HomeMy WebLinkAboutCorrespondenceDave Argo
From: Dave Argo
Sent: Wednesday, March 13, 2019 2:14 PM
To: 'staceycavallo@yahoo.com'
Cc: Glenn Hartmann; Patrick Waller; Lindsay Krol
Subject: 415 Donegan Road - Permit #BLRE-02-19-5639
Attachments: One-story Addition.pdf
Nicole:
I have reviewed an application for a building permit to convert an existing garage located at 415 County Road 130 (Donegan
Road) into a new Accessory Dwelling Unit (ADU). However, before we can finalize our review there are several key items
which must first be addressed, including the following:
1. Surveyed Site Plan — We require a site layout or plot plan for all projects, and because this building is located so close
to the rear lot line we need for you provide us with an Improvement Location Survey as prepared by a Colorado
licensed Surveyor. This survey must include dimensions from property lines to exterior walls and roof overhangs at
the existing garage.
2. Construction Date of the Original Garage — In addition to an improvement location survey, we also require
confirmation of the original construction date of the garage. Can you provide our office with substantiation of when
this garage was originally built?
3. Engineer's Certificate for Existing Building — Anytime an applicant requests a building permit to change the use of a
un -permitted building, we require a letter from a Colorado licensed design professional (Professional Engineer or
Architect) certifying that the existing building complies with structural soundness and other current building codes
requirements. If the existing structure does not comply with code requirements, an Engineer will typically suggest any
remedial measures which must be undertaken for the structure to comply with the building code. Unfortunately, we
cannot issue a building permit for your requested change in use (ADU residence) from the current use (garage)
without an Engineer's report on structural fitness of the existing garage.
4. Floor Plans — Plans as submitted to our office are incomplete and missing many required items. Please refer to the
attached Building Guide for "Single Family Residential: One -Story Addition" for an example of the type of information
required on floor plans submitted to our office, including the following:
a. Floor plan must be drawn to scale with north arrow shown
b. Show all door (exterior/interior) and window locations
c. Verify egress window sizes at bedrooms
d. Provide plumbing fixture layout at bathroom
e. Illustrate full kitchen layout including: appliances, plumbing fixtures & built-in cabinetry
f. Indicate type and R -value of insulation at thermal envelope
Before you proceed with items #3 and #4, it is suggested that you provide us with items #1 and #2 described above and after
we receive this information we can better advise you as to how we can proceed with your ADU building permit application. I
have asked Glenn Hartmann & Patrick Waller— both of whom are planners here in our office —to assist me with review of this
information.
We will await submission of these requested items and in the meantime your building permit application with be placed in our
pending projects file. Thank you for your patience and assistance in this matter.
Dave Argo
Plans Examiner
Garfield Coat:
Community Development Department
1
Dave Argo
From: Dave Argo
Sent: Monday, March 18, 2019 8:07 AM
To: 'Nicole Amaya'
Subject: RE: 415 Donegan rd ADU
Nicole:
Thanks for this update & we'll look forward to receiving the survey & Architect information from you. Can you please
provide us with an email or other written records from the Assessor's office?
Dave Argo
Plans Examiner
CGarfield County -1
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Tel: 970-945-8212 Ext. 1610
Email: dargo@garfield-county.com
Web: garfield-county.com
From: Nicole Amaya [mailto:nicciamaya86@gmail.com]
Sent: Friday, March 15, 2019 6:11 PM
To: Dave Argo
Subject: 415 Donegan rd ADU
I have talked with the assessors office and they found the garage was built in 1970.
Survey is going to be done next week.
We got ahold of architect and he should be coming next week along with the updated floor plan layout.
Please email me if you have any questions
Nicole
Forwarded message
From: Stephanie Harlan <sharlan�}a garfield-county.com>
Date: Fri, Mar 15, 2019, 4:48 PM
Subject: Sent from Snipping Tool
To: nicciamaya86l`jjgmail.coin <nicciamaya86@gmail.com>
1
Dave Argo
From: Dave Argo
Sent: Tuesday, March 19, 2019 11:09 AM
To: 'Nicole Amaya'
Cc: Patrick Waller; Glenn Hartmann
Subject: RE: 415 Donegan rd ADU
Nicole
Following our phone conversation yesterday, I discussed your project at our weekly staff mtg. this morning where it was
confirmed that we require evidence of the date of construction for the original garage and an updated Improvement
Location Certificate (ILC) of the exact location of the garage from your property boundary lines (including walls & roof
overhang dimensions).
Before you proceed with the Survey, that it would be advantageous for you to schedule a time to come into our office to
discuss these specific items with us. Since there are "planning" issues — not just "building" issues — that need to be
addressed, it is important for one of our planners to be present at this meeting. As a result, I have copied both Patrick
Waller & Glenn Hartmann on this email.
Can you please let us know when you'd like to schedule an appointment so that we can walk you through the specific
items that will need to be addressed before we can consider your building permit application?
Thank you —
Dave Argo
Plans Examiner
_ Garfield Comity
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Tel: 970-945-8212 Ext. 1610
Email: dargo@garfield-county.com
Web: garfield-county.com
From: Nicole Amaya [mailto:nicciamaya86@gmail.com]
Sent: Monday, March 18, 2019 8:10 AM
To: Dave Argo
Subject: Re: 415 Donegan rd ADU
Here is the lady's name at the assessors office.
Isnt it true that if the garage is grandfathered in, we dont really need the survey site plan?
On Fri, Mar 15, 2019, 6:10 PM Nicole Amaya <nicciamaya86�7u,gmail.com> wrote:
I have talked with the assessors office and they found the garage was built in 1970.
Survey is going to be done next week.
We got ahold of architect and he should be coming next week along with the updated floor plan layout.
Please email me if you have any questions
Nicole
1
Dave Argo
From: Dave Argo
Sent: Monday, March 25, 2019 8:10 AM
To: 'Nicole Amaya'
Cc: Lindsay Krol
Subject: RE: 415 Donegan Rd
Attachments: Existing Structure Permit.pdf
Nicole:
David Nicholson dropped off the survey Friday afternoon, but it didn't have everything we need to see on it. We need
more information describing the back side roof overhang and distance away from the property line. He said that he will
be sending updated information to me via email, and once I receive it from him and review, I will be back in touch with
you...probably in the next couple of days.
If you want to go ahead and schedule that site review to verify building code compliance of the existing garage, I have
attached a copy of the requirement we have for a licensed design professional (either an Engineer or Architect) to
provide us with a site review/assessment of existing buildings — see item #2 on attachment.
As we discussed previously, you will need to provide one-hour fire protection for all exterior walls and roof overhangs
that are located within 5 feet of the property line (per IRC, Section R302). Also, no windows or doors are allowed within
3 feet of the property line. In addition, because the new ADU is actually physically attached to the primary residence
with a connecting breezeway or mudroom addition, the wall located between the two separate dwelling units also
needs to be one-hour fire rated assembly (per IRC, Section R302.3). It may be easier for you to simply retrofit the entire
exterior perimeter wall of the existing garage as a one-hour fire rated assembly, which would probably be easier and
simpler to build.
We require that you submit design specifications for the one-hour fire rated wall/roof assembly from a nationally
recognized listing agency, and your design professional should be able to assist you with this.
Dave Argo
Plans Examiner
C. Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Tel: 970-945-8212 Ext. 1610
Email: dargo@garfield-county.com
Web: garfield-county.com
From: Nicole Amaya [mailto:nicciamaya86@gmail.com]
Sent: Friday, March 22, 2019 12:19 PM
To: Dave Argo
Subject: 415 donegan RD
Hi Dave,
I am just checking in for some updates?
Nicole Amaya
Garfield County
BUILDING DEPARTMENT
108 Eighth Slrecl, Suite 401, Glenwood Springs, CU 81601
Tel: (970) 945-8212
Obtaining a Building Permit for an Existing Structure
Because an existing building's structural and architectural elements were not inspected during the initial
construction, the following steps are required to obtain a building permit and subsequent Certificate of
Occupancy (CO) for the structure already built, or otherwise for an existing structure being moved into
Garfield County from another location:
1) Depending on the type and use of the building, a specific permit packet (application and
checklist) must be obtained from the building department. Please call the building department
to determine which packet applies. Building permit application packets are also available online
by visiting:
https://www.garfield-county. com/community-development/building-permit-applications. aspx
2) A Colorado licensed design professional (Architect or Engineer) must perform a site visit and
inspection to verify the structure meets the requirements for structural and non-structural
provisions of the adopted codes. As part of the building permit application process, the design
professional must certify with a sealed letter that the building meets adopted codes. This letter
must accompany the building permit application. Depending on the complexity of the structure,
building plans may also need to be drawn and submitted with the application.
3) Upon approval of the application, a permit will be issued and the final permit fees will be
collected. Typically there are one or two inspections performed by the county to finalize the
process and issue a CO if applicable.
4) Additional permits for septic, electrical or driveways may be required and must be submitted
and finalized prior to issuance of a CO if applicable.
Please contact the Community Development department with any questions or concerns.
Dave Argo
From: Dave Argo
Sent: Monday, April 8, 2019 11:17 AM
To: 'Kurt Carruth'
Cc: 'Nicole Amaya'
Subject: RE: 415 Donegan Road
Kurt:
Thanks for providing us with plan amendments for Nicole's project on Donegan Road.
Based on my initial review, I think we have almost everything we need. However, your letter describing the existing
structure does not provide us with enough information. We need for either an Architect or Engineer to verify that the
existing roof structure will support a 40 PSF snow load per our minimum code requirements — or, alternately, what
remedial work may need to be performed to achieve this requirement. If you aren't comfortable providing us with that
certification, then Nicole may need to hire a Structural Engineer to provide us with a letter of certification for our files.
Thanks & I'll let you know by the end of the day if there's anything else we need. Please note that we will need to
receive the requested certification of roof structure before we can issue the building permit.
Dave Argo
Plans Examiner
Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Tel: 970-945-8212 Ext. 1610
Email: dargo@garfield-county.com
Web: garfield-county.com
From: Kurt Carruth [mailto:kurt@hinge-architects.com]
Sent: Friday, April 5, 2019 2:52 PM
To: Dave Argo
Subject: 415 Donegan Road
Dave:
I dropped off a few documents with Brooke for the 415 Donegan road ADU project.
Attached is my 'structure' letter. Please review and get back to me if I need to add anything.
Thanks -
Kurt Carruth, architect
ARCHITECTS, Ltd.
812 grand avenue, ste. 201
gws, co. 81601
c:970-309-4432
www.hinge-architects.com
1