HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-03-19-5687 Mark Sage Pre -Fabricated Steel Shop Building 1181 County Road 259 — Rifle, Colorado Scutter Gulch, Tract 5C 1) ALL WORK MUST COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REQUIREMENTS". NUMBERED REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) PROPOSED BUILDING IS APPROVED AS ACCESSORY STRUCTURE TO RESIDENTIAL USE. CHANGE IN USE AND/OR OCCUPANCY MAY REQUIRE A LAND -USE CHANGE PERMIT AND/OR ADDITIONAL BUILDING PERMIT. 4) OPEN -HOLE SOILS REPORT REQUIRED AT FOOTING INSPECTION, 2500 P.S.F. AND TO VERIFY STRUCTURAL FILL REQUIREMENTS AS DESCRIBED IN THE SOILS REPORT. 5) A WALK-THROUGH SIDE -HINGED DOOR (MIN. SIZE: 36" WIDE X 80" HT.) FOR EGRESS IS REQUIRED. 6) GARFIELD COUNTY FOUNDATION, FRAMING AND FINAL/CERTIFICATE OF OCCUPANCY INSPECTIONS ARE REQUIRED. 7) ALL HIGH-STRENGTH BOLTING AND/OR FIELD WELDING REQUIRES SPECIAL INSPECTOR. APPROVAL REPORT REQUIRED AT FINAL INSPECTION. 8) IF BUILDING IS TO BE HEATED - AT PRESENT OR FUTURE - SEE ITEMS #59, 62, 63, 64, 65 AND 71 OF PLAN ATTACHMENTS. 9) IF STRUCTURE IS INTENDED TO BE HEATED, BUILDING SHALL CONFORM TO 2009 I.E.C.C. REQUIREMENTS INCLUDING R-10 RIGID INSULATION AT CONCRETE SLAB EDGE ALONG PERIMETER OF FOUNDATION (PER I.E.C.C., SECTION 402.2.8) 10) ELECTRICAL PERMITTING AND INSPECTIONS BY STATE OF COLORADO ELECTRICAL BOARD. ELECTRICAL FINAL APPROVAL IS REQUIRED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY.