HomeMy WebLinkAboutCorrection of Change and LayoutTO: GARFIELD COUNTY BUILDING DEPT.2-22-19
FROM: ROB CLASSEN, ARCHITECT
THE DRAWINGBOARD
P.O. BOX 1227
GLENWOOD SPRINGS, COLORADO 81602
DRAWBD@ROF.NET
(e70) 945-5025
RE: THE GIANINETTI EVENT CENTER
591 COWEN DRIVE
CARBONDALE, COLORADO 81623
To whom it may concern,
We were contacted by the owner's and notified that two exterior doors shown on the
approved plans dated 9-14-18, were eliminated. One door on the Southwest end of the
building and one door on the Northeast side of the building.
We have been asked to evaluate the exiting requirements based on the elimination of
these two doors.
Based on the occupant load of 273 occupants, a minimum of two exits is required, with
a total required width of 54.6 inches. Exit doors shall be placed a minimum of one-half
of the building diagonal distance, or 52 feet apart. The maximum travel distance
allowed is 200 feet.
Based on my analysis of the existing building and the exit requirements of the 201518C,
the building meets or exceeds these requirements.
Thank you for your time and consideration of this matter.
Please call me if you have any further questions or concerns.
Sincerely,
ROB CLASSEN, ARCHITECT
THE DRAWINGBOARD