HomeMy WebLinkAboutPlansiSHEEr61 1 �T7 5 I 1 SFEET 8 ` I Iaj$T 4 I I 1 SFr a , II \ SHEET z SHEET LAYOUT II II II II II II 1 I / 0 CIRCLE B LAND LAYDOWN YARD -SITE PLAN SE114SW%4 SECTION SOUTH,�ST, 6TH P.M. COUNy�ARF LD, ATE OFCOLpADp APPROVED SUBJECT TO NOTED EXCEPTIONS & INSPECTIONS GARFIELD COUNTY BUILDJNQ DEP WENT DATE 4 I6 BY . FIELD COPY NO INSPECTION WITHOUT THESE PLANS ON SITE Page Of _ SMITH CIRCLE B LAND �— 11 I � I I- w P.O.B. e^ d / / / TIE TO SOUTHWEST RIM CORNER SECTION 23: / N 88'46'31" W, 1995.93' 1973 BRASS CAP .44 I / El III ------------ -- SECTION 23 .. __.. ,. ... �., QPCTION 9.9 I I II I I I I I GRAVEL ROAD II II PARENT PARCEL LEGAL DESCRIPTION-' THE SE%4SW/4, SECTION 23, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE 6TH P.M., GARFIELD COUNTY, COLORADO SITE LEGAL DESCRIPTION: A LAYDOWN YARD SITE SITUATED IN THE SEl/4SW%4, SECTION 23, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE 6TH P.M., GARFIELD COUNTY, COLORADO, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID LAYDOWN YARD SITE, WHENCE THE SOUTHWEST CORNER OF SAID SECTION 23 BEARS N 8846'31 " WA DISTANCE OF 1995.93 FEET, THENCE FOLLOWING THE PERIMETER OF SAID STORAGE YARD SITE N 06°21'08" WA DISTANCE OF 478.37 FEET, THENCE N 35003'48" WA DISTANCE OF 263.09 FEET THENCE N 0501742" WA DISTANCE OF 64.53 FEET THENCE N 31'4826" E A DISTANCE OF 209.42 FEET; THENCE N 7801110" E A DISTANCE OF 186.65 FEET; THENCE S 06°21'08" E A DISTANCE OF 895.57 FEET, • THENCE S 41 001'25" E A DISTANCE OF 114.85 FEET THENCE N 88-46'31 " WA DISTANCE OF 257.58 FEET TO THE POINT OF BEGINNING. PROPOSED SITE CONTAINS 5.00 ACRES± BEARINGS BASED ON NAD83, COLORADO STATE PLANE, CENTRAL ZONE NOTES 1.) DATE OF SURVEY: JUNE, 2013. 2.) THIS MAP WAS PREPARED WITHOUT THE BENEFIT OF A CURRENT TITLE COMMITMENT AND DOES NOT REPRESENT A TITLE SEARCH BY THIS SURVEYOR OR ECLIPSE SURVEYING, INC. OF THE PROPERTY SHOWN TO DETERMINE OWNERSHIP, COMPATIBILITY WITH ADJOINING PARCELS, OR EASEMENT OR ENCUMBRANCES OF RECORDS AFFECTING THIS PARCEL. 3.) THE EXISTING GRAVELED AREA IS NOT LOCATED WITHIN A 30% SLOPE AREA. 4.) THE SHADED (SOLID) AREAS ILLUSTRATED HEREIN REPRESENT THE COMPUTER GENERATED ANALYSIS FOR SLOPES OF 20% AND GREATER. 5.) THIS SITE PLAN DOES NOT REPRESENT A BOUNDARY, IMPROVEMENT OR w • IMPROVEMENT LOCATION CERTIFICATE SURVEY BY ECLIPSE SURVEYING, INC. J 6.) APPROXIMATE ELEVATION OF THE SITE IS 5920', BASED ON WGS 84 DATUM GPS OBSERVATION. 7.) CONTOUR INTERVAL IS 2 FEET. 8.) SITE IS LOCATED IN THE GARFIELD COUNTY RURAL ZONE DISTRICT 9.) ALL IMPROVEMENTS SHOWN ARE EXISTING ,V\ 10.) EXISTING BARN IS NOT TO BE USED FOR STORAGE SURVEYOR'S STATEMENT 1, JAMES A. KALMON, A REGISTERED LAND SURVEYOR, LICENSED UNDER THE LAWS OF THE STATE OF COLORADO DO HEREBY CERTIFY THAT THE SURVEY SHOWN HEREON WAS PREPARED ON THIS DATE: JUNE 17, 2013 BY ME OR UNDER MY DIRECT SUPERVISION AND CHECKING AND THAT THIS MAP IS A TRUE ��.. REPRESENTATION THEREOF. JAMES A KALMON, COLORADO REGISTRATION NO. 38050 FOR AND ON BEHALF OF ECLIPSE SURVEYING, INC. GRAPHIC SCALE CT3 o G v mC-3 J --i RESIDENCE � DFT. N CK. / - Existing bam to be demolished Demo permit # DEMO -06-17-4796 208' III New building to be place where existing bam is located. CIRCLE B LAYDOWN YARD 39.507322 N LAT: LONG: 107.636664 W I Zn l \ I Approximate location of new \ �s \ \ I \ budd&�g placement I �s 61 \ (D CCI I CC) ,L ��\ EXISTING \ \\ r I I I GRAVELED AREA cc SIX LAZY K ROAD \\\ OVERHEAD \ \ o 1\ \\ / / ELECTRIC \� N 0 1 CIRCLE B LAND FOWLER \� S 41'01'25" E, 114.85' I- w P.O.B. e^ d / / / TIE TO SOUTHWEST RIM CORNER SECTION 23: / N 88'46'31" W, 1995.93' 1973 BRASS CAP .44 I / El III ------------ -- SECTION 23 .. __.. ,. ... �., QPCTION 9.9 I I II I I I I I GRAVEL ROAD II II PARENT PARCEL LEGAL DESCRIPTION-' THE SE%4SW/4, SECTION 23, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE 6TH P.M., GARFIELD COUNTY, COLORADO SITE LEGAL DESCRIPTION: A LAYDOWN YARD SITE SITUATED IN THE SEl/4SW%4, SECTION 23, TOWNSHIP 6 SOUTH, RANGE 92 WEST OF THE 6TH P.M., GARFIELD COUNTY, COLORADO, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF SAID LAYDOWN YARD SITE, WHENCE THE SOUTHWEST CORNER OF SAID SECTION 23 BEARS N 8846'31 " WA DISTANCE OF 1995.93 FEET, THENCE FOLLOWING THE PERIMETER OF SAID STORAGE YARD SITE N 06°21'08" WA DISTANCE OF 478.37 FEET, THENCE N 35003'48" WA DISTANCE OF 263.09 FEET THENCE N 0501742" WA DISTANCE OF 64.53 FEET THENCE N 31'4826" E A DISTANCE OF 209.42 FEET; THENCE N 7801110" E A DISTANCE OF 186.65 FEET; THENCE S 06°21'08" E A DISTANCE OF 895.57 FEET, • THENCE S 41 001'25" E A DISTANCE OF 114.85 FEET THENCE N 88-46'31 " WA DISTANCE OF 257.58 FEET TO THE POINT OF BEGINNING. PROPOSED SITE CONTAINS 5.00 ACRES± BEARINGS BASED ON NAD83, COLORADO STATE PLANE, CENTRAL ZONE NOTES 1.) DATE OF SURVEY: JUNE, 2013. 2.) THIS MAP WAS PREPARED WITHOUT THE BENEFIT OF A CURRENT TITLE COMMITMENT AND DOES NOT REPRESENT A TITLE SEARCH BY THIS SURVEYOR OR ECLIPSE SURVEYING, INC. OF THE PROPERTY SHOWN TO DETERMINE OWNERSHIP, COMPATIBILITY WITH ADJOINING PARCELS, OR EASEMENT OR ENCUMBRANCES OF RECORDS AFFECTING THIS PARCEL. 3.) THE EXISTING GRAVELED AREA IS NOT LOCATED WITHIN A 30% SLOPE AREA. 4.) THE SHADED (SOLID) AREAS ILLUSTRATED HEREIN REPRESENT THE COMPUTER GENERATED ANALYSIS FOR SLOPES OF 20% AND GREATER. 5.) THIS SITE PLAN DOES NOT REPRESENT A BOUNDARY, IMPROVEMENT OR w • IMPROVEMENT LOCATION CERTIFICATE SURVEY BY ECLIPSE SURVEYING, INC. J 6.) APPROXIMATE ELEVATION OF THE SITE IS 5920', BASED ON WGS 84 DATUM GPS OBSERVATION. 7.) CONTOUR INTERVAL IS 2 FEET. 8.) SITE IS LOCATED IN THE GARFIELD COUNTY RURAL ZONE DISTRICT 9.) ALL IMPROVEMENTS SHOWN ARE EXISTING ,V\ 10.) EXISTING BARN IS NOT TO BE USED FOR STORAGE SURVEYOR'S STATEMENT 1, JAMES A. KALMON, A REGISTERED LAND SURVEYOR, LICENSED UNDER THE LAWS OF THE STATE OF COLORADO DO HEREBY CERTIFY THAT THE SURVEY SHOWN HEREON WAS PREPARED ON THIS DATE: JUNE 17, 2013 BY ME OR UNDER MY DIRECT SUPERVISION AND CHECKING AND THAT THIS MAP IS A TRUE ��.. REPRESENTATION THEREOF. JAMES A KALMON, COLORADO REGISTRATION NO. 38050 FOR AND ON BEHALF OF ECLIPSE SURVEYING, INC. GRAPHIC SCALE CT3 o G v mC-3 J C/7 M � C3 m Oi FILE: C m � DFT. N CK. O� W N O N QCO00 �WO M tr M:> Z mW 0000C J 0 m r d ROF 6/14/ C3 JECT d LAY C L �+ SH 68'0"010 CONCRETEAND STEEL 2 3 22'9" 278" 278" 4" 22'4" 224" 8" / CENTERFOOT/NGSON REINFORCED CONCRETE NOTES r FOOTING SCHEDULE COLUMNBASEPLATES UN0. 1 REINFORCEDCONCRETESHACL REDESIGNED M/XEDANDPLACED/N F3 B IH/S 9kFT I I I I -------- N 1 r----- -------- ------ D---------- ---------� rN --- -----� -� r -------------------------------- -------------- D Ffl L_ J I /. \ �- - - - - - - - - /2 6 I /I E26E-,r5 5 n \ HAIRP/N%' / \' \ HAIRPIN /' I \ 1'2" �- TIF2 I F2 I CI - - - - - - - - - - I I I -� I I _ LL _ _ _ CONTROL ✓T TYP � I R 1 I L o -J N I I 51B•EPDXY II I I I ♦ AAS I I I T0. SLABEL. 100'0 REF II I I I W '�^ ( ) I I 6"CONCRETESL48RE/NFORCEDIMTH04BARSATI6" I Ica o7c EW SUPPORTED ONSUITABLECHA/RSAT CENTER I ti m OFSLAS SLASTOSEPLACEDON6"OFGRANULAR Lw FILL COMPACTEDT095%SPD, ON24"OF COMPACTED I I �e o STRUCTURAL FILL. SUBGRADE TO BE COMPACTED TO I o 95%SP0AT0PTLMUMM0/S7URE((i2%)CONTROL I I �14115�1 Gj�Gi oJOINTSTOBE3/4"DEEPSAW-CUTSATAPPROX fO'olc I I J o EW NOM. FLOORSLAB FINISH TOBESTEEL TROWEL AND FLATNESS TO BEF30IF20LOCAL AND F457F30 I ` OVERALL I fau�dafi 0 CONTROL ✓T TYP I I I I ANCHORS I I FZ L - - \ / LIF2 I L_ B _ _J I I I I I I I I HAIRPIN- / I HALRP/N \. I I 5' / D 2�611 26" ---- - 2 I I +o ` I- 1 Y-�- \ / ° ° - S�"EPDXY 5/B"EPDXY !� j \ I / j 5/8"EPDXY � 5/8'EPDXY F - - - - -- - - - - -- - - - 4 - - - - - ANCH I ANCFlORS o I I ANCHORS ANCHORS jF1 - I n 1' v --------- - ---- --------------- -� L------- ----------- ---------- A m ---- ---- B -- ----J .B I -- 8" HIS .HEET HS nlrssvcEr �F3 ILF3 2'0 4" 124" 80" 10'0 -DOOR 4'8 64" 0 10'0"DOOR 64" 114" 22'8" 278" 68'0" COI 4" 1171" 1112" WALL RE/NF COI BASEPLATE N DETA/L C (4) A5 VERTS (4) 518VAB-L w/A3 TIE SETS 8" PIER I & DI DETAIL SEE PL AN FOR ORIENTA TION NTS ALL HIGH STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR. PROVIDE APPROVAL REPORT AT FRAMING INSPECTION r WALL REINF BASEPLATE COI DETAIL A (4) 5/8'WAS-L (4) A'S VERTS w/t3 TIE SETS -PIERS I & CI DETAIL SEE PL AN FOR ORIENTA TION NTS (8) A'5 VL w/A4 TIE, COI 'a FOUNDATIONPLAN SCALE 1/4"= 1'0" WORI(TH/SDRAWINGSWTHGENERAL STEEL CORPORA TION DRAWINGS FI, F2, F3 COLUMN BASE REACT/ONSPROVLDEDBYGENERAL STEEL CORPORATION DOORJAMB BOL TS TO BEEPDXYANCHORS RE/NF m b h BASEPLATE DETAIL D (4) 374 BAB -L PIER A2, D2, A3 & D3 DETAIL SEEPLANFOR ORIENTATION NTS OPEN -HOLE SOILS REPORT IS REQUIRED AT FOOTING INSPECTION 'lam PSF COI 3" WALL REINF BASEPLATE DETAIL A JII (4) 5/87AS-L COI (4) 05 VERTS w/A'3 TIE SETS PIER 34 & C4 DETAIL SEE PL AN FOR ORIENTA TION NTS Nat Fkoiafk, et - Wk9f aV)ti (I) (,calk AW Upl l 3(ou x $OV V►1ih. 9i�,c iv 000V C, 1 STRUCTURAL FILL DETAIL FOOT/NG L x W h REINFORCEMENT NOTES F-1 1'012'0" 10" (3)05EW F -Z 3'013'0" 10" (3)A'5EW F-3 5'0'170" 11" (5)95 L. W. &(7)99SW ACCOROANCEW/TH THE LA7EST EDITION OF THEA Cl COVEAND APPL ICABL E ASTM STANDARDS PLAICEMENTOFCONCREFE/N COL D WEA THER SHAL L MEET THERECOMMENDATIONOFAC/306. ANDAC1305FORHOT KVTHER CONCRETEPLACEMENT 2 ALL REINFORCING BARS BEING PLACED BY THE CONTRACTOR, #40R LARGER SHALL BENEWGRADE60 DEFORMED BARS A`3 SHALL BEGRADE40 DEFORMEDBARS WH/CHCONFORMTOASTMA615 (4) A'3 TIES 3 REINFORCING BARS SHALL IVOTSESENT OR STR41GHTENED INANY AT 3"o/c MANNER WH/CH WOULD BEIN✓URIOUS TO THESTEEL. BARS WITHK/NKSOR COLUMN PIER SEE SENDSNOT SHOWNON THEBAR BENDING DIAGRAMS SHALL NOTBEPLACED DETAILS THIS SHT THE USEOFHEAT TO STRAIGHTENORBEND REINFORCING STEEL WILL NOT BEPERM/TTED UNLESS SPECIF/CALL YAPPROIiEDBYTHEENG/NEER 03 TIES VERTS REINFORCING BARS SHALL SEPROPERLYSUPPORTED, TIED, ANDIOR AT 11"o% ANCHORED TO PREVENT DISPLACEMENT MIN/MUM LAP SPLICES SHALL BE (32) BAR DIAMETERS UN 0. ANYEMBEDDED ITEMSNOTSHOWNONTHESE PLA NS �- SHALL NO TBE PLA CED IN CONCRETE WAL C S, BEAMS OR0THERSTRUCTURAL MEMBERSWITHOUTPRIORAPPROVAL. 4 CONCRETEFOR THEPROJECT SHALL BEASFOLLOWS REINF ASTMC-150 TYPE V SULFATERES/STANT OREO. PORTLAND CEMENT WLTHA WATER/CEMENT RATIO (WIC)NOT TO EXCEED 050 ANDA MIN/MUMCOMPRESSIV LxW STRENGTHASFOLLOWS FOUNDAT/ON ELEMENTS = 3, 000 PS/ TYPICAL EXTERIOR COL WN FOOTING DETAIL FLOOR SLAB ELEMENTS= 4, 000 PSI ALL CONCRETE SHALL CONTAIN 6.0%(t 15%)ENTRA/NEDA/RAT THE POINT OF PLACEMENT AIR ENTR41NINGAGENT SHALL BESHOWN/N THEDES/GNM/X CONCRETESHALL BEM/XED/NAPPROVEDTRANSIT MIXERS MAX/MUM ELAPSED TIME FROM THE TIME THA TWATER IS 3"THREAD F 3"THREAD ADDED TOTHEM/XUNTIL THECONCRETE/SDEPOSITEDINTHE 0 3"PROD 3"PRO✓ WORKSHALLNOTEXCEED90MINUTES ON( YTHOSE ADM/XTURES SPECIFIED IN THE CONTRACTORSM/XDES/GN SUBMITTAL SHALL BE USED CONCRETE SHALL BE MIXED FOR NOTLESS THAN 70 NOR MORE THAN 100 REVOL UT/ONS ATM/X/NG SPEED PRIOR TO PLACEMENT NOM MAX &LIMPSHALL NOTEXCEED4" 6" L4" L 5 ENGINEERSPRIORAPPROVAL MUSTBESECUREDFORALL SUBSTITUTIONS EN THE 314"EAS--L DETAIL 5/S'.'�AB-L DETAIL FACEOFCONCRETEANDTHEOUTSIDE OFUMCLE4RDISTANCESETHERE/NFORCINGBAR�ALLSEI" A-307 A-307 7 CONSTRUCTION✓OINTSNOT SHOWNON THEDRAWINGS SHALL BELOCATED TO LEAST/MPA/R THESTRENGTHOF THESTRUCTUREAND THELOCATION TOC EL. MUSTSEAPPROVEDBYTHEENG/NEER 8" SLOPE/FREOD 100'0 8 BEFOREANYCONCRETFISPLACED, APPLICABLEDRAW/NGSSHALL BE A`5�a 18"a/c CO T.O.0 EL. 100'0 CHECKED TO DETERMINE THA TANCHOR SOL IS, EMBEDDED STEEL, PIPING, CONDUITS, GROUNDINGWLRES, OPEN/NGS ETC. AREPROPERLYPLACED. 1/Z„EYP 24” P. LATERAL SUPPORTSHALL SEPROVIDEDFORALL WALLSDUR/NG BACKF/LLINGANDCONSTRUCTION OPERATIONS JT TYP 24' 10 FOR CATHODICPROTECTION ALL UNDERGROUND CONCRETE WITH EMBEDDEDPIPING OR INSERTS WHICHAREA PART OF THEPIPING SHALL (2)45-J1P" HAVEA M/N/MUMOF I-1/2"CLEARANCESETWEENREBARSAND SUCHINSERTS A'5@18"VERT CONT ANCHOR BOL TS SHALL BESET WITH TEMPLATES ALTLEGEW A'5@18" 8" EL. 97'0 11 ANCHOR BOL T MATERIAL SHALL CONFORM TO 7HEREQU/REMEN7S OF o/c EL. 97'0 ASTRA307ORASTMA36 MATER/AL FORANCHOR SOL TS SHALL SEAS INDICA TED DNA PARTICULAR DRAWNG /FNO MATERIAL IS SPECIFIEDASTM y` A-307 SHALL BE USED. ANCHOR SOLTSAND OTHER PROJECTING EMSEDMENTS (2)45CONT (ZJ A5CONT. SHALL BESET WITHTEMPLATES OROTHERAPPROVEDMETHODS TO PREVENT DRAIN/F o DRA/N/F o D/SPLACEMENTDUR/NG CONCRETEPLACEMEN7 READ 16„ REOD 12 WELD/NGOFRE/NFORC/NG PIPESLEEVES, ETC TOANCHOR SOL TS WILL p NOTBEPERM/TTED UNLESS OUTLINED ELSEWHERE/NTHESENOTES SECTION A SECTION B 13 ALL EXPOSED UNFORMED CONCRETESURFACES SHALL BE OF UNIFORM F/N/SHANO COLOR. ALL FORMED SURFACES SHALL HAVEDEFECTSAND THIS SHEET THIS SHEET BLEM/SHESPATCHEDANDREP4/REOINAWt7RKMANL/KEMANNER 14. WELDEDPLAIN W/REFABR/C FOR CONCRETERE/NFORCEMENTSHALL Z CONFORM70ASTMA185 24"M/N a 15 WHEREALLOWEDONTHEPLANSSLABS ONGRADE(SOGJMAYBE W REINFORCED W7THSYNTHETICF/BERADDITIVECONTA/N/NGA M/N/MUMOF 15 178"x3/4"DEEP LBS OF COLLATED FIBRIL LA TED POLYPROPYLENE FIBERS PER CUBIC YARD OF SAW-CUTFILLED CONCRETE, AND THOROUGHL YMIXED INACCORDANCE WiTH THE w/EPDXYJT FILLER MANUFACTURERSDIRECTIONS 16 SPLICES/NRE/NFORCINGSTEEL SHALL BE/NACCORDANCEWITHDETAILS TYPICAL CONTROL JOINT MATCHHOR/Z SHOWN ON THE DRAWINGSORINA CCORDANCEIMTHTHEA C/DETAIL ING SLABONGRADE REINF S/ZEAND MANUAL (LATEST ED) LOCA TION OF SPL ICES NOTSHOWNONTHE DRAWING NTS NUMBER TYP SHALL BESUB✓ECTTOTHEAPPROVALOFTHEENG/NEERM/N/MUM LAP SPLICELENGTHSFORREINFORC/NG BARS SHALL BE/NACCORDANCEWITH AC/SP-66AC/DETA/LING MANUAL LATESTED/T/ON UNLESS OTHERWISE SHOWN ON THE DES/GN DRAWINGS TYPICAL CORNER RENF. DETAIL 17 WHEN CALLED FOR ON THEPLANSBASEPLATES ORSTEEL BEAMS TYP ATALL WALL & FTG. CORNERS&INTERSECT/ONS REST/NG ON CONCRETE ORMASONRYFOUNDATIONS SHALL RECEIVEAMIN N TS OF I "STRUCTURAL NON-SNR/NKGROUT UNLESS OTHERW/SENOTED ON THE DES/GNORAW/NGS STRUCTURAL GROUT SHALL HAVEA MINIMUM 1/18x 18"SMOOTH TOOLEDJOINTw/ COMPRESSIVE STRENGTH OF5000PS/AT28DAYS ALL GROUTSHALL BE RODw/SLEEVEAT M/N/MUMRADIUS MASTER SUILDERSCO.ORAPPROVEDEQUAL. l8"o% ATCNTR. SLAB 18. FOUNDAT/ON/NSULATION DRALNSYSTEM, AND VENTILATIONSHALL SEAS DES/GNEDBYOTHERS Q 19 FOUNDATION WALLS SHALL SEADEOUATELYBRACEOLATERALLYPRIORTO a AND DURINGSACKF/LL AGA/NSTFOUNDATION WALLS c h 20 WOOD PLA TES SHALL BEANCHORED TO THEFOUNDATION W/TH 1/2'gx8' EMBEDMENTANCHORBOLTSw/NUT& STEEL WASHER SPACED NOTMORE THAN48"ONRUNS, AND NOTMORETHAN6''12"FROM CORNERS, ANDAT ALL PLATEENOS/NCLUDINGSUTTSPLICES 12"TYP 2f ALL EARTHWORK GRADING, COMPACT/ON, DRA/NAGE, FOUNDATIONDRAIN, AND BACKFILL SHALL REDONE /NACCORDANCEWITHTHECTL THOMPSON,, INC REPORT DATED 18 SEPTEMBER 2017, JOB NO. GS06169000-125 FOOT/NGS HA VE BEEN SIZED TYPICAL CONSTROCTIONJOINT FOR ANASSUMEDM/N/MUMALLOWABLEBEARING PRESSURE OF2,,000PSFRESTING SLABONGRADEw/VEH/CULAR TRAFF/C ONCOMPACTEDSTRUCTURAL F/LL ASOUTL/NEO /NTHEREPORT M/N/MUMFROST NTS PROTECTION COVER FORALL EXTERIOR FOOT/NGS /S 36 INCHES 22 EPDXYFOROOWELSANDANCHORSOLTSINTOEX/ST/NGFOUNDATION #6 HAIRPIN SUPPORTED SHALL BESIKADUR31-H/MOD GEL ORANAPPROVEDEOUAL /NSTALLEDPER INSTALL HAIRPIN ONSUITABLECHAIRS MANUFACTURERS INS TRUCTIONS AROUND BOL IS HA/RPINAT CENTER OF SLA8ONSUITABLE CHAIRS NOTE UPON RECEIPT OF THIS DRAWINGS THE CONTRACTOR/BUILDER SHALL MAKEA THOROUGHANDDETAILED REV/EWOFALL ELEMENTSOFTHIS DRAW/NG AND NOTEANY DISCREPANCIES, CONFLICTS, ERRORS, OMISSIONS, OR OTHERIRREGULARITIES AND / \ PROMPTLYREPORTANYSUCHF/ND/NGSTOTHEOWNERANDTHEENGINEERPRIORTO / \ ANYPROCUREMENT, FABRICATION, OR CONSTRUCTION 60° \ &x20'CONT HAIR P/N TYP. HAIR PIN DETAIL 8' 12' 16 cc wcaArn� A"r"onyx.. \ RE �� ¢ Z o �s%, DRAWING ISSUE STATUS VANGUARD OPERATING LLC DRAWN ACAD2018 081/ �� A.K„•,T �� as + CHECKED.' SAK iii` S� APPROVED FOR 112 RED FEATHER TRAIL APPROIED: `c4:� APPRSCASCALL 1/a° = 1'-0° w Z 22262 CONSTRUCTION FOUNDATION PLAN CAD FILENAME DO NOT SCALE DRAWING FOR COMMERCIAL OR CONST PURPOSES w Z o �Q/ PROJECT NUMBER: Centimeters Inches Tenths ar ^^ > CCK S)7WJCTUR4L EAkWVEEFii5' PLAN AND DETAILS 0 19 SEPT 2017 ISSUED FOR CONSTRUCTION � •� �\�����\ R/FIE, COLORADO NSPE cc DRAWING NUMBER DRAWING NUMBER DRAWING NUMBER NUMBER DATE REVISION DESCRIPTION Er�p}f 'k 970-625-2774 CcEc DATE: 19 SEPEMBER 2017 SILT, COLORADO S1.1 0 SPLICE PLATE & BOLT TABLE Qty Mark Top Bot Int Type Dia Length Width Thick Length SID ''1 4 4 0 A325 3/4" 2" 6" 1/2" 1'-9 7/8" STIFFENER TABLE Web date Thick Lenqt RF1-1 9.0 16.0 Stiff 128.7 Plate Size 16.0/16.0 Mark Mark Width Thick Length RF1-1 St- 1 2 1/2 1/4;; 16" RF1-3 St- 1 2 112 1/4" 16 BASE PLATE TABLE Col Plate Size Mark Width Thick Length BP -1 6" 3/8" 9 1/2" FLANGE BRACES: BOTH SIDES(UNLESS NOTED) FBxxA(1): xx=length(in) A - L2X2X14G 12 3" Gd\ lua nne 26 Gauge PBR, 8 1/ 17'-334" X40 18'-0 3 4„ 4Q 4'-2316" F52–B -4�4 4lr-a- 1 _4„ Mark Web De th Start End Web date Thick Lenqt RF1-1 9.0 16.0 0.156 128.7 DESCRIPTION 16.0/16.0 0.185 18.4 RF1-2 15.0/15.0 0.156 191.9 RF1-3 16.0/16.0 0.185 18.4 7/13/17 1 16.0/ 9.0 0.156 128.7 17'-3 3/4" 18'-0 3/4„ 4— @ 4-22 3/16" Fg�A�1) FB32.8A 1— o� F832.8A 1) FB32.8A 1) o� FB32 RA(i) — — outside riange I x Thk x Len th 5 x 1 4 x 145.8 5 x 1/4" x 24.6 5 x 1/4" x 190.6 5 x 1/4" x 24.6 5 x 1 /4" x 145.8 Inside Flange W x Thk x Length 5 x 1/4" x 128.9 5 x 1/4 11 x 190.6 5 x 1/4" x 128.9 3" -16-1 f -a- FRAME CROSS SECTION: FRAME LINE 2 3 DESCRIPTION BY CK'D DSN ISSUE DATE I A 7/13/17 1 FOR CONSTRUCTION PERMIT PNR PNR AJL GENERAL NOTES: 1. ALL BOLTED JOINTS WITH A325M-09 TYPE 1 BOLTS ARE SPECIFIED AS SNUG TIGHTED JOINTS IN ACCORDANCE WITH THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, JUNE 30, 2004". PRETENSIONING METHODS, INCLUDING TURN -OF -NUT, CALIBRATED WRENCH, TWIST OFF TYPE TENSION BOLTS OR DIRECT TENSION INDICATOR ARE NOT REQUIRED. INSTALLATION INSPECTION REQUIREMENTS FOR SNUG TIGHT BOLTS (SPECIFICATION FOR STRUCTURAL JOINTS SECTION 9.1) IS SUGGESTED. 2. ALL FIELD WELDED CONNECTIONS OF SECONDARY FRAMING SHALL BE BOLTED WITH A325 MACHINE BOLTS 3. INSTALL ALL FLANGE BRACES ON COLUMN AND RAFTER AS SHOWN GENERAL STEEL CORPORATION 10639 W. BRADFORD RD PHONE : 800-406-5126 LITTLETON, CO 80127-4208 FAX 303-979-0084 PROJECT: M21350 - CHASE PEARL CUSTOMER: VANGUARD OPERATING LLC OWNER: VANGUARD OPERATING LLC LOCATION: NEW CASTLE, CO 81647 1/4 1) CAD DATE SCALE PHASE BUILDING ID JOB NUMBER SHEET- NUMBER ISSUE 7/13/17 N.T.S. 1 A 15-13-88709 E7 A 12 -r� BUILDER/CONTRACTOR RESPONSIBILITIES Drawing Validity — These drawings, supporting structural calculations and design certification are based on the Shop Primed Steel — All structural members of the Metal Building System not fabricated of corrosion resistant order documents as of the date of these drawings. These documents describe the material supplied by the material or protected by a corrosion resistant coating are painted with one coat of shop primer meeting the manufacturer as of the date of these drawings. Any changes to the order documents after the date on these performance requirements of SSPC Paint Specification No. 15. All surfaces to receive shop primer are cleaned of drawings may void these drawings, supporting structural calculations and design certification. The loose rust, loose mill scale and other foreign matter by using, as a minimum, the hand tool cleaning method Builder/Contractor is responsible for notifying the building authority of all changes to the order documents which SSPC—SP2 (Steel Structures Painting Council) prior to painting. The coat of shop primer is intended to protect the result in changes to the drawings, supporting structural calculations and design certification. steel framing for only a short period of exposure to ordinary atmospheric conditions. Shop Primed steel stored in THE BUILDER IS THESE LOADS COMPLY WITH THE REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT. the field pending erection should be kept free of the ground and so positioned as to minimize water—holding Builder Acceptance of Drawings — Approval of the manufacturer's drawings and design data affirms that the pockets, dust, mud and other contamination of the primer film. Repairs of damage to primed surfaces and/or manufacturer has correctly interpreted and applied the requirements of the order documents and constitutes removal of foreign material due to improper field storage or site conditions are not the responsibility of the Builder/Contractor acceptance of the manufacturer's interpretations of the order documents and standard product manufacturer. The Manufacturer is not responsible for deterioration of the shop coat of primer or corrosion that specifications, including its design, fabrication and quality criteria standards and tolerances. (AISC code of may result from exposure to atmospheric and environmental conditions, nor the compatibility of the primer to any standard practice Sept 86 Section 4.2.1) (Mar 05 Section 4.4.1) field applied coating. Minor abrasions to the shop coat (including galvanizing) caused by handling, loading, shipping COLLATERAL (LIGHTS) 0.5 PSF unloading and erection after painting or galvanizing are unavoidable. Touch—up of these minor abrasions is the Code Official Approval — It is the responsibility of the Builder/Contractor to ensure that all project plans and responsibility of the End Customer (MBMA 06 IV 4.2.4) specifications comply with the applicable requirements of any governing building authority. The Builder/Contractor ROOF LIVE LOAD 20.00 PSF (NON REDUCIBLE) is responsible for securing all required approvals and permits from the appropriate agency as required. PROJECT NOTES ROOF SHEETING PLAN Material properties of steel bar, plate, and sheet used in the fabrication of built—up structural framing members Builder is responsible for State Federal and OSHA safety compliance — The Builder/Contractor is responsible for conform to ASTM A529, ASTM A572, ASTM A1011 SS, or ASTM A1011 HSLAS with a minimum yield point of 50 applying and observing all pertinent safety rules and regulations and OSHA standards as applicable. ksi. Material properties of hot rolled structural shapes conform to ASTM A992, ASTM A529, or ASTM A572 with SNOW LOAD a minimum specified yield point of 50 ksi. Hot rolled angles, or other than flange braces, conform to ASTM 36 Building Erection — The Builder/Contractor is responsible for all erection of the steel and associated work in minimum. Hollow structural shaped conform to ASTM A500 grade b, minimum yield point is 42 ksi for round compliance with the Metal Building Manufacturers drawings. Temporary supports, such as temporary guys, HSS and 46 ksi for rectangular HSS. Material properties of cold form light gage steel members conform to the braces, false work or other elements required for erection will be determined, furnished and installed by the requirements of ASTM A1011 SS Grade 55 or ASTM A1011 HSLAS Class 1 Grade 55, with a minimum yield point erector. (AISC Code of Standard Practice Sept 86 Section 7.9.1) (Mar 05 Section 7.10.3) of 55 ksi. Discrepancies — Where discrepancies exist between the Metal Building plans and plans for other trades, the Metal All bolt joints with A325 Type 1 bolts are specified as snug—tightened joints, unless noted otherwise, in Buiiding pians will govern. (AISC Code of Standard Practice Sept 86 Section 3.3) (Mar 05 Section 3.3) accordance with the "Specification for Structural Joints using ASTM A325 or A490 bolts, June 30, 2004". A Pretensioning methods, including turn—of—nut and calibrated wrench are not required unless noted otherwise. Materials by Others — All interface and compatibility of any materials not furnished by the manufacturer are the SNOW EXPOSURE FACTOR (Ce) 1.0 V411 K4.Gl/ responsibility of and to be coordinated by the Builder/Contractor or A/E firm. Unless specific design criteria The manufacturer does not assume any responsibility for the erection nor field supervision of the structure and concerning any interface between materials if furnished as a part of the order documents, the manufacturers or any special inspections (including inspection of the high strength bolts or field welds) as required during assumptions will govern. erection. The coordination and the costs associated for setting up and Special Inspections are the responsibility PARKWAY W., HOUSTON, TX 77064. THE PROFESSIONAL ENGINEER WHOSE SEAL APPEARS HEREON IS EMPLOYED of the Erector, Owner, Architect, or Engineer of Record. Correction of Errors — Normal erection operations include the correction of minor misfits by moderate amounts BASIC FORCE RESISTING SYSTEM* of reaming, chipping, welding or cutting and the drawing of elements into line through the use of drift pins. Design is based upon the more severe loading of either the roof snow load or the roof live load. Errors which cannot be corrected by the foregoing means or which require major changes in the member d p,, configuration should be reported immediately to the owner and fabricator by the erector, to enable whoever is Loads, as noted, are given within order documents and are applied in general accordance with the applicable responsible either to correct the error or to approve the most efficient and economical method of correction to provisions of the model code and/or specification indicated. Neither the manufacture nor the certifying engineer be -used by others. (AISC Code of Standard Practice Sept 86 Section 7.12)(Mar 05 Section 7.14) declares or attests that the loads as designated are proper for the local provisions that may apply or for site specific parameters. The manufacturer's Engineer's certification is limited to design loads supplied by an Modification of the Metal Building from Plans — The Metal Building supplied by the manufacturer has Architect and/or engineer of record for the overall construction project. been designed according to the Building Code and specifications and the loads shown on this drawing. Modification of the building configuration, such as removing wall panels or braces, from that shown on these This project is designed using manufacture's standard serviceability standards. Generally this means that all plans could affect the structural integrity of the building. The Metal Building Manufacturer or a Licensed stresses and deflections are within typical performance limits for normal occupancy and standard metal building Structural Engineer should be consulted prior to making any changes to the building configuration shown on products. If special requirements for deflections and vibrations must be adhered to, then they must be clearly these drawings. The Metal Building Manufacturer will assume no responsibility for any loads applied to the stated in the contract documents. building not indicated on these drawings. Safety Commitment — The Metal Building Manufacturer has a commitment to manufacture quality building X—bracing (if applicable) is to be installed to a taut condition with all slack removed. Do not tighten beyond components that can be safely erected. However, the safety commitment and job site practices of the erector this state. are beyond the control of the building manufacturer. It is strongly recommended that safe working conditions The design collateral load has been uniformly applied to the design of the building. Hanging loads are to be and accident prevention is the top priority of any job site. Local, State and Federal safety and health attached to the purlin web. This .may not be appropriate for heavily concentrated loads. Any attached load in standards, whether standard statutory or customary, should always be followed to help ensure worker safety. excess of 150 pounds shall be accounted for by special design performed by a licensed engineer using Make certain all employees know the safest and most productive way to erect a building. Emergency procedures concentrated loads and may require separate support members within the roof system. should be known to all employees. Daily meetings highlighting safety procedures are also recommended. The use of hard hats, rubber sole shoes for roof work, proper equipment for handling material, and safety nets where This metal building system is designed as enclosed. All exterior components (i.e. doors, windows, vents, etc.) applicable, are recommended. For purposes of determining lift requirements, no bundles supplied by the must be designed to withstand the specified wind loading for the design of components and cladding in manufacturer will exceed 4000 lbs. For further information also reference the bill of materials for individual accordance with the specified building code. Doors are to be closed when a maximum of 50% of design wind member weights of other structural members. If additional information is required contact the customer service department. velocity is reached. DESIGN LOADING The metal building manufacturer has not designed the structure for snow accumulation loads at the DRAWING INDEX THIS STRUCTURE IS DESIGNED UTILIZING THE LOADS ISSUE PAGE DESCRIPTION INDICATED AND APP AS REED n^ BC 12 ?OIC A C1 COVER SHEET THE BUILDER IS THESE LOADS COMPLY WITH THE REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT. 0 F1 ANCHOR BOLT PLAN 0 F2 ANCHOR BOLT REACTIONS ROOF DEAD LOAD SUPERIMPOSED 2.170 PSF 0 F3 ANCHOR BOLT DETAILS COLLATERAL (LIGHTS) 0.5 PSF A E1 ROOF FRAMING PLAN THIS CERTIFICATION COVERS PARTS MANUFACTURED ROOF LIVE LOAD 20.00 PSF (NON REDUCIBLE) A E2 ROOF SHEETING PLAN AND DELIVERED BY THE MANUFACTURER ONLY, RISK CATEGORY II — Normal A E3 FRONT SIDEWALL SNOW LOAD A E4 BACK SIDEWALL PSF GROUND SNOW LOAD (Pg) 440P A E5 LEFT ENDWALL SNOW LOAD IMPORTANCE FACTOR (Is) 1��� A E6 RIGHT ENDWALL FLAT ROOF SNOW LOAD (Pf) 2SF (AS PER CODE) MIN ROOF SNOW LOAD (Pf) 40.00 PSF (USED IN DESIGN) A E7 FRAME CROSS SECTION SNOW EXPOSURE FACTOR (Ce) 1.0 V411 K4.Gl/ A DET1-10 STANDARD DETAILS THERMAL FACTOR (Ct) 1.00 � lJl11/�ti�y NO�C : _ BASIC STRUCTURAL SYSTEM (FROM ASCE 7-10 TABLE 12.2-1) PARKWAY W., HOUSTON, TX 77064. THE PROFESSIONAL ENGINEER WHOSE SEAL APPEARS HEREON IS EMPLOYED WIND LOAD 1 f �'Ovi�J.0 a+ 14tgt oH.0 () �oclk d oo� BASIC FORCE RESISTING SYSTEM* ULTIMATE WIND SPEED 115 MPH roof, gutters, trim, etc. if left on building surfaces for a long enough time. The roof should be periodically d p,, H. STRUCTURAL STEEL SYSTEMS NOT SPECIFICALLY inspected for such conditions and if found, they should be removed. NOMINAL WIND SPEED (vasd) 89 MPH (IBC SECTION 1609.3.1) SERVICEABILITY WIND SPEED 76 MPH WIND EXPOSURE CATEGORY C DRAWING STATUS TOPOGRAPHICAL FACTOR 1.0 ❑ FOR APPROVAL INTERNAL PRESSURE COEFFICIENT (GCpi) 0.18 /-0.18 THESE DRAWINGS, BEING FOR APPROVAL, ARE BY DEFINITION NOT FINAL, AND ARE FOR CONCEPTUAL ZONE 4, COMPONENT WIND LOAD < 10FT2 REPRESENTATION ONLY. THEIR PURPOSE IS TO 26.418 PSF PRESSURE -28,619 PSF SUCTION CONFIRM PROPER INTERPRETATION OF THE PROJECT DOCUMENTS. ONLY DRAWINGS ISSUED ZONE 5, COMPONENT WIND LOAD < 10FT2 "FOR ERECTOR INSTALLATION" CAN BE CONSIDERED 26.418 PSF PRESSURE -35.158 PSF SUCTION AS COMPLETE. ZONES PER ASCE 7-10; FIG. 30.4-1 ZONES PRESSURES SHOWN ARE UN—FACTORED FOR CONSTRUCTION PERMIT RAIN INTENSITY THESE DRAWINGS, BEING FOR PERMIT, ARE BY 5—MINUTE DURATION, 5—YEAR DEFINITION NOT FINAL. ONLY DRAWINGS ISSUED RECURRENCE (11) 4.0000 IN/HOUR "FOR ERECTOR INSTALLATION" CAN BE CONSIDERED AS COMPLETE. SEISMIC LOAD SEISMIC IMPORTANCE FACTOR (le) 1.00 ❑ FOR ERECTOR INSTALLATION Ss 0.3154 SDs 0.3251 FINAL DRAWINGS FOR CONSTRUCTION. S1 0.0808 SD1 0.1280 SITE CLASS D STIFF SOIL SEISMIC DESIGN CATEGORY B ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE Rev, 8/12/14 BUILDING SIZE: 36'-0" x 68'-0" x 13'-0" 1.0:12 ISSUE I DATE I DESCRIPTION BY CK'D DSN GENERAL STEEL CORPORATION A 7/13/17 1 FOR CONSTRUCTION PERMIT PNR PNR AJL 10639 W. BRADFORD RD PHONE 800-406-5126 LITTLETON, CO 80127-4208 FAX 303-979-0084 PROJECT: M21350 — CHASE PEARL CUSTOMER: VANGUARD OPERATING LLC OWNER: VANGUARD OPERATING LLC LOCATION: NEW CASTLE, CO 81647 CAD DATE SCALE PHASE BUILDING ID 7/13/17 N.T.S. 1 A JOB NUMBER 15-B-88709 SHEET NUMBER ISSUE C1 A Jul 19, 2017 The metal building manufacturer has not designed the structure for snow accumulation loads at the COLUMN LINE TRANSVERSE LONGITUDINAL Foundation Design —The Metal Building Manufacturer is not responsible for the design, materials and ground level which may impose snow loads on the wall framing provided e ma_n er. FRONT BACK workmanship of the foundation. Anchor rod plans prepared by the manufacturer are intended to show only BASIC FORCE RESISTING SYSTEM* H H H ENGINEERING location, diameter and projection of the anchor rods required to attach the Metal Building System to the SEAL foundation. It is the responsibility of the end customer to ensure that adequate provisions are made for ALL HIGH STRENGTH BOLTING AND RESPONSE MODIFICATION COEFFICIENT(R) 3 3 3 specifying rod embedment, bearing values, tie rods and or other associated items embedded in the concrete FIELD WELDING REQUIRES SPECIAL THIS CERTIFICATION COVERS PARTS MANUFACTURED foundation, as well as foundation design for the loads imposed by the Metal Building System, other imposed INSPECTOR. PROVIDE APPROVAL SYSTEM OVER—STRENGTH FACTOR(QD) 2.5000 2.5000 2.5000 AND DELIVERED BY THE MANUFACTURER ONLY, loads, and the bearingcapacity of the soil and other conditions of the building site. MBMA 06 Sections 3.2.2 P Y 9 ( REPORTATFRAMINGINSPECTION SEISMIC RESPONSE COEFFICIENT(Cs) 0.108 0.108 AND EXCLUDES PARTS SUCH AS DOORS, WINDOWS, and A3) 0.108 FOUNDATION DESIGN AND ERECTION OF THE BUILDING. BLDG DESIGN BASE SHEAR (V) TRANSVERSE1.56 (k) LONGITUDINAL1.54 (k) THESE DRAWINGS AND THE METAL BUILDING SYSTEM Dissimilar Materials — Never allow your roof to come in contact with, or water runoff from, any dissimilar metal THE TRANSVERSE DIRECTION IS PARALLEL TO THE RIGID FRAMES THEY REPRESENT ARE THE PRODUCT OF AN AFFILIATE including but not limited to: Copper and Arsenic Salts used in treated lumber, Calcium used in concrete, mortar THE LONGITUDINAL DIRECTION IS PERPENDICULAR TO THE RIGID FRAMES OF NCI GROUP, INC. — 10943 N. SAM HOUSTON and grout. NO�C : _ BASIC STRUCTURAL SYSTEM (FROM ASCE 7-10 TABLE 12.2-1) PARKWAY W., HOUSTON, TX 77064. THE PROFESSIONAL ENGINEER WHOSE SEAL APPEARS HEREON IS EMPLOYED Debris Removal — An foreign debris such as sawdust, dirt, animal dro in s, etc. will cause corrosion of the Y 9 droppings, 1 f �'Ovi�J.0 a+ 14tgt oH.0 () �oclk d oo� BASIC FORCE RESISTING SYSTEM* BY AN AFFILIATE OF NCI GROUP, INC. AND IS NOT THE ENGINEER—OF—RECORD FOR THE OVERALL PROJECT. roof, gutters, trim, etc. if left on building surfaces for a long enough time. The roof should be periodically d p,, H. STRUCTURAL STEEL SYSTEMS NOT SPECIFICALLY inspected for such conditions and if found, they should be removed. X �Ih g� `V V ��'GSS DETAILED FOR SEISMIC RESISTANCE Rev, 8/12/14 BUILDING SIZE: 36'-0" x 68'-0" x 13'-0" 1.0:12 ISSUE I DATE I DESCRIPTION BY CK'D DSN GENERAL STEEL CORPORATION A 7/13/17 1 FOR CONSTRUCTION PERMIT PNR PNR AJL 10639 W. BRADFORD RD PHONE 800-406-5126 LITTLETON, CO 80127-4208 FAX 303-979-0084 PROJECT: M21350 — CHASE PEARL CUSTOMER: VANGUARD OPERATING LLC OWNER: VANGUARD OPERATING LLC LOCATION: NEW CASTLE, CO 81647 CAD DATE SCALE PHASE BUILDING ID 7/13/17 N.T.S. 1 A JOB NUMBER 15-B-88709 SHEET NUMBER ISSUE C1 A Jul 19, 2017 GENERAL NOTES ENDWALL COLUMN: 1. THE REACTIONS PROVIDED ARE BASED ON THE ORDER DOCUMENTS Frm Col Dead Collat AT THE TIME OF MAILING. ANY CHANGES TO BUILDING LOADS Line Line Vert Vert OR DIMENSIONS MAY CHANGE THE REACTIONS. THE REACTIONS 1 D 0.2 0.0 WILL BE SUPERSEDED AND VOIDED BY ANY FUTURE MAILING. 1 C 0.6 0.1 2. REACTIONS ARE PROVIDED AS UN -FACTORED FOR EACH LOAD 1 B 0.6 0.1 GROUP APPLIED TO THE COLUMN. THE FOUNDATION ENGINEER 1 A 0.2 0.0 WILL APPLY THE APPROPRIATE LOAD FACTORS AND COMBINE THE 0.0 0.8 THE SOIL AND OTHER CONDITIONS OF THE BUILDING SITE, -0.4 0.0 1.5 0.0 REACTIONS IN ACCORDANCE WITH THE BUILDING CODE AND RIGID FRAME: BASIC IT IS RECOMMENDED THAT THE ANCHORAGE AND FOUNDATION OF DESIGN SPECIFICATIONS TO DETERMINE BEARING PRESSURES Frm Col Wind AND CONCRETE DESIGN. THE FACTORS APPLIED TO LOAD GROUPS Line Line -Press Harz Vert FOR THE STEEL COLUMN DESIGN MAY BE DIFFERENT THAN THE 1 D -2.3 -1.1 FACTORS USED IN THE FOUNDATION DESIGN. "MAXIMUM" 1 C -1.7 0.0 3. THE MANUFACTURER DOES NOT PROVIDE LOAD 1 B -1.7 0.0 COMBINATION REACTIONS. HOWEVER, THE INDIVIDUAL LOAD 1 A -2.3 -1.1 REACTIONS PROVIDED MAY BE USED BY THE FOUNDATION ENGINEER TO DETERMINE THE APPLICABLE LOAD COMBINATIONS FOR HIS/HER C 1.8 0.0 -2.6 DESIGN PROCEDURES AND ALLOW FOR AN ECONOMICAL FOUNDATION Frm Col -MIN -SNOW -- DESIGN Line Line Harz Vert 4. THE METAL BUILDING MANUFACTURER IS RESPONSIBLE FOR THE 1 D 0.0 1.5 DESIGN OF THE ANCHOR BOLT DIAMETER ONLY TO PERMIT THE 1 C 0.0 6.8 TRANSFER OF FORCES BETWEEN THE BASE PLATE AND THE 1 B 0.0 6.8 ANCHOR BOLT IN SHEAR, BEARING AND TENSION, BUT IS NOT 1 A 0.0 1.5 RESPONSIBLE FOR THE ANCHOR BOLT EMBEDMENT FOR TRANSFER Line Line Horiz Vert Horiz Vert Horiz OF FORCES TO THE FOUNDATION. THE METAL BUILDING Horiz Vert Horiz Vert Horiz Vert BASIC COLUMN REACTIONS (k ) Vert Live Snow Wind_Leftl 0.0 Vert Vert Harz Vert 0.8 1.1 0.0 -1.0 3.4 4.7 0.0 -4.2 3.4 4.7 1.4 -4.8 0.8 1.1 0.0 1.4 Wind_Suct Frm Harz Vert 0.0 1.1 1.8 0.0 1.8 0.0 0.0 1.1 E1UNB_SL_L- 4 Horz Vert 0.0 1.3 0.0 5.6 0.0 2.0 0.0 0.2 MANUFACTURER DOES NOT DESIGN AND IS NOT RESPONSIBLE FOR Frm Col Dead Collat Live THE DESIGN, MATERIAL AND CONSTRUCTION OF THE FOUNDATION Line Line Vert Vert Vert EMBEDMENTS. THE END USE CUSTOMER SHOULD ASSURE HIMSELF 4 A 0.2 0.0 0.8 THAT ADEQUATE PROVISIONS ARE MADE IN THE FOUNDATION 4 B 0.6 0.1 3.4 DESIGN FOR LOADS IMPOSED BY COLUMN REACTIONS OF THE 4 C 0.6 0.1 3.4 BUILDING, OTHER IMPOSED LOADS, AND BEARING CAPACITY OF 4 D 0.2 0.0 0.8 THE SOIL AND OTHER CONDITIONS OF THE BUILDING SITE, -0.4 0.0 1.5 0.0 0.2 RIGID FRAME: BASIC IT IS RECOMMENDED THAT THE ANCHORAGE AND FOUNDATION OF Wind THE BUILDING BE DESIGNED BY A REGISTERED PROFESSIONAL Frm Col Suct Wind_Longt - - - - ENGINEER EXPERIENCED IN THE DESIGN OF SUCH STRUCTURES, Line Line Harz Harz Vert (SECTION A3 MBMA 2006 METAL BUILDING SYSTEMS MANUAL) 4 A 0.8 0.0 -1.1 5. BOTTOM OF ALL BASE PLATES ARE AT THE SAME ELEVATION. 4 B 1.8 0.0 -4.2 (UNLESS NOTED) 4 C 1.8 0.0 -2.6 6. ANCHOR RODS ARE ASTM F1554 GRADE 36 MATERIAL UNLESS NOTED OTHERWISE. 4 D 0.0 0.2 -0.8 Frm Col E2UNB_SL_R- Line Line Harz Vert 4 A 0.0 0.2 4 B 0.0 2.1 4 C 0.0 5.6 4 D 0.0 1.2 Wind_Longl FRAME: Harz Vert 0.0 -1.1 0.0 -4.2 0.0 -2.6 0.2 -0.8 E1UNB_SL_R- Thick (in) Horz Vert 0.0 0.2 0.0 2.1 0.0 5.6 0.0 1.2 Wind_Rightl Harz Vert 0.0 -0.7 0.0 -2.8 0.0 -2.3 1.4 -2.9 Wind_Long2 Harz Vert 0.0 -0.5 0.0 -2.9 0.2 -4.4 0.0 -0.8 Wind_Left2 Horz Vert 0.0 -1.0 0.0 -4.2 1.4 -4.8 0.0 1.4 Seis-Left Harz Vert 0.0 0.0 0.0 0.0 0.3 -0.4 0.0 0.4 Wind_Right2 Horz Vert 0.0 -0.7 0.0 -2.8 0.0 -2.3 1.4 -2.9 Seis_Right Harz Vert 0.0 0.0 0.0 0.0 0.0 0.4 0.3 -0.4 Seis_Long Harz Vert -0.8 -0.4 0.0 0.0 0.0 0.0 -0.8 -0.4 Snow Wind_Leftl Wind_Rightl Wind_Left2 Wind_Right2 Vert Harz Vert Harz Vert Horz Vert Harz Vert 1.1 0.0 -1.0 0.0 -0.7 0.0 -1.0 0.0 -0.7 4.7 0.0 -4.2 0.0 -2.8 0.0 -4.2 0.0 -2.8 4.7 1.4 -4.8 0.0 -2.3 1.4 -4.8 0.0 -2.3 1.1 0.0 1.4 1.4 -2.9 0.0 1.4 1.4 -2.9 Wind_Long2 Horz Vert 0.0 -0.5 0.0 -2.9 0.2 -4.4 0.0 -0.8 Seis-Left Harz Vert 0.0 0.0 0.0 0.0 0.3 -0.4 0.0 0.4 Seis_Right-MIN_SNOW-- E2UNB_SL_L- Horz Vert Harz Vert Horz Vert Wind Press Harz -0.7 -1.7 -1.7 0.0 FRAME LINES: H 23 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc._Bolt Base -Plate (in) Grout Line Line Qty Dia Width Length Thick (in) 2* D 4 0.750 6.000 9.500 0.375 0.0 2* A 4 0.750 6.000 9.500 0.375 0.0 IV 0.0 0.0 0.0 1.5 0.0 1.3 2* Frame lines: 2 3 0.0 0.0 0.0 6.8 0.0 5.6 0.0 0.4 0.0 6.8 0.0 2.0 0.3 -0.4 0.0 1.5 0.0 0.2 RIGID FRAME: BASIC COLUMN REACTIONS (k ) Frame Column -----Dead-----Collateral- - - - - - Live - - - - - - - - - Snow-----Wind-Leftl - -Wind_Rightt- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2* D 0.4 1.3 0.1 0.2 3.1 8.2 4.3 11.4 -4.7 -8.8 0.3 -5.3 2* A -0.4 1.3 -0.1 0.2 -3.1 8.2 -4.3 11.4 -0.3 -5.3 4.7 -8.8 Frame Column--Wind_Left2- -Wind_Right2---Wind_Long1- --Wind_Long2- -Seismic-Left Seismic -Right Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2* D -4.6 -5.2 0.4 -1.7 -0.5 -8.9 -0.8 -7.5 -0.2 -0.2 0.2 0.2 NOTES FOR REACTIONS 2* A -0.4 -1.7 4.6 -5.2 0.8 -7.5 0.5 -8.9 -0.2 0.2 0.2 -0.2 BUILDING REACTIONS ARE BASED ON THE FOLLOWING BUILDING DATA: Frame Column-Seismic-Long -MIN_SNOW-- F1UNB_SL_L- F1UNB_SLR- WIDTH (FT) = 36 Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert LENGTH (FT) = 68 2* D 0.0 -0.4 6.2 16.3 3.5 11.6 3.5 6.2 EAVE HEIGHT FT) = 13 / 13 2* A 0.0 -0.4 -6.2 16.3 -3.5 6.2 -3.5 11.6 ROOF SLOPE rise/12) = 1.0:12 / 1.0:12 DEAD LOAD psf) = 2.170 2* Frame lines: 2 3 COLLATERAL LOAD (psf) ROOF LIVE LOAD (psf) = 0.5 = 20.00 (NON REDUCIBLE) ENDWALL COLUMN: ANCHOR BOLTS & BASE PLATES FRAME LIVE LOAD ( sf) ROOF SNOW LOAD psf) = 20 = 28 (AS PER CODE) Frm Col Anc._Bolt Base -Plate (in) Grout MIN ROOF SNOW LOAD (psf) = 40.00 (AS PER DESIGN) Line Line Qty Dia Width Length Thick (in) GROUND SNOW LOAD (psf) = 40.0000 WIND SPEED (MPH) = 115 1 D 4 0.625 6.000 8.000 0.375 0.0 NOMINAL WIND SPEED (vasd) = 89 MPH (IBC SECTION 1609.3.1) 1 C 4 0.625 6.000 8.000 0.375 0.0 SERVICEABILITY WIND SPEED = 76 MPH 1 B 4 0.625 6.000 8.000 0.375 0.0 WIND CODE = IBC 12 C 1 A 4 0.625 6.000 8.000 0.375 0.0 EXPOSURE CLOSED/OPEN = = Closed 4 A 4 0.625 6.000 8.000 0.375 0.0 IMPORTANCE - WIND = 1.00 4 B 4 0.625 6.000 8.000 0.375 0.0 IMPORTANCE - SEISMIC = 1.00 B 4 C 4 0.625 6.000 8.000 0.375 0.0 SEISMIC ZONE = 4 D 4 0.625 6.000 8.000 0.375 0.0 BUILDING BRACING REACTIONS Reactions in plane of wall ANCHOR BOLT SUMMARY f Reactions(k ) Panel -Shear -Wall - Col -Wind - -Seismic - (Ib/ft) Dia Proj Loc Line Line Harz Vert Harz Vert Wind Seis Qty Locate (in) Type (in) L_EW 1 B,A Bracing, see EW reactions * O 12 O 32 Jamb Endwall 5/8" 5/8" F1554 2.00 F1554 2.00 F -SW A 1,2 2.3 * R_EW 4 C,D Bracing, see 0.8 EW reactions 0 16 Frame 3/4" F1554 2.50 B_SW D 2,1 2.3 * 0.8 *See RF reactions table for vertical and horizontal reactions in plane of the rigid frame. ISSUE DATE I DESCRIPTION BY CK'D DSN 0 7/13/17 1 FOR ERECTOR INSTALLATION PNR PNR AJL GENERAL STEEL CORPORATION 10639 W. BRADFORD RD LITTLETON, CO 80127-420 PROJECT: M21350 - CHASE PEARL CUSTOMER: VANGUARD OPERATING LLC LOCATION: NEW CASTLE, CO 81647 PHONE 800-406-5126 FAX 303-979-0084 OWNER: VANGUARD OPERATING LLC CAD DATE SCALE PHASE BUILDING ID 7/13/17 N.T.S. 1 A MN LINE JOB NUMBER SHEET NUMBER ISSUE 15-13-88709 F2 D Jul 19, 2017 lr� I � I j u 1 j EC -4 RF1-3 RF1-3 EC— 5 8'-0" 10'-0" 4'-811 61-4 1) 10'-0" 6'-4" SIDEWALL FRAMING: FRAME LINE A Q T p T HW4062 GENERAL NOTES: 1. INSTALL ALL GIRTS AND FLANGE BRACES (FB) AS SHOWN. 2. WALL PANEL PROVIDES STRUCTURAL STABILITY TO THE BUILDING. 3. OTHER THAN FOR WALK DOORS AND WINDOWS SHOWN ON THE CONTRACT, DO NOT ADD ADDITIONAL WALL OPENINGS WITHOUT APPROVAL OF BUILDING MANUFACTURER OR PROFESSIONAL ENGINEER. 4. AFTER INSTALLATION, WIPE ALL PANELS CLEAN OF METAL I I F407 SIDEWALL SHEETING & TRIM: FRAME LINE A PANELS: 26 Gauqe PBR — Polar White MEMBER T MARK I PART LENGTH BY DJ -1 DSN 81`35C 14 10'-0" A 7/13/17 E-1 PNR 10ES1114 22'-7 1/2" E-2 1IDES 1-14 22'-7 1/2" E-3 10ES11-14 22'-7 1/2" G-5 8X25Z12 22'-7 PROJECT: M21350 — CHASE PEARL 1/2" G-6 8X25Z16 7'-8" G-7 8X35C14 22'-7 1/2" G-8 8X25Z16 4'-4" G-9 8X25Z16 6'-0" CAD DATE 7/13/17 G-10 PHASE 1 8X35C14 22'-7 SHEET NUMBER E3 1/2" G-11 8X25Z16 6'-0" CB -7 1/2" DIA. ROD 25-6" CB -8 1/2" DIA. ROD 25'-5" JB -1 8F35C14 1'-9 3/16" CONNECTION PLA FRAME LINE A ❑ ID MARK PA 2 1 SC584 L FLANGE BRACE TABLE FRAME LINE A 0 ID I PART I LENGTH FB29.3 I L2X2X14G 1 2'-5 1/4" ISSUE DATE DESCRIPTION BY CK'D DSN GENERAL STEEL CORPORATION 10639 W. BRADFORD RD PHONE 800-406-5126 LITTLETON, CO 80127-4208 FAX 303-979-0084 Jul 19, 2017 A 7/13/17 FOR CONSTRUCTION PERMIT PNR PNR AJL PROJECT: M21350 — CHASE PEARL D0 L/CF CUSTOMER: VANGUARD OPERATING LLC OWNER: VANGUARD OPERATING LLC LOCATION: NEW CASTLE, CO 81647 ¢ 42926 Ns CAD DATE 7/13/17 SCALE N.T.S. PHASE 1 BUILDING ID A JOB NUMBER 15—B-88709 SHEET NUMBER E3 ISSUE.c�',: A �SS�ONA4�G� FR' -n" ni IT-Tr)-ni IT OF QTFri 3 2 22'-8" 22,-8" 22'-8„ 18 E-1 Jz E-4 E-5 IS G-12 H2 G-13 FB29.3 G-14 10ES11-14 22'-7 1/2" E-5 1OES1114 22'-7 1/2" G-12 8X25Z16 25'-1 1/2" G-13 8X25Z16 27'-7 1/2" G-14 8X25Z16 25'-1 1/2" CB -7 RA1-1 25'-6' T1 112" DIA. ROD — — — — — — — — — — — — -- — — — — — H I — — — — — — — — — —— — — — — — T — — — — — — — — — — — — — — — — — — T J EC -6 RF1-1 RF1-1 EC -1 GIRT 2'-5 3/4 2'-5 3/4", LAPS 2'-5 3/4" 2'' 5 3/4" SIDEWALL FRAMING: FRAME EINE D I i N GENERAL NOTES: 1. INSTALL ALL GIRTS AND FLANGE BRACES (FB) AS SHOWN. 2. WALL PANEL PROVIDES STRUCTURAL STABILITY TO THE BUILDING. 3. OTHER THAN FOR WALK DOORS AND WINDOWS SHOWN ON THE CONTRACT, DO NOT ADD ADDITIONAL WALL OPENINGS WITHOUT APPROVAL OF BUILDING MANUFACTURER OR PROFESSIONAL ENGINEER. 4. AFTER INSTALLATION, WIPE ALL PANELS CLEAN OF METAL SHAVINGS CAUSED BY DRILLING. HW4062 F407 SIDEWAEE SHEETING & TRIM: FRAME LINE D PANELS: 26 Gauge PBR - Polar White ISSUE DATE DESCRIPTION BY I CK'D DSN GENERAL STEEL CORPORA TION A 7/13/17 FOR CONSTRUCTION PERMIT PNR PNR AJL 10639 W. BRADFORD RD PHONE 800-406-5126 LITTLETON, CO 80127-4208 FAX 303-979-0084 MEMBER TABLE FRAME LINE D MARK PART LENGTH E-1 1OES1L14 22'-7 1 2 E-4 10ES11-14 22'-7 1/2" E-5 1OES1114 22'-7 1/2" G-12 8X25Z16 25'-1 1/2" G-13 8X25Z16 27'-7 1/2" G-14 8X25Z16 25'-1 1/2" CB -7 1/2" DIA. ROD 25'-6' CB -8 112" DIA. ROD 25'-5" FLANGE BRACE TABLE FRAME LINE D V ID I PART LENGTH FB29.3 I L2X2X14G 2'-5 1 /4" PROJECT: M21350 - CHASE PEARL CUSTOMER: VANGUARD OPERATING LLC --OWNER-VANGUARD OPERATING LLC LOCATION: NEW CASTLE, CO 81647 CAD DATE 7/13/17 SCALE N.T.S. PHASE 1 BUILDING ID A JOB 15-B-88709 NUMBER SHEET NUMBER E4 ISSUE A 8 1/4" 12 �1" 12 GENERAL NOTES: 1. INSTALL ALL GIRTS AND FLANGE BRACES (FB) AS SHOWN. 2. WALL PANEL PROVIDES STRUCTURAL STABILITY TO THE BUILDING. 3. OTHER THAN FOR WALK DOORS AND WINDOWS SHOWN ON THE CONTRACT, DO NOT ADD ADDITIONAL WALL OPENINGS WITHOUT APPROVAL OF BUILDING MANUFACTURER OR PROFESSIONAL ENGINEER. 4. AFTER INSTALLATION, WIPE ALL PANELS CLEAN OF METAL SHAVINGS CAUSED BY DRILLING. 9'-3 RAI -1 36'-0" OUT—TO—OUT OF STEEL n I 1 EC -2 EC -3 ENDWALL FRAMING: FRAME LINE 1 � � o ENDWALL SHEETING & TRIM: FRAME LINE 1 PANELS: 2.6 Gauge PBR — Polar White 9'-3 3 4" RAI—i 1"1�_" 12 BEARING FRAME ONLY! LENGTH A BOLT TABLE WASHER TO BE USED AT ENDWALL COLUMN TO ENDWALL 2'-5 1/2" NE LOCATION 1 RAFTER CONNECTION. USE ONE WASHER ON COLUMN SIDE. ER-1/ER-2 WASHER NOT NEEDED ON CLIP SIDE. Cor -Column Raf W8X10 11'-7 Int -Column Raf W8X10 18'-1 MEMBI W8X10 18'-1 FRAME 1 8X25216 MARK 5X8 EC -1 15'-4" EC -2 1/2" DIA. ROD 11'-6" EC -3 1/2" DIA. ROD 9'-9" EC -4 1 /2" DIA. ROD ER -1 ER -2 G-1 G-2 CB -1 CB -2 8 A325 4 A325 4 A325 LENGTH 7r__1_ _3/�4 /8" 1 1/2" /2" 1 1 /4" LINE 1 PART LENGTH LENGTH W8X10 11'-7 2'-5 1/2" 1 8 L2X2X1/8 W8X10 12'-2 13/16" W8X10 12'-2 13/16" W8X10 11'-7 1 8" W8X10 18'-1 1/8" W8X10 18'-1 1 8X25216 8'-3 5X8 8X25Z16 15'-4" 1/2" DIA. ROD 11'-6" 1/2" DIA. ROD 9'-9" 1 /2" DIA. ROD 10'-0" FLANGE BRACE TABLE FRAME LINE 1 VID PART LENGTH FB29.5 L2X2X14G 2'-5 1/2" FB6-1 L2X2X1/8 2'-5 1/2" �1„10» 12 GENERAL NOTES: 1. INSTALL ALL GIRTS AND FLANGE BRACES (FB) AS SHOWN. 2. WALL PANEL PROVIDES STRUCTURAL STABILITY TO THE BUILDING. 3. OTHER THAN FOR WALK DOORS AND WINDOWS SHOWN ON THE CONTRACT, DO NOT ADD ADDITIONAL WALL OPENINGS WITHOUT APPROVAL OF BUILDING MANUFACTURER OR PROFESSIONAL ENGINEER. 4. AFTER INSTALLATION, WIPE ALL PANELS CLEAN OF METAL SHAVINGS CAUSED BY DRILLING. C E3 9'-2» RAI -1 36'-0” OUT -TO -OUT OF STEEL 16'-0" n 9'-2" RAI - I ['n I I I L -L of EC -5 EC -2 EC -3 EC -6 2'-0" 12'-0° ENDWALL FRAMING: FRAME LINE 4 Q Q Q Q F1 672-B CC I 11 F2379 -R F150�❑2 R I F407 ENDWALL SHEETING & TRIM: FRAME LINE 4 PANELS: 26 Gauge PBR - Polar White ISSUE DATE DESCRIPTION A 7/13/17 FOR CONSTRUCTION PERMIT BEARING FRAME ONLY! BOLTTABLE ABLE 4 WASHER TO BE USED AT ENDWALL COLUMN TO ENDWALL LOCATION RAFTER CONNECTION. USE ONE WASHER ON COLUMN SIDE. ER -3 ER -4 WASHER NOT NEEDED ON CLIP SIDE. Columns/ Raf 12 MEMBER 8 A325 5/8" 1 3/4 4 A325 1/2" 1 1/4 2 A325 1 /2" 1 1/4' EC -2 W8X10 12"-2 13/16;; EC -3 W8X10 12-2 13 16 EC -5 W8X10 11'-5 5 8 EC -6 W8X10 11'-5 5/8" ER -3 W8X10 18'-1 1/8" ER -4 W8X10 18'-1 1/8" DJ -2 8F35C14 12'-4 13/16" DH -1 8F25C16 12'-0" G-3 8X25Z16 8'-6" G-4 8X25Z16 1'-4 1/4" CB -4 1/2 DIA. ROD 11'-11 CB -5 1/2" DIA. ROD 10'-2" CB -6 1 2" DIA. ROD 10'-5" FLANGE BRACE TABLE FRAME LINE 4 D ID PART LENGTH FB29.5 L2X2X14G 2'-5 1/2" FB6-1 I L2X2X1/8" 1 2'-5 1/2" CONNECTION PLATES FRAME LINE 4 ❑ ID MARK PART 1 SC -5 2 PC30-1 12 BY CK'D DSN GENERAL STEEL CORPORATION PNR PNR AJL 10639 W. BRADFORD RD PHONE : 800-406-5126 LITTLETON, CO 80127-4208 FAX 303-979-0084 PROJECT: M21350 — CHASE PEARL CUSTOMER: VANGUARD OPERATING LLC OWNER: VANGUARD OPERATING LLC LOCATION: NEW CASTLE, CO 81647 CAD DATE SCALE PHASE BUILDING ID JOB NUMBER SHEET NUMBER ISSUE 7/13/17 N.T.S. 1 A 15-B-88709 E6 A Jul 19, 2017 1M;