Loading...
HomeMy WebLinkAboutConstruction Details & SpecsL-� Garfield County Building Dept 108 8th Street Suite 401 Carbondale, CO 81601 970-945-8212 Project Description; Dollar General Date. Monday, 30 ,Jul 2018 Project Location: Construction by: Architect: MIIIIn Engineer: Smith Code Study by: This code study is based on the 2015 International Building Code by ICC using Plan Analyst. www.plananalyst.com BASIC BUILDING DESCRIPTION: Type of Construction = IIB Building does not have an automatic sprinkler system Allowable area and height based on different uses not being separated by fire barriers. Most restrictive height and area used. (508.3.2) ADDRESS IDENTIFICATION: Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Characters shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out Each character shall be not less than 4 inches high and not less than 0.5 inch wide. They shall be installed an a contrasting background. When required by the fire official, address numbers shall be provided in additional approved locations When access is by a private road and the building address cannot be view from the public way, a monument, pole or other approved sign shall be used to identify the structure. (501.2) SITE DESCRIPTION: (506.3.2 and 202 FIRE SEPARATION DISTANCE) The north side has a lot line. Distance to lot line = 170.0 Length of perimeter facing lot line = 130.0 This side is not accessible from a street or approved fire lane. The east side has a lot line. Distance to lot line = 15.0 Length of perimeter facing lot line = 70.0 This side is not accessible from a street or approved fire lane. The south side has a lot line. Distance to lot line = 95.0 Length of perimeter facing lot line = 130.0 This side can be accessed from a street or approved fire lane. The west side has a lot line. Distance to lot line = 60.0 Length of perimeter facing lot line = 70.0 This side can be accessed from a street or approved fire lane. Perimeter of the entire building = 400.0 feet. Perimeter which fronts a public way or accessible open space = 200.0 feet. Weighted average of the width of public way or accessible open space = 30.0 feet. (506.3.2) Allowable area increased 25.00% due to frontage. (506.3) HEIGHT OF BUILDING: Actual height of building = 19 ft. Allowed building height = 55.00 ft BUILDING INTERIOR: ALLOWABLE AREA AND HEIGHT: FL NAME OCC MAX FLR AREA ALLOWED RATIO STATUS F1 Sales area M 2 7263 15625 0.46 OK F1 Storage area S1 2 1111 15625 0.07 OK F1 Business area B 3 350 15625 0.02 OK TOTAL FOR FLOOR 8724 15625 0.56 OK BUILDING TOTAL 8724 15625 0.56 OK Notes: Allowable area is based on Table 506.2 and Section 506. Allowable number of stories is based on Table 504.4 and Section 504 Allowed area increased 25% for frontage increase. (506.3) iY e'1,k. EXIT REQUIREMENTS: 67D NAME NUMB MIN MIN CORRIDOR MAX OF OF NUMB EXIT " NIC DOOR FIRE TRVL FL AREA OCC EXIT WDT HDWR SWNG RATING DIST NOTES Fl Sales area 242 (J 48.4 no �T N/A 200 1 18 Fl Storage area 4 1 no any N/A 200 F1 (A)Business area 4 1 .7 no any N/A 200 TOTAL 1st FLOOR 246 2 49.2 no OUT N/A 200 5 NOTE: Areas with (A) before the number of occupants is being treated an accessory use area. This area is only used persons who occupy the main areas of the building. The occupant load of this area is not included in the total occupant load for suites, floors, or the building. FOOTNOTES: 1. Two exits are required from this area since the occupant load exceeds allowable in Table 1006.2.1 5. Number of exits from this floor is based on Section 1006.3.2 18. A required exit from the sales area may not pass through a storage area. (1016.2 #5, See exceptions) NOTES FOR EXIT TABLE: Door swing is based on Section 1010.1.2 Occupant load is based on Section 1004 and Table 1004.1.2 Exit width is in inches and based on Sections 1005.3.1 and 1005.3.2 For the minimum width of stairways, see Section 1011.2. Exits shall be continuous from the point of entry into the exit to the exit discharge. (1003.6) EXIT WIDTH NOTES: Exit width is in inches and based on Section 1005.2 EGRESS CONTINUITY: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component. (1003.6) EXIT SEPARATION: In areas where 2 exits are required, the minimum separation is 1/2 of the maximum diagonal of the Kea 44 fT or floor measured in a straight line between exits or exit access doorways. (1007.1.1) R 14 . Exception 1: Where interior exit stairways are interconnected by a 1 -hour corridor, the separation shall be g ©, it/ measured along the shortest direct travel within the corridor. Multiple means of egress shall be sized such that the loss of any one means of egress shall not reduce the available capacity by more than 50 percent. (1005.5) MEANS OF EGRESS ILLUMINATION: 1. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. (1006.1) 2. The means of egress illumination shall not be less than 1 foot-candle at the walking surface level. (1006.2) See section 1006.3 for emergency power requirements. LANDINGS AT DOORS: 1. There shall be a floor or landing on each side of a door. (1010.1.5) 2. Such floor or landing shall be at the same elevation on each side of the door. (1010.1.5) 3. The floor or landing shall not be more than 1/2 inch lower than the threshold. (1010.1.7) 4. Landings shall have a width not less than the width of the stairway or width of the doorway, whichever is the greater. Where a landing serves an occupant load of 50 or more, doors in any position shall not reduce the landing dimension to less than one half of the required width. The minimum length in the direction of exit travel is 44 inches. (1010.1.6) 5 The spare hetween two doors In series shall be 48 inches plus the width of door swinging into the space. (1010 1.8) BOLT LOCKS: Manually operated flush bolts and surface bolts are not permitted. (1010.1.9.4) Exception 2: Where a pair of doors serves a storage or equipment room, manually operated edge- or surface -mounted bolts are permitted on the inactive leaf. The unlatching of any door or leaf shall not require more than one operation. (1010.1.9.5) Exception 2: Where manually operated bolt locks are permitted. Exception 3: Doors with automatic flush bolts as permitted. LOCKS AND LATCHES: Egress doors shall be readily openable from the egress side without the use of a key or any special knowledge or effort. (1010.1.9) Locks and latches shall be permitted to prevent operation where any of the following exists: (1010.1.9.3) 2. The main door or doors in Group B, F, M and S areas are permitted to be equipped with key operating locking devices from the egress side provided: 2.1 The locking device is readily distinguishable as locked. 2.2 A readily visible durable sign is posted on the egress side stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING 1S OCCUPIED 3. Where egress doors are used in pairs, automatic flush bolts shall be permitted to be used, provided the door leaf having the automatic flush bolts has no doorknob or surface -mounted hardware. 5. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism. BUILDING ACCESSIBILITY: Accessible entrances and accessiblilty within the building shall comply with Sections 1104 and 1105. On floors where drinking fountains are provided, accessible drinking fountains shall be provided. No fewer than 2 drinking fountains shall be provided. One shall comply with the requirements for people in a wheelchair and one for standing persons. (1109.5.1) MINIMUM NUMBER OF PLUMBING FIXTURES: (2902.1) FL NAME OF AREA NUMBER WATER CLOSETS LAVATORIES DRINKING OCC MALE FEMALE MALE FEMALE FOUNTAINS F1 Sales area F1 Storage area Fl (A)Business area TOTAL for 1st FLOOR 242 4 4 246 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 NOTES ON THE TOTAL NUMBER OF PLUMBING FIXTURES: The number of fixtures for a floor may not match total number of fixtures per area. 1. Fixtures for accessory areas are not included in the floor total. 2. The number of fixtures for each area are rounded up to the next whole number. Floor totals are not rounded up until the floor total is obtained. If the fixtures only serve an area, use number shown for each area. If the fixtures serve an entire floor, use number shown for totals. FIRE -RESISTANCE REQUIREMENTS: FIRE -RESISTANCE RATING FOR EXTERIOR WALLS: North Side: Group M - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705 8) Group S1 - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705 5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There Is no limit on protected openings. (Table 705.8) Group B - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) If there are projections beyond the exterior wall, they shall be of noncombustible materials. (705.2.1) See Section 1406.3 for balconies. East Side: Group M - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) Group S1 - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) Group B - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) If there are projections beyond the exterior wall, they shall be of noncombustible materials. (705.2.1) See Section 1406.3 for balconies. South Side: Group M - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) Group S1 - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) Group B - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) If there are projections beyond the exterior wall, they shall be of noncombustible materials. (705.2.1) See Section 1406.3 for balconies. West Side: Group M - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) Group S1 - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) Group B - Bearing walls = 0 -hr Nonbearing walls = 0 -hr rating on the inside. (705.5, Tables 601 & 602) Parapet not required. (705.11, Exception 3) Projections extending beyond