Loading...
HomeMy WebLinkAboutPlansDESIGNER/ENGINEER: S -arch E.D.ENCK, P.E. 3001 Brighton Blvd Denver, Colorado 80216 PH. 303-455-4117 CL: 303-910-6778 email: ed@s-arch.com CONDITIONS OF PERMIT BLCO-9-15-3925 Rocky Mtn Gas/Public Srvc Co. of CO Compressor Bldg. @ 1861 CR 264 Rifle, Colorado 1) ALL WORK MUST COMPLY WITH THE 2009 IBC AND MANUFACTURERS SPECIFICATIONS. 2) ALL WORK MUST COMPLY WITH STATE AND FEDERAL REGULATIONS. 3) ALL WORK MUST COMPLY WITH THE CURRENT LAND USE CHANGE PERMIT. 4) PRIOR TO CONSTRUCTION, CONTACT LOCAL FIRE DISTRICT FOR PERTINENT IFC REQUIREMENTS. FIRE DISTRICT FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION. 5) OPEN -HOLE SOILS REPORT REQUIRED AT FOOTING INSPECTION, TBD PSF. 6) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION. 7) LIGHT AND VENTILATION PER 2009 IBC, CHAPTER 12. 8) LOCKS, LATCHES AND LANDINGS PER 2009 IBC, SECTION 1008. 9) GARFIELD COUNTY FINAL INSPECTION REQUIRED FOR COMPLETION APPROVAL. Drawing List - - - Sheet Sheet Name Number Cover Page & Code Review A0.0 A2.1 Floor Plans, Typical Section & Door Schedule Elevations, Vent Callas, Door Schedule & Ventilation Calcs A3.0 Foundation Plan & Details S1.0 Tank Slabs S1.1 Steel Frame Details 1 S1.2 Steel Frame Details 2 S1.3 Steel Frame Details 3 S1.4 Steel Frame Details 4 S1.5 Steel Frame Details 5 S1.6 Steel Frame Detals 6 S1.7 Steel Frame Details 7 S1.8 Steel Frame Details 8 S1.9 Steel Frame Details 9 S1.10 Steel Frame Details 10 S1.11 Structural General Notes S2.0 PROJECT DATA : CONSTRUCTION TYPE: II -B OCCUPANCY: U USE: Air Compressor Enclosure SIZE: 300 SF (Gross) NO. of STORIES- 1 LOCATION: Rifle, Colorado PROJECT SCOPE: 1 Story Steel Structure w/ Steel Truss roof and metal roofing on Cast -in -Place Monolithic Concrete Foundation. Structure is used to house an air compressor and associated equipment. FOR: LOgCAI. 9YSTl7AS. LLC 11RTLETT, M'tOla77'-1i74 G�]I m. 303P1399� TGA �� 9S0 fiU"zHUU CKIA B6MM03M& 574 VWLE0CALSYiD'IC,CDI Building Codes: 2012 International Building Code 2012 International Energy Conservation Code 2012 International Plumbing Code Specifications and Standards This project will adhere to the following standards latest editions: • PSCo Gas Engineering Handbook — Pressure Regulating Stations Best Practices • Xcel Energy Pipeline Compliance & Standards Manual • Title 49 CFR Part 192 • AGA XL1001 —Area Classification Xcel Energy Handbook of Corporate Safety Policies • International Building Code (IBC) • NEC National Electrical Code • All state and local codes as applicable Steel Frame ISO See. ��/d�jdyCS 3 Cover View _ TABLE R301211) - CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA APPROVED SUBJECT TO DOTED EXCEPTIONS & INSPECTIONS GARFIELD COUNTY �l_)9LnI lr Dt_t'=:r: F IG DA i I �O�j' F Y — ",;`='YNO :;i ----- Building Codes: 2012 IBC CODE REVIEW ITEM DESCRIPTION Project Scope 1 Story, Type II -B Structure - 300 SF total - Gross SF CHAPTER 3 USE AND OCCUPANCY TYPE Table 1004.1.1 Sec. 1005 Occupancy Type: Occupancy to be U /Utility Sec. 1008.1.1 Sec. 1008.1.2 Sec. 1009.1.6 (Structure housing Air Compressor and assoc Equipment) CHAPTER 4 SPECIAL REQUIREMENTS BASED ON USE AND OCCUPANCY NONE CHAPTER 5 BUILDING HEIGHTS AND AREA Height /Area Requirements: Allowable increase OK - Type 11-B and U Occupancy permits 2 story - 8, 500 SF None required area Separated Occupancies None. No Sprinkler System required by Chapter 5 - due to area or ht. Special Provisions: None found CHAPTER 6 TYPES OF CONSTRUCTION Type of Construction: (Non -Comb Construction) Type II -B Fire -Resistance Structural Frame 0 Hr Requirements for Bearing Wall (Ext) 0 Hr Building Elements: Non and bearing Walls (Int) 0 Hr Nonbearing Walls (Ext) 0 Hr Floor Construction 0 Hr Roof Construction 0 Hr Fire -Resistance Fire Sep distance greater than 10' no exterior wall fire rating required Requirements by Note.- if Fire Separation distance is less than 10, then 1 HR ext. walls are required Fire Sep Dist Fire Sep dist on all sides of structure is greater than 10 ft. Therefore unprotected doors and windows are permitted CHAPTER 7 FIRE -RESISTANCE -RATED CONSTRUCTION Openings. Side wall Fire Sep Dist is greater than 30' therefore unprotected (UP, NS) openings to are permitted Unlimited unprotected transfer grills permitted per. Parapets: Not required where exterior walls are not required to be fire rated or if building is less than 1000 SF Shaft Enclosures None CHAPTER 8 INTERIOR FINISHES See Chapter 8 for allowable of interior finishes - Spec Int Paint permitted CHAPTER 9 FIRE PROTECTION SYSTEMS Sprinkler System: Auto Sprinkler System not required by Allowable SF or Ht's. Allowable Building Areas and Ht's not exceeded Alarm System: None Required CHAPTER 10 MEANS OF EGRESS Occupancy Loads Mechanical Equipment room requires 300 SF per Occ 360 Gross Bldg SF /300 SF per Occ. = 2 Occupants TOTAL OCC =2 OCCUPANTS Egress Width: 36" Min. Doors: Min Exit Door width = 36' Exterior Door may swing in either direction w/ Occ Load less than 50. Landings: Provide Landing - 44" min in length and 36" wide Dead Bolts: Not permitted Panic Hardware: Not Required w/ Occupant load less than 50 Exit Signage: Not required when only one exit is required # of Exits 1 required w/ Occ Load less than 50 (U Occupancy) travel distance less than 75' and Travel distance = 30' OK CHAPTER 11 ACCESSIBILITY Not required since access is limited to maintenance, repair and monitoring personnel only. CHAPTER 13 ENERGY EFFICIENCY Structure is heated and insulated CHAPTER 29 PLUMBING SYSTEMS Restrooms not provide in temporary use facility Compressor Room I 5343.3' � �W� Z N W I -- all J 15'_0" 1 E)dt Plan 15'-0" Compressor Room 5343.3' 0 Area 300 SF r,-\ 1 st Floor Areas 1/8" =V_Gr Table 503 Sec. 506 Sec. 508 Sec 509 Table 601 n Table 602 O Table 705.8 Sec. 705.10 705.11 Except. 1 Eq m 171 CV3 c Sec.2902.1 u7 3 IT Cn G Q] c G Ed C-3 en J G M I.— C3 r' C=71 E o C13 M 0 C%J m cEL C3_ es LSI# _ 15781 V a r lain ■ 3001 Brighton Blvd. Ste. 457 Denver, Colorado 80216 303-455-4117 z Q Z �m O a�U p a� Q Cl) C� Lu LLJ W mialla IL 2 w O U �AGIS Tz'y O. � EtyC• n :w 0D .w ss 9/21/15 Copynght 0 2015 Samh All rgha reserved. No pan or mase ao=,mento may be repmduoed in any form or by any means x or when permisson fiom Sa h ISSUE 1 -.Submittal for LSI 9/14/15 Review 2 For Construction 9/21/15 NO. DESCRIPTION DATE DRAWING TITLE: Cover Page & Code Review DRAWING NO: AOmO SCALE: 10= V-0" DATE: 9/14/15 PROJECT NO: LSI -33-0120 DES. DRWN. CHK'D. EDE INDE I EDE Table 503 Sec. 907.2 ` Table 1004.1.1 Sec. 1005 14 Sec. 1008.1.1 Sec. 1008.1.2 Sec. 1009.1.6 O Sec. 1008.1.9.4 Sec. 1008.1.10 Sec. 1011 Sec. 1021.2 Sec.1103.2.9 Eq m 171 CV3 c Sec.2902.1 u7 3 IT Cn G Q] c G Ed C-3 en J G M I.— C3 r' C=71 E o C13 M 0 C%J m cEL C3_ es LSI# _ 15781 V a r lain ■ 3001 Brighton Blvd. Ste. 457 Denver, Colorado 80216 303-455-4117 z Q Z �m O a�U p a� Q Cl) C� Lu LLJ W mialla IL 2 w O U �AGIS Tz'y O. � EtyC• n :w 0D .w ss 9/21/15 Copynght 0 2015 Samh All rgha reserved. No pan or mase ao=,mento may be repmduoed in any form or by any means x or when permisson fiom Sa h ISSUE 1 -.Submittal for LSI 9/14/15 Review 2 For Construction 9/21/15 NO. DESCRIPTION DATE DRAWING TITLE: Cover Page & Code Review DRAWING NO: AOmO SCALE: 10= V-0" DATE: 9/14/15 PROJECT NO: LSI -33-0120 DES. DRWN. CHK'D. EDE INDE I EDE I' 2'-31/2" C 0 T-81 /2" i T-0 5/8"-13/8" o m o � (V - O - 3'- 41/4' GREENHECK, DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTFAN, MODEL CW -161-B FINISHED — 2., ' • GRADE 5342 80' 2'- 0" • S; -o Civil Elevation 5343.3'= ' Arch Elevation =100'-0" - Section 3 — Classic Rib by Metal Sales #W50, 'Carlsbad Canyon Tan', 24 gauge I I I I II I I I roprrlem 0 2015 s h All rams raaanraa. No Part W there d nian6 -Y ba rapivaiced in any man or by any means wdic;M wrilEan parmselon from Sarch - PVDF (Kynar 500). ForConstruotion 921/15 — Provide Avalanche Clips above all � J gutter locations �m T.O.W. O a� 108'— 0"u O = — Provide OG Profile 4" Gutter Length to cl) 1.1� 0 above door. match landing width below. m W — Rigid Polyisocyanurate Insulation 0 Exterior siding shall be Propanel II by 20 Metal Sales #10, "Carlsbad Canyon N Tan", 26 gauge PVDF (Kynar 500) -- (Interior siding shall be Propanel II by Metal Sales LL #80, 'Polar White', 29 gauge PVDF (Kynar 500). 0 Y Q U � Q FB6x1/2 - CONTINUOUS O AROUND PERIMETER. (n U o T.O.W. to FOUNDATION N m 100'- 0"u m FINISHED GRADE 5342.80' C cm Lo�S, G�t�r�s �G�Jrc✓iKyS Ke�Notes / - yrr Zor/? z,3 if # Description 1 C11� ALL SLABS TO BE A MINIMUM OF 10" THICK ifstd Von Duprin 98 -Series Exit Rim Devicep` The Von Duprin 98 -Series Exit Rim Devices is the modern touchbar styling for heavy traffic applications. - Select Function: 98EO (Exit Ont No Trim), 98DT (Dummy Trim), 98NL (Nightlatch Trim), 98TP (Thumbturn Trim), or 98L (Lever Trim) - Select Finish: Anondized Aturninum or Satin Chrome (26D) - Select Device: Rim Device (Standard) or Fire Rated Rim Device (F) - Select Device Length:F3 Feet (3') jor 4 Feet - Delivery: All Von Duprin is factory -ordered, please allow 4-5 business days lead time. 98L -F US26D 3RHR 996/US26D 06 D1 D1 Overhead -Sectional: 8'x 6'-6" 8' - 0" 61-89, 1 D2 D2 Single -Flush: 36" x 80" 1 Hr - Insulated Metal Door - 3' - 0" 61- 8" Cunies 707 series standard foam core, 14 Provide Security Hinges, Panic Hardware, and a Lever 2 Metal Frame ga. hinge and lock channel, 16 ga top and Lockset compatible With Xcel keying system bottom end channel, 18 ga face skin PAINT TO MATCH ROOFING COLOR. Provide 4040XP CLOSER AND RELATED HARDWARE, WEATHER-STRIPPING, KICK- DOWN STEEL DOOR STOP, FULL SS Xcel/LSI TO PROVIDE Cal -Royal part # 308-602 with US26D finish with Best /Falcon part # 7PCC- KD, small format 6 pin "A" keyway, combinated KD interchangeable core mortise and rim lock -set assembly. 4 A2.1 15'- 0118" 15'-0" 101/4 V-5. 7'1' -1 7!8" 11-9. T - 7" 1'- 0 1/4" 2'- 11 718" V- 4 7/8" k le iv I II II II II II II II II II II II II II m EDGE OF ;; ;; N FND. o I I I I I I I I ( V �1 II II 11 EDGE OF BASE FRAME! II II II II NV II II II II II II II II -- -_ ---��--------------rr-----Y7--------------rr---! ---- ---- p 1 II II II II tl II II ' 0 II II II II II II II II II II II II m II II II II N I II it II I 42" x 42" Vent w/ Louver i i ! ! ! ! II II 11 and Screening 11 II 11 � li II II 11 II II II II ! ! (Compressor RoorW I ! II II II II !! !! 5343.3' !I 11 II 1 11 _y1______________LL------------- 11 -------------- L� -_______ ------ -_-_______________11-_______--____LF-_____ I II II II II II II II II II II 11 -- ----I�-----------rr------------r7 ----------rj ----- -- ---- r II II II II II II II II - I, II II II II II II 11 II II II II II II II II g !! !! 14,_8„ I � II 71 II II N ! ! GREENHECK, DIRECT ! N j DRIVE CENTRIFUGAL ! ! I SIDEWALL EXHAUSTFAN, I ! ! ! ! MODEL CW -161-B II I 11 II it -__ TIII TIII ______-___ _rI1LII _________ ___- -____ _ 2'-83/4" !I 2'-83/4" I I 2'-8314" 7-8314" 2'-8314" ! RIVETED DOOR I 1 1 I I TRIM TO MATCH I I I I INTERIOR WALL ! SIDING MATERIAL ! ! II �I II II II II 11 II C !i ii 14'-10" N I I I I 8' - 6 1/4!' I II II I __________________ tV 3, 4" V-0. 3,_4.. 1' - 5" 7' 1' - 5" 7 4--0" 1'- 4 1/4" 2'- 9 3/4" V-5- 7' V - 5" 01 01 VV I10K 11 4101 / 3 2" 7r_Bn T-6" b 7-10" ED 5'-0" 5'-0" 01 7-10" 01 10 1s' -a' 151-91 101-01 1/2" = 5'X4' - 10" Thick Conc. Slab, Slope 1/4" per Ft. CID 8'X10' - 10" Thick Conc. Slab, Slope 1/8" per Ft. I 3001 Brighton Blvd. Ste. 457 Denver, Colorado 80216 303-455-4117 Ery�R� ss�`jPyJ 9/21/15 I I I I II I I I roprrlem 0 2015 s h All rams raaanraa. No Part W there d nian6 -Y ba rapivaiced in any man or by any means wdic;M wrilEan parmselon from Sarch I.L z ForConstruotion 921/15 � J Z� �m O a� ) O = a cl) 1.1� 0 W W W iiiiiiiiiiiija L 20 V Ery�R� ss�`jPyJ 9/21/15 I I I I II I I I roprrlem 0 2015 s h All rams raaanraa. No Part W there d nian6 -Y ba rapivaiced in any man or by any means wdic;M wrilEan parmselon from Sarch ISSUE 1 Submittal for LSI 9/14115 Review ForConstruotion 921/15 NO. DESCRIPTION DATE DRAWING TITLE: Floor Plans, Typical Section & Door Schedule DRAWING NO: A211.1 SCALE: 10= 1'-Y' DATE: 9/14!15 LSI# PROJECT NO: LSI -33-0120 15781 DES. DRWN. CHK'D. EDE EDE EDE 1 Classic Rib by Metal Sales #W50, "Carlsbad Canyon Tan", 24 gauge PVDF (Kynar 500). A2-1 T.O.W. 108' - 0" F-1 1st Floor _Plan n 00" --------------------------- _ B.O.W. Fnd._-� -- 96'- 6" D1 D1 Overhead -Sectional: 8'x 6'-6" 8' - 0" 61- 8" 1 D2 D2 Single -Flush: 36" x 80" 1 Hr - Insulated Metal Door - 3'- 0" 6'- 8" Curries 707 series standard foam core, 14 Provide Security Hinges, Panic Hardware, and a Lever 2 Metal Frame ga. hinge and lock channel, 16 ga top and Lockset compatible with Xcel keying system PAINT TO MATCH ROOFING COLOR. bottom end channel, 18 ga face skin 3001 Brighton Blvd. Ste. 457 Denver, Colorado 80216 303-455-4117