July 25,2018
Mike Brown
I262Caunty Road 112
Carbondale, Colorado 81623
Downtown.brown @ mac.com
Project No. l8-7-141
Subject:Observation of Excavated Pits, Proposed Shop, 1262County Road 112, Garfield
County, Colorado
Dear Mike:
As requested, a representative of H-P/Kumar observed the excavation at the subject site on July
18, 2018 to evaluate the soils exposed for foundation support. The findings of our observations
and recommendations for the foundation design are presented in this report. The services were
performed in accordance with our agreement for professional engineering services to you, dated
February 2,2018.
The proposed shop will be a metal frame/metal skin building with spread footing foundation and
slab-on-grade floor.
At the time of our visit to the site, four exploratory pits had been excavated near the four corners
of the proposed shop location from 6 to \Vz feet below the adjacent ground surface. The soils
exposedinthebottomof theexcavation,belowabout l footof topsoil,consistof 3to íVzfeetof
sandy clay overlying sand and gravel with cobbles. Results of swell-consolidation testing
performed on samples taken from the site, shown on Figures 2 ro 4, indicate the clay soils have
low to moderate compressibility under conditions of loading and wetting. The results of a
gradation analysis performed on a sample of sand and gravel (minus 3 inch fraction) obtained
from the site is presented on Figure 5. No free water was sncountered in the excavation and the
soils were slightly moist to moist.
Considering the conditions exposed in the excavation and the nature of the proposed
construction, spread footings placed on the undisturbed natural soil designed for an allowable
soil bearing pressure of 2,000 psf should be adequate for support of the proposed shop. The
exposed soils tend to compress when wetted and there could be some post-construction
settlement of the foundation if the bearing soils become wet. Footings should be a minimum
width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils in
footing areas should be removed and the bearing level extended down to the undisturbed naturâl
soils. Exterior footings should be provided with adequate soil cover above their bearing
elevations for frost protection. Continuous foundation walls should be reinforced top and bottom
to span local anomalies such as by assuming an unsupported length of at least 12 feet.
Mike Brown
July 25, 2018
Page2
Foundation walls acting as retaining structures should also be designed to resist a lateral earth
pressure based on an equivalent fluid unit weight of at least 45 pcf for on-site soil as backfill.
A perimeter foundation drain should be provided to prevent temporary buildup of hydrostatic
pressure behind retaining walls but should not be needed for the proposed slab-on-grade floor
level near exterior grade. Structural fill placed within floor slab areas can consist of the on-site
soils or a suitable imported gravel compacted to at least 95Vo of standard Proctor density at a
rnoisture content near optimum. Backfill placed around the structure should be compacted and
the surface graded to prevent ponding within at least l0 feet of the building. Landscape that
requires regular heavy irrigation, such as sod, and sprinkler heads should not be located within
10 feet of the foundation.
The recommendations submitted in this letter are based on our observation of the soils exposed
within the excavated pits. This study is based on the assumption that soils beneath the foıtings
have equal or better support than those exposed. The risk of foundation movement may be
greater than indicated in this report because ofpossible variations in the suhsurface conditions.
Our services do not include determining the presence, prevention or possibility of mold or other
biological contaminants (MOBC) developing in the future. If the client is concerned about
MOBC, then a professional in this special field of practice should be consulted.
If you have any questions or need further assistance, please call our office.
Sincerely,
H-P+KUMAR
James H. Parsons, E.I.
Reviewed by:
Daniel E. Hardin,
JHPlkac
attachments Figure - Logs of Exploratory Pits
Figure 2to 4 - Swell-Consolirlation Test Results
Figure 5 - Gradation Test Results
Table 1 - Summary of Laboratory Test Results
Project No. 18-7-141
e
t
E
PIT 1
11.100'
PIT 2
81.94.5'
PII 3
EL. 97.5
Prï 4
EL. 1 00'
0 0
FLJ
Lrll,!
I-Fo-
LTJâ
WC=8.8
DD=89
WC=1 1.3
DD=BZ
Þ-r¡JtJ
l!
IIF
o_
LIô
5
-l WC= 1 2.5
-r *4=65
_1nn-tr
NP
5
WC= 13.5
DD=82
I0 10
LEGEND
TOPS0IL; SANDY cLAY, ORGANIcS (ROOTS), ME0IUM STIFF, SLIGHTLY MOtST, BROWN.
CLAY (CL); SANDY TO VERY SANÐY, MEDIUM STIFF, SLIGHTLY MOIST, CALCAREOUS WITH
DEPÏH, BROWN 10 TAN.
GRAVEL AND SAND (CT-SN); COBSLES, SCAITERED BOULDERS, CALCAREoUS, SASALT GRAVEL,
WHITE TAN, SLIGHTLY MOIST.
F HAND DRIVEN LINER SAMPLE
l.'
D¡STURBED BULK SAMPLE
NOTES
.I. THE EXPLORATORY PITS WERE EXCAVATEÐ WITH A BACKHOE ON JULY 15,2018
2. THE EXPLORATORY P|TS WERT LOCATED BY THE CLIENT.
3. THE ELEVATIONS OF THE EXPLORATORY PITS WERE ESTIMATED AND REFER TO THE PIT 1 AS A
IOO, BËNCHMARK.
4. ÏHE EXPLORATORY PIT LOCATIONS AND ELEVATIONS SHOULD BE CONSIDEREO ACCURA]E ONLY
TO THE DEGREI IMPLIED BY THE METHOD UsEO.
5. THE LINES BETWEEN MATER'ALS SHOWN ON THT EXPLORÄTORY P LOGS REPRËSTNT THE
APPROXIMATE BOUNDARIES BETWEEN MAIERIAL TYPES AND THE TRANSITIONS MAY gE CRADUAL.
6. GROUNDWATER WAS NOT ENCOUNTTRED IN THE PITS AT THE TIME OF DIGGING. PITS WERE
BACKFILLEÐ SUBSEQUENT TO SAMPLING.
7. LABORATORY TEST RESULTS:
WC = WATER CONTENT (%) (ASTM D 2216);
f]D = DRY I];NSITY (PCT) (ASTM D ?216);
+4 = PËRCENTAGE RETAINEO ON NO. 4 SIEVE (ASTM D
_ZOQ = PERCENTAGE PASSING NO. 2OO SIEVE (ASTM D
NP = NON-PLÀSTIC (ASTM Ð 4518).
a22);
1 1 a0);
18-7 -1 41 H-PryKUMAR LOGS OF TXPLORATORY PITS Fí9. 1
SAMPLE OF: Scndy Cloy
FROM:8oring2u^7.5'
WC = 13.5 %, D0 = 82 pc{
ADDITIONAL COMPRISSION
UNDIR CCINSTANT PRESSURT
DUE TO WETTING
I | -"/
\
I )
S*.Ìl
JJ
L¡l
U1
I
zotr
ff:
tnz.a
0
_t
-2
_Ì
*4
-J
-6
ÂPPL'€D PRISS - KSF 10 100
18-7 -1 41 H.PVKUMAR SWELL-CONSOLIDATION TTST RTSULTS Tí9. 2
¡
6
:I
Ê
E
SÀMPLE OF: tloyey Scnd
FROM:Boring3@3.5'
WC = 8.8 %, ÐD = 89 pcf
AÛDITIONAL COMPRESSIÕN
UNDTR CONSTANT PRTSSURT
DUT TO WËTTINö
)
\
I
\
\)
lhcs. t¿¡l r.r¡¡t! ûqpìy a¡ly lE t¡!
!!nrp¡c! lé!t¡d. th. t!!!ùq .troi
.hall ro! !! rêpmdlcld, ar.lpl in
l!,1, rilhou! lhc dllen opp'ð!01 ot(!no¡ ¡nd &3ocìol.s, l¡c- slcli
:oôloi;úolio¡ llii.g pcd.m.d in
cccôrdô¡.. sÌlh ASru 0-4548.
iljl
il
)J
ttJ3
¡
z"(}ç
:
v7z.
(-)
at
*2
-4
-6
*8
*10
'tz
1.û - Ksf 10 100
18-7 -1 41 H.PryKUMAR SWTLL-CONSOLIDATION TEST RTSULTS Fig. 3
SAMPLE 0F: Sondy Ölny
ËROM: Boring4@5'
WC = 11.3 %, DD = BZ pcf
lj
t;
ADDITIONAL COMPRESSION
UNDER CONS'ANI PRESSURT
ÞU[ TO WHTTING
I
(\
)
ftr!. ilel tclull! oppç o¡ly t th..ompl!! t..ld. lñ! l.rt'¡q rqd
lhorl not b! r.rroouc¿d,6ic¿ir iñf!ll, iilfoll th. rdtl.n opp,oror or
Kum¿r o¡d &rociot.3. r¡c. St.ll
Con.olìdotan 1rdì¡9 r4¿snd íô
oicôrdô¡c€ yith ÀS* 0-.51ô.
APPLIEO _ KSF 10 t0û
0
ñ
JJ
L¡l3tn
I
zotr
c:
tnz(f
(J
-1
-2
-1
-4
-6
-8
18-7 -1 41 H-PryKUMAR SWELL_CONSOLIDATION TEST RTSULTS Fig. 4
¡
t
SIEV' ANÁLYSIS
u,s. gÄtÐâRo CLÊÂR SOUAi€ OP€I¡NCS
3l¿" t/a' 1 t/.â
-+
HYDROM€IER ANÂLYS'S
a
ro0
90
80
70
60
50
40
l0
20
fo
o
o
to
20
!o
40
60
70
a0
90
too
a
Ê
.a2s
PARTICLES IN M'LLIM
CLAY TO S¡LT COBBLES
GRÂVEL 65 % SAND 30 %
LIQUID LIMIT PLASTICITY INOCX
SAMPLE 0F: Sqndy Grov€l snd Coþblss
SIL1 AND CLAY
NP
3%
FRoM: Borlng 1 O 4.5'-5,5'
lha¡c l¡rl rcsults opply on¡y lo lhrsomp¡.! wh;ch w€re lo9l6d. Íh6ksling rcport sholl nol ba r.producrd,.rc.pt In lull. wllhoul lh. wrlfl.n
opp.oyol of l(lmor & Aelocioks, lnc.SLvc onolysfr lasl¡ng Is prrtorñad ln
occordoñc. wllh ÀSlM 0422, ASTM C136andlor ÂSTM 0t t40.
SAND GRAVEL
FINE MEDTUM lCOlnSe flNf coARsr
18-7 -1 41 H-PryKUMAR GRADATION TIST RTSULTS Fig. 5
H.PIKUMARTABLE 1SUMMARY OF LABORATORY TEST RESULTSProject No. 18-7-141SOILTYPESandy Gravel and CobblesSandy ClayClayey SandSandy Clay12.56s305NPUNCONFINEDCOMPRESSIVESTRENGlH(psfìiRG L¡MITSPLASTICINDEX(%lATTERBLIQUIDLIMIT(%lPERCENTPASSINGNO.200SIEVEGRADATIONSAND%lGRAVELØlNATURALDRYDENSITY(ocf)828982NATURALilOISruRECONTENTlo/"113.58.811.3SATIPLE LOCATIONDEPTHtfrt4Vz-sYz7Y23Vz3PITI234