the exterior wall are not permitted. (Table 705.2) No limit on unprotected openings. There is no limit on protected openings. (Table 705.8) If there are projections beyond the exterior wall, they shall be of noncombustible materials. (705.2.1) See Section 1406.3 for balconies. FIRE -RESISTANCE RATING REQUIREMENTS:(Table 601 except as noted) Exterior walls . Minimum fire resistance rating = FIRE -RESISTANCE RATING FOR EXTERIOR WALLS above Primary structural frame must be noncombustible. Minimum fire resistance rating = 0 hour Interior bearing wall must be noncombustible. Minimum fire resistance rating = 0 hour Interior nonbearing wall must be noncombustible. Minimum fire resistance rating = 0 hour Fire -retardant treated wood shall be permitted in: (603.1) 1.1 Nonbearing partitions where the required fire -resistance rating is two hours or less. 1.2 Nonbearing exterior walls where no fire rating is required. 1.3 Roof construction, including girders, trusses, framing and decking. Partitions dividing portions of stores, offices or similar places occupied by one tenant only and do not establish a corridor or serve an occupant load of 30 or more may be: 1. constructed of fire retardant treated wood 2. one hour fire resistive construction 3. wood panels or similar up to six feet in height. (603.1, 10) Floor/ceiling assembly must be noncombustible. Minimum fire resistance rating = 0 hour Roof/ceiling assembly must be noncombustible. Minimum fire resistance rating = 0 hour Fire -retardant -treated wood shall be allowed in buildings including girders and trusses as part of the roof construction. (Table 601, b.) Stairs must be noncombustible. Minimum fire resistance rating = 0 hour REQUIRED SEPARATION OF OCCUPANCIES: (508.4.4 & Table 508.4) Uses are not separated by fire barriers. The construction of the building is based on the most restrictive use. (508.3.3) SEPARATION OF INCIDENTAL USE AREAS: (Table 509) Furnace rooms where any piece of equipment is over 400,000 BTU per hour input = 1 hour Rooms with any boiler over 15 psi and 10 horsepower = 1 hour Refrigerant machinery rooms = 1 hour Hydrogen cut-off rooms not classified as Group H = 1 hour Incinerator rooms = 2 hours and an automatic sprinkler system is required Stationary storage battery systems having a liquid capacity of more than 50 gallons of flooded lead -acid, nickel cadmium or VRLA or more than 1,000 pounds for lithium -ion and lithium medal polymer used for facility standby power, emergency power or uninterrupted power supplies = 1 hour SMOKE AND HEAT REMOVAL: Areas containing high piled combustible combustible storage require smoke and heat removal when required by Table 3206.2 of the IFC. Design to comply with Section 910.3. ROOFING REQUIREMENTS: 1. The roofing on this building is required to be Class C or better. (Table 1505.1) ROOF DRAINAGE: Where the exterior wall construction extends above the roof in such a manner that water will be entrapped if the primary drains allow build up for any reason,secondary (emergency overflow) roof drains or scuppers shall be provided. (1503.4.1) 1. Secondary drains or scuppers shall be located and sized to prevent the weight ponding water from exceeding the design load of the roof. 2. See section 1611.1 for design load requirements. 3. Scuppers shall not have an opening dimension of less than 4 inches. (1503.4.2 4. See sections 1106 and 1108 of the Plumbing code for design requirements. When there is an occupied floor more than 120 feet above fire department vehicle access, no fewer than two fire service access elevators or all elevators, whichever is less, shall be provided. (403.6.1) See Section 3007 for requirements. Each fire service access elevator shall have a capacity of not less than 3500 pounds.(403 6.1) 400 h7 AUTOMATIC SPRINKLER SYSTEMS: �5,r If openings are not provided in each 50 feet on at least one exterior wall or there is floor area more than 75 feet from an exterior opening, an automatic sprinkler system is requiieU. Openings shall have a r1' G 3 ; minimum dimension of 3(1 inches There must be at least 20 sq.ft. of opening in every 50 lineal feet of wall c,,FG' 0 or fraction thereof. The height of the bottom of the opening shall not exceed 44 inches measured from they. floor. (903.2.11.1) An automatic sprinkler system is required where a fire area exceeds 5,000 square feet and the area is h I used for display and sale of upholstered furniture or matresses. (903.2.7, #4) its r,,� .] An automatic sprinkler system shall be provided in accordance with the IFC in all buildings of Group M where storage of merchandise is in high-piled or rack storage arrays. (903.2.7.1) An automatic sprinkler system shall be provided when the area exceeds 2,500 square feet and is used for.id the storage of upholstered furniture or mattresses. (903.2.9 #5) Note: The size of the fire area may be reduced using fire barriers. See section 707.3.10 for requirements. The fire-resistive rating for the fire barier assembly is 3 hours. (Table 707.3.10) PORTABLE FIRE EXTINGUISHERS: Portable fire extinguishers are required. (906.1) See Section 906.1 and Table 906.1 for location requirements. See Section 906.3 for size and distribution requirements. SMOKE AND HEAT REMOVAL: Areas containing high piled combustible combustible storage require smoke and heat removal when required by Table 3206.2 of the IFC. Design to comply with Section 910.3. ACCESSIBLE FACILITIES: Accessible water fountains shall comply with ICC/ANSI A117.1, see Section 602. Toilet facilities shall comply with ICC/ANSI A117.1, see Sections 603 through 609. ADDITIONAL TOILET REQUIREMENTS: Customers, patrons and visitors shall be provided with public toilet facilities in spaces intended for public utilization. (2902.3) The route to the public facilities shall not pass through kitchens, storage rooms or closets. (2902.3.1) The path of travel to facilities shall not exceed a distance of 500 feet. (2902.3.2) Directional signage indicating route to public facilities shall be posted. Such signage shall be located in a corridor or aisle at the entrance to the facilities. (2902.4.1) Where a toilet is provided for use of multiple occupants, the egress door for the room shall not be lockable from the inside. (2902.3.5) Where a building or tenant space requires a separate toilet facility for each sex and each toilet facility is required to have only one water closet, two family/assisted-use toilet facilities shall be permitted to serve as required separate facilities Toilet facilities shall not be required to be identified for exclusive use by either sex. (2902.2.1) LIGHT AND VENTILATION: 1. Every space intended for human occupancy shall be provided with natural light by means of exterior glazed openings or shall be provided with artificial light. (1205.1) 2. Buildings shall be provided with natural ventilation or mechanical ventilation per the International Mechanical Code. (1203.1) 3. Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanically ventilated. (1203.5.2.1) GLAZING REQUIREMENTS: All glazing in hazardous locations is required to be of safety glazing material. (2406.1) See Section 2406.4 for locations. WALL AND CEILING FINISHES: 1. Wall and ceiling finish materials are required to comply with Sec. 803.11 and Table 803.11. 2. Textile wall and ceiling coverings shall have Class A flame spread index and shall be protected by automatic sprinklers ur meet the criteria in Section 803.5, 803.6. 3. Expanded vinyl wall coverings shall comply with the requirements for textile wall and ceiling materials. (803.7) 4. Toilet room floors shall have a smooth, hard nonabsorbent surface that extends upward onto the walls at least 4 inches. (1210.2.1 5. Walls within 2 feet of urinals and water closets shall have a smooth, hard nonabsorbent surface, to a height of 4 feet above the floor. (1210.2.2) CEILING HEIGHTS: Occupiable spaces, habitable spaces and corridors shall have a ceiling height of not less than 7 feet 6 inches. Bathrooms, toilet rooms, kitchens, storage rooms and laundry rooms shall be permitted to have a ceiling height of not less than 7 feet. (1208.2) INSULATION NOTES: 1. Insulating materials shall have a flame -spread rating of no more than 25 and a smoke developed index of not more than 450. (720.2) 'concealed installation' and Sec. 720.3 'exposed installation' Foam plastic insulations are required to be protected. (2603) 2 1.10 GOXE 1 A - SERVICE COUNTER PLAN Ll B - ELEVATION Ink ---FAIZAllirniMiliriale:6,1"EniMPEWrr f It II II II II f 1I jj 1f = 11 _.11 II 110 11 1I II II 11 ,11 11 11 11 11 11 I1 11 11 • 11 11 - -�� I1 1I iI it I 11 f it II F I; II; 11 jj__jj4 II 11 11 II 1 11 11 II 11 ilk.�1I 11 11 II 11 II f 11 11 IF 11 11 ill II 11 if 1t 1 11 11 11 11 11 11 1 11 11 11 1 11 ,111 11 11 II 11 II 11 _11! 11 ,11 FIXTURE PLAN SCALE: L5/I W=I DSI PLAID NORTH I NOTE FRONT CHECKOUT COUNTER TO BE PROVIDED BY DOLLAR GENERAL AND INSTALLED AT DOLLAR GENERALS DIRECTION. COUNTERS SHALL INCLUDE A PORTION OF AT LEAST 30" IN LENGTH WHICH IS NO MORE THEN 34" ABOVE THE FINISH FLOOR COUNTERS SHALL BE ON AN ACCESSIBLE ROUTE. CHECK WRITING SURFACE SERVICE COUNTER DETAILS SCALA ,Dy.,• -S( 3 -1-6 / 6 /Z - / gD I )tz'7 64 W4 erie Cc 761 FOR APPROVAL THIS DRAWING AND THE INFORMATION SHOWN THEREON IS THE PROPERTY OF MIWN ENTERPRISES. INC. IT SHALL NOT BE COPIED OR DUPLICATED IN ANY MANNER ANB SHALL NOT li sUBMTITEO TO ANY OUTSIDE MIT OR LI R AS A BASIS FOR DESIGN TAWICAJT WAIMEA COKSENT. 1 1 1 L z cii E-+ z z 225-291-2057 225-274-1620 5- LA � AG L.3 �a 1630 _ O FO MA. PR REVISIONS: n 07,30. 18 n n DRAWN BY: CHECKED BY: T.M LANDLORD: PERMIT: ISSUE IHTE 02,1)6/18 JOB NO: 00-000 SHEET: F 1 3 of 21 PENDING APPROVALS PENDING APPROVALS