From: Dave Argo
Sent: Thursday, May 03, 2018 8:03 AM
To: 'Olivia Emery'
Subject: RE: CRMS Holden Residences ResCheck
Olivia:
Thanks for sending over this RES -Check compliance certificate. This works for not insulating edge of slab at the duplex
residence building, but we'd also like to have a COM -Check analysis for the Health & Counseling Center since it was
reviewed under the 2015 I.B.C. (as a commercial building). I think you will find the COM -Check to be very similar in
nature to RES -Check.
Sorry for the bit of redundancy, but this will be beneficial to have both certificates in our project files.
Dave Argo
Plans Examiner
_ Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Tel: 970-945-8212 Ext. 1610
Email: dargo@garfield-county.com
Web: garfield-county.com
CONFIDENTIALITY NOTICE: This email communication and any files transmitted along with it are intended only for the person or entity to which it is
addressed. If you have received this email in error, please immediately notify the sender by email and delete it from your files.
From: Olivia Emery [mailto:oemery@a4arc.com]
Sent: Wednesday, May 02, 2018 10:09 AM
To: Dave Argo <dargo@garfield-county.com>
Cc: Casey Wilkins <casey@bhgencon.com>; White Joe <jwhite@crms.org>; Faber Brad <brad@bhgencon.com>;
Raaflaub Hans <hans@bhgencon.com>
Subject: CRMS Holden Residences ResCheck
Dave,
Attached is ResCheck for the residences.
I have assigned the slabs a value of 0. Will this suffice to eliminate the foundation rigid at existing foundations
on both projects?
Thank you.
Olivia
A4
A4 Architects LLC
Olivia H. Emery, Principal
242 North Seventh Street
1
LTJ
REScheck Software Version 4.4.4
Compliance Certificate
Project Colorado Rocky Mountain School Holden Residences
Energy Code: 2009 IECC
Location: Carbondale, Colorado
Construction Type: Single-family
Project Type: Alteration
Heating Degree Days. 7313
Climate Zone: 5
Permit Date: 3-9-18
Construction Site:
499 Holden Way
Carbondale, CO 81623
Owner/Agent: Designer/Contractor:
Joe White Olivia Emery
Colorado Rocky Mountain School A4 Architects LLC
499 Holden Way 242 North 7th Street
Carbondale, CO 81623 Carbondale, CO 81623
9709632562 9709636760
jwhite@crms.org oemery@a4arc.com
Compliance: Passes
Maximum UA: 587
Envelope Assemblies
Your UA: 537
Assembly
Gross Area Glazing
Cavitory Cont.
Perimeter or oor
R -Value R -Value U Factor UA
Ceiling 2: Raised or Energy Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame:Double Pane with Low -E
Door 1: Solid
Door 2: Glass
Wall 2: Solid Concrete or Masonry:Interior Insulation
Floor 1: Slab-On-Grade:Unheated
Insulation depth: 0.0'
2,389 49.0 0.0 48
1,926 21.0 0.0 93
199 0.240 48
18 0.360 6
77 0.370 28
690 21.0 0.0 39
264 0.0 275
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in
REScheck Version 4.4.4 and to comply with the mandatory requirement- " " _ _ ,�� _' _ _,- .-ispection Checklist.
Olivia H. Emery, Principal, A4 Architects LLC � ��ll.r�Y' 5.2.18
Name - Title
Signature • Date
Project Title: Colorado Rocky Mountain School Holden Residences Report date: 05/02/1
Data filename: 1707 Res Check.rck Page 1 of 8
LTJ
REScheck Software Version 4.4.4
Inspection Checklist
Requirements: 2.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
2009 IECCI Pre-Inspection/Plan Review
103.2 Construction drawings and
[PR1]1 documentation demonstrate
energy code compliance for the
building envelope.
103.2, Construction drawings and
403.7 documentation demonstrate
[PR3]1 energy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the commercial
code.
Plans Verified
Value
Field Verified
Value
403.6 Heating and cooling equipment is Heating: Heating:
(PR2]2 sized per ACCA Manual 5 based Btu/hr Btu/hr
on loads per ACCA Manual.] or Cooling: Cooling:
other approved methods. Btu/hr Btu/hr
Complies?
❑Complies
❑Does Not
['Not Observable
❑ Not Applicable
❑ Complies
❑ Does Not
❑ Not Observable
❑Not Applicable
Comments/Assumptions
❑Complies
❑Does Not
:Not Observable
❑ Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) J 2
Medium Impact (Tier 2)
3
Low Impact (Tier 3)
Project Title: Colorado Rocky Mountain School Holden Residences Report date: 05/02/1
Data filename: 1707 Res Check.rck Page 2 of 8
2009 IECC
402.1.1
[FO1]1
Foundation Inspection
Plans Verified
Value
Slab edge insulation R -value. R-
❑ Unheated
❑ Heated
303.2,
402.2.8
[FO2]1
Slab edge insulation installed per
manufacturer's instructions.
402.1.1 Slab edge insulation
[FO3]1 depth/length.
Field Verified
Value
R-
❑ Unheated
❑ Heated
303.2.1 A protective covering is installed
[FO11]2 to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
d,
403.8 Snow- and ice -melting system
[FO12]2 controls installed.
ft
Complies?
❑ Complies
E Does Not
❑ Not Observable
❑Not Applicable
❑ Complies
❑Does Not
[Not Observable
❑ Not Applicable
Comments/Assumptions
See the Envelope Assemblies
table for values.
ft ❑Complies
❑ Does Not
❑ Not Observable
❑Not Applicable
❑Complies
Does Not
❑Not Observable
❑ Not Applicable
See the Envelope Assemblies
table for values.
E Complies
❑ Does Not
❑Not Observable
❑ Not Applicable
Additional Comments/Assumptions:
1
High Impact (Tier 1) J 2
Medium Impact (Tier 2)
3
Low Impact (Tier 3)
Project Title: Colorado Rocky Mountain School Holden Residences
Data filename: 1707 Res Check.rck
Report date: 05/02/1
Page 3 of 8
2009 IECC
402.1.1, Door U -factor.
402.3.4
[FRU
402.1.1, Glazing U -factor (area -weighted
402.3.1, average).
402.3.3,
402.5
[FR2]1
303.1.3
[FR4]1
s
FramingPlans Verified Field Verified
/Rough -In Inspection
Value Value
U -factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
Complies?
Comments/Assumptions
U- U- ❑Complies
❑ Does Not
['Not Observable
❑ Not Applicable
See the Envelope Assemblies
table for values.
U- U- ❑Complies
Does Not
E Not Observable
E Not Applicable
402.3.5 Sunrooms enclosing conditioned U-
[FR8]1 space have a maximum
fenestration U -factor of 0.50 in
Climate Zones 4-8. New glazing
separating the sunroom from
conditioned space must meet
code requirements.
402.3.5 Sunrooms enclosing conditioned U
[FR9]' space have a maximum skylight
U -factor of 0.75 in Climate Zones
4-8.
402.4.4 Fenestration that is not site built
[FR2O]1 is listed and labeled as meeting
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
402.4.5 IC -rated recessed lighting fixtures
[FR16]2 sealed at housing/interior finish
and labeled to indicate . 2.0 cfm
leakage at 75 Pa.
403.2.1 Supply ducts in attics are
[FR12]1 insulated to >_R-8. All other ducts
in unconditioned spaces or
outside the building envelope are
insulated to
403.2.2 All joints and seams of air ducts,
[FR13]i air handlers, filter boxes, and
building cavities used as return
ducts are sealed.
403.2.3 Building cavities are not used for
[FR15]3 supply ducts.
U-
U-
❑Complies
❑ Does Not
❑ Not Observable
❑Not Applicable
See the Envelope Assemblies
table for values.
Requirement will be met.
❑ Complies
❑Does Not
E Not Observable
E Not Applicable
❑ Complies
❑Does Not
E Not Observable
❑ Not Applicable
R-
R -
R-
R -
403.3 HVAC piping conveying fluids R-
[FR17]2 above 105 °F or chilled fluids
below 55 °F are insulated to
3.
403.4 Circulating service hot water R-
[FR18]2 pipes are insulated to R-2.
R -
❑ Complies
❑ Does Not
[Not Observable
ENot Applicable
❑ Complies
❑Does Not
ENot Observable
ENot Applicable
❑Complies
❑Does Not
['Not Observable
ENot Applicable
❑Complies
❑ Does Not
E Not Observable
ENot Applicable
❑ Complies
❑ Does Not
ENot Observable
❑ Not Applicable
❑ Complies
❑Does Not
E Not Observable
E Not Applicable
R -
❑Complies
❑ Does Not
ENot Observable
❑ Not Applicable
1
High Impact (Tier 1)
2
Medium Impact (Tier 2)
3 1 Low Impact (Tier 3)
Project Title: Colorado Rocky Mountain School Holden Residences
Data filename: 1707 Res Check.rck
Report date: 05/02/1
Page 4 of 8
2009 1ECC Framing / Rough -In Inspection
403.5
[FR19I2
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
Plans Verified
Value
Field Verified
Value
Complies?
❑Complies
DDoes Not
❑Not Observable
❑Nat Applicable
Comments/Assumptions
Additional Comments/Assumptions:
High Impact (Tier 1)
2
Medium Impact e'Tier 2)
3
Low Impact (Tier 3)
Project Title: Colorado Rocky Mountain School Holden Residences
Data filename: 1707 Res Check.rck
Report date: 05/02/1
Page 5of 8
2009 IECC
Insulation Inspection
303.1 All installed insulation is labeled
[IN13]1 or the installed R -values
provided.
402.1.1, Wall insulation R -value. If this is a
402.2.4, mass wall with at least 1/2 of the
402.2.5 wall insulation on the wall
[IN3]1 exterior, the exterior insulation
requirement applies.
303.2 Wall insulation is installed per
[IN4]1 manufacturer's instructions.
Plans Verified
Value
Field Verified
Value
R -
• Wood
❑ Mass
❑ Steel
R-
❑ Wood
❑ Mass
❑ Steel
402.2.11 Sunroom wall insulation has a R-
[IN8]1 minimum R -value of R-13. New
4 walls separating the sunroom
from conditioned space must
meet code requirements.
303.2 Sunroom wall insulation installed
[IN9]1 per manufacturer's Instructions.
402.2.11
[IN10]1
ki'
Sunroom ceiling minimum
insulation R -value of R-19 in
Climate Zones 1-4, and R-24 in
Climate Zones 5-8.
303.2 Sunroom ceiling insulation is
[IN11]1 installed per manufacturer's
instructions.
R -
R -
R-
Complies?
❑Complies
❑Does Not
[Not Observable
❑ Not Applicable
Comments/Assumptions
❑ Complies See the Envelope Assemblies
❑ Does Not table for values.
❑ Not Observable
❑ Not Applicable
❑Complies
EDoes Not
❑ Not Observable
❑ Not Applicable
❑ Complies
❑ Does Not
❑Not Observable
❑Not Applicable
DComplies
❑Does Not
['Not Observable
❑ Not Applicable
❑ Complies
❑Does Not
❑ Not Observable
❑ Not Applicable
❑Complies
❑ Does Not
❑ Not Observable
❑ Not Applicable
Additional Comments/Assumptions:
1
High Impact (Tier 1)
2 'Medium Impact (Tier 2)
3
Low Impact (Tier 3)
Project Title: Colorado Rocky Mountain School Holden Residences
Data filename: 1707 Res Check.rck
Report date: 05/02/1
Page 6 of 8
:2009 IECC
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
402.1.1, Ceiling insulation R -value. Where
402.2.1, > R-30 is required, R-30 can be
402.2.2 used if insulation is not
[FRP compressed at eaves. R-30 may
be used for 500 ft2 or 20%
(whichever is less) where
sufficient space is not available.
❑ Wood
❑ Steel
R-
❑ Wood
❑ Steel
Comments/Assumptions
EComplies See the Envelope Assemblies
UDoes Not table Tor values.
❑ Not Observable
❑ Not Applicable
303.1.1.1, Ceiling insulation installed per
303.2 manufacturer's instructions.
[F12]1 Blown insulation marked every
300 ft2.
❑ Complies
❑ Does Not
Not Observable
E Not Applicable
402.2.3 Attic access hatch and door
[F1311 insulation >_R -value of the
adjacent assembly.
R- R- EComplies
EDoes Not
❑Not Observable
ENot Applicable
402.4.2, Building envelope tightness
402.4.2.1 verified by blower door test result
[F117]1 of <7 ACH at 50 Pa. This
requirement may instead be met
via visual inspection, in which
case verification may need to
occur during Insulation
Inspection.
ACH 50 = ACH 50 = EComplies
E Does Not
['Not Observable
ENot Applicable
402.4.3 Wood -burning fireplaces have
[F18]2 gasketed doors and outdoor
combustion air.
EComplies
❑ Does Not
❑ Not Observable
E Not Applicable
403.2.2 Post construction duct tightness cfm
[F14]1 test result of 58 cfm to outdoors,
or 5512 cfm across systems. Or,
rough -in test result of 56 cfm
across systems or 54 cfm
without air handler. Rough -in test
verification may need to occur
during Framing Inspection.
403.1.1 Programmable thermostats
[F19]2 installed on forced air furnaces.
403.1.2 Heat pump thermostat installed
[FI10]2 on heat pumps.
403.4 Circulating service hot water
[FI11]2 systems have automatic or
accessible manual controls.
403.9.1 Readily accessible switch on
[F112]3 heaters for swimming pools.
403.9.2 Timer switches on pool heaters
[F119]3 and pumps are present.
cfm
❑Complies
E Does Not
❑ Not Observable
❑ Not Applicable
E Complies
❑Does Not
❑ Not Observable
❑ Not Applicable
E Complies
❑Does Not
[Not Observable
E Not Applicable
E Complies
❑ Does Not
['Not Observable
ENot Applicable
EComplies
EDoes Not
[Not Observable
E Not Applicable
E Complies
EDoes Not
['Not Observable
❑ Not Applicable
1
High Impact (Tier 1) 1 2
Medium Impact (Tier 2)
3 1 Low Impact (Tier 3)
Project Title: Colorado Rocky Mountain School Holden Residences
Data filename: 1707 Res Check.rck
Report date: 05/02/1
Page 7 of 8
2009 IECC
Final Inspection Provisions
Plans - Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
403.9.3
[F120]3
Heated swimming pools have a ❑Complies
cover. Covers on pools heated DDoes Not
over 90 QF are insulated to R-12. [Not Observable
❑ Not Applicable
404.1 50% of lamps in permanent DComplies
[F16], fixtures are high efficacy lamps. DDoes Not
❑Not Observable
DNot Applicable
401.3 Compliance certificate posted,
[F17))
tti
303.3 Manufacturer manuals for
[F118]3 mechanical and water heating
equipment have been provided.
❑Complies
❑Does Not
❑ Not Observable
❑ Not Applicable
❑Complies
❑ Does Not
❑ Not Observable
❑Nat Applicable
Additional Comments/Assumptions:
1 High Impact Merl)
2 LMedium Impact (Tier 2)
3
Low Impact (Tier 3)
Project Title: Colorado Rocky Mountain School Holden Residences Report date: 05/02/1
Data filename: 1707 Res Check.rck Page 8 of 8
2009 IECC Energy
Vt Efficiency Certificate
Insulation Rating
R -Value
Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
21.00
0.00
49.00
Glass & Door Rating
U -Factor SHGC
Window
Door
0.24
0.37
Heating & Cooling Equipment
Efficiency
Heating System:
Cooling System:
Water Heater:
Name:
Comments
Date: