HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-12-18-5600
Vicco's 11, LLC
Manufactured Steel Building for Garage/Residential Accessory Use
45755 Highway 6 & 24 (Canyon Creek) — Glenwood Springs
1) ALL WORK SHALL COMPLY WITH 2015 I.B.C., I.R.C., I.F.C., AND 2009 I.E.C.C., AS WELL AS
MANUFACTURER'S INSTALLATION REQUIREMENTS. THIS STRUCTURE SHALL ALSO COMPLY
WITH ALL REQUIREMENTS OF GARFIELD COUNTY'S "RESIDENTIAL URBAN" ZONE DISTRICT AND
BOARD OF ADJUSTMENT RESOLUTION #1-2019.
2) IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED
"GARFIELD COUNTY BUILDING REQUIREMENTS". NUMBERED REFERENCES NOTED ON PLANS
REFER TO SPECIFIC ITEMS ON THIS LIST.
3) BUILDING IS APPROVED AS A DETACHED RESIDENTIAL ACCESSORY STRUCTURE FOR PRIVATE
USE ONLY. IT IS CLASSIFIED BY THE BUILDING CODE AS TYPE II, NON -RATED CONSTRUCTION
WITH OCCUPANCY/USE "U" (UTILITY). ANY CHANGE IN USE OR OCCUPANCY (FOR EXAMPLE,
COMMERCIAL USE) MAY REQUIRE A LAND USE CHANGE PERMIT AND/OR BUILDING PERMIT.
4) THIS BUILDING PERMIT IS ISSUED FOR AN UNHEATED BUILDING SHELL ONLY. SUBSEQUENT
CONSTRUCTION AT BUILDING INTERIOR - INCLUDING INSULATION, HEATING SYSTEM, INTERIOR
FINISH OR PARTITION WALLS - WILL REQUIRE AMENDED PLANS TO BE SUBMITTED TO THE
BUILDING DEPT. FOR REVIEW & APPROVAL.
5) IF BUILDING IS HEATED - EITHER AT PRESENT OR IN THE FUTURE - REFER TO ATTACHED ITEMS
#59, 62, 63, 64, 65 & 71. STEEL BUILDING SHALL COMPLY WITH 2009 I.E.C.C., TABLE 402.2.5 FOR
INSULATION AT THERMAL ENVELOPE - INCLUDING RIGID INSULATION AT CONCRETE SLAB EDGE
AND FOUNDATION PERIMETER PER I.E.C.C., SECTION 402.2.8.
6) AN OPEN -HOLE SOILS REPORT PREPARED BY A COLORADO LICENSED PROFESSIONAL ENGINEER
IS REQUIRED AT FOOTING INSPECTION TO VERIFY 1,000 P.S.F. SOILS BEARING CAPACITY.
PROVIDE COPY OF REPORT FOR BUILDING INSPECTOR REVIEW AT FOUNDATION INSPECTION.
7) A LOT IMPROVEMENT CERTIFICATE SEALED BY A COLORADO LICENSED SURVEYOR IS REQUIRED
AT FOUNDATION INSPECTION TO VERIFY THAT STRUCTURE WILL BE IN COMPLIANCE WITH ALL
SETBACK REQUIREMENTS.
8) ALL HIGH-STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR PER SPECIAL
INSPECTIONS PROVISIONS OF I.B.C., CHAPTER 17. PROVIDE APPROVAL REPORT AT FRAME
INSPECTION.
9) A MINIMUM OF ONE WALK-THROUGH SIDE -HINGED DOOR (MIN. SIZE: 36" WIDE x 80" HEIGHT)
IS REQUIRED FOR EGRESS.
10) REQUIRED GARFIELD COUNTY INSPECTIONS INCLUDE: FOOTINGS, FOUNDATION, STEEL FRAME,
AND FINAL BUILDING INSPECTION/CERTIFICATE OF OCCUPANCY.
11) ELECTRICAL PERMITTING & INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD. ELECTRICAL
ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL SIGN -OFF IS
REQUIRED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY.