HomeMy WebLinkAboutPlansGENERAL NOTES GENERAL 1. Design Criteria: / a. Code: 201518CV b. ASCE 7 Building Occupancy Category 11 c. Design Roof Snow Load Pf=60 psf d. Seismic Design Category "C", Site Class "D" e. 3 Second Gust Wind Speed115 mph, Exposure B 2. Work shall be performed in accordance with regulations of all agencies having jurisdiction, including, but not limited to: Federal, State, County, and OSHA standards. 3. Dimensional information provided is for reference and check purposes only. The Contractor shall coordinate all dimensions among these documents and verify all field conditions. Any discrepancies encountered that may affect the work shall be communicated to the Engineer at the earliest prior to proceeding with any work that may be affected. 4. The Contractor is responsible for all bracing and shoring for vertical/wind/seismic/soil retention loads, shoring and protection of adjacent property, temporary construction, and means that may be required to carry out the work safely and appropriately. Field observations by the Engineer shall not encompass these considerations. 5. Where discrepancies may be encountered in the construction documents, the more stringent requirement shall govern unless otherwise clarified by the Engineer. 6. The Contractor shall coordinate all soils/meterials testing and special inspections including concrete compressive strength and structural steel bolting and welding. 7. Engineer's acceptance must be secured in advance for all structural deviations or substitutions. 8 These documents are intended to complement the Architectural documents and shall not be used independently thereof. 9. These documents are intended for the exclusive use of this project. The use of these documents for any other purpose is not authorized. Written authorization from Glenwood Structural and Civil, Inc. must be obtained for any other use. This document is to be used within one year of the date of preparation. Use after that period is not authorized. LOCATION MAP CONCRETE 1. Any verification of existing conditions required on the drawings is to be performed at the start of construction. The Engineer shall be notified of confirmation of the required verification items or discrepancies therein in a timely fashion in order that the modifications may be made appropriately. 2. Concrete compressive strength (Fc) shall be 5,000 psi at 28 days. Aggregate shall conform to the requirements of ASTM C-33. Maximum fly ash content in cementitious material shall be 20%. Maximum slump at the truck discharge point shall be 6". Air content shall be in accordance with local industry standard practice. Waterproofing maybe achieved with Hycrete W502 admixture or pre -approved equal. Novomesh 950 maybe used for additional shrinkage protection and shall be applied at a minimum rate of 5lbs. per cubic yard or additional as pre -approved. 3. Adhesive anchors shall be Hilti HY150, Simpson Set XP, Ramset/Red Head Epcon A7, or Power Fast. These shall be of the depth indicated and shall be installed in accordance with the manufacturer specifications. 4. Expansion Anchors shall be Hilti Kwik Bolt 11, Simpson Wedge -All, Ramset/Red Head Trubolt, or Power Stud. These shall be of the depth indicated and shall be installed in accordance with the manufacturer specifications. Special Inspection shall be provided where specifically noted on the drawings. 5. Reinforcing steel shall be high strength deformed bars in compliance with ASTM A-615. Yield strength (Fy) shall be 60 ksi. 6. Submit fabrication drawings for footing and wall reinforcement prior to fabrication. Steel shall be detailed and installed in accordance with the latest editions of ACI 318 and the ACI Detailing Manual. 7. Unless noted otherwise, clear distance to reinforcement for placement against earth shall be 3" and clear distance to reinforcement for placement against forms shall be 2" for bars #6 and greater and 1-1/2" for bars #5 and smaller. 8. Splices in reinforcement shall not be made unless otherwise detailed herein or previously approved on the fabrication drawings. Unless noted otherwise or prohibited, lap length of reinforcement steel shall be 32 db (bar diameters). Continuous reinforcement in beams and walls shall be spliced at midspan for top bars and over supports for bottom bars. 9. Provide a minimum of 245 bars at all jambs, heads, and sills of openings as well as all top and bottom of walls, top of wall steps, top of grade beam stems, bottom of wall steps and bottom of grade beam steps. 10. All exposed concrete edges shall have a minimum of 3/4" chamfer or 1/2" tooled round unless noted otherwise 11. Reference Architectural drawings for non-structural concrete. SOLVAY PUMPHOUSE ENCANA GATE HOUSE t 90 0 M M CR 215 BATTLEMENT PARACHUTE MESA LEGEND T.O.S. TOP OF SLAB ELEVATION T.O.F. TOP OF FOOTING ELEVATION T.O.W. TOP OF WALL ELEVATION U.N.O. UNLESS NOTED OTHERWISE C.J. CONTROL JOINT CLR. CLEAR ABV. ABOVE (E) EXISTING (N) NEW V.I.F. VERIFY IN FIELD ADH. ADHESIVE SHEET INDEX S1 GENERAL NOTES, LOCATION, LEGEND, INDEX, DETAILS S2 PLANS & ELEVATIONS SITE MAP AE SIf',IECT TO NOTED EXCEPT;ONS & INSPECTIONS GAr, FIE LD COLiNil i y BU!'"N'UEPA, N DATEI 1 FIELD COPY NO INSPECTION WITHOUT THESE PLANS ON SITE Page Of Roof slope `--Re: plan Long Direction (Upper) Reinf. per plan Short Direction (Lower) Reinf. per plan Roof slab, see plan I OL 108'-0 T. 0. (E) WALL �1 1/2" #5 dowels @ 24" O. C. into (E) CMU wall w/ Simpson SET Adhesive embedded 5" MIN. Bend dowels to provide 12" MIN horiz. leg over wall. Do not bend in direction perpendicular to wall, 8" CMU wall HIGH END SLAB TO WALL CONNECTION 1 SCALE: 1'=1'.0' S1 (N) Roof slab, see Provide cont. notch in bottom of slab - 10 T-4 lab107'-4 JN T.O. (E) WALL #5 dowels @ 24" O. C. See Detail 1/S1 (E) 8" CMU wall Roof slope `Re: plan Long Direction (Upper) Reinif per plan Short Direction (Lower) Reint per plan _ _ LOW END (N) Roof slab, see 107'-4 T.O. (E) WALL #5 dowels @ 24" O.C._ See Detail 1/S1 (E) 8" CMU wall SCALE: 1"= 1'-0" Short Direction (Lower) Reinf. per plan Long Direction (Upper) Reinf per plan _SIDE WALL MC12x10.6 (or equiv.) w/ 112"x 4" H.A.S. @ 16" Sealant, by others Waterstop, by others Add'I reinf., per plan Terminate reinf at opening w/std hook, TYP. Concrete roof slab, per plan SCALE: 1"= V-0" OL Prefab roof hatch, by others SCALE: 1"= 1'-0" These documents are intended for the exclusive use of the project specified below. The use of these documents for any other purpose is not authorized. Written authorization from Glenwood Structural and Civil must be obtained for any other use. This document is to be used within one year of the date of preparation. Use after that period is not authorized. KUERSTEN CONSTRUCTION SOLVAY PUMP STATION #2 GARFIELD CO. COLORADO GENERAL NOTES LOCATION, INDEX LEGEND & DETAILS Scale: AS NOTED Date Description 10/4/16 Permit/Construction rl e71g0IVi1NZ0U 71:�R�11�1:�G1 q �I�Z�l1�I1�1►C a' ers E ncjweer5. Con5tructor5 81 2 Pitkin Avenue Glenwood 5pring5, CO (970) 928-0135 Fax 928-9804 Job Number 16500 Designer/Drafter AG/KK Engineer AG Date 10/4/16 S1 = F m � o � cCU n n m CU o s o m = F-1 a m rnn' G7 ca Q7 N n y r F7 m n o m 373 y [a C9 LD m n � O d n c s , m m � cn cn (N) CAST -IN-PLACE CONCRETE ROOF SLAB (E) CMU WALLS (E) CAST -IN-PLACE STEM WALL & FOOTING 4 SOUTH ELEVATION S2 ---------------------------------------- I I I I — — — ----------------------------------- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I (E) 8" CMU WALL I 97'-4 SOLID GROUTED I t I I I I I (E) T.O. STEM WALL i I (E) SLAB -ON -GRADE I I (E) 10" WIDE STEM WALL ELEV. 100'-0 I I I I I (PUMP & EQUIP. NOT SHOWN) 1 I 97'4 t I 1 I (E) T.O.F. I I I I I I (E) 20" WIDE x 12" THK FTG I I I I I I I I I I I I I I I I 1 I I I i I I I I I I I I I I I I I I I I I I I I IL -----------------------------------------------t I I I I L --------------------------------------------------------J 21 EXISTING FOUNDATION S2 I SCALE: 1/2"= 1'-0" PLAN O Lu (X (X2m ti cr O h ?amu, W¢m + Q o@!5 z (N) CAST -IN-PLACE CONCRETE ROOF SLAB (E) CMU WALLS (E) CAST -IN-PLACE STEM WALL & FOOTING (N) 6" CAST -IN-PLACE ROOF SLAB W/ REINF AS SHOWN MID DEPTH SLOPE TO DRAIN I� 107'-4 (E) MASONRY T.O.W. WEST ELEVATION REINFORCEMENT IN SHORT DIRECTION: #4 @ 12 + ADD'L BARS SHOWN (PLACE BELOW LONG BARS) `t 3 o O 2 2 S1 � w HOOK BARS WHERE SHOWN THUS 1 s1 3'-4"3 — 2 * 5'-4"t (E) VENT 16'-8" (E) O ROOF STRUCTURE PLAN S2 0' 2' 5' SCALE: 112"= V-0" 107'-4 R (E) MASONRY T O. W 10' r1olp1hr These documents are intended for the exclusive use of the project specified below. The use of these documents for any other purpose is not authorized. Written authorization from Glenwood Structural and Civil must be obtained for any other use. This document is to be used within one year of the date of preparation. Use after that period is not authorized. KUERSTEN CONSTRUCTION SOLVAY PUMP STATION #2 GARFIELD CO. COLORADO PLANS 8� ELEVATIONS Scale: AS NOTED Date Description 10/4/16 Permit/Construction e1Ii4i0 �L•I•]. ' 71NR�l11J:r�1 sla Engmeer5. Constructors 81 2 Pitkin Avenue Glenwood 5pnng5, CO (970) 928-0135 Fax 928-9804 Job Number 16500 Designer/Drafter AG/KK Engineer AG Date 10/4/16 S2 TO IS BAR (TYP) EA EDGE OF OPENING HOOK BARS WHERE SHOWN THUS 1 s1 3'-4"3 — 2 * 5'-4"t (E) VENT 16'-8" (E) O ROOF STRUCTURE PLAN S2 0' 2' 5' SCALE: 112"= V-0" 107'-4 R (E) MASONRY T O. W 10' r1olp1hr These documents are intended for the exclusive use of the project specified below. The use of these documents for any other purpose is not authorized. Written authorization from Glenwood Structural and Civil must be obtained for any other use. This document is to be used within one year of the date of preparation. Use after that period is not authorized. KUERSTEN CONSTRUCTION SOLVAY PUMP STATION #2 GARFIELD CO. COLORADO PLANS 8� ELEVATIONS Scale: AS NOTED Date Description 10/4/16 Permit/Construction e1Ii4i0 �L•I•]. ' 71NR�l11J:r�1 sla Engmeer5. Constructors 81 2 Pitkin Avenue Glenwood 5pnng5, CO (970) 928-0135 Fax 928-9804 Job Number 16500 Designer/Drafter AG/KK Engineer AG Date 10/4/16 S2