; White Joe <jwhite@crms.org>; Faber Brad <brad@bhgencon.com>; Raaflaub Hans <hans@bhgencon.com> Subject: CRMS Holden Residences ResCheck Dave, Attached is ResCheck for the residences. I have assigned the slabs a value of 0. Will this suffice to eliminate the foundation rigid at existing foundations on both projects? Thank you. Olivia A4 A4 Architects LLC Olivia H. Emery, Principal 242 North Seventh Street 1 LTJ REScheck Software Version 4.4.4 Compliance Certificate Project Colorado Rocky Mountain School Holden Residences Energy Code: 2009 IECC Location: Carbondale, Colorado Construction Type: Single-family Project Type: Alteration Heating Degree Days. 7313 Climate Zone: 5 Permit Date: 3-9-18 Construction Site: 499 Holden Way Carbondale, CO 81623 Owner/Agent: Designer/Contractor: Joe White Olivia Emery Colorado Rocky Mountain School A4 Architects LLC 499 Holden Way 242 North 7th Street Carbondale, CO 81623 Carbondale, CO 81623 9709632562 9709636760 jwhite@crms.org oemery@a4arc.com Compliance: Passes Maximum UA: 587 Envelope Assemblies Your UA: 537 Assembly Gross Area Glazing Cavitory Cont. Perimeter or oor R -Value R -Value U Factor UA Ceiling 2: Raised or Energy Truss Wall 1: Wood Frame, 16" o.c. Window 1: Vinyl Frame:Double Pane with Low -E Door 1: Solid Door 2: Glass Wall 2: Solid Concrete or Masonry:Interior Insulation Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' 2,389 49.0 0.0 48 1,926 21.0 0.0 93 199 0.240 48 18 0.360 6 77 0.370 28 690 21.0 0.0 39 264 0.0 275 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.4 and to comply with the mandatory requirement- " " _ _ ,�� _' _ _,- .-ispection Checklist. Olivia H. Emery, Principal, A4 Architects LLC � ��ll.r�Y' 5.2.18 Name - Title Signature • Date Project Title: Colorado Rocky Mountain School Holden Residences Report date: 05/02/1 Data filename: 1707 Res Check.rck Page 1 of 8 LTJ REScheck Software Version 4.4.4 Inspection Checklist Requirements: 2.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. 2009 IECCI Pre-Inspection/Plan Review 103.2 Construction drawings and [PR1]1 documentation demonstrate energy code compliance for the building envelope. 103.2, Construction drawings and 403.7 documentation demonstrate [PR3]1 energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the commercial code. Plans Verified Value Field Verified Value 403.6 Heating and cooling equipment is Heating: Heating: (PR2]2 sized per ACCA Manual 5 based Btu/hr Btu/hr on loads per ACCA Manual.] or Cooling: Cooling: other approved methods. Btu/hr Btu/hr Complies? ❑Complies ❑Does Not ['Not Observable ❑ Not Applicable ❑ Complies ❑ Does Not ❑ Not Observable ❑Not Applicable Comments/Assumptions ❑Complies ❑Does Not :Not Observable ❑ Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) J 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Colorado Rocky Mountain School Holden Residences Report date: 05/02/1 Data filename: 1707 Res Check.rck Page 2 of 8 2009 IECC 402.1.1 [FO1]1 Foundation Inspection Plans Verified Value Slab edge insulation R -value. R- ❑ Unheated ❑ Heated 303.2, 402.2.8 [FO2]1 Slab edge insulation installed per manufacturer's instructions. 402.1.1 Slab edge insulation [FO3]1 depth/length. Field Verified Value R- ❑ Unheated ❑ Heated 303.2.1 A protective covering is installed [FO11]2 to protect exposed exterior insulation and extends a minimum of 6 in. below grade. d, 403.8 Snow- and ice -melting system [FO12]2 controls installed. ft Complies? ❑ Complies E Does Not ❑ Not Observable ❑Not Applicable ❑ Complies ❑Does Not [Not Observable ❑ Not Applicable Comments/Assumptions See the Envelope Assemblies table for values. ft ❑Complies ❑ Does Not ❑ Not Observable ❑Not Applicable ❑Complies Does Not ❑Not Observable ❑ Not Applicable See the Envelope Assemblies table for values. E Complies ❑ Does Not ❑Not Observable ❑ Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) J 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Colorado Rocky Mountain School Holden Residences Data filename: 1707 Res Check.rck Report date: 05/02/1 Page 3 of 8 2009 IECC 402.1.1, Door U -factor. 402.3.4 [FRU 402.1.1, Glazing U -factor (area -weighted 402.3.1, average). 402.3.3, 402.5 [FR2]1 303.1.3 [FR4]1 s FramingPlans Verified Field Verified /Rough -In Inspection Value Value U -factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies? Comments/Assumptions U- U- ❑Complies ❑ Does Not ['Not Observable ❑ Not Applicable See the Envelope Assemblies table for values. U- U- ❑Complies Does Not E Not Observable E Not Applicable 402.3.5 Sunrooms enclosing conditioned U- [FR8]1 space have a maximum fenestration U -factor of 0.50 in Climate Zones 4-8. New glazing separating the sunroom from conditioned space must meet code requirements. 402.3.5 Sunrooms enclosing conditioned U [FR9]' space have a maximum skylight U -factor of 0.75 in Climate Zones 4-8. 402.4.4 Fenestration that is not site built [FR2O]1 is listed and labeled as meeting AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. 402.4.5 IC -rated recessed lighting fixtures [FR16]2 sealed at housing/interior finish and labeled to indicate . 2.0 cfm leakage at 75 Pa. 403.2.1 Supply ducts in attics are [FR12]1 insulated to >_R-8. All other ducts in unconditioned spaces or outside the building envelope are insulated to 403.2.2 All joints and seams of air ducts, [FR13]i air handlers, filter boxes, and building cavities used as return ducts are sealed. 403.2.3 Building cavities are not used for [FR15]3 supply ducts. U- U- ❑Complies ❑ Does Not ❑ Not Observable ❑Not Applicable See the Envelope Assemblies table for values. Requirement will be met. ❑ Complies ❑Does Not E Not Observable E Not Applicable ❑ Complies ❑Does Not E Not Observable ❑ Not Applicable R- R - R- R - 403.3 HVAC piping conveying fluids R- [FR17]2 above 105 °F or chilled fluids below 55 °F are insulated to 3. 403.4 Circulating service hot water R- [FR18]2 pipes are insulated to R-2. R - ❑ Complies ❑ Does Not [Not Observable ENot Applicable ❑ Complies ❑Does Not ENot Observable ENot Applicable ❑Complies ❑Does Not ['Not Observable ENot Applicable ❑Complies ❑ Does Not E Not Observable ENot Applicable ❑ Complies ❑ Does Not ENot Observable ❑ Not Applicable ❑ Complies ❑Does Not E Not Observable E Not Applicable R - ❑Complies ❑ Does Not ENot Observable ❑ Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Colorado Rocky Mountain School Holden Residences Data filename: 1707 Res Check.rck Report date: 05/02/1 Page 4 of 8 2009 1ECC Framing / Rough -In Inspection 403.5 [FR19I2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Plans Verified Value Field Verified Value Complies? ❑Complies DDoes Not ❑Not Observable ❑Nat Applicable Comments/Assumptions Additional Comments/Assumptions: High Impact (Tier 1) 2 Medium Impact e'Tier 2) 3 Low Impact (Tier 3) Project Title: Colorado Rocky Mountain School Holden Residences Data filename: 1707 Res Check.rck Report date: 05/02/1 Page 5of 8 2009 IECC Insulation Inspection 303.1 All installed insulation is labeled [IN13]1 or the installed R -values provided. 402.1.1, Wall insulation R -value. If this is a 402.2.4, mass wall with at least 1/2 of the 402.2.5 wall insulation on the wall [IN3]1 exterior, the exterior insulation requirement applies. 303.2 Wall insulation is installed per [IN4]1 manufacturer's instructions. Plans Verified Value Field Verified Value R - • Wood ❑ Mass ❑ Steel R- ❑ Wood ❑ Mass ❑ Steel 402.2.11 Sunroom wall insulation has a R- [IN8]1 minimum R -value of R-13. New 4 walls separating the sunroom from conditioned space must meet code requirements. 303.2 Sunroom wall insulation installed [IN9]1 per manufacturer's Instructions. 402.2.11 [IN10]1 ki' Sunroom ceiling minimum insulation R -value of R-19 in Climate Zones 1-4, and R-24 in Climate Zones 5-8. 303.2 Sunroom ceiling insulation is [IN11]1 installed per manufacturer's instructions. R - R - R- Complies? ❑Complies ❑Does Not [Not Observable ❑ Not Applicable Comments/Assumptions ❑ Complies See the Envelope Assemblies ❑ Does Not table for values. ❑ Not Observable ❑ Not Applicable ❑Complies EDoes Not ❑ Not Observable ❑ Not Applicable ❑ Complies ❑ Does Not ❑Not Observable ❑Not Applicable DComplies ❑Does Not ['Not Observable ❑ Not Applicable ❑ Complies ❑Does Not ❑ Not Observable ❑ Not Applicable ❑Complies ❑ Does Not ❑ Not Observable ❑ Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Colorado Rocky Mountain School Holden Residences Data filename: 1707 Res Check.rck Report date: 05/02/1 Page 6 of 8 :2009 IECC Final Inspection Provisions Plans Verified Value Field Verified Value Complies? 402.1.1, Ceiling insulation R -value. Where 402.2.1, > R-30 is required, R-30 can be 402.2.2 used if insulation is not [FRP compressed at eaves. R-30 may be used for 500 ft2 or 20% (whichever is less) where sufficient space is not available. ❑ Wood ❑ Steel R- ❑ Wood ❑ Steel Comments/Assumptions EComplies See the Envelope Assemblies UDoes Not table Tor values. ❑ Not Observable ❑ Not Applicable 303.1.1.1, Ceiling insulation installed per 303.2 manufacturer's instructions. [F12]1 Blown insulation marked every 300 ft2. ❑ Complies ❑ Does Not Not Observable E Not Applicable 402.2.3 Attic access hatch and door [F1311 insulation >_R -value of the adjacent assembly. R- R- EComplies EDoes Not ❑Not Observable ENot Applicable 402.4.2, Building envelope tightness 402.4.2.1 verified by blower door test result [F117]1 of <7 ACH at 50 Pa. This requirement may instead be met via visual inspection, in which case verification may need to occur during Insulation Inspection. ACH 50 = ACH 50 = EComplies E Does Not ['Not Observable ENot Applicable 402.4.3 Wood -burning fireplaces have [F18]2 gasketed doors and outdoor combustion air. EComplies ❑ Does Not ❑ Not Observable E Not Applicable 403.2.2 Post construction duct tightness cfm [F14]1 test result of 58 cfm to outdoors, or 5512 cfm across systems. Or, rough -in test result of 56 cfm across systems or 54 cfm without air handler. Rough -in test verification may need to occur during Framing Inspection. 403.1.1 Programmable thermostats [F19]2 installed on forced air furnaces. 403.1.2 Heat pump thermostat installed [FI10]2 on heat pumps. 403.4 Circulating service hot water [FI11]2 systems have automatic or accessible manual controls. 403.9.1 Readily accessible switch on [F112]3 heaters for swimming pools. 403.9.2 Timer switches on pool heaters [F119]3 and pumps are present. cfm ❑Complies E Does Not ❑ Not Observable ❑ Not Applicable E Complies ❑Does Not ❑ Not Observable ❑ Not Applicable E Complies ❑Does Not [Not Observable E Not Applicable E Complies ❑ Does Not ['Not Observable ENot Applicable EComplies EDoes Not [Not Observable E Not Applicable E Complies EDoes Not ['Not Observable ❑ Not Applicable 1 High Impact (Tier 1) 1 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Colorado Rocky Mountain School Holden Residences Data filename: 1707 Res Check.rck Report date: 05/02/1 Page 7 of 8 2009 IECC Final Inspection Provisions Plans - Verified Value Field Verified Value Complies? Comments/Assumptions 403.9.3 [F120]3 Heated swimming pools have a ❑Complies cover. Covers on pools heated DDoes Not over 90 QF are insulated to R-12. [Not Observable ❑ Not Applicable 404.1 50% of lamps in permanent DComplies [F16], fixtures are high efficacy lamps. DDoes Not ❑Not Observable DNot Applicable 401.3 Compliance certificate posted, [F17)) tti 303.3 Manufacturer manuals for [F118]3 mechanical and water heating equipment have been provided. ❑Complies ❑Does Not ❑ Not Observable ❑ Not Applicable ❑Complies ❑ Does Not ❑ Not Observable ❑Nat Applicable Additional Comments/Assumptions: 1 High Impact Merl) 2 LMedium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Colorado Rocky Mountain School Holden Residences Report date: 05/02/1 Data filename: 1707 Res Check.rck Page 8 of 8 2009 IECC Energy Vt Efficiency Certificate Insulation Rating R -Value Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): 21.00 0.00 49.00 Glass & Door Rating U -Factor SHGC Window Door 0.24 0.37 Heating & Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Comments Date